Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA DECAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Wobbly Dark Matter Signals at Cherenkov Telescopes from Long-Lived Mediator Decays

Imaging Atmospheric Cherenkov telescope (IACT) searches for dark matter often perform observations in “wobble mode,” i.e., simultaneously collecting data from the signal region and from a corresponding background control region. This observation strategy is possibly compromised in scenarios where dark matter annihilates to long-lived mediators that can traverse astrophysical distances before decaying to produce the gamma rays observed by the IACTs. In this Letter, we show that this challenge comes with several interesting features and opportunities: in addition to signal contamination in the background control region, the gamma-ray spectrum changes with the observing direction angle and typically exhibits a hard excess at high energies. Furthermore, such features represent a significant departure from the canonical picture and offer novel handles to identify a dark matter signal and to extract underlying dark matter parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

First study of the $^{139}\text{Ba}(n,y)^{140}\text{Ba}$ reaction to constrain the conditions for the astrophysical $\mathcal{i}$ process

New astronomical observations point to a nucleosynthesis picture that goes beyond what was accepted until recently. The intermediate “i” process was proposed as a plausible scenario to explain some of the unusual abundance patterns observed in metal-poor stars. The most important nuclear physics properties entering i-process calculations are the neutron-capture cross sections and they are almost exclusively not known experimentally. In this report we provide the first experimental constraints on the 139 Ba(n,γ) 140 Ba reaction rate, which is the dominant source of uncertainty for the production of lanthanum, a key indicator of i-process conditions. This is an important step towards identifying the exact astrophysical site of stars carrying the i-process signature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Origin of a signal detected with the LSD detector after the accident at the chernobyl nuclear power plant

A rare signal was detected at 23:53 Moscow time on April 27, 1986 with the LSD low-background scintillation detector located under Mont Blanc at a distance of 1820 km from Chernobyl. To reveal the origin of this signal, we discuss the results obtained with other instruments operating within a similar program, as well as analyze the characteristics of the pulses of the signal and facts referring to the explosion of the Chernobyl reactor. A hypothesis based on detection with the LSD of gamma-quanta from {beta} decays of {sup 135}I nuclei ejected into atmosphere by the reactor explosion and carried in the underground detector camera with air of positive ventilation is considered. The explosion origin of the LSD signal indicates a new technogenic source of the background in the search for neutrino bursts from cores of collapsing stars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluctuations of the number of neutral pions at high multiplicity in pp interactions at 50 GeV

Results obtained by measuring fluctuations of the number of neutral pions in the SERP-E-190 Experiment (Thermalization Project) upon irradiating a liquid-hydrogen target of the SVD-2 setup with a beam of 50-GeV protons are presented. A simulation of the detection of photons from the decay of neutral pions with the aid of an electromagnetic calorimeter revealed a linear relation between the number of detected photons and the mean number of neutral pions in an event. After the introduction of corrections for the loss of charged tracks because of a limited acceptance of the setup, trigger operation, and the efficiency of the data-treatment system, distributions of the number of neutral pions, N{sub 0}, were obtained for each value of the total number of particles in an event, N{sub tot} = N{sub ch} + N{sub 0}. The fluctuation parameter {omega} = D/ Left-Pointing-Angle-Bracket N{sub 0} Right-Pointing-Angle-Bracket was measured. In the region N{sub tot} > 22, fluctuations of the number of neutral pions increase, which, within statistical models (GCE, CE, MCE), indicates that the system involving a large number of pions approaches the pion-condensate state. This effect was observed for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetime measurement of excited states in 116 Xe

Lifetimes of excited states in 116 Xe were measured using the recoil-distance Doppler-shift technique. Excited 116 Xe nuclei were populated in the fusion-evaporation reaction 102 Pd( 16 O,2n) 116 Xe. Lifetimes of the $2^{+}_{1}$ and $4^{+}_{1}$ states were evaluated using the differential decay-curve method with $\gamma$-$\gamma$-coincidence data as well as lifetimes of the $6^{+}_{1}$ and $7^{-}_{1}$ states using simulations of spectra considering Doppler-shift attenuation effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SCALE Code System 6.2.1

The SCALE Code System is a widely-used modeling and simulation suite for nuclear safety analysis and design that is developed, maintained, tested, and managed by the Reactor and Nuclear Systems Division (RNSD) of Oak Ridge National Laboratory (ORNL). SCALE provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor and lattice physics, radiation shielding, spent fuel and radioactive source term characterization, and sensitivity and uncertainty analysis. Since 1980, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides an integrated framework with dozens of computational modules including three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution strategy. SCALE includes current nuclear data libraries and problem-dependent processing tools for continuous-energy (CE) and multigroup (MG) neutronics and coupled neutron-gamma calculations, as well as activation, depletion, and decay calculations. SCALE includes unique capabilities for automated variance reduction for shielding calculations, as well as sensitivity and uncertainty analysis. SCALE’s graphical user interfaces assist with accurate system modeling, visualization of nuclear data, and convenient access to desired results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving Fission Products at CARIBU: Near Field Detection (Q1/FY23 Quarterly Progress Report)

We performed a branching ratio measurement of the most intense gamma rays in the decay of 111Ag. The sample was harvested at Argonne National Laboratory and measured at Texas A&M with the same technique as we used in our previous measurements. We made two samples and were able to measure both of them. The data is currently under analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chromospheric condensation and quasi-periodic pulsations in a circular-ribbon flare

In this paper, we report our multiwavelength observations of the C3.1 circular-ribbon flare SOL2015-10-16T10:20 in active region (AR) 12434. The flare consisted of a circular flare ribbon (CFR), an inner flare ribbon (IFR) inside it, and a pair of short parallel flare ribbons (PFRs). The PFRs located to the north of the IFR were most striking in the Interface Region Imaging Spectrograph (IRIS) 1400 and 2796 Å images. For the first time, we observed the circular-ribbon flare in the Ca ii H line of the Solar Optical Telescope on board Hinode, which has a similar shape as observed in the Atmospheric Imaging Assembly 1600 Å on board the Solar Dynamic Observatory (SDO). Photospheric line-of-sight magnetograms from the Helioseismic and Magnetic Imager on board SDO show that the flare is associated with positive polarities with a negative polarity inside. The IFR and CFR were cospatial with the negative polarity and positive polarities, implying the existence of a magnetic null point (B=0) and a dome-like spine–fan topology. During the impulsive phase of the flare, “two-step” raster observations of IRIS with a cadence of 6 s and an exposure time of 2 s showed plasma downflow at the CFR in the Si iv λ1402.77 line (logT≈4.8), suggesting chromospheric condensation. The downflow speeds first increased rapidly from a few km s{sup −1} to the peak values of 45–52 km s{sup −1}, before decreasing gradually to the initial levels. The decay timescales of condensation were 3–4 minutes, indicating ongoing magnetic reconnection. Interestingly, the downflow speeds are positively correlated with the logarithm of the Si iv line intensity and time derivative of the GOES soft X-ray (SXR) flux in 1–8 Å. The radio dynamic spectra are characterized by a type III radio burst associated with the flare, which implies that the chromospheric condensation was most probably driven by nonthermal electrons. Using an analytical expression and the peak Doppler velocity, we derive the lower limit of energy flux of the precipitating electrons, i.e., 0.65 × 10{sup 10} erg cm{sup −2} s{sup −1}. The Si iv line intensity and SXR derivative show quasi-periodic pulsations with periods of 32–42 s, which are likely caused by intermittent null-point magnetic reconnections modulated by the fast wave propagating along the fan surface loops at a phase speed of 950–1250 km s{sup −1}. Periodic accelerations and precipitations of the electrons result in periodic heating observed in the Si iv line and SXR.

79 ASTRONOMY AND ASTROPHYSICS↗

Solar Gamma Rays Above 8 MeV

Processes which lead to the production of gamma rays with energy greater than 8 MeV in solar flares are reviewed and evaluated. Excited states produced by inelastic scattering, charge exchange, and spallation reactions in the abundant nuclear species are considered in order to identify nuclear lines which may contribute to the Gamma ray spectrum of solar flares. The flux of 15.11 MeV Gamma rays relative to the flux of 4.44 MeV Gamma rays from the de-excitation of the corresponding states in C12 is calculated for a number of assumed distributions of exciting particles. This flux ratio is a sensitive diagnostic of accelerated particle spectra. Other high energy nuclear levels are not so isolated as the 15.11 MeV state and are not expected to be so strong. The spectrum of Gamma rays from the decay of Pi dey is sensitive to the energy distribution of particles accelerated to energies greater than 100 MeV.

Crannell, C. J.↗

Solar gamma rays above 8 MeV

Processes that lead to the production of gamma rays with energy greater than 8 MeV in solar flares are reviewed and evaluated. Excited states that can be produced by inelastic scattering, charge exchange, and spallation reactions in the abundant nuclear species are considered in order to identify nuclear lines that may contribute to the gamma-ray spectrum of solar flares. The flux of 15.11-MeV gamma rays relative to the flux of 4.44-MeV gamma rays from the deexcitation of the corresponding states in C-12 is calculated for a number of assumed distributions of exciting particles. This flux ratio is shown to be a sensitive diagnostic of accelerated particle spectra. Other high-energy nuclear levels are not so isolated as the 15.11-MeV state and are not expected to be so strong. The spectrum of gamma rays from the decay of neutral pions is shown to be sensitive to the energy distribution of particles accelerated to energies greater than 100 MeV.

Crannell, C. J.↗

Observational tests of Baryon symmetric cosmology

Observational evidence for Baryon symmetric (matter/antimatter) cosmology and future observational tests are reviewed. The most significant consequences of Baryon symmetric cosmology lie in the prediction of an observable cosmic background of gamma radiation from the decay of pi(0)-mesons produced in nucleon-antinucleon annihilations. Equations for the prediction of the amma ray background spectrum for the case of high redshifts are presented. The theoretical and observational plots of the background spectrum are shown to be in good agreement. Measurement of cosmic ray antiprotons and the use of high energy neutrino astronomy to look for antimatter elsewhere in the universe are also addressed.

Stecker, F. W.↗

Neutral pion production in solar flares

The Gamma-Ray Spectrometer (GRS) on SMM has detected more than 130 flares with emission approx 300 keV. More than 10 of these flares were detected at photon energies 10 MeV. Although the majority of the emission at 10 MeV must be from electron bremsstrahlung, at least two of the flares have spectral properties 40 MeV that require gamma rays from the decay of neutral pions. It is found that pion production can occur early in the impulsive phase as defined by hard X-rays near 100 keV. It is also found in one of these flares that a significant portion of this high-energy emission is produced well after the impulsive phase. This extended production phase, most clearly observed at high energies, may be a signature of the acceleration process which produces solar energetic particles (SEP's) in space.

Forrest, D. J.↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗