Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRAMING CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Estimation of full-field dynamic strains from digital video measurements of output-only beam structures by video motion processing and modal superposition

Strain is an necessary quantity to characterize local structural behaviors and directly correlates with structural damage initiation and development that is within local regions. Strain measurement at high spatial resolution (density) locations is thus required to characterize local structural behaviors and detect potential local damage. Traditional contact-type strain gauges are mostly discrete point-wise sensors that can only be placed in a limited number of positions. Distributed optical fiber sensing techniques can measure strains at spatially dense measurement points, but their instrumentation is a time- and labor-intensive process associated with the issue of the fragility of fibers. Noncontact optical measurement techniques, such as a family of interferometry techniques using laser beams (e.g., laser Doppler vibrometers), can provide vibration measurement at high density spatial points without the need to install sensors on the structure. Yet, these measurement devices are active sensing methods that are relatively expensive and vulnerable to ambient motion. Photogrammetry is an alternative noncontact optical measurement method using (passive) white-light imaging of digital video cameras that are relatively low-cost, agile, and provides simultaneous measurements at high spatial density locations where every pixel becomes a measurement point. Among others, digital image correlation can achieve full-field deformation measurements and subsequently estimate the full-field strains. However, it is computationally extensive. This research develops a new efficient approach to estimate the full-field (as many measurement points as the pixel number of the video frame on the structure) dynamic strains at high-spatial (pixel)-resolution/density location points from the digital video measurement of output-only vibrating structures. The developed approach is based on phase-based video motion estimation and modal superposition of structural dynamic response. Moreover, the method is augmented by a high-fidelity finite element model, which is updated with the full-field experimental modal parameters “blindly” identified from the video measurement of the output-only structure. Laboratory experiments are conducted to validate the method on a bench-scale cantilever beam structure. Results demonstrate that the full-field dynamic strain estimated by the developed approach from the video measurement of the output-only vibrating beam match very well those directly measured by the strain gauges (at discrete measurement points). Some factors associated with the effectiveness of the method are experimentally studied and discussed.

47 OTHER INSTRUMENTATION↗

Simulation of a passive millimeter wave sensor

The visual display expected to be generated by a Passive Millimeter Wave (PMMW) camera and sensor system has been simulated on a Silicon Graphics IRIS workstation at the NASA Langley Research Center (LaRC). The low resolution of the sensor has been simulated by graphically manipulating the scene as it is being drawn by the IRIS in real time. Camera field of view, sensor resolution, and sensor update rate are the controllable parameters. Physical effects such as lens model, radome effects, and noise have not been included at this time. An approximate dynamic model of the atmospheric phenomenology has been included which generates the gray-scale intensity values in real time for the simulated image. The gray-scale values are proportional to temperature. A snapshot capability which captures individual image frames during real-time operation has been included. These images were used to validate the approximate phenomenology model against a more rigorous physical model.

Kahlbaum, William W.↗

The First Diffraction-Limited Images from the W. M. Keck Telescope

The first diffraction limited, 0.05s resolution, images on the W. M. Keck Telescope have been obtained at a wavelength of 2.2 micrometers. These images were part of an experiment to test the suitability of the Keck Telescope for speckle imaging. In order to conduct this test, it was necessary to modify the pixel scale of the Keck facility Near Infrared Camera (NIRC) to optimally sample the spatial frequencies made available by the Keck telescope. The design and implementation of the external reimaging optics, which convert the standard fl25 beam from the secondary mirror to fl182, are described here. Techniques for reducing speckle data with field rotation on an alt-az telescope are also described. Three binary stars were observed in this experiment with separations as small as 0.05s. With only 100 frames of data on each, a dynamic range of at least 3.5 mag was achieved in all cases. These observations imply that a companion as faint as 14.5 mag at 2.2 micrometers could be detected around an 11th magnitude point source.

Matthews, K.↗

INTRINSIC SHAPE OF STAR-FORMING BzK GALAXIES AT z {approx} 2 IN GOODS-N

We study the structure of star-forming galaxies at z {approx} 2 in a Great Observatories Origins Deep Survey North field selected as star-forming BzK (sBzK) galaxies down to K{sub AB} < 24.0 mag. Among 1029 sBzK galaxies, 551 galaxies (54%) show a single component in the Advanced Camera for Survey (ACS)/F850LP image obtained with the Hubble Space Telescope; the rest show multiple components. We fit the single-component sBzK galaxies with the single Sersic profile using the ACS/F850LP image and find that a majority of them (64%) show a Sersic index of n = 0.5-2.5, indicating that they have a disk-like structure. The resulting effective radii typically range from 1.0 to 3.0 kpc in the rest-frame UV wavelength. After correcting the effective radii to those in the rest-frame optical wavelength, we find that the single-component sBzK galaxies are located in the region where the local and z {approx} 1 disk galaxies are distributed in the stellar-mass-size diagram, suggesting comparable surface stellar-mass density between the sBzK and z {approx} 0-1 disk galaxies. All these properties suggest that the single-component sBzK galaxies are progenitors of the present-day disk galaxies. However, by studying their intrinsic shape through comparison between the observed distribution of apparent axial ratios and the distribution for triaxial models with axes A > B > C, we find that the mean B/A ratio is 0.61{sup +0.05}{sub -0.08} and disk thickness C/A is 0.28{sup +0.03}{sub -0.04}. This indicates that the single-component sBzK galaxies at z {approx} 2 have a bar-like or oval shape rather than a round disk shape. The shape seems to resemble a bar/oval structure that forms through bar instability; if this is the case, the intrinsic shape may give us a clue to understand dynamical evolution of baryonic matter in a dark matter halo.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-AB-BRA-12: Quality Assurance of An Integrated Magnetic Resonance Image Guided Adaptive Radiotherapy Machine Using Cherenkov Imaging

Purpose: To investigate the viability of using Cherenkov imaging as a fast and robust method for quality assurance tests in the presence of a magnetic field, where other instruments can be limited. Methods: Water tank measurements were acquired from a clinically utilized adaptive magnetic resonance image guided radiation therapy (MR-IGRT) machine with three multileaf-collimator equipped 60Co sources. Cherenkov imaging used an intensified charge coupled device (ICCD) camera placed 3.5m from the treatment isocenter, looking down the bore of the 0.35T MRI into a water tank. Images were post-processed to make quantitative comparison between Cherenkov light intensity with both film and treatment planning system predictions, in terms of percent depth dose curves as well as lateral beam profile measurements. A TG-119 commissioning test plan (C4: C-Shape) was imaged in real-time at 6.33 frames per second to investigate the temporal and spatial resolution of the Cherenkov imaging technique. Results: A .33mm/pixel Cherenkov image resolution was achieved across 1024×1024 pixels in this setup. Analysis of the Cherenkov image of a 10.5×10.5cm treatment beam in the water tank successfully measured the beam width at the depth of maximum dose within 1.2% of the film measurement at the same point. The percent depth dose curve for the same beam was on average within 2% of ionization chamber measurements for corresponding depths between 3–100mm. Cherenkov video of the TG-119 test plan provided qualitative agreement with the treatment planning system dose predictions, and a novel temporal verification of the treatment. Conclusions: Cherenkov imaging was successfully used to make QA measurements of percent depth dose curves and cross beam profiles of MRI-IGRT radiotherapy machines after only several seconds of beam-on time and data capture; both curves were extracted from the same data set. Video-rate imaging of a dynamic treatment plan provided new information regarding temporal dose deposition. This study has been funded by NIH grants R21EB17559 and R01CA109558, as well as Norris Cotton Cancer Center Pilot funding.

60 APPLIED LIFE SCIENCES↗

Hybrid Image-Plane/Stereo Manipulation

Hybrid Image-Plane/Stereo (HIPS) manipulation is a method of processing image data, and of controlling a robotic manipulator arm in response to the data, that enables the manipulator arm to place an end-effector (an instrument or tool) precisely with respect to a target (see figure). Unlike other stereoscopic machine-vision-based methods of controlling robots, this method is robust in the face of calibration errors and changes in calibration during operation. In this method, a stereoscopic pair of cameras on the robot first acquires images of the manipulator at a set of predefined poses. The image data are processed to obtain image-plane coordinates of known visible features of the end-effector. Next, there is computed an initial calibration in the form of a mapping between (1) the image-plane coordinates and (2) the nominal three-dimensional coordinates of the noted end-effector features in a reference frame fixed to the main robot body at the base of the manipulator. The nominal three-dimensional coordinates are obtained by use of the nominal forward kinematics of the manipulator arm that is, calculated by use of the currently measured manipulator joint angles and previously measured lengths of manipulator arm segments under the assumption that the arm segments are rigid, that the arm lengths are constant, and that there is no backlash. It is understood from the outset that these nominal three-dimensional coordinates are likely to contain possibly significant calibration errors, but the effects of the errors are progressively reduced, as described next. As the end-effector is moved toward the target, the calibration is updated repeatedly by use of data from newly acquired images of the end-effector and of the corresponding nominal coordinates in the manipulator reference frame. By use of the updated calibration, the coordinates of the target are computed in manipulator-reference-frame coordinates and then used to the necessary manipulator joint angles to position and orient the end-effector at the target with respect to the same kinematic model from the calibration step. As the end-effector/target distance decreases, the computed coordinates of the end-effector and target become more nearly affected by the same errors, so that the differences between their coordinates become increasingly precise. When the end-effector reaches the target, the remaining effective position error is the distance that corresponds to more than about one pixel in the stereoscopic images of the target.

Baumgartner, Eric↗

DUST OBSCURATION IN LYMAN BREAK GALAXIES AT z {approx} 4

Measuring star formation rates (SFRs) in high-z galaxies with their rest-frame ultraviolet (UV) continuum can be uncertain because of dust obscuration. Prior studies had used the submillimeter emission at 850 {mu}m to determine the intrinsic SFRs of rest-frame UV-selected galaxies, but the results suffered from the low sensitivity and poor resolution ({approx}15''). Here, we use ultradeep Very Large Array 1.4 GHz images with {approx}1''-2'' resolutions to measure the intrinsic SFRs. We perform stacking analyses in the radio images centered on {approx}3500 Lyman break galaxies (LBGs) at z {approx} 4 in the Great Observatories Origins Deep Survey-North and South fields selected with Hubble Space Telescope/Advanced Camera for Surveys data. The stacked radio flux is very low, 0.08 {+-} 0.15 {mu}Jy, implying a mean SFR of 6 {+-} 11 M{sub sun} yr{sup -1}. This is comparable to the uncorrected mean UV SFRs of {approx}5 M{sub sun} yr{sup -1}, implying that the z {approx} 4 LBGs have little dust extinction. The low SFR and dust extinction support the previous results that z {approx} 4 LBGs are in general not submillimeter galaxies. We further show that there is no statistically significant excess of dust-hidden star-forming components within {approx}22 kpc from the LBGs.

79 ASTRONOMY AND ASTROPHYSICS↗

MOIRCS DEEP SURVEY. VIII. EVOLUTION OF STAR FORMATION ACTIVITY AS A FUNCTION OF STELLAR MASS IN GALAXIES SINCE z {approx} 3

We study the evolution of star formation activity of galaxies at 0.5 < z < 3.5 as a function of stellar mass, using very deep NIR data taken with the Multi-Object Infrared Camera and Spectrograph on the Subaru telescope in the GOODS-North region. The NIR imaging data reach K{approx} 23-24 Vega magnitude and they allow us to construct a nearly stellar-mass-limited sample down to {approx}10{sup 9.5-10} M{sub sun} even at z {approx} 3. We estimated star formation rates (SFRs) of the sample with two indicators, namely, the Spitzer/MIPS 24 {mu}m flux and the rest-frame 2800 A luminosity. The SFR distribution at a fixed M{sub star} shifts to higher values with increasing redshift at 0.5 < z < 3.5. More massive galaxies show stronger evolution of SFR at z {approx}> 1. We found galaxies at 2.5 < z < 3.5 show a bimodality in their SSFR distribution, which can be divided into two populations by a constant SSFR of {approx}2 Gyr{sup -1}. Galaxies in the low-SSFR group have SSFRs of {approx}0.5-1.0 Gyr{sup -1}, while the high-SSFR population shows {approx}10 Gyr{sup -1}. The cosmic SFR density (SFRD) is dominated by galaxies with M{sub star} = 10{sup 10-11} M{sub sun} at 0.5 < z < 3.5, while the contribution of massive galaxies with M{sub star} = 10{sup 11-11.5} M{sub sun} shows a strong evolution at z>1 and becomes significant at z {approx} 3, especially in the case with the SFR based on MIPS 24 {mu}m. In galaxies with M{sub star} = 10{sup 10-11.5} M{sub sun}, those with a relatively narrow range of SSFR ({approx}<1 dex) dominates the cosmic SFRD at 0.5 < z < 3.5. The SSFR of galaxies that dominate the SFRD systematically increases with redshift. At 2.5 < z < 3.5, the high-SSFR population, which is relatively small in number, dominates the SFRD. Major star formation in the universe at higher redshift seems to be associated with a more rapid growth of stellar mass of galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytical Tools for Cloudscope Ice Measurement

The cloudscope is a ground or aircraft instrument for viewing ice crystals impacted on a sapphire window. It is essentially a simple optical microscope with an attached compact CCD video camera whose output is recorded on a Hi-8 mm video cassette recorder equipped with digital time and date recording capability. In aircraft operation the window is at a stagnation point of the flow so adiabatic compression heats the window to sublimate the ice crystals so that later impacting crystals can be imaged as well. A film heater is used for ground based operation to provide sublimation, and it can also be used to provide extra heat for aircraft operation. The compact video camera can be focused manually by the operator, and a beam splitter - miniature bulb combination provide illumination for night operation. Several shutter speeds are available to accommodate daytime illumination conditions by direct sunlight. The video images can be directly used to qualitatively assess the crystal content of cirrus clouds and contrails. Quantitative size spectra are obtained with the tools described in this report. Selected portions of the video images are digitized using a PCI bus frame grabber to form a short movie segment or stack using NIH (National Institute of Health) Image software with custom macros developed at DRI. The stack can be Fourier transform filtered with custom, easy to design filters to reduce most objectionable video artifacts. Particle quantification of each slice of the stack is performed using digital image analysis. Data recorded for each particle include particle number and centroid, frame number in the stack, particle area, perimeter, equivalent ellipse maximum and minimum radii, ellipse angle, and pixel number. Each valid particle in the stack is stamped with a unique number. This output can be used to obtain a semiquantitative appreciation of the crystal content. The particle information becomes the raw input for a subsequent program (FORTRAN) that synthesizes each slice and separates the new from the sublimating particles. The new particle information is used to generate quantitative particle concentration, area, and mass size spectra along with total concentration, solar extinction coefficient, and ice water content. This program directly creates output in html format for viewing with a web browser.

Arnott, W. Patrick↗

Study of the detail content of Apollo orbital photography

The results achieved during a study of the Detail Content of Apollo Orbital Photography are reported. The effect of residual motion smear or image reproduction processes upon the detail content of lunar surface imagery obtained from the orbiting command module are assessed. Data and conclusions obtained from the Apollo 8, 12, 14 and 15 missions are included. For the Apollo 8, 12 and 14 missions, the bracket-mounted Hasselblad camera had no mechanism internal to the camera for motion compensation. If the motion of the command module were left totally uncompensated, these photographs would exhibit a ground smear varying from 12 to 27 meters depending upon the focal length of the lens and the exposure time. During the photographic sequences motion compensation was attempted by firing the attitude control system of the spacecraft at a rate to compensate for the motion relative to the lunar surface. The residual smear occurring in selected frames of imagery was assessed using edge analyses methods to obtain and achieved modulation transfer function (MTF) which was compared to a baseline MTF.

Kinzly, R. E.↗

0.4- to 10-GHz airborne electromagnetic-environment survey of United States urban areas

An airborne electromagnetic-environment survey of some U.S. metropolitan areas measured terrestrial emissions within the broad-frequency spectrum from 0.4 to 10 GHz. A Cessna 402 commercial aircraft was fitted with both nadir-viewing and horizon-viewing antennas and instrumentation, including a spectrum analyzer, a 35-mm continuous-film camera, and a magnetic-tape recorder. Most of the flights were made at a nominal altitude of 10,000 ft, and Washington, Baltimore, Philadelphia, New York, and Chicago were surveyed. The 450- to 470-MHz land-mobile UHF band is especially crowded, and the 400- to 406-MHz space bands are less active. Test measurements obtained up to 10 GHz are discussed. Sample spectrum-analyzer photographs were selected from a total of 5750 frames representing 38 hours of data.

Taylor, R. E.↗

HUBBLE SPACE TELESCOPE NARROWBAND SEARCH FOR EXTENDED Ly{alpha} EMISSION AROUND TWO z > 6 QUASARS

We search for extended Ly{alpha} emission around two z > 6 quasars, SDSS J1030+0524 (z = 6.309) and SDSS J1148+5251 (z = 6.419) using Wide Field Camera 3 narrowband filters on board the Hubble Space Telescope. For each quasar, we collected two deep, narrowband images, one sampling the Ly{alpha} line+continuum at the quasar redshifts and one of the continuum emission redward of the line. After carefully modeling the point-spread function, we find no evidence for extended Ly{alpha} emission. These observations set 2{sigma} limits of L(Ly{alpha}, extended) <3.2 Multiplication-Sign 10{sup 44} erg s{sup -1} for J1030+0524 and L(Ly{alpha}, extended) <2.5 Multiplication-Sign 10{sup 44} erg s{sup -1} for J1148+5251. Given the star formation rates typically inferred from (rest-frame) far-infrared measurements of z {approx} 6 quasars, these limits are well below the intrinsic bright Ly{alpha} emission expected from the recombination of gas photoionized by the quasars or by the star formation in the host galaxies, and point toward significant Ly{alpha} suppression or dust attenuation. However, small extinction values have been observed along the line of sight to the nuclei, thus reddening has to be coupled with other mechanisms for Ly{alpha} suppression (e.g., resonance scattering). No Ly{alpha} emitting companions are found, down to a 5{sigma} sensitivity of {approx}1 Multiplication-Sign 10{sup -17} erg s{sup -1} cm{sup -2} arcsec{sup -2} (surface brightness) and {approx}5 Multiplication-Sign 10{sup -17} erg s{sup -1} cm{sup -2} (assuming point sources).

79 ASTRONOMY AND ASTROPHYSICS↗

An Integrated Optimal Estimation Approach to Spitzer Space Telescope Focal Plane Survey

This paper discusses an accurate and efficient method for focal plane survey that was used for the Spitzer Space Telescope. The approach is based on using a high-order 37-state Instrument Pointing Frame (IPF) Kalman filter that combines both engineering parameters and science parameters into a single filter formulation. In this approach, engineering parameters such as pointing alignments, thermomechanical drift and gyro drifts are estimated along with science parameters such as plate scales and optical distortions. This integrated approach has many advantages compared to estimating the engineering and science parameters separately. The resulting focal plane survey approach is applicable to a diverse range of science instruments such as imaging cameras, spectroscopy slits, and scanning-type arrays alike. The paper will summarize results from applying the IPF Kalman Filter to calibrating the Spitzer Space Telescope focal plane, containing the MIPS, IRAC, and the IRS science Instrument arrays.

optimal estimations↗

A 0.4 to 10 GHz airborne electromagnetic environment survey of USA urban areas

An airborne electromagnetic-environment survey of some U.S. metropolitan areas measured terrestrial emissions within the broad frequency spectrum from 0.4 to 10 GHz. A Cessna 402 commercial aircraft was fitted with both nadir-viewing and horizon-viewing antennas and instrumentation, including a spectrum analyzer, a 35 mm continuous film camera, and a magnetic tape recorder. Most of the flights were made at a nominal altitude of 10,000 feet, and Washington, D. C., Baltimore, Philadelphia, New York, and Chicago were surveyed. The 450 to 470 MHz land-mobile UHF band is especially crowded, and the 400 to 406 MHz space bands are less active. This paper discusses test measurements obtained up to 10 GHz. Sample spectrum analyzer photograhs were selected from a total of 5,750 frames representing 38 hours of data.

Taylor, R. E.↗

Investigation of television transmission using adaptive delta modulation principles

The results are presented of a study on the use of the delta modulator as a digital encoder of television signals. The computer simulation of different delta modulators was studied in order to find a satisfactory delta modulator. After finding a suitable delta modulator algorithm via computer simulation, the results were analyzed and then implemented in hardware to study its ability to encode real time motion pictures from an NTSC format television camera. The effects of channel errors on the delta modulated video signal were tested along with several error correction algorithms via computer simulation. A very high speed delta modulator was built (out of ECL logic), incorporating the most promising of the correction schemes, so that it could be tested on real time motion pictures. Delta modulators were investigated which could achieve significant bandwidth reduction without regard to complexity or speed. The first scheme investigated was a real time frame to frame encoding scheme which required the assembly of fourteen, 131,000 bit long shift registers as well as a high speed delta modulator. The other schemes involved the computer simulation of two dimensional delta modulator algorithms.

Schilling, D. L.↗

A line-source method for aligning on-board and other pinhole SPECT systems

Purpose: In order to achieve functional and molecular imaging as patients are in position for radiation therapy, a robotic multipinhole SPECT system is being developed. Alignment of the SPECT system—to the linear accelerator (LINAC) coordinate frame and to the coordinate frames of other on-board imaging systems such as cone-beam CT (CBCT)—is essential for target localization and image reconstruction. An alignment method that utilizes line sources and one pinhole projection is proposed and investigated to achieve this goal. Potentially, this method could also be applied to the calibration of the other pinhole SPECT systems.Methods: An alignment model consisting of multiple alignment parameters was developed which maps line sources in three-dimensional (3D) space to their two-dimensional (2D) projections on the SPECT detector. In a computer-simulation study, 3D coordinates of line-sources were defined in a reference room coordinate frame, such as the LINAC coordinate frame. Corresponding 2D line-source projections were generated by computer simulation that included SPECT blurring and noise effects. The Radon transform was utilized to detect angles (α) and offsets (ρ) of the line-source projections. Alignment parameters were then estimated by a nonlinear least squares method, based on the α and ρ values and the alignment model. Alignment performance was evaluated as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise, and acquisition geometry. Experimental evaluations were performed using a physical line-source phantom and a pinhole-collimated gamma camera attached to a robot.Results: In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, six alignment parameters (three translational and three rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by the Radon transform, estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution, and detector acquisition geometry. Statistically, the estimation accuracy was significantly improved by using four line sources rather than three and by thinner line-source projections (obtained by better intrinsic detector resolution). With five line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt, and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.Conclusions: Alignment parameters can be estimated using one pinhole projection of line sources. Alignment errors are largely associated with limited accuracy of the Radon transform in determining angles (α) and offsets (ρ) of the line-source projections. This alignment method may be important for multipinhole SPECT, where relative pinhole alignment may vary during rotation. For pinhole and multipinhole SPECT imaging on-board radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical Imaging of Flow Pattern and Phantom

Time-resolved optical imaging technique has been used to image the spatial distribution of small droplets and jet sprays in a highly scattering environment. The snake and ballistic components of the transmitted pulse are less scattered, and contain direct information about the sample to facilitate image formation as opposed to the diffusive components which are due to multiple collisions as a light pulse propagates through a scattering medium. In a time-gated imaging scheme, these early-arriving, image-bearing components of the incident pulse are selected by opening a gate for an ultrashort period of time and a shadowgram image is detected. Using a single shot cooled CCD camera system, the formation of water droplets is monitored as a function of time. Picosecond time-gated image of drop in scattering cells, spray droplets as a function of let speed and gas pressure, and model calcification samples consisted of calcium carbonate particles of irregular shapes ranging in size from 0. 1 to 1.5 mm affixed to a microscope slide have been measured. Formation produced by an impinging jet will be further monitored using a CCD with 1 kHz framing illuminated with pulsed light. The desired image resolution of the fuel droplets is on the 20 pm scale using early light through a highly scattering medium. A 10(exp -6)m displacement from a jet spray with a flow speed of 100 m/sec introduced by the ns grating pulse used in the imaging is negligible. Early ballistic/snake light imaging offers nondestructive and noninvasive method to observe the spatial distribution of hidden objects inside a highly scattering environment for space, biomedical, and materials applications. In this paper, the techniques we will present are time-resolved K-F transillumination imaging and time-gated scattered light imaging. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.

Galland, Pierre A.↗

In Situ Height and Width Estimation of Sorghum Plants from 2.5d Infrared Images

Plant phenotyping, or the measurement of plant traits such as stem width and plant height, is a critical step in the development and evaluation of higher yield biofuel crops. Phenotyping allows biologists to quantitatively estimate the biomass of plant varieties and therefore their potential for biofuel production. Manual phenotyping is costly, time-consuming, and errorprone, requiring a person to walk through the fields measuring individual plants with a tape measure and notebook. In this work we describe an alternative system consisting of an autonomous robot equipped with two infrared cameras that travels through fields, collecting 2.5D image data of sorghum plants. We develop novel image processing based algorithms to estimate plant height and stem width from the image data. Our proposed method has the advantage of working in situ using images of plants from only one side. This allows phenotypic data to be collected nondestructively throughout the growing cycle, providing biologists with valuable information on crop growth patterns. Our approach first estimates plant heights and stem widths from individual frames. It then uses tracking algorithms to refine these estimates across frames and avoid double counting the same plant in multiple frames. The result is a histogram of stem widths and plant heights for each plot of a particular genetically engineered sorghum variety. In-field testing and comparison with human collected ground truth data demonstrates that our system achieves 13% average absolute error for stem width estimation and 15% average absolute error for plant height estimation.

09 BIOMASS FUELS↗