SEARCH · Engineering Papers
Results for “FRAME”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Stationary-Frame Grid-Forming Inverter Control Architectures for Unbalanced Fault-Current Limiting
Not provided.
Spatio-Temporal Feature Exploration in Combined Particle/Volume Reference Frames
Not provided.
Granular Flow in Novel Octet Shape–Based Lattice Frame Material
Moving packed-bed heat exchangers in concentrated solar power (CSP) plants involves heat transfer between heated falling particles and supercritical carbon dioxide. The overall effective thermal conductivity of the moving packed bed and particle-side channel contact resistances are still the bottlenecks in achieving the desirable thermal transport levels. To this end, a novel moving packed bed heat exchanger consisting of an Octet lattice packed between the walls of the particle-side channel is proposed in this study. Granular flow analysis in Octet lattice moving packed bed heat exchanger (OLHX) was conducted through experiments and discrete element method (DEM)-based numerical simulations. The experimental images clearly demonstrated stagnation regions upstream of lattice fibers, void regions downstream of the fiber junctions, and wavy-type unobstructed flow on the lateral sides of the fibers. DEM simulations were successful in capturing all these critical flow phenomena. Larger flow velocities were observed on the lateral sides of the fibers in the simulations. Also, when the particles in the silo were emptied, the final images showed an accumulation of particles on the inter-fiber as well as fiber–channel wall junctions. Moreover, the fiber connections resulted in some regions devoid of particle contact on the channel endwall, which means that these regions would suffer from poor thermal exchange. Finally, the overall mass flowrate increased with increasing porosity for a fixed particle diameter.
Performance characterization of a four-frame nanosecond gated hybrid CMOS image sensor
Explore the source record for details and available documents.
Design and implementation of high magnification framing camera for NIF "ARIANE Light"
Abstract not provided
Effects of spin-lock field direction on the quantitative measurement of spin-lattice relaxation time constant in the rotating frame (T1ρ) in a clinical MRI system
Purpose: To investigate whether the direction of spin-lock field, either parallel or antiparallel to the rotating magnetization, has any effect on the spin-lock MRI signal and further on the quantitative measurement of T1ρ, in a clinical 3 T MRI system. Methods: The effects of inverted spin-lock field direction were investigated by acquiring a series of spin-lock MRI signals for an American College of Radiology MRI phantom, while the spin-lock field direction was switched between the parallel and antiparallel directions. The acquisition was performed for different spin-locking methods (i.e., for the single- and dual-field spin-locking methods) and for different levels of clinically feasible spin-lock field strength, ranging from 100 to 500 Hz, while the spin-lock duration was varied in the range from 0 to 100 ms. Results: When the spin-lock field was inverted into the antiparallel direction, the rate of MRI signal decay was altered and the T1ρ value, when compared to the value for the parallel field, was clearly different. Different degrees of such direction-dependency were observed for different spin-lock field strengths. In addition, the dependency was much smaller when the parallel and the antiparallel fields are mixed together in the dual-field method. Conclusions: The spin-lock field direction could impact the MRI signal and further the T1ρ measurement in a clinical MRI system.
Enhanced phagocytosis and complement-mediated killing of Mannheimia haemolytica serotype 1 following in-frame CMP-sialic acid synthetase ( neuA ) gene deletion
ABSTRACT Mannheimia haemolyticais the most significant bacterial pathogen associated with the bovine respiratory disease complex. Although sialic acid is a known virulence factor in other members of Pasteurellaceae, such asHistophilus somniandPasteurella multocida, the significance of sialic acid to the virulence ofM. haemolyticais currently unknown. Therefore, the role of sialic acid as a virulence determinant ofM. haemolyticawas investigated by constructing an in-frameneuA[CMP-N-acetylneuraminic acid (Neu5Ac/sialic) synthetase] mutant, which was shown by high-performance anion exchange chromatographic analysis (HPAEC) to be devoid of sialic acid on the lipopolysaccharide (LPS). Both theneuAmutant and wild-type parent strains exhibited similar growth rates in the growth curve assay. Real-time qPCR and ELISA evaluation showed no differences in proinflammatory cytokine expressions (IL-1β, IL-6, and IL-8) between theneuAmutant and parent strain when peripheral blood mononuclear cells were incubated with LPS. Interestingly, theneuAmutant was three to four logs more sensitive to a whole-blood bacterial killing assay than the parent strain. Similar results were also observed in plasma and serum bacterial killing assays. Flow cytometry analyses showed higher uptake ofneuAmutant by phagocytes, compared to the parent strain, in the whole-blood phagocytosis assay; however, no difference in reactive oxygen species production in neutrophils or monocytes was detected for either strain. Taken together, these results indicate that sialylation ofM. haemolyticaLPS plays a vital role in reducing complement-mediated and phagocytic killing. IMPORTANCE The Gram-negative coccobacillusMannheimia haemolyticais a natural inhabitant of the upper respiratory tract in ruminants and the most common bacterial agent involved in bovine respiratory disease complex development. Key virulence factors harbored byM. haemolyticaare leukotoxin, lipopolysaccharide, capsule, adhesins, and neuraminidase which are involved in evading innate and adaptive immune responses. In this study, we have shown that CMP-sialic acid synthetase (neuA) is necessary for the incorporation of sialic acid onto the membrane, and inactivation ofneuAresults in increased phagocytosis and complement-mediated killing ofM. haemolytica,thus demonstrating that sialylation contributes to the virulence ofM. haemolytica.
Double-differential spectra of the secondary particles in the frame of pre-equilibrium model
An approach was developed to describe the double-differential spectra of secondary particles formed in heavy-ion reactions. Griffin model of nonequilibrium processes was used to account for the nonequilibrium stage of the compound system formation. Simulation of de-excitation of the compound system was carried out using the Monte-Carlo method. Analysis of the probability of neutron, proton, and {alpha}-particle emission was performed both in equilibrium, and in the pre-equilibrium stages of the process. Fission and {gamma}-ray emission were also considered after equilibration. The analysis of the experimental data on the double-differential cross sections of p, {alpha} particles for the {sup 16}O + {sup 116}Sn reaction at the oxygen energy E = 130 and 250 MeV were performed.
Single-frame far-field diffractive imaging with randomized illumination
Contains a transmission ptychography dataset collected from a chrome on glass Siemens star under optical illumination. The probe is generated by a randomized zone plate under illumination from a spatially filtered green laser. A single diffraction pattern was removed from the dataset and reported in a separate cxi file. In addition, a single exposure collected after manually defocusing the probe is reported. The ptychography dataset is used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.
Single-frame far-field diffractive imaging with randomized illumination
Contains two transmission ptychography datasets, one collected from a Siemens star, and the second from an Fe/Gd multilayer. Both samples are under illumination from the same randomized zone plate. Each dataset has a single diffraction pattern removed, and these patterns are reported in a separate cxi file. Either ptychography dataset can be used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.
Short Read Reading-Frame Predictors are not Created Equal: Sequence Error Causes Loss of Signal
Abstract not provided