Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINGERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Release of Bacterial Spores from the Inner Walls of a Stainless Steel Cup Subjected to Thermal Stresses and Mechanical Shock

The release and fallout of particulates from surfaces afforded thermal or impact stress is of concern for control of contamination of Mars from planetary landing vehicles. A metal vessel contaminated by aerosols of spores was used as a model system and the fallout of spores as affected by various mechanisms was examined. Thermal stresses simulating those expected on the Mars lander dislodged approximately .01% of the aerosol deposited surface burden as did a landing shock of 8 to 10G deceleration. Spores imprinted by finger or swab contact yielded similar results. In all cases where repeated cycling of temperature, motion, or shock were employed the majority of fallout occurred in the first cycle. Particles released from the surface were predominantly in the size range 1 to 5 microns.

Wolochow, H.↗

Transparent switchboard

A tin oxide coating is formed on a plate of glass and the coating is then etched away from the glass in thin lines to form separate electrical conductors which extend to one end of the plate and connect to either a vertical (column) or horizontal (row) position sensing SCR circuit. A thin transparent insulating coating is formed over the oxide layer except at selected touch points which are positioned in a matrix pattern of vertical columns and horizontal rows. Touching one of these points with a finger bridges the thin line between adjacent conductors to activate trigger circuits in the particular row and column sensing circuits associated with the point touched. The row and column sensing circuits are similar and are powered with a low frequency, ac voltage source. The source for the row circuits is 180 out of phase with the source for the column circuits so that one circuit acts as ground for the other during half of the supply voltage cycle. The signals from the sensing circuits are input to a logic circuit which determines the presence of a valid touch, stores a binary matrix number associated with the touched point, signals a computer of the presence of a stored number and prevents storage of a new number before receiving an enable signal from the computer.

Rasmussen, H. P.↗

Therapeutic hand-exercising device with cycling pressure value

Device exercises hands of persons whose fingers are generally straight and need to be flexed inward toward palms of hands. Device is extremely simple in design, which reduces costs, and fits all hand sizes. Patient can instantly free hand from device by pulling flap free from wrist of straps.

Barthlome, D. E.↗

Integrated circuit package with lead structure and method of preparing the same

A beam-lead integrated circuit package assembly including a beam-lead integrated circuit chip, a lead frame array bonded to projecting fingers of the chip, a rubber potting compound disposed around the chip, and an encapsulating molded plastic is described. The lead frame array is prepared by photographically printing a lead pattern on a base metal sheet, selectively etching to remove metal between leads, and plating with gold. Joining of the chip to the lead frame array is carried out by thermocompression bonding of mating goldplated surfaces. A small amount of silicone rubber is then applied to cover the chip and bonded joints, and the package is encapsulated with epoxy resin, applied by molding.

Kennedy, B. W.↗

Development of an externally powered prosthetic hook for amputees

The powered hook with trigger finger appears to be a useful adaptation of a terminal device for an amputee when performing vocational activities involving the use of a powered tool requiring a trigger control. The proportional control system includes transducers and amplifiers and appears to have widespread application for control of any external power, whether it be in the orthotic or prosthetic field.

Karchak, A., Jr.↗

Development and testing of laser Doppler system components for wake vortex monitoring. Volume 1: Scanner development, laboratory and field testing and system modeling

A servo-controlled range/elevation scanner for the laser Doppler velocimeter (LDV) was developed and tested in the field to assess its performance in detecting and monitoring aircraft trailing vortices in an airport environment. The elevation scanner provides a capability to manually point the LDV telescope at operator chosen angles from 3.2 deg. to 89.6 deg within 0.2 deg, or to automatically scan the units between operator chosen limits at operator chosen rates of 0.1 Hz to 0.5 Hz. The range scanner provides a capability to manually adjust the focal point of the system from a range of 32 meters to a range of 896 meters under operator control, or to scan between operator chosen limits and at rates from 0.1 Hz to 6.9 Hz. The scanner controls are designed to allow simulataneous range and elevation scanning so as to provide finger scan patterns, arc scan patterns, and vertical line scan patterns. The development and testing of the unit is discussed, along with a fluid dynamic model of the wake vortex developed in a laser Doppler vortex sensor simulation program.

Wilson, D. J.↗

Hand tremor and activity sensor

System detects hand tremor and activity and transmitting signals over distance of at least 3 meters to receiver system. Designed for use in studies of effect of fatigue on individual's judgement or reaction time, sensor is installed within mounting of finger-ring; no external wiring or power source is needed.

Konigsberg, E.↗

Ultrasonic bone densitometer

A device, for measuring the density of a bone structure so as to monitor the calcium content, is described. A pair of opposed spaced ultrasonic transducers are held within a clamping apparatus closely adjacent the bone being analyzed. These ultrasonic transducers incude piezoelectric crystals shaped to direct signals through the bone encompassed in the heel and finger of the subject being tested. A pulse generator is coupled to one of the transducers and generates an electric pulse for causing the transducers to generate an ultrasonic sound wave which is directed through the bone structure to the other transducer. An electric circuit, including an amplifier and a bandpass filter couples the signals from the receiver transducer back to the pulse generator for retriggering the pulse generator at a frequency proportional to the duration that the ultrasonic wave takes to travel through the bone structure being examined.

Hoop, J. M.↗

Phase 2, 3 and 4 8 psi pressure glove

The feasibility of providing a high pressure, very mobile and reliable space suit glove system is demonstrated. A 'soft' toroidal wrist joint assembly was developed. A representative Kevlar and steel wrist section was tested and proved the useful lifetime to be in excess of 1,000,000 cycles. Improved comfort was accomplished by increasing the first finger metacarpal dimensions. Recommendations concern design refinements, and EVA configuration.

Elkins, W.↗

Modeling and measuring limb fine-motor unsteadiness

Fine-motor unsteadiness its properties, conceptual and analytical models, and experimental measurements is examined. Based on a data review, the tentative model derived includes: neuromuscular system, grip interface, and control system dynamic elements. The properties of this model change with muscle tension and match a wide group of extant data. A simple experiment was performed to investigate the amplitude/force relationships of the tremor mode. As the finger-pull force increased from 5 to 20 Newtons, the tremor mode frequency for a given individual stayed within roughly + or - 1 Hz over a range from 9-12 Hz, while the average magnitude of the rms tremor acceleration increased tenfold. A standardized test for making such measurements is given and applications in the fields of psychophysiological stress and strain measurements are mentioned.

Magdaleno, R. E.↗

EV space suit gloves (passive)

A pair of pressure and thermal insulating overgloves to be used with an Extravehicular (EV) suit assembly was designed, developed, fabricated, and tested. The design features extensive use of Nomex felt materials in lieu of the multiple layer insulation formerly used with the Apollo thermal glove. The glove theoretically satisfies all of the thermal requirements. The presence of the thermal glove does not degrade pressure glove tactility by more than the acceptable 10% value. On the other hand, the thermal glove generally degrades pressure glove mobility by more than the acceptable 10% value, primarily in the area of the fingers. Life cycling tests were completed with minimal problems. The thermal glove/pressure glove ensemble was also tested for comfort; the test subjects found no problems with the thermal glove although they did report difficulties with pressure points on the pressure glove which were independent of the thermal glove.

Fletcher, E. G.↗

Silicon Schottky photovoltaic diodes for solar energy conversion

Various factors in Schottky barrier solar cell fabrication are evaluated in order to improve understanding of the current flow mechanism and to isolate processing variables that improve efficiency. Results of finger design, substrate resistivity, surface finishing and activation energy studies are detailed. An increased fill factor was obtained by baking of the vacuum system to remove moisture.

Anderson, W. A.↗

Enhancement and evaluation of Skylab photography for potential land use inventories, part 1

The author has identified the following significant results. Three sites were evaluated for land use inventory: Finger Lakes - Tompkins County, Lower Hudson Valley - Newburgh, and Suffolk County - Long Island. Special photo enhancement processes were developed to standardize the density range and contrast among S190A negatives. Enhanced black and white enlargements were converted to color by contact printing onto diazo film. A color prediction model related the density values on each spectral band for each category of land use to the spectral properties of the various diazo dyes. The S190A multispectral system proved to be almost as effective as the S190B high resolution camera for inventorying land use. Aggregate error for Level 1 averaged about 12% while Level 2 aggregate error averaged about 25%. The S190A system proved to be much superior to LANDSAT in inventorying land use, primarily because of increased resolution.

Hardy, E. E.↗

Demonstration of the frequency offset errors introduced by an incorrect setting of the Zeeman/magnetic field adjustment on the cesium beam frequency standard

The fine frequency setting of a cesium beam frequency standard is accomplished by adjusting the C field control with the appropriate Zeeman frequency applied to the harmonic generator. A novice operator in the field, even when using the correct Zeeman frequency input, may mistakenly set the C field to any one of seven major Beam I peaks (fingers) represented by the Ramsey curve. This can result in frequency offset errors of as much as 2.5 parts in ten to the tenth. The effects of maladjustment are demonstrated and suggestions are discussed on how to avoid the subtle traps associated with C field adjustments.

Kaufmann, D. C.↗

Accelerometer telemetry system

An accelerometer telemetry system incorporated in a finger ring is used for monitoring the motor responses of a subject. The system includes an accelerometer, battery, and transmitter and provides information to a remote receiver regarding hand movements of a subject wearing the ring, without the constraints of wires. Possible applications include the detection of fatigue from the hand movements of the wearer.

Konigsberg, E.↗

Reduction of losses in low-frequency /2 MHz/ surface-wave delay line by outgassing

Surface waves are attenuated by a fluid or gas surrounding the surface of propagation, an effect caused by frictional losses determined by the fluid or gas viscosity and by the emission of compression waves into the environment. The paper reports a large reversible reduction in attenuation of surface waves at frequencies as low as 2 MHz by outgassing treatments of some materials, suggesting that at such frequencies vacuum encapsulation is a desirable procedure. Outgassing experiments were performed on a delay line constructed from high-density p.z.t.-8 (lead-zirconate-titanate). The delay line configuration was a slab waxed onto a metal base with coaxial connectors mounted near and connected by gold-wire leads to the interdigital finger sets. Output signal enhancements by as much as 8 dB were achieved after overnight evacuation at 10 to the -2 torr at room temperature.

Tittmann, B. R.↗

Mechanical sequencer

A mechanical sequencer having a rotatable drive shaft is described. The drive shaft has a spline formed thereon. A freely rotatable shaft contains a plurality of rollers positioned thereon, the axis of the freely rotatable shaft having an axis parallel to and offset from the axis of the drive shaft. A drive fitting has an opening therein, the drive fitting being positioned on the drive shaft spline for rotating the fitting with the shaft. A finger is formed integral with the drive fitting for enabling the fitting to move the rollers and the freely rotatable shift. A crank structure is positioned in a plane in a plane perpendicular to the axis of the drive shaft and the freely rotatable shaft. The crank structure has a drive shaft opening through which the shaft passes. The crank structure further contains a slot into which the freely rotatable shaft and one of the rollers extends for driving the crank structure during movement of the freely rotatable shaft.

Appleberry, W. T.↗

Market study: Tactile paging system

A market survey was conducted regarding the commercialization potential and key market factors relevant to a tactile paging system for deaf-blind people. The purpose of the tactile paging system is to communicate to the deaf-blind people in an institutional environment. The system consists of a main console and individual satellite wrist units. The console emits three signals by telemetry to the wrist com (receiving unit) which will measure approximately 2 x 4 x 3/4 inches and will be fastened to the wrist by a strap. The three vibration signals are fire alarm, time period indication, and a third signal which will alert the wearer of the wrist com to the fact that the pin on the top of the wrist is emitting a morse coded message. The Morse code message can be felt and recognized with the finger.

Source record↗