Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIBER OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Atomic force microscopy deep trench and sidewall imaging with an optical fiber probe

We report a method to measure critical dimensions of micro- and nanostructures using the atomic force microscope (AFM) with an optical fiber probe (OFP). This method is capable of scanning narrow and deep trenches due to the long and thin OFP tip, as well as imaging of steep sidewalls with unique profiling possibilities by laterally tilting the OFP without any modifications of the optical lever. A switch control scheme is developed to measure the sidewall angle by flexibly transferring feedback control between the Z- and Y-axis, for a serial scan of the horizontal surface (raster scan on XY-plane) and sidewall (raster scan on the YZ-plane), respectively. In experiments, a deep trench with tapered walls (243.5 μm deep) and a microhole (about 14.9 μm deep) have been imaged with the orthogonally aligned OFP, as well as a silicon sidewall (fabricated by deep reactive ion etching) has been characterized with the tilted OFP. Moreover, the sidewall angle of TGZ3 (AFM calibration grating) was accurately measured using the switchable scan method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization-Controlled Topological Charge Inversion of Optical Vortices in Multielliptical Optical Fibers

Analytical expressions for higher-order modes with azimuthal number |ℓ|≥ 2and their propagation constants for multielliptical optical fibers exhibiting a torsional mechanical stress are obtained in the vicinity of the resonance twist-pitch values. It is demonstrated that the resonance modes represent a superposition of two optical vortices with identical circular polarization and opposite signs of the topological charge. The effect of topological-charge inversion of the output optical vortex controlled by a change of sign of the circular polarization of the input beam is predicted. This effect paves the way to creating a logical CNOT element based on multielliptical fibers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-Time Monitoring of Temperature Rises of Energized Transformer Cores With Distributed Optical Fiber Sensors

Real-time temperature mapping that solves local overheating problems is important for obtaining an optimized thermal design for high-efficiency power transformers. Internal temperature monitoring of operating power transformers can also be leveraged for asset monitoring applications targeting at fault detection enabling condition-based maintenance. Transformers present a variety of challenging sensing environments such as high levels of electromagnetic interference and limited space for conventional sensors to operate. Immersion of power transformers in insulation oils for thermal management during operation and the presence of relatively large and time-varying electrical and occasional magnetic fields make sensing technologies requiring electrical wires or active power at sensing locations highly undesirable. In this work, we investigate thermal response of a standard telecom fiber instrumented on compact transformer cores by using an optical frequency-domain reflectometry scheme. As a result, correlation between conventional temperature sensing methods and fiber-optic sensing results as well as tradeoffs between spatial resolution and temperature measurement accuracy is discussed and spatially resolved real-time monitoring of temperatures in energized transformers is experimentally demonstrated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fiber optics in photography.

Fabrication of improved Focons and field flatteners and evaluation of optical performance in terms of modulation transfer function /MTF/, VIGNETTING and T-number measurements

OPTICAL EQUIPMENT↗

Stabilizing Fiber-Optic Transmission Lines

Voltage-controlled optical phase shifter is key. Optical phase shifter stabilizes propagation delay of fiber-optic transmission line by compensating for temperature and pressure effects. Applicable to phased array antenna systems and very-long-baseline interferometer distribution systems.

Lutes, G. F.↗

Flight Tests on a Fiber Optic Temperature Sensor

For aircraft engine control, one key parameter to detect on an airplane is the exhaust gas temperature (EGT). Presently, thermocouples are used to perform this measurement. These electrical sensors perform adequately; however, fully utilizing the benefits of optical sensors requires replacing electrical architectures with optical architectures. Part of this requires replacing electrical sensors with optical sensors, such as the EGT sensor chosen for these tests. The objective of the development and testing of this prototype sensor system was to determine the feasibility of operating an optical sensor in a hostile aircraft environment. The fiber optic sensor system was developed to measure temperatures from 20C to 600C in an aircraft environment and was utilized to monitor the EGT of an OV-10D aircraft engine. The sensor has successfully flown over 50 hours and proven to be immune to surface deterioration of the optical element (located inside the sensor head) and able to withstand and operate in normal and sustained severe flight conditions where forces on the airplane exceeded 4 g's. Potential commercial uses for this sensor include monitoring temperature for aeropropulsion system control, military vehicle and naval engine control, conventional and nuclear power plant monitoring and industrial plan monitoring where EMI issues are critical.

Tuma, Margaret L.↗

Gamma and x-ray irradiation effects on different Ge and Ge/F doped optical fibers

We performed electron paramagnetic resonance (EPR) measurements on γ and X ray irradiated Ge doped and Ge/F co-doped optical fibers. We considered three different drawing conditions (speed and tension), and for each type of drawing, we studied Ge and Ge/F doped samples having Ge doping level above 4% by weight. The EPR data recorded for the γ ray irradiated fibers confirm that all the samples exhibit a very close radiation response regardless of the drawing conditions corresponding to values used for the production of specialty fibers. Furthermore, as for the X irradiated materials, in the γ ray irradiated F co-doped fibers, we observed that the Ge(1) and the Ge(2) defects generation is unchanged, whereas it was enhanced for the E'Ge. In the various fibers, the comparison of the γ and X-ray induced concentrations of these kinds of Ge related defects indicates that the two irradiations induce similar effects regardless of the different employed dose rates and sources. Confocal microscopy luminescence results show that the starting content of the Germanium Lone Pair Center (GLPC) is neither strongly affected by the Ge content nor by the drawing conditions, and we consider the similarity of the GLPC content as key factor in determining many of the above reported similarities.

36 MATERIALS SCIENCE↗

WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry

Purpose: Microbeam Radiation Therapy (MRT) is an experimental radiation therapy that has demonstrated a higher therapeutic ratio than conventional radiation therapy in animal studies. There are several roadblocks in translating the promising treatment technology to clinical application, one of which is the lack of a real-time, high-resolution dosimeter. Current clinical radiation detectors have poor spatial resolution and, as such, are unsuitable for measuring microbeams with submillimeter-scale widths. Although GafChromic film has high spatial resolution, it lacks the real-time dosimetry capability necessary for MRT preclinical research and potential clinical use. In this work we have demonstrated the feasibility of using a nanoscintillator fiber-optic detector (nanoFOD) system for real-time MRT dosimetry. Methods: A microplanar beam array is generated using a x-ray research irradiator and a custom-made, microbeam-forming collimator. The newest generation nanoFOD has an effective size of 70 µm in the measurement direction and was calibrated against a kV ion chamber (RadCal Accu-Pro) in open field geometry. We have written a computer script that performs automatic data collection with immediate background subtraction. A computer-controlled detector positioning stage is used to precisely measure the microbeam peak dose and beam profile by translating the stage during data collection. We test the new generation nanoFOD system, with increased active scintillation volume, against the previous generation system. Both raw and processed data are time-stamped and recorded to enable future post-processing. Results: The real-time microbeam dosimetry system worked as expected. The new generation dosimeter has approximately double the active volume compared to the previous generation resulting in over 900% increase in signal. The active volume of the dosimeter still provided the spatial resolution that meets the Nyquist criterion for our microbeam widths. Conclusion: We have demonstrated that real-time dosimetry of MRT microbeams is feasible using a nanoscintillator fiber-optic detector with integrated positioning system.

60 APPLIED LIFE SCIENCES↗

Enhanced backscatter and unsaturated blue wavelength shifts in F-doped fused silica optical fibers exposed to extreme neutron radiation damage

Amorphous fused silica (a-SiO 2 ) optical fibers, with and without inscribed Bragg gratings, were interrogated using infrared (~1550 nm) optical backscatter reflectometry during ~25 days of intense neutron irradiation to a fast (energy > 0.1 MeV) neutron fluence of ~10 21 n/cm 2 , or ~1.5 atomic displacements per atom. The reflected light amplitudes in Ge-doped core telecommunications fiber dropped below detection limits (>15 dB attenuation) within 3 days of irradiation (~10 20 fast n/cm 2 ). Here, amplitudes from a pure silica core, F-doped silica cladding fiber reached equilibrium levels ~1.5–2 dB higher than pre-irradiation values, whereas Bragg gratings inscribed in the same fiber using a femtosecond laser (point-by-point method) suffered > 45 dB attenuation. Blue wavelength shifts were initially consistent with previous radiation-induced compaction models but increased linearly with increasing neutron fluence (no evidence of saturation) beyond 10 20 n/cm 2 and exceeded 0.6%, which corresponds to >1,000 °C drift if used to measure temperature changes.

36 MATERIALS SCIENCE↗

High-performance single-photon generation with commercial-grade optical fiber

High-quality quantum sources are of paramount importance for the implementation of quantum technologies. We present here a heralded single-photon source based on commercial-grade polarization-maintaining optical fiber. The heralded photons exhibit a purity of at least 0.84 and an unprecedented heralding efficiency into a single-mode fiber of 85%. The birefringent phase-matching condition of the underlying four-wave mixing process can be controlled mechanically to optimize the wavelength tuning needed for interfacing multiple sources, as is required for large-scale entanglement generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗

Holograms for laser diode: Single mode optical fiber coupling

The low coupling efficiency of semiconductor laser emissions into a single mode optical fibers place a severe restriction on their use. Associated with these conventional optical coupling techniques are stringent alignment sensitivities. Using holographic elements, the coupling efficiency may be increased and the alignment sensitivity greatly reduced. Both conventional and computer methods used in the generation of the holographic couplers are described and diagrammed. The reconstruction geometries used are shown to be somewhat restrictive but substantially less rigid than their conventional optical counterparts. Single and double hologram techniques are examined concerning their respective ease of fabrication and relative merits.

Fuhr, P. L.↗

SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60 gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.

07 ISOTOPE AND RADIATION SOURCES↗

TRUST Sensors in Environments: Fiber Optic Displacement (SE-FOD) Report, Release FY24

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. This work uses and provides feedback on analysis tools and experimental results databases for efficient and responsive engineering which are currently under development. Under the TRUST work package, there are five testbeds and their associated engineering analysis baseline models (EABMs): 1. Contact Thermal Conductivity (CTC), 2. Nonlinear Dynamics (ND), 3. Sensors in Environments: Accelerometers (SE-A), 4. Sensors in Environments: Fiber Optic Displacement Gauges (SE-FOD), and 5. Sensors in Environments: Thermocouples (SE-TC). The TRUST project uses single-feature testbeds to quantify uncertainties in specific models and experiments and to identify capability development needs that can help to reduce these uncertainties. Each testbed is designed, configured, and tested in collaboration with groups with design and experimental capability: E-14 and MPA-CINT. The complementary simulations are conducted using W-13 analysis tools and stored in model repositories with plans for incremental progress toward EABM requirements. W-13 extends and exercises the testbed simulations in collaboration with experimentalists for uncertainty quantification of current and future materials, geometries, and environments. Additionally, TRUST is intended to provide engineers in W-13 and E-14 with experience in both numerical simulations and experimental methods through cross-discipline collaborations. Following the introduction to the TRUST project, the remainder of this report focuses on experimental, modeling and simulation, and analysis efforts conducted in FY24 relevant to the TRUST Sensors in Environments: Fiber Optic Displacement (SE-FOD) testbed.

42 ENGINEERING↗

Arc detector uses fiber optics

Arc detector for protecting high-power microwave klystron oscillators uses fiber optics connected to remote solid-state light-sensing circuits. Detector is more reliable, smaller, and sensitive than other systems that locate detector in waveguide.

Finnegan, E. J.↗

Fiber optic sensors for military, industrial and commercial applications

Four examples of specific fiber optic sensor system designs, each of which demonstrates a different optical modulation format, are described. The birefrigent temperature transducer illustrates direct digital signal modulation. The temperature/pressure dependent semiconductor filter illustrates high-pass optical wavelength signal encoding. The coupled polarized-mode transducer shows how a solid-state sensor can produce narrow-bandpass optical wavelength signal encoding. The luminescent temperature sensor illustrates a way to construct a solid state sensor in order to produce pulse width modulation of an optical signal.

James, K. A.↗

Fiber-optic rotation sensor technology

A concept for an all-waveguide fiber-optic rotation sensor is discussed, and the results of preliminary tests of key elements are described. A single channel waveguide coupler design provides the functions of an optical switch, a 3-dB beam splitter, a phase retarder, and a signal modulator, all of which may be formed on the same chip and interconnected by channel single-mode waveguides. Preliminary test results for the waveguide coupler and for a rotation sensor without the coupler are presented. Signal processing, polarization control, and interconnection of the waveguide components are discussed.

Goss, W. C.↗

Polarization preserving single mode fiber optic coupler

A technique is described for fabrication of etched single mode fiber optical waveguide couplers which preserve the polarization state to within 0.0001. The coupling ratio is tunable over a broad range (0-9 percent) during fabrication. Back-coupling is less than 0.001, insertion loss is less than 1.5 dB, and coupling ratio thermal coefficient is about 1 percent per degree C.

Nelson, M. D.↗