Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Winds of Change: Assessing Wind Energy Efficiency in Complex Terrain

In 2015, the Department of Energy (DOE) and the National Oceanic and Atmospheric Administration (NOAA) initiated a four-year study, the Second Wind Forecast Improvement Project (WFIP2), which aims to improve the accuracy of meteorological models that forecast wind speed in complex terrain for applications in wind energy (Wilczak et al.2019). As a part of WFIP2, a dataset was collected in the Columbian River and Basin regions of Oregon and Washington which led to significant wind forecast model improvements (Kenyon et al.2018). Similar to the observations performed in Oregon and Washington, Light Detection and Ranging (LiDAR) systems were deployed at three observation points at the Lawrence Livermore National Laboratory Site 300 Experimental Test Site as part of WFIP2. Site 300, located in the rolling hills approximately ten kilometers from the Altamont Pass Wind Resource Area, represents a second complex terrain location for validating and evaluating the model improvements made using the original Columbian River dataset. The three LiDARsystems continuously collected wind speed and direction data at heights ranging from 10 meters to 150 meters. The data were used to better understand how wind flow is modified over hills and valleys in the Altamont Pass Wind Resource Area and to determine the optimal hub height for new turbine installations in the region. We observed five popular turbine models that are installed in the Altamont Wind Resource Area Using the collected data and comparisons of existing turbine models in the area, the most efficient turbine model for the Altamont Wind ResourceArea based on power output was determined to be the Mitsubishi 1.0MW. Future work related to this research includes further comparing turbine models based on factors including overall cost and effects on wildlife as well as determining optimal spacing between turbine units.

17 WIND ENERGY↗

Energy efficient integrated photonic systems based on inverse design

The energy footprint of modern information processing and communications systems is immense and utilizes a significant fraction of total global energy usage. Data centers alone consume over 70 billion kilowatt-hours per year. Much of this energy usage is intrinsic to the use of electronic wiring, making optical-based technologies a necessary and promising route to mitigating energy consumption in short- to medium-distance communication links. In this project, we developed and implemented a framework for the design of optical components, based on machine learning, which enables optical components relevant to optical information processing to be realized at their physical performance limits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation of the outdoor energy efficiency of an autonomous solar kit based on meteorological data for a site in Central Europe

This contribution analyzes the energy provided by a solar kit dedicated to autonomous usage and installed in Central Europe (Longitude 6.10°; Latitude 49.21° and Altitude 160 m) by using the simulation software PVSYST. We focused the analysis on the effect of temperature and solar irradiation on the I-V characteristic of a commercial PV panel. We also consider in this study the influence of charging and discharging the battery on the generator efficiency. Meteorological data are integrated into the simulation software. As expected, the solar kit provides an energy varying all along the year with a minimum in December. In the proposed approach, we consider this minimum as the lowest acceptable energy level to satisfy the use. Thus for the other months, a lost in the available renewable energy exists if no storage system is associated.

14 SOLAR ENERGY↗

The Energy Efficiency Potential of Cloud-Based Software: A U.S. Case Study

The energy use of data centers is a topic that has received much attention, given that data centers currently account for 1-2% of global electricity use. However, cloud computing holds great potential to reduce data center energy demand moving forward, due to both large reductions in total servers through consolidation and large increases in facility efficiencies compared to traditional local data centers. However, analyzing the net energy implications of shifts to the cloud can be very difficult, because data center services can affect many different components of society’s economic and energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of stochastic algorithms for financial mathematics problems from point of view of energy-efficiency

The recent developments in the area of high-performance computing are driven not only by the desire for ever higher performance but also by the rising costs of electricity. The use of various types of accelerators like GPUs, Intel Xeon Phi has become mainstream and many algorithms and applications have been ported to make use of them where available. In Financial Mathematics the question of optimal use of computational resources should also take into account the limitations on space, because in many use cases the servers are deployed close to the exchanges. In this work we evaluate various algorithms for option pricing that we have implemented for different target architectures in terms of their energy and space efficiency. Since it has been established that low-discrepancy sequences may be better than pseudorandom numbers for these types of algorithms, we also test the Sobol and Halton sequences. We present the raw results, the computed metrics and conclusions from our tests.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot Humid Climate

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30%-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combining gait optimization with passive system to increase the energy efficiency of a humanoid robot walking movement

There are several approaches to create the Humanoid robot gait planning. This problem presents a large number of unknown parameters that should be found to make the humanoid robot to walk. Optimization in simulation models can be used to find the gait based on several criteria such as energy minimization, acceleration, step length among the others. The energy consumption can also be reduced with elastic elements coupled to each joint. The presented paper addresses an optimization method, the Stretched Simulated Annealing, that runs in an accurate and stable simulation model to find the optimal gait combined with elastic elements. Final results demonstrate that optimization is a valid gait planning technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Data-Driven Analysis Tool Plays Critical Role in Climate Neutral Buildings: Improving energy efficiency and reducing emissions

A new web application that advances the science of data-driven, remote building energy analysis to increase the speed and scale of retrofits worldwide could play a key role in reducing greenhouse gas (GHG) emissions and meeting the Paris Agreement's targets. Here, the multi-award-winning Building Efficiency Targeting Tool for Energy Retrofits (BETTER) is a public access web application (better.lbl.gov) sponsored by the U.S. Department of Energy (DOE) and developed by Lawrence Berkeley National Laboratory (Berkeley Lab) and Johnson Controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fort Devens: Cold Climate, Energy-Efficient, Market-Rate Townhomes

In 2009, Mass Development issued an RFQ and subsequent RFP for teams to develop moderately priced high-efficiency homes on two sites within the Devens Regional Enterprise Zone. MassDevelopment, a Massachusetts agency that owns the Devens site (formerly Fort Devens Army Base, in Harvard, Massachusetts), set a goal of producing a replicable example of current and innovative sustainable building practices with a near-zero energy potential. Metric Development, as primary developer and construction manager, formed one of the successful teams that included CARB and Cambridge Seven Architects (C7A).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fort Devens: Cold Climate, Energy-Efficient, Market-Rate Townhomes

In 2009, Mass Development issued a RFP for teams to develop moderately priced high-efficiency homes on two sites within the Devens Regional Enterprise Zone. MassDevelopment, a Massachusetts agency that owns the Devens site (formerly Fort Devens Army Base, in Harvard, Massachusetts), set a goal of producing a replicable example of current and innovative sustainable building practices with a near-zero energy potential. Metric Development, as primary developer and construction manager, formed one of the successful teams that included CARB and Cambridge Seven Architects (C7A). This report describes the development of high performance, affordable, and replicable designs developed by the team in test homes and plans to move forward with the next buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗