GaLnAsP Solar Cells Grown by Hydride Vapor Phase Epitaxy for One-Sun & Low-Concentration III-V/Si Photovoltaics

Dynamic hydride vapor phase epitaxy (D-HVPE) has recently reemerged as a low-cost alternative to metalorganic chemical vapor deposition (MOCVD) for the growth of highefficiency III-V solar cells. Quaternary GaInAsP solar cells in the bandgap range of ~1.6-1.8 eV are promising top-cell candidates for III-V/Si tandem solar cells. In this work, we report on the development of lattice-matched GaInAsP (Eg~1.66 eV) solar cells grown via low-cost HVPE at very high growth rates of ~0.7 um/min (~42 um/h). We demonstrate for the first time HVPE grown passivated GaInAsP homojunction solar cells that show substantial improvement in the short-wavelength photoresponse attributed to the incorporation of a GaInP window layer. The heterointerfaces in these multilayer devices were characterized by transmission electron microscopy. The best device achieved a certified one-sun efficiency of 18.7% under AM1.5G, demonstrating the viability of HVPE to grow multilayered structures comprising ternary and quaternary alloys. This work represents a promising step towards low-cost III-V/Si tandem photovoltaics with one-sun efficiencies exceeding 30%.

14 SOLAR ENERGY↗

On modeling of chemical stimulation of an enhanced geothermal system using a high pH solution with chelating agent

Dissolution of silica and calcite in the presence of a chelating agent (NTA) at a high pH was successfully demonstrated in laboratory experiments using a high-temperature flow reactor. (Note that the term 'silica' used here includes amorphous silica, quartz, and silicate glass bead). The mineral dissolution and associated porosity enhancement in the experiments were reproduced by reactive transport modeling using TOUGHREACT. The chemical stimulation method was applied by numerical modeling to a field geothermal injection well system to investigate its effectiveness. Parameters applicable to the quartz monzodiorite unit at the Enhanced Geothermal Systems (EGS) site at Desert Peak (Nevada) were used. Results indicate that the injection of a high pH chelating solution results in dissolution of both calcite and plagioclase, while avoiding precipitation of calcite at high temperature conditions. Consequently reservoir porosity and permeability can be enhanced especially near the injection well. Injection at a lower temperature of 120 C (over 160 C in the base-case) results in a porosity increase that is smaller close to the injection point, but extends to a larger radial distance. A slower kinetic rate results in less aggressive mineral dissolution close to the injection point and larger extent along the flow path, which is favorable for chemical stimulation.

54 ENVIRONMENTAL SCIENCES↗

Topological controls on aluminosilicate glass dissolution: Complexities induced in hyperalkaline aqueous environments

Abstract Fly ash, an aluminosilicate composite consisting of disordered (major) and crystalline (minor) compounds, is a low‐carbon alternative that can partially replace ordinary portland cement (OPC) in the binder fraction of concrete. Therefore, understanding the reactivity of fly ash in the hyperalkaline conditions prevalent in concrete is critical to predicting concrete's performance; including setting and strength gain. Herein, temporal measurements of the solution composition (using inductively coupled plasma‐optical emission spectrometry: ICP‐OES) are used to assess the aqueous dissolution rate of monophasic synthetic aluminosilicate glasses analogous to those present in technical fly ashes, under hyperalkaline conditions (10 ≤ pH ≤ 13) across a range of temperatures (25°C ≤ T≤45°C). The dissolution rate is shown to depend on the average number of topological constraints per atom within the glass network (n c , unitless), but this dependence weakens with increasing pH (>10). This is postulated to be on account of: (a) time‐dependent changes in the glass’ surface structure, that is, the number of topological constraints; and/or (b) a change in the dissolution mechanism (eg from network hydrolysis to transport control). The results indicate that the topological description of glass dissolution is most rigorously valid only at very short reaction times (ie at high undersaturations), especially under conditions of hyperalkalinity. These findings provide an improved basis to understand the underlying factors that affect the initial and ongoing reactivity of aluminosilicate glasses such as fly ash in changing chemical environments, for example, when such materials are utilized in cementitious composites.

Oey, Tandré↗

CsPbBr3 perovskite single crystals for X- and -radiation detectors

Methods were developed for the synthesis and growth of halide lead perovskites CsPbBr3, which can be used as detectors of optical, X-ray, and -radiation. The growth of single crystals was carried out by the Bridgman method in quartz ampoules using zone-refined starting material. The electro-physical properties of the inorganic perovskite lead cesium tribromide CsPbBr3 were studied. Two types of structures with Cr/CsPbBr3/Ni rectifying and Ni/CsPbBr3/Ni ohmic contacts were fabricated. The resistivity of (  7×109 Ohmcm), and the activation energy of the dark conductivity (E  0.8 eV) were determined. From the measurements of the optical transmission spectra, the CsPbBr3 energy gap at 300 K was found to be Еg = 2.27 eV. The temperature dependence of the forbidden gap (Eg(T) = 2.4 - 4*10-4 T, eV) was also determined. A significant increase in photosensitivity for the Cr/CsPbBr3/Ni structure was observed at elevated temperatures. The Cr/CsPbBr3/Ni structures were shown to be sensitive to -radiation. The FWHM of the energy resolution for 241Am source was measured to be 15.8 keV.

Sklyarchuk, V.↗

Ionization chamber gradient effects in nonstandard beam configurations

Purpose: For the purpose of nonstandard beam reference dosimetry, the current concept of reporting absorbed dose at a point in water located at a representative position in the chamber volume is investigated in detail. As new nonstandard beam reference dosimetry protocols are under development, an evaluation of the role played by the definition of point of measurement could lead to conceptual improvements prior to establishing measurement procedures. Methods: The present study uses the current definition of reporting absorbed dose to calculate ionization chamber perturbation factors for two cylindrical chamber models (Exradin A12 and A14) using the Monte Carlo method. The EGSnrc based user-code EGS lowbar chamber is used to calculate chamber dose responses of 14 IMRT beams chosen to cause considerable dose gradients over the chamber volume as previously used by Bouchard and Seuntjens [''Ionization chamber-based reference dosimetry of intensity modulated radiation beams,'' Med. Phys. 31(9), 2454-5465 (2004)]. Results: The study shows conclusively the relative importance of each physical effect involved in the nonstandard beam correction factors of 14 IMRT beams. Of all correction factors involved in the dosimetry of the beams studied, the gradient perturbation correction factor has the highest magnitude, on average, 11% higher compared to reference conditions for the Exradin A12 chamber and about 5% higher for the Extradin A14 chamber. Other perturbation correction factors (i.e., P{sub wall}, P{sub stem}, and P{sub cel}) are, on average, less than 0.8% different from reference conditions for the chambers and beams studied. The current approach of reporting measured absorbed dose at a point in water coinciding with the location of the centroid of the chamber is the main factor responsible for large correction factors in nonstandard beam deliveries (e.g., intensity modulated radiation therapy) reported in literature. Conclusions: To reduce or eliminate the magnitude of perturbation correction factors in nonstandard beam reference dosimetry, two possible ways to report absorbed dose are suggested: (1) Reporting average dose to the sensitive volume of the chamber filled with water, combined with removing the reference field implicit gradient effect when measuring output factors, and (2) reporting average dose to the chamber itself during output factor verifications. The first option could be adopted if clinical beam correction factors are negligible. The second option could simplify quality assurance procedures when correction factors are not negligible and have to be calculated using Monte Carlo simulations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to a small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more accurate than previously used values. For small ionization chambers with central electrodes composed of high-Z materials, the effect of the central electrode is much larger than that for the aluminum electrodes in Farmer chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} for several small detectors and for two linear accelerators using Monte Carlo simulations

Purpose: The scope of this study was to determine a complete set of correction factors for several detectors in static small photon fields for two linear accelerators (linacs) and for several detectors. Methods: Measurements for Monte Carlo (MC) commissioning were performed for two linacs, Siemens Primus and Elekta Synergy. After having determined the source parameters that best fit the measurements of field specific output factors, profiles, and tissue-phantom ratio, the generalized version of the classical beam quality correction factor for static small fields, k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were determined for several types of detectors by using the egs{sub c}hamber Monte Carlo user code which can accurately reproduce the geometry and the material composition of the detector. The influence of many parameters (energy and radial FWHM of the electron beam source, field dimensions, type of accelerator) on the value of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} was evaluated. Moreover, a MC analysis of the parameters that influence the change of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} as a function of field dimension was performed. A detailed analysis of uncertainties related to the measurements of the field specific output factor and to the Monte Carlo calculation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} was done. Results: The simulations demonstrated that the correction factor k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} can be considered independent from the quality beam factor Q in the range 0.68 {+-} 0.01 for all the detectors analyzed. The k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} of PTW 60012 and EDGE diodes can be assumed dependent only on the field size, for fields down to 0.5 x 0.5 cm{sup 2}. The microLion, and the microchambers, instead, must be used with some caution because they exhibit a slight dependence on the radial FWHM of the electron source, and therefore, a correction factor only dependent on field size can be used for fields {>=}0.75 x 0.75 and {>=}1.0 x 1.0 cm{sup 2}, respectively. The analysis of uncertainties gave an estimate of uncertainty for the 0.5 x 0.5 cm{sup 2} field of about 0.7% (1{sigma}) for k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} factor and of about 1.0% (1{sigma}) for the field output factor, {Omega}{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, of diodes, microchambers, and microLion. Conclusions: Stereotactic diodes with the appropriate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} are recommended for determining {Omega}{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} of small photon beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes

Purpose: GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. Methods: Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., {sup 177}Lu, {sup 90}Y, and {sup 32}P, and (c) gamma emitting isotopes, e.g., {sup 111}In, {sup 131}I, {sup 125}I, and {sup 99m}Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. Results: GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for {sup 67}Ga, {sup 68}Ga, {sup 90}Y, {sup 99m}Tc, {sup 111}In, {sup 123}I, {sup 124}I, {sup 125}I, {sup 131}I, {sup 153}Sm, {sup 177}Lu {sup 186}Re, and {sup 188}Re generated in water, bone, and lung. Conclusions: In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-E-17A-11: In-Phantom Detector Response in a Kilovoltage X-Ray Beam

Purpose: To investigate changes in detector response in a kilovoltage x-ray beam as a function of depth in phantom. Methods: Detector response in a 120kVp x-ray beam as a function of depth in a PMMA phantom was determined for a reference class Exradin A12 ionization chamber, an Exradin A1SL ionization chamber, TLD-100 and EBT3 radiochromic film and normalized to a depth of 1cm. The output of each detector was referenced to the A12 ionization chamber reading to assess changes in detector response as a function of depth. The BEAMnrc, DOSxyz, and egs-chamber user codes of the EGSnrc Monte Carlo code were used to calculate the dose delivered to the detectors from an x-ray source with similar beam quality to the one used in the measurements. Results: Changes in detector response relative to the A12 ionization chamber of 2%, 7%, and 14% for the A1SL, TLDs, and film, respectively, were observed with the larger changes in response occurring at larger depths. The Monte Carlo calculated changes in dose response showed less deviation, with the largest difference being within 2%. Conclusion: The Monte Carlo simulations show that doses delivered to the different detectors are quite similar, while measurements show that the detector output varies drastically. This indicates that the detector output per unit dose is changing with depth, most likely due to changes in the photon spectrum that occur because of scatter and attenuation of the primary beam. Because detector calibration is often performed at a single point in the kilovoltage energy range, the change in detector response needs to be considered when the measurement conditions differ from those of the calibration. This is of particular concern in computed tomography dose measurement, where calibrations are performed at shallow depths or in air, and measurements are made at deeper locations.

07 ISOTOPE AND RADIATION SOURCES↗

TU-F-BRE-03: Application of a Novel Mass-Density Compensation Optimization Method to Improve the Response of a Liquid-Filled Ionization Chamber in Nonstandard Fields

Purpose: To improve the response of the microLion detector (PTW 31018) in small field conditions by optimizing the density of the detector's non-sensitive components using a novel method based on the detector's dose response function. Methods: The central values h(0,0) of the perturbation functions for the microLion detector and a volume of water equivalent to its sensitive volume were calculated using the Monte Carlo user code egs-chamber by scoring the dose absorbed by a 6 MV photon pencil beam incident on their centroids. Values of h(0,0) were plotted as a function of the density of the microLion's graphite electrode with the detector placed in the axial orientation. The optimized density was found by finding the minimal value of h(0,0). Results: A density of 1.37 g/cm3 was found to minimize the perturbation function of the microLion detector. The modified microLion's response was then evaluated in small square fields with sides in the range of 5 – 40 mm and found to be consistent with highly watere-quivalent detectors such as a scintillating detector (Exradin W1) and a generic alanine detector in both axial and radial orientations. Conclusion: This work illustrates a novel method which can used to optimize the design of radiation detectors in small fields. This method should also work with other optimization parameters (e.g. thickness of electrode). Density-compensated detectors have the potential to eliminate the need to evaluate nonstandard field correction factors as described by the IAEA-AAPM formalism (Alfonso et al.) and simplify future dosimetry protocols for SRS/SBRT modalities. Finally, we also expect an improvement in the response of density-compensated detectors for composite IMRT fields.

07 ISOTOPE AND RADIATION SOURCES↗

WE-D-17A-04: Magnetically Focused Proton Irradiation of Small Volume Targets

Purpose: To explore the advantages of magnetic focusing for small volume proton irradiations and the potential clinical benefits for radiosurgery targets. The primary goal is to create narrow elongated proton beams of elliptical cross section with superior dose delivery characteristics compared to current delivery modalities (eg, collimated beams). In addition, more general beam shapes are also under investigation. Methods: Two prototype magnets consisting of 24 segments of samarium-cobalt (Sm2Co17) permanent magnetic material adhered into hollow cylinders were manufactured for testing. A single focusing magnet was placed on a positioning track on our Gantry 1 treatment table and 15 mm diameter proton beams with energies and modulation relevant to clinical radiosurgery applications (127 to 186 MeV, and 0 to 30 mm modulation) were delivered to a terminal water tank. Beam dose distributions were measured using a PTW diode detector and Gafchromic EBT2 film. Longitudinal and transverse dose profiles were analyzed and compared to data from Monte Carlo simulations analogous to the experimental setup. Results: The narrow elongated focused beam spots showed high elliptical symmetry indicating high magnet quality. In addition, when compared to unfocused beams, peak-to-entrance depth dose ratios were 11 to 14% larger (depending on presence or extent of modulation), and minor axis penumbras were 11 to 20% smaller (again depending on modulation) for focused beams. These results suggest that the use of rare earth magnet assemblies is practical and could improve dose-sparing of normal tissue and organs at risk while delivering enhanced dose to small proton radiosurgery targets. Conclusion: Quadrapole rare earth magnetic assemblies are a promising and inexpensive method to counteract particle out scatter that tends to degrade the peak to entrance performance of small field proton beams. Knowledge gained from current experiments will inform the design of a prototype treatment nozzle that incorporates similar focusing magnets. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-06: Challenges in the Dosimetry of Flattening Filter Free Beams

Purpose: In current dosimetry protocols [AAPM TG51, IAEA TRS-389] the beam quality correction factor kQ and the water-to-air restricted mass collision stopping-power ratio SPR are related to beam quality specifiers %dd(10){sub x} respectively TPR{sub 20,10} Determining kQ and SPR using these regular beam quality specifiers for conventional accelerators (WFF) and flattening filter free accelerators (FFF) similarly could lead to systemic bias.The influence of the flattening filter on the relationship between various beam quality specifiers and SPR respectively k{sub Q} was studied using Monte Carlo simulations with realistic beam sources. Methods: All Monte Carlo simulations were performed using the BEAMnrc/EGSnrc code system. Radiation transport through nine linear accelerator heads modeled according to technical drawings given by the manufactures and a {sup 60} Co therapy source was simulated with BEAMnrc and then used as a radiation source for further simulations. FFF beam sources were implemented by removing the fattening filter from the WFF model. SPR was calculated applying the user code SPRRZnrc. The mean photon energy below the accelerator head and the mean energies of photons and electrons at the measuring point within the water phantom were calculated using FLURZnrc. Dose calculations within a small water voxel and the thimble ionization chamber PTW-31010 in a water depth of 10 cm were made using the egs-chamber code. Results: SPR and k{sub Q} as a function of fluence spectra based beam quality specifiers as well as conventional beam quality specifiers differ systematically between FFF and WFF beams. According to the results the specifier %dd(10){sub x} revealed the smallest deviation (max. 0.4%) between FFF and WFF beams. Conclusion: The results show that %dd(10){sub x} is an acceptable beam quality specifier for FFF beams. Nevertheless the results confirm the expected bias between FFF and WFF beams which must by further investigated.

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 14: Improving Tissue Segmentation for Monte Carlo Dose Calculation using DECT

Purpose: To improve Monte Carlo dose calculation accuracy through a new tissue segmentation technique with dual energy CT (DECT). Methods: Electron density (ED) and effective atomic number (EAN) can be extracted directly from DECT data with a stoichiometric calibration method. Images are acquired with Monte Carlo CT projections using the user code egs-cbct and reconstructed using an FDK backprojection algorithm. Calibration is performed using projections of a numerical RMI phantom. A weighted parameter algorithm then uses both EAN and ED to assign materials to voxels from DECT simulated images. This new method is compared to a standard tissue characterization from single energy CT (SECT) data using a segmented calibrated Hounsfield unit (HU) to ED curve. Both methods are compared to the reference numerical head phantom. Monte Carlo simulations on uniform phantoms of different tissues using dosxyz-nrc show discrepancies in depth-dose distributions. Results: Both SECT and DECT segmentation methods show similar performance assigning soft tissues. Performance is however improved with DECT in regions with higher density, such as bones, where it assigns materials correctly 8% more often than segmentation with SECT, considering the same set of tissues and simulated clinical CT images, i.e. including noise and reconstruction artifacts. Furthermore, Monte Carlo results indicate that kV photon beam depth-dose distributions can double between two tissues of density higher than muscle. Conclusions: A direct acquisition of ED and the added information of EAN with DECT data improves tissue segmentation and increases the accuracy of Monte Carlo dose calculation in kV photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes

Purpose: This study explores the possibility of using lead to cover part of the radiation therapy facility maze walls in order to absorb low energy photons and reduce the total dose at the maze entrance of radiation therapy rooms. Methods: Experiments and Monte Carlo simulations were utilized to establish the possibility of using high-Z materials to cover the concrete walls of the maze in order to reduce the dose of the scattered photons at the maze entrance. The dose of the backscattered photons from a concrete wall was measured for various scattering angles. The dose was also calculated by the FLUKA and EGSnrc Monte Carlo codes. The FLUKA code was also used to simulate an existing radiotherapy room to study the effect of multiple scattering when adding lead to cover the concrete walls of the maze. Monoenergetic photons were used to represent the main components of the x ray spectrum up to 10 MV. Results: It was observed that when the concrete wall was covered with just 2 mm of lead, the measured dose rate at all backscattering angles was reduced by 20% for photons of energy comparable to Co-60 emissions and 70% for Cs-137 emissions. The simulations with FLUKA and EGS showed that the reduction in the dose was potentially even higher when lead was added. One explanation for the reduction is the increased absorption of backscattered photons due to the photoelectric interaction in lead. The results also showed that adding 2 mm lead to the concrete walls and floor of the maze reduced the dose at the maze entrance by up to 90%. Conclusions: This novel proposal of covering part or the entire maze walls with a few millimeters of lead would have a direct implication for the design of radiation therapy facilities and would assist in upgrading the design of some mazes, especially those in facilities with limited space where the maze length cannot be extended to sufficiently reduce the dose.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-304-06: Determination of Intermediate Correction Factors for Three Dosimeters in Small Composite Photon Fields Used in Robotic Radiosurgery

Purpose: To calculate using Monte-Carlo the intermediate and total correction factors (CFs) for two microchambers and a plastic scintillator for composite fields delivered by the CyberKnife system. Methods: A linac model was created in BEAMnrc by matching percentage depth dose (PDD) curves and output factors (OFs) measured using an A16 microchamber with Monte Carlo calculations performed in egs-chamber to explicitly model detector response. Intermediate CFs were determined for the A16 and A26 microchambers and the W1 plastic scintillator in fourteen different composite fields inside a solid water phantom. Seven of these fields used a 5 mm diameter collimator; the remaining fields employed a 7.5 mm collimator but were otherwise identical to the first seven. Intermediate CFs are reported relative to the respective CF for a 60 mm collimator (800 mm source to detector distance and 100 mm depth in water). Results: For microchambers in composite fields, the intermediate CFs that account for detector density and volume were the largest contributors to total CFs. The total CFs for the A26 were larger than those for the A16, especially for the 5 mm cone (1.227±0.003 to 1.144±0.004 versus 1.142±0.003 to 1.099±0.004), due to the A26’s larger active volume (0.015 cc) relative to the A16 (0.007 cc), despite the A26 using similar wall and electrode material. The W1 total and intermediate CFs are closer to unity, due to its smaller active volume and near water-equivalent composition, however, 3–4% detector volume corrections are required for 5 mm collimator fields. In fields using the 7.5 mm collimator, the correction is nearly eliminated for the W1 except for a non-isocentric field. Conclusion: Large and variable CFs are required for microchambers in small composite fields primarily due to density and volume effects. Corrections are reduced but not eliminated for a plastic scintillator in the same fields.

60 APPLIED LIFE SCIENCES↗

SU-E-P-19: A National Collaborative Academic Medical Physics Network: Structure, Activity and Outcomes

Purpose: A national Australian inter-university medical physics (MP) group was formed in 2011/12, supported by Department of Health Better Access to Radiation Oncology BARO) seed funding. Core membership includes the six universities providing postgraduate MP courses. Objectives include increasing capacity, development and efficiency of national academic MP structures/systems and hence supporting education, clinical training and research, for the MP workforce support. Although the BARO scheme focuses on Radiation Oncology, the group has wider MP interests. Methods: Two further BARO seed grants were achieved: 1) for networked academic activities, including shared-resource teaching, eg using virtual reality systems; MP outreach to schools and undergraduates; developing web-based student and registrar education/resources, etc.; and 2) for conjoint ‘translational research’ posts between universities and partner hospitals, to clinically progress advanced RT technologies and to support students and registrars. Each university received 0.5 FTE post from each grant over 2 years (total: $1.75M) and leveraged local additional partner funds. Results: Total funding: $4–5M. Overall there have been 35 (mainly overseas) postholders bringing specific expertise, beginning in early 2013. Periods in Australia have been from 0.25–2 years (median=1). As well as the education activities, research projects include lung/spine SBRT, 4D RT, FFF beams, technology assessment, complex treatment planning, imaging for radiation oncology, DIR, adaptive breast, datamining, radiomics,etc. Observed positive impacts include: increased interest in MP courses, training support, translational research infrastructure and/or clinical practice in the hospitals involved, plus increased collaboration and effectiveness between the universities. Posts are continuing beyond grant end using leveraged funds, providing the basis for sustainability of some posts. Conclusion: The BARO-funded projects have cost-effectively produced a range of positive impacts on training, research and practice in hospitals and between universities. The evaluation of the specific post roles and activities, and their outcomes, has produced focused recommendations on continuation and sustainability. Funding was from the Australian federal Department of Health; leveraged funding was from partner universities and hospitals.

60 APPLIED LIFE SCIENCES↗

SU-E-T-35: A General Fill Factor Definition Serving to Characterise the MLC Misalignment Detection Capabilities of Two-Dimensional Detector Arrays

Purpose: To present a general definition of the fill factor realistically characterizing the “field coverage”, i.e. the MLC misalignment detection capabilities of a detector array. Methods: According to Gago-Arias et al.{sup 1} the fill factor of a 2D array is defined as the ratio of the area enclosed by the FWHM of the fluence response function KM(x) of a single detector and its cell area defined by the detector spacing. More generally - accounting also for the possible overlap between FWHM’s of neighboured detectors - the fill factor is here defined as that fraction of the sum of the detector cell areas in which a defined MLC misalignment is detectable when the induced percentage signal changes exceed a detection threshold d. Ideally the generalized fill factor may reach 100 %. With user code EGS-chamber and a 2 MeV photon slit beam 0.25 mm wide, both types of the fill factor were calculated for an array with total cell area 100 cm{sup 2} for chamber widths 1–9 mm, using =1mm, d=5%. Results: For single chamber width 5 mm, fill factors were 0.49 (FWHM) and 0.61 (generalized). For chamber width 2 mm the FWHM fill factor was 0.13 whereas the generalized fill factor was 0.32. For chamber widths above 7 mm, the FWHM fill factor exceeds unity, and the general fill factor is exactly 1.00. Conclusions: An updated fill factor definition is introduced which, as a generalization of the FWHM-based definition, more closely estimates the performance of small array chambers and gives a realistic value in the case of overlapping sensitive areas of neighboured chambers. References:{sup 1}A. Gago-Arias, L. Brualla-Gonzalez, D.M. Gonzalez-Castano, F. Gomez, M.S. Garcia, V.L. Vega, J.M. Sueiro, J. Pardo-Montero, “Evaluation of chamber response function influence on IMRT verification using 2D commercial detector arrays,” Phys. Med. Biol. 57, 2005–2020 (2012)

60 APPLIED LIFE SCIENCES↗