Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

IUE observations of circumstellar emission from the late type variable R Aquarii /M7 + pec/

IUE observations of R Aquarii (M7 + pec) have been obtained in low dispersion in order to study its circumstellar emission. Strong permitted, semiforbidden, and forbidden emission lines are identified that are superposed on a bright ultraviolet continuum. From the analysis it is deduced that the strong emission-line spectrum that involves semiforbidden C III, C IV, semiforbidden Si III, forbidden O II, and forbidden O III probably arises from a dense compact nebula the size of which is comparable to the binary system of which R Aqr is the primary star. Low-excitation emission lines of Fe II, Mg II, O I, and Si II suggest the presence of a warm chromosphere (T less than about 10,000 K) in the primary M7 late type giant. The secondary is identified as a white dwarf, comparable to or somewhat brighter than the sun, since such a star can produce enough ionizing photons to excite the continuum and emission-line spectrum and yet be sufficiently faint to escape detection by direct observation. The UV continuum observed is attributed to Balmer recombination and not to blackbody emission from the hot companion. The general spectral properties of R Aqr between 1200 A and 3200 A are discussed in the context of the model for the circumstellar nebula, the companion, and the mass-loss rate of the primary star.

Michalitsianos, A. G.↗

IUE observations of circumstellar emission from the late-type variable R AQR (M6 + pec)

The IUE observations of R Aqr (M7 + pec) obtained in low dispersion are discussed with particular reference to circumstellar emission. Strong permitted, semiforbidden, and forbidden emission lines are seen, superimposed on a bright ultraviolet continuum. It is deduced that the strong emission line spectrum that involves C III, C IV, Si III, (0 II) and (0 III) probably arises from a dense compact nebula the size of which is comparable to the orbital radius of the binary system of which R Aqr is the primary star. The low excitation emission lines of Fe II, Mg II, 0 I, and Si II probably a white dwarf, comparable to or somewhat brighter than the Sun, since such a star can produce enough ionizing photons to excite the continuum and emission line spectrum and yet be sufficiently faint as to escape detection by direct observation. The UV continuum is attributed to Balmer recombination from the dense nebula and not to blackbody emission from the hot companion.

Hobbs, R. W.↗

Bandwidth limitations on noiseless optical channel capacity

The channel capacity of an optical communications link utilizing direct photon detection can be substantially larger than the heterodyne detection quantum limit. In the limit of a noiseless channel the capacity per received photon can even be infinite. In most communications systems the real constraint is to deliver a certain throughput capacity measured in nats/second. The current investigation has the objective to show that due to physical limitations on the minimum time resolution which can be achieved, and for any given throughput capacity in nats/second, there exists an optimum PPM word size which maximizes the 'power efficiency capacity' expressed in nats/photon. Such an optimization will allow the system-designer to minimize the amount of power needed to achieve the desired throughput without violating his bandwidth constraint.

Butman, S. A.↗

Broadband optical radiation detector

A method and apparatus for detecting optical radiation by optically monitoring temperature changes in a microvolume caused by absorption of the optical radiation to be detected is described. More specifically, a thermal lens forming material is provided which has first and second opposite, substantially parallel surfaces. A reflective coating is formed on the first surface, and a radiation absorbing coating is formed on the reflective coating. Chopped, incoming optical radiation to be detected is directed to irradiate a small portion of the radiation absorbing coating. Heat generated in this small area is conducted to the lens forming material through the reflective coating, thereby raising the temperature of a small portion of the lens forming material and causing a thermal lens to be formed therein.

Gupta, A.↗

Optical measurement of the velocity of dielectric surface arcs

Surface flashover arc discharge velocities on electron-beam-charged polymer sheets have been measured directly by detecting the light emitted at two points along a straight arc and measuring the time interval between light pulses. For Mylar, the average velocity is 1.2 x 10 to the 6th m/s, and for Teflon the average velocity is approximately 7.3 x 10 to the 5th m/s independent of sheet thickness. These velocities are about two to four times higher than previous measurements. The techniques employed to produce single, straight surface arcs are described.

Balmain, K. G.↗

A two-photon laser-induced fluorescence field instrument for ground-based and airborne measurements of atmospheric NO

This paper reports on a new two-photon laser-induced fluorescence (TP-LIF) sensor capable of making routine measurements at the few parts per trillion volume level. This direct spectroscopic detection method has been demonstrated to be a reliable instrument while performing both on the ground and in the air. As currently designed it is unique in being 'signal' rather than 'signal-to-noise' limited. The latter characteristic enables the TP-LIF sensor to make atmospheric measurements of NO under environmental conditions that might normally be considered unsuitable for a laser technique. These include clouds, rain, and, in general, high-atmospheric-aerosol loading conditions. Of special interest is the insensitivity of the TP-LIF NO instrument to changes in pressure while operating in the troposphere. This characteristic has enabled this sensor to be used to record real-time altitude profiles of NO. Future improvements should make possible two measurement opportunities: (1) NO flux measurements via the airborne eddy-correlation method and (2) nitrogen isotopic distribution measurements (e.g., (N-15)(0-16) versus (N-14)(0-16) as a means of identifying specific NO(x) sources.

Bradshaw, J. D.↗

Infrared spectroscopy of the lower stratosphere with a balloon-borne cryogenic Fourier spectrometer

The IR limb emission of the lower stratosphere has been measured using a balloon-borne liquid nitrogen-cooled Michelson interferometer with liquid helium-cooled Si:Ga detectors. Portions of the thermal emission spectrum have been recorded between 650 and 2000/cm with an unapodized spectral resolution of 0.03/cm. This is the highest spectral resolution limb emission thus far obtained. A preliminary description is given of these data along with a discussion of the significant features. Species identified to date include CO2, O3, CFCl3, CF2Cl2, H2O, CH4, HNO3, N2O, NO2, and ClONO2. A tentative identification is made for NO, representing the first direct spectroscopic detection of NO in emission.

Kunde, Virgil G.↗

The polarization of escaping terrestrial continuum radiation

The polarization of an escaping terrestrial continuum radiation event that occurred on March 2, 1982, was determined using plasma wave measurements from the DE-1 spacecraft. The source of the radiation was determined to be located near the magnetic equator on the nightside of the earth at a radial distance of about 2.8-3.5 earth radii. Two meridional beams were detected, one directed north at an angle of about 20-30 deg with respect to the magnetic equator, and the other directed south at a comparable angle. Polarization measurements indicated that the radiation is right-hand polarized with respect to an outward directed E plane normal in the Northern Hemisphere and left-hand polarized in the Southern Hemisphere.

Gurnett, D. A.↗

Magma chambers

Recent observational and theoretical investigations of terrestrial magma chambers (MCs) are reviewed. Consideration is given to the evidence for MCs with active convection and crystal sorting, problems of direct MC detection, theoretical models of MC cooling, the rheology and dynamics of solidification fronts, crystal capture and differentiation, convection with solidification, MC wall flows, and MC roof melting. Diagrams, graphs, and a list of problems requiring further research are provided.

Marsh, Bruce D.↗

Symmetrical jet action in the R Aquarii binary system

Collimated mass flow in opposite directions is detected in the R Aqr binary-system jet by means of high-resolution long-slit spectroscopy of several optical emission lines. Also presented are images of the jet structure in the forbidden line of O III, which clearly show bipolar symmetry extending to distances of about 2750 AU on either side of the central Mira variable. The Mira light was greatly reduced by utilization of a vignetting disk on the window of the imaging CCD. This result confirms the recent report of morphological evidence for an R Aqr jet from the detection of bipolar radio continuum emission at 6 cm, and provides the necessary kinematical evidence to show that jet action is actually taking place.

Hollis, J. M.↗

X-ray study of superclusters

The Batuski-Burns list of candidate superclusters was searched for X-ray emission in the HEAO 1 A-2 data base. No significant flux in excess of integrated member cluster emission was detected in directions associated with estimated supercluster centroids; a 3 sigma upper limit to the mean individual excess flux is 5 x 10 to the -12th ergs/sq cm/s. Implications of this bound are discussed in terms of fainter member clusters, hot diffuse gas, and active and normal galaxies. Prospects of supercluster observations related to future X-ray missions are also outlined.

Persic, M.↗

Optical system design for a Lunar Optical Interferometer

The moon offers particular advantages for interferometry, including a vacuum environment, a large stable base on which to assemble multi-kilometer baselines, and a cold nighttime temperature to allow for passive cooling of optics for high IR sensitivity. A baseline design for a Lunar Optical Interferometer (LOI) which exploits these features is presented. The instrument operates in the visible to mid-IL region, and is designed for both astrometry and synthesis imaging. The design uses a Y-shaped array of 12 siderostats, with maximum arm lengths of about 1 km. The inner siderostats are monitored in three dimensions from a central laser metrology structure to allow for high precision astrometry. The outer siderostats, used primarily for synthesis imaging, exploit the availability of bright reference stars in order to determine the instrument geometry. The path delay function is partitioned into coarse and fine components, the former accomplished with switched banks of range mirrors monitored with an absolute laser metrology system, and the latter with a short cat's eye delay line. The back end of the instrument is modular, allowing for beam combiners for astrometry, visible and IR synthesis imaging, and direct planet detection. With 1 m apertures, the instrument will have a point-source imaging sensitivity of about 29 mag; with the laser metrology system, astrometry at the microarcsecond level will be possible.

Colavita, M. M.↗

Digital mammography, cancer screening: Factors important for image compression

The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers.

Clarke, Laurence P.↗

Assessment of velocity/trajectory measurement technologies during a particle capture event

Since the early 1960s, the means to measure the time of flight (TOF) of dust grain within a mechanical detection array has existed, first in the laboratory and then in space experiments. Laboratory hypervelocity dust particle accelerators have used electrostatic detection of charge on accelerated particles for TOF and particle mass detections. These laboratory studies have led to the development of ultra-thin-film sensors that have been used for TOF measurements in dust particle space experiments. The prototypes for such devices were ultra-thin-film capacitors that were used in the OGO series of satellites. The main goal of the experimental work to be described is the development of the capability to determine the velocity vector or trajectory of a dust grain traversing an integrated dust detection array. The results of these studies have shown that the capability of detecting the charge liberated by hypervelocity dust grains with diameters in the micrometer range can be detected. Based on these results, detection systems have been designed to provide a precise analysis of the physical and dynamic properties of micrometer and submicrometer dust grains, namely the design verification unit (DVU). Through unique combinations of in situ detection systems, direct measurements of particle surface charge, velocity, momentum, kinetic energy, and trajectory have been achieved. From these measurements, the remaining physical parameters of mass, size, and density can be determined.

Tanner, William G.↗

Program Instrumentation and Trace Analysis

Several attempts have been made recently to apply techniques such as model checking and theorem proving to the analysis of programs. This shall be seen as a current trend to analyze real software systems instead of just their designs. This includes our own effort to develop a model checker for Java, the Java PathFinder 1, one of the very first of its kind in 1998. However, model checking cannot handle very large programs without some kind of abstraction of the program. This paper describes a complementary scalable technique to handle such large programs. Our interest is turned on the observation part of the equation: How much information can be extracted about a program from observing a single execution trace? It is our intention to develop a technology that can be applied automatically and to large full-size applications, with minimal modification to the code. We present a tool, Java PathExplorer (JPaX), for exploring execution traces of Java programs. The tool prioritizes scalability for completeness, and is directed towards detecting errors in programs, not to prove correctness. One core element in JPaX is an instrumentation package that allows to instrument Java byte code files to log various events when executed. The instrumentation is driven by a user provided script that specifies what information to log. Examples of instructions that such a script can contain are: 'report name and arguments of all called methods defined in class C, together with a timestamp'; 'report all updates to all variables'; and 'report all acquisitions and releases of locks'. In more complex instructions one can specify that certain expressions should be evaluated and even that certain code should be executed under various conditions. The instrumentation package can hence be seen as implementing Aspect Oriented Programming for Java in the sense that one can add functionality to a Java program without explicitly changing the code of the original program, but one rather writes an aspect and compiles it into the original program using the instrumentation. Another core element of JPaX is an observation package that supports the analysis of the generated event stream. Two kinds of analysis are currently supported. In temporal analysis the execution trace is evaluated against formulae written in temporal logic. We have implemented a temporal logic evaluator on finite traces using the Maude rewriting system from SRI International, USA. Temporal logic is defined in Maude by giving its syntax as a signature and its semantics as rewrite equations. The resulting semantics is extremely efficient and can handle event streams of hundreds of millions events in few minutes. Furthermore, the implementation is very succinct. The second form of even stream analysis supported is error pattern analysis where an execution trace is analyzed using various error detection algorithms that can identify error-prone programming practices that may potentially lead to errors in some different executions. Two such algorithms focusing on concurrency errors have been implemented in JPaX, one for deadlocks and the other for data races. It is important to note, that a deadlock or data race potential does not need to occur in order for its potential to be detected with these algorithms. This is what makes them very scalable in practice. The data race algorithm implemented is the Eraser algorithm from Compaq, however adopted to Java. The tool is currently being applied to a code base for controlling a spacecraft by the developers of that software in order to evaluate its applicability.

Havelund, Klaus↗

Ultrasensitive Label-free Electronic Chip for DNA Analysis Using Carbon Nanotube Nanoelectrode Arrays

There is a strong need for faster, cheaper, and simpler methods for nucleic acid analysis in today s clinical tests. Nanotechnologies can potentially provide solutions to these requirements by integrating nanomaterials with biofunctionalities. Dramatic improvement in the sensitivity and multiplexing can be achieved through the high-degree miniaturization. Here, we present our study in the development of an ultrasensitive label-free electronic chip for DNA/RNA analysis based on carbon nanotube nanoelectrode arrays. A reliable nanoelectrode array based on vertically aligned multi-walled carbon nanotubes (MWNTs) embedded in a SiO2 matrix is fabricated using a bottom-up approach. Characteristic nanoelectrode behavior is observed with a low-density MWNT nanoelectrode array in measuring both the bulk and surface immobilized redox species. The open-end of MWNTs are found to present similar properties as graphite edge-plane electrodes, with a wide potential window, flexible chemical functionalities, and good biocompatibility. A BRCA1 related oligonucleotide probe with 18 bases is covalently functionalized at the open ends of the MWNTs and specifically hybridized with an oligonucleotide target as well as a PCR amplicon. The guanine bases in the target molecules are employed as the signal moieties for the electrochemical measurements. Ru(bpy)3(2+) mediator is used to further amplify the guanine oxidation signal. This technique has been employed for direct electrochemical detection of label-free PCR amplicon through specific hybridization with the BRCAl probe. The detection limit is estimated to be less than approximately 1000 DNA molecules, approaching the limit of the sensitivity by laser-based fluorescence techniques in DNA microarray. This system provides a general electronic platform for rapid molecular diagnostics in applications requiring ultrahigh sensitivity, high-degree of miniaturization, simple sample preparation, and low- cost operation.

Li, Jun↗

Multiple Epstein-Barr virus infections in healthy individuals

We employed a newly developed genotyping technique with direct representational detection of LMP-1 gene sequences to study the molecular epidemiology of Epstein-Barr virus (EBV) infection in healthy individuals. Infections with up to five different EBV genotypes were found in two of nine individuals studied. These results support the hypothesis that multiple EBV infections of healthy individuals are common. The implications for the development of an EBV vaccine are discussed.

Evaluation Studies↗

A low molecular weight artificial RNA of unique size with multiple probe target regions

Artificial RNAs (aRNAs) containing novel sequence segments embedded in a deletion mutant of Vibrio proteolyticus 5S rRNA have previously been shown to be expressed from a plasmid borne growth rate regulated promoter in E. coli. These aRNAs accumulate to high levels and their detection is a promising tool for studies in molecular microbial ecology and in environmental monitoring. Herein a new construct is described which illustrates the versatility of detection that is possible with aRNAs. This 3xPen aRNA construct carries a 72 nucleotide insert with three copies of a unique 17 base probe target sequence. This aRNA is 160 nucleotides in length and again accumulates to high levels in the E. coli cytoplasm without incorporating into ribosomes. The 3xPen aRNA illustrates two improvements in detection. First, by appropriate selection of insert size, we obtained an aRNA which provides a unique and hence, easily quantifiable peak, on a high resolution gel profile of low molecular weight RNAs. Second, the existence of multiple probe targets results in a nearly commensurate increase in signal when detection is by hybridization. These aRNAs are naturally amplified and carry sequence segments that are not found in known rRNA sequences. It thus may be possible to detect them directly. An experimental step involving RT-PCR or PCR amplification of the gene could therefore be avoided.

Non-NASA Center↗