Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Possible Explanation of the Geograv Detector Signal during the Explosion of SN 1987A in Modified Gravity Models

A change in the law of attraction in some regimes is predicted in the modified gravity models being actively developed at present. The set of up-to-date observational data leaves a wide range of admissible parameters for the theory. In this paper, we consider the possibility that the signal recorded by the Geograv resonant gravitational-wave detector in 1987 during the explosion of SN 1987A was produced by an abrupt change in the metric during the passage of a powerful neutrino flux through the detector. Such an impact on the detector is possible, in particular, in extended scalar–tensor theories in which the local matter density gradient affects the gravitational force. The first short neutrino pulse emitted at the initial stage of stellar core collapse before the onset of neutrino opacity could exert a major influence on the detector, because it could produce the detector response at the first resonance frequency. In contrast, the influence of the subsequent broad pulse (with a duration of several seconds) in the resonant detector is exponentially suppressed, despite the fact that the second pulse carries an order-of-magnitude more neutrino energy, and it could generate a signal in the LSD neutrino detector. This explains the time delay of 1.4 s between the Geograv and LSD signals. The consequences of this effect of modified gravity for future LIGO/Virgo observations are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas gain stabilisation in the ATLAS TRT detector

The ATLAS (one of two general purpose detectors at the LHC) Transition Radiation Tracker (TRT) is the outermost of the three tracking subsystems of the ATLAS Inner Detector. It is a large straw-based detector and contains about 350,000 electronics channels. The performance of the TRT as tracking and particularly particle identification detector strongly depends on stability of the operation parameters with most important parameter being the gas gain which must be kept constant across the detector volume. The gas gain in the straws can vary significantly with atmospheric pressure, temperature, and gas mixture composition changes. This paper presents a concept of the gas gain stabilisation in the TRT and describes in detail the Gas Gain Stabilisation System (GGSS) integrated into the Detector Control System (DCS). Operation stability of the GGSS during Run-1 is demonstrated.

47 OTHER INSTRUMENTATION↗

Considerations about future hard x-ray area detectors

X-ray sources continue to advance in both intensity and temporal domains, thereby opening new ways to analyze the structure and properties of matter, provided that the resultant x-ray images can be efficiently and quantitatively recorded. In this perspective we focus on specific limitations of pixel area x-ray detectors. Although pixel area x-ray detectors have also advanced in recent years, many experiments are still detector limited. Specifically, there is need for detectors that can acquire successive images at GHz rates; detectors that can accurately measure both single photon and millions of photons per pixel in the same image at frame rates of hundreds of kHz; and detectors that efficiently capture images of very hard x-rays (20 keV to several hundred keV). The data volumes and data rates of state-of-the-art detection exceeds most practical data storage options and readout bandwidths, thereby necessitating on-line processing of data prior to, or in lieu of full frame readouts.

36 MATERIALS SCIENCE↗

Reconstructing the direction of reactor antineutrinos via electron scattering in Gd-doped water Cherenkov detectors

The potential of elastic antineutrino-electron scattering (ν¯ e + e – → ν¯ e + e – ) in a Gd-doped water Cherenkov detector to determine the direction of a nuclear reactor antineutrino flux was investigated using the recently proposed WATCHMAN antineutrino experiment as a baseline model. The expected scattering rate was determined assuming a 13 km standoff from a 3.758 GWt light water nuclear reactor. Background was estimated via independent simulations and by appropriately scaling published measurements from similar detectors. Many potential backgrounds were considered, including solar neutrinos, misidentified reactor-based inverse beta decay interactions, cosmogenic radionuclide and water-borne radon decays, and gamma rays from the photomultiplier tubes, detector walls, and surrounding rock. The detector response was modeled using a GEANT4-based simulation package. The results indicate that with the use of low radioactivity PMTs and sufficient fiducialization, water-borne radon and cosmogenic radionuclides pose the largest threats to sensitivity. The directional sensitivity was then analyzed as a function of radon contamination, detector depth, and detector size. Lastly, the results provide a list of theoretical conditions that, if satisfied in practice, would enable nuclear reactor antineutrino directionality in a Gd-doped water Cherenkov detector approximately 10 km from a large power reactor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3 ) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235 U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A suite of neutron time-of-flight detectors to measure hot-spot motion in direct-drive inertial confinement fusion experiments on OMEGA

A suite of six neutron time of flight detectors capable of measuring the primary DT neutron energy spectrum has recently been completed on the OMEGA Laser System. The detectors are positioned along multiple quasi-orthogonal lines of sight (LOS’s) in either a stand-alone, collinear, or antipodal configuration. The collinear detector configuration enables one to measure the neutron velocity along the detector LOS independent of the neutron-production history, while the antipodal detector configuration enables one to directly measure of the hot-spot velocity along the detector axis and Gamow velocity shift due to the plasma ion temperature. Using these six measurements of the primary DT neutron energy spectrum, the neutron-averaged hot-spot velocity and Gamow velocity shift of DT fusion neutrons have been measured in cryogenic experiments on OMEGA for the first time. Finally, the detector suite is operable between DT neutron yields of 1 × 10 13 to 2 × 10 14 with an uncertainty of ~14 km/s in the neutron-averaged hot-spot velocity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent charge barrier height of amorphous germanium contact detector

The exploration of germanium (Ge) detectors with amorphous Ge (a-Ge) contacts has drawn attention to the searches for rare-event physics such as dark matter and neutrinoless double-beta decay. The charge barrier height (CBH) of the a-Ge contacts deposited on the detector surface is crucial to suppress the leakage current of the detector in order to achieve a low-energy detection threshold and high-energy resolution. The temperature-dependent CBH of a-Ge contacts for three Ge detectors is analyzed to study the bulk leakage current (BLC) characteristics. The detectors were fabricated at the University of South Dakota using homegrown crystals. The CBH is determined from the BLC when the detectors are operated in the reverse bias mode with a guard-ring structure, which separates the BLC from the surface leakage current (SLC). Here the results show that CBH is temperature dependent. The direct relation of the CBH variation to temperature is related to the barrier inhomogeneities created on the interface of a-Ge and crystalline Ge. The inhomogeneities that occur at the interface were analyzed using the Gaussian distribution model for three detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Interpolation of computed gamma-ray detector response functions

Gamma-ray spectra measured by traditional detectors contain features that result from a combination of the effects of detector materials/geometry, the incident gamma-ray energy, and the angle of entry. The features, such as the full-energy photopeak, Compton continuum, annihilation peak, and escape peaks, are governed by simple relationships depending on incident energy and have been known for a long time. Monte Carlo computer simulations of gamma rays interacting with a detector will show these features, and with a resolution function applied, the results should look similar to real measurements. The traditional approach to creating a detector response function requires many separate simulations of monoenergetic gamma rays striking the detector. This paper presents a new approach to developing computed detector response functions. The new approach involves a much smaller number of monoenergetic gamma-ray simulations and uses interpolation to quickly generate the responses of gamma rays that were not simulated. During the interpolation process, the underlying physics equations are used to accurately compute the response of a given energy gamma ray from the small set of simulations. Such work enables accelerated generation of synthetic radiation detector data.

Detector response↗

A micron resolution optical scanner for characterization of silicon detectors

The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New approach to calculate the true-coincidence effect of HpGe detector

The corrections for true-coincidence effects in HpGe detector are important, especially at low source-to-detector distances. This work established an approach to calculate the true-coincidence effects experimentally for HpGe detectors of type Canberra GC3018 and Ortec GEM25-76-XLB-C, which are in operation at neutron activation analysis lab in Malaysian Nuclear Agency (NM). The correction for true-coincidence effects was performed close to detector at distances 2 and 5 cm using {sup 57}Co, {sup 60}Co, {sup 133}Ba and {sup 137}Cs as standard point sources. The correction factors were ranged between 0.93-1.10 at 2 cm and 0.97-1.00 at 5 cm for Canberra HpGe detector; whereas for Ortec HpGe detector ranged between 0.92-1.13 and 0.95-100 at 2 and 5 cm respectively. The change in efficiency calibration curve of the detector at 2 and 5 cm after correction was found to be less than 1%. Moreover, the polynomial parameters functions were simulated through a computer program, MATLAB in order to find an accurate fit to the experimental data points.

07 ISOTOPE AND RADIATION SOURCES↗

Hexagonal boron nitride neutron detectors with high detection efficiencies

Here, neutron detectors fabricated from 10B enriched hexagonal boron nitride (h- 10 BN or h-BN) epilayers have demonstrated the highest thermal neutron detection efficiency among solid-state neutron detectors to date at about 53%. In this work, photoconductive-like vertical detectors with a detection area of 1 × 1 mm 2 were fabricated from 50 μm thick free-standing h-BN epilayers using Ni/Au and Ti/Al bilayers as ohmic contacts. Leakage currents, mobility-lifetime (μτ) products under UV photoexcitation, and neutron detection efficiencies have been measured for a total of 16 different device configurations. The results have unambiguously identified that detectors incorporating the Ni/Au bilayer on both surfaces as ohmic contacts and using the negatively biased top surface for neutron irradiation are the most desired device configurations. It was noted that high growth temperatures of h- 10 BN epilayers on sapphire substrates tend to yield a higher concentration of oxygen impurities near the bottom surface, leading to a better device performance by the chosen top surface for irradiation than by the bottom. Preferential scattering of oxygen donors tends to reduce the mobility of holes more than that of electrons, making the biasing scheme with the ability of rapidly extracting holes at the irradiated surface while leaving the electrons to travel a large average distance inside the detector at a preferred choice. When measured against a calibrated 6 LiF filled micro-structured semiconductor neutron detector, it was shown that the optimized configuration has pushed the detection efficiency of h-BN neutron detectors to 58%. These detailed studies also provided a better understanding of growth-mediated impurities in h-BN epilayers and their effects on the charge collection and neutron detection efficiencies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of large-volume Frisch grid detector fabricated from as-grown CdZnTeSe

CdZnTe (CZT) has been under continuous development as a room-temperature radiation detector for the past 2-3 decades. Due to its intrinsic defects, such as a high concentration sub-grain boundary network, it has been very challenging to consistently produce high-quality CZT detectors with high yield, particularly for detector volumes exceeding a few cm 3 . In this paper, we report characterization of a relatively large-volume Frisch-grid detector (dimensions: 11x10.8x19.4 mm 3 ) fabricated from a new material Cd 0.9 Zn 0.1 Te 0.985 Se 0.015 . Furthermore, the detector was fabricated from an as-grown ingot with a two-inch diameter grown by the Traveling Heater Method (THM). The detector sample was evaluated by infrared (IR) transmission microscopy to study the presence of Te inclusions. X-ray topography using a synchrotron light source was deployed to measure the presence of sub-grain boundaries and their networks. Finally, the detector performance was measured for an optimized Frisch-grid length to extract the best energy resolution at room temperature.

36 MATERIALS SCIENCE↗

Study of perovskite CsPbBr 3 detector polarization and its mitigation with ultrahigh x-ray flux

High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, for this work, we studied the polarization of perovskite CsPbBr 3 semiconductor detectors using ultrahigh flux synchrotron x rays (10 6 –10 12 photons s –1 mm –2 at 58.61 keV). The CsPbBr 3 detectors did not show immediate polarization prominently until a flux higher than 10 10 photons s –1 mm –2 . Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr 3 . We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr 3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superconducting detectors for rare event searches in experimental astroparticle physics

Superconducting detectors have become an important tool in experimental astroparticle physics, which seeks to provide a fundamental understanding of the Universe. In particular, such detectors have demonstrated excellent potential in two challenging research areas involving rare event search experiments, namely, the direct detection of dark matter (DM) and the search for neutrinoless double beta decay. Here, we review the superconducting detectors that have been and are planned to be used in these two categories of experiments. We first provide brief histories of the two research areas and outline their significance and challenges in astroparticle physics. Then, we present an extensive overview of various types of superconducting detectors with a focus on sensor technologies and detector physics, which are based on calorimetric measurements and heat flow in the detector components. Finally, we introduce leading experiments and discuss their future prospects for the detection of DM and the search for neutrinoless double beta decay employing superconducting detectors.

transition edge sensors↗

Characterization of the Cherenkov Photon Background for Low-noise Silicon Detectors in Space

Future space observatories that seek to perform imaging and spectroscopy of faint astronomical sources will require ultra-low-noise detectors that are sensitive over a broad wavelength range. Silicon charge-coupled devices (CCDs), such as EMCCDs, skipper CCDs, multi-amplifier sensing CCDs, and single-electron sensitive read out CCDs have demonstrated the ability to detect and measure single photons from X-ray energies to near the silicon band gap (∼1.1 μm), making them candidate technologies for this application. Here, in this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic cosmic rays traversing a silicon detector. We present a model for Cherenkov photon production and absorption that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low-noise silicon detectors in space. We study how the Cherenkov background rate depends on detector thickness, variations in solar activity, and the contribution of heavy cosmic ray species (Z > 2). We find that for thick silicon detectors, such as those required to achieve high quantum efficiency at long wavelengths, the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds. We apply our Cherenkov background model to simulated spectroscopic observations of extra-solar planets, and we find that thick detectors continue to outperform their thinner counterparts at longer wavelengths despite a larger Cherenkov background rate. Furthermore, we find that minimal masking of cosmic-ray tracks continues to maximize the signal-to-noise ratio of very faint sources despite the existence of extended halos of Cherenkov photons.

Astronomical detectors↗