Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A search for sources of ultra high energy gamma rays at air shower energies with Ooty EAS array

A 24 detector extensive air shower array is being operated at Ootacamund (2200 m altitude, 11.4 deg N latitude) in southern India to search for sources of Cosmic gamma rays of energies greater then 5 x 10 to the 13th power eV. The angular resolution of the array has been experimentally estimated to be better than about 2 deg. Since June '84, nearly 2.5 million showers have been collected and their arrival directions determined. These showers are being studied to search for very high energy gamma ray emission from interesting astrophysical objects such as Cygnus X-3, Crab pulsar and Geminga.

Tonwar, S. C.↗

CdZnTe Image Detectors for Hard-X-Ray Telescopes

Arrays of CdZnTe photodetectors and associated electronic circuitry have been built and tested in a continuing effort to develop focal-plane image sensor systems for hard-x-ray telescopes. Each array contains 24 by 44 pixels at a pitch of 498 m. The detector designs are optimized to obtain low power demand with high spectral resolution in the photon- energy range of 5 to 100 keV. More precisely, each detector array is a hybrid of a CdZnTe photodetector array and an application-specific integrated circuit (ASIC) containing an array of amplifiers in the same pixel pattern as that of the detectors. The array is fabricated on a single crystal of CdZnTe having dimensions of 23.6 by 12.9 by 2 mm. The detector-array cathode is a monolithic platinum contact. On the anode plane, the contact metal is patterned into the aforementioned pixel array, surrounded by a guard ring that is 1 mm wide on three sides and is 0.1 mm wide on the fourth side so that two such detector arrays can be placed side-by-side to form a roughly square sensor area with minimal dead area between them. Figure 1 shows two anode patterns. One pattern features larger pixel anode contacts, with a 30-m gap between them. The other pattern features smaller pixel anode contacts plus a contact for a shaping electrode in the form of a grid that separates all the pixels. In operation, the grid is held at a potential intermediate between the cathode and anode potentials to steer electric charges toward the anode in order to reduce the loss of charges in the inter-anode gaps. The CdZnTe photodetector array is mechanically and electrically connected to the ASIC (see Figure 2), either by use of indium bump bonds or by use of conductive epoxy bumps on the CdZnTe array joined to gold bumps on the ASIC. Hence, the output of each pixel detector is fed to its own amplifier chain.

Chen, C. M. Hubert↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral Infrared Images of Terrain

Images at 128 wavelengths allow direct identification of many earth surface materials. Two reports describe advanced airborne spectrometer that creates images of terrain at many wavelengths. Airborne imaging spectrometer (AIS) produces two-dimensional images in 128 spectral bands in 1.2-to-2.4-micrometer wavelength region. Images created by 32-by-32 array of mercury cadmium telluride detector elements. Array views swath of Earth below moving aircraft. Used for agricultural, geological, and other surveys.

Vane, G.↗

Array Technology for Terahertz Imaging

Heterodyne terahertz (0.3 - 3THz) imaging systems are currently limited to single or a low number of pixels. Drastic improvements in imaging sensitivity and speed can be achieved by replacing single pixel systems with an array of detectors. This paper presents an array topology that is being developed at the Jet Propulsion Laboratory based on the micromachining of silicon. This technique fabricates the array's package and waveguide components by plasma etching of silicon, resulting in devices with precision surpassing that of current metal machining techniques. Using silicon increases the versatility of the packaging, enabling a variety of orientations of circuitry within the device which increases circuit density and design options. The design of a two-pixel transceiver utilizing a stacked architecture is presented that achieves a pixel spacing of 10mm. By only allowing coupling from the top and bottom of the package the design can readily be arrayed in two dimensions with a spacing of 10mm x 18mm.

Terahertz↗

All-epitaxial resonant cavity enhanced long-wave infrared detectors for focal plane arrays

Here, we demonstrate a monolithic all-epitaxial resonant-cavity architecture for long-wave infrared photodetectors with substrate-side illumination. An nBn detector with an ultra-thin (t ≈ 350 nm) absorber layer is integrated into a leaky resonant cavity, formed using semitransparent highly doped (n⁺⁺) epitaxial layers, and aligned to the anti-node of the cavity’s standing wave. The devices are characterized electrically and optically and demonstrate an external quantum efficiency of 25% at T ¼ 180 K in an architecture compatible with focal plane array configurations.

42 ENGINEERING↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

SRAM As An Array Of Energetic-Ion Detectors

Static random-access memory (SRAM) designed for use as array of energetic-ion detectors. Exploits well-known tendency of incident energetic ions to cause bit flips in cells of electronic memories. Design of ion-detector SRAM involves modifications of standard SRAM design to increase sensitivity to ions. Device fabricated by use of conventional complementary metal oxide/semiconductor (CMOS) processes. Potential uses include gas densimetry, position sensing, and measurement of cosmic-ray spectrum.

Buehler, Martin G.↗

High resolution spectroscopy from low altitude satellites

The P 78 1 satellite to be placed in a synchronous polar orbit at an altitude of 550-660 km will carry two identical high resolution spectrometers each consisting of a single (approximately 85 cc) intrinsic germanium IGE detector. The payload also includes a pair of phoswitch scintillators, an array of CdTe detectors and several particle detectors, all of which are mounted on the wheel of the satellite. The intrinsic high purity IGE detectors receive cooling from two Stirling cycle refrigerators and facilitate the assembly of large and complex detector arrays planned for the next generation of high sensitivity instruments such as those planned for the gamma ray observatory. The major subsystems of the spectrometer are discussed as well as its capabilities.

Nakano, G. H.↗

Integrating 128 element InSb array - Recent results

There has been a continuing evolution toward larger arrays of infrared detectors, and the technology base derived from the Galileo Near Infrared Mapping Spectrometer (NIMS) has been expanded to linear arrays including from 128 to 512 elements. This advance is based on the commercial availability of high-quality InSb photodiodes and 128/256 element FET switch MUX's (multiplexing elements). The present investigation is concerned with an experimental 128-element linear imager using InSb detectors and silicon MUX for readout. Attention is given to detector array electrical characteristics, the detector readout architecture, noise, and special effects.

Bailey, G.↗

Spatially resolved x-ray detection with photonic crystal scintillators

We study the self-collimation phenomenon in photonic crystals (PhC) of wide bandgap materials for ultra-fast and high spatial resolution x-ray detection. We work on various heavy inorganic scintillators: BaF 2 , GaN, ZnO, CsI:Tl, NaI:Tl, LYSO, WO 4 compounds, and plastic scintillators. Conventional scintillator detectors do not rely on a direct detection mechanism; hence, they require intricate design and fabrication processes. We offer a PhC design to observe self-collimation phenomena and overcome the ongoing spatial resolution challenges with these types of materials. We investigate the photonic band diagrams and iso-frequency contours. Fourier transforms based on finite-difference time-domain and frequency domain simulations are done for verifying and analyzing the self-collimation with the selected material. Light extraction efficiency at the PhC–air interface, depending on the truncation distance from the excitation point, is measured. Beam divergence values are calculated at 1 mm propagation distance. The vertical field profiles are obtained to observe the confinement. For the spatial resolution analysis, cross-sectional beam profiles have been examined. Furthermore, Gaussian envelopes are fitted to beam profiles for a consistent data analysis, and full-width-at-half-maximum values are considered. As a result, we theoretically prove and demonstrate the spatially resolved x-ray detection at the sub-micrometer level for a wide range of scintillator materials.

36 MATERIALS SCIENCE↗

Cosmic ray experimental observations

The current experimental situation in cosmic ray studies is discussed, with special emphasis on the development of new detector systems. Topics covered are the techniques for particle identification, energy measurements, gas Cerenkov counters, magnet spectrometers, ionization spectrometers, track detectors, nuclear emulsions, multiparameter analysis using arrays of detectors, the Goddard ionization spectrometer, charge spectra, relative abundances, isotope composition, antinuclei in cosmic rays, electrons, the measurement of cosmic ray arrival directions, and the prehistory of cosmic rays.

Balasubrahmanyan, V. K.↗

MOLA II Laser Transmitter Calibration and Performance

The goal of the document is to explain the algorithm for determining the laser output energy from the telemetry data within the return packets from MOLA II. A simple algorithm is developed to convert the raw start detector data into laser energy, measured in millijoules. This conversion is dependent on three variables, start detector counts, array heat sink temperature and start detector temperature. All these values are contained within the return packets. The conversion is applied to the GSFC Thermal Vacuum data as well as the in-space data to date and shows good correlation.

Afzal, Robert S.↗

The Atacama Cosmology Telescope: Data Characterization and Map Making

We present a description of the data reduction and mapmaking pipeline used for the 2008 observing season of the Atacama Cosmology Telescope (ACT). The data presented here at 148 GHz represent 12% or the 90 TB collected by ACT from 2007 to 2010. In 2008 we observed for 136 days, producing a total of 142h of data (11 TB for the 148 GHz band only), with a daily average of 10.5 h of observation. From these, 108.5 h were devoted to 850 sq deg stripe (11.2 h by 9 deg.1) centered on a declination of -52 deg.7, while 175 h were devoted to a 280 square deg stripe (4.5 h by 4 deg.8) centered at the celestial equator. We discuss sources of statistical and systematic noise, calibration, telescope pointing and data selection. Out of 1260 survey hours and 1024 detectors per array, 816 h and 593 effective detectors remain after data selection for this frequency band, yielding a 38 % survey efficiency. The total sensitivity in 2008, determined from the noise level between 5 Hz and 20 Hz in the time-ordered data stream (TOD), is 32 muK square root of s in CMB units. Atmospheric brightness fluctuations constitute the main contaminant in the data and dominate the detector and noise covariance at low frequencies in the TOD. The maps were made by solving the lease squares problem using the Preconditioned Conjugate Gradient method, incorporating the details of the detector and noise correlations. Cross-correlation with WMAP sky maps as well as analysis from simulations reveal the our maps are unbiased at l > 300. This paper accompanies the public release of the 148 GHz southern stripe maps from 2008. The techniques described here will be applied to future maps and data releases.

Duenner, Rolando↗

Integration of Multilevel Superconducting Buried Wiring Layers with Transition-Edge Sensor Detectors for Large Scale Arrays

Lynx, one of the four mission concepts under consideration for the next Astrophysics DecadalReview, will include a microcalorimeter array consisting of more than 100,000 pixels in a compact arrangement with absorber pitch as small as 25 microns. In order to realize the desired array scale, fine-pitch multi-level superconducting wiring with high yield, compatible with rapid expansion of our hydra absorber designs, is essential. We have demonstrated a method of integrating transition edge sensor (TES) microcalorimeters with suitable multilevel buried wiring, fabricated at MIT Lincoln Laboratory using advanced tools dedicated to superconducting circuit fabrication. The TES Mo/Au bilayer is deposited on a high-quality oxide surface created by chemical-mechanical polishing, allowing tight specifications on the TES superconducting transition and link conductivity to be achieved even though the process order has been inverted. The TESs contact the top-level niobium wiring through vias etched through silicon dioxide down to the topmost wiring layer. The article discusses the overall fabrication process, as wellas the behavior of sensors with different via designs, proximity structures, and lateral sizes. An initial iteration of the integrated fabrication process indicates that microcalorimeters fabricated in this way should meet mission specifications using a Mo/Au bilayer with a reasonable critical temperature below 100 mK.

Detector↗