Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Development of a Faraday cup fast ion loss detector for keV beam ions

The development and testing of a Faraday cup fast-ion loss detector capable of measuring sub 100 keV particles is documented. Such measurement capabilities play an important role in the assessment of particle confinement of nuclear fusion experiments. The detector is manufactured using thin-film deposition techniques, building upon previous work using discrete foils. This new manufacturing method allows the form factor of the sensor to become that of essentially a microchip. Analysis of the diagnostic response is performed using Monte-Carlo particle simulations. These simulations show peaks in the detector response at 40 and 70 keV. The sensor is then tested in a tunable linear accelerator capable of accelerating protons from 20 to 120 keV. Finally, the detector response was found to be well matched to simulations. Improvements to the design to facilitate robustness are discussed.

47 OTHER INSTRUMENTATION↗

Predicting the sensitivity of the beryllium/scintillator layer neutron detector using Monte Carlo and experimental response functions

A methodology for obtaining empirical curves relating absolute measured scintillation light output to beta energy deposited is presented. Output signals were measured from thin plastic scintillator using NIST traceable beta and gamma sources and MCNP5 was used to model the energy deposition from each source. Combining the experimental and calculated results gives the desired empirical relationships. To validate, the sensitivity of a beryllium/scintillator-layer neutron activation detector was predicted and then exposed to a known neutron fluence from a Deuterium-Deuterium fusion plasma (DD). The predicted and the measured sensitivity were in statistical agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bias Selective Operation of Sb-Based Two-Color Photodetectors

Multicolor detectors have a strong potential to replace conventional single-color detectors in application dealing with the simultaneous detection of more than one wavelength. This will lead to the reduction of heavy and complex optical components now required for spectral discrimination for multi-wavelengths applications. This multicolor technology is simpler, lighter, compact and cheaper with respect to the single-color ones. In this paper, Sb-based two-color detectors fabrication and characterization are presented. The color separation is achieved by fabricating dual band pn junction on a GaSb substrate. The first band consists of an InGaAsSb pn junction for long wavelength detection, while the second band consists of a GaSb pn junction for shorter wavelength detection. Three metal contacts were deposited to access the individual junctions. Surface morphology of multi-layer thin films and also device characteristics of quasi-dual band photodetector were characterized using standard optical microscope and electro-optic techniques respectively. Dark current measurements illustrated the diode behavior of both lattice-matched detector bands. Spectral response measurements indicated either independent operation of both detectors simultaneously, or selective operation of one detector, by the polarity of the bias voltage, while serially accessing both devices.

Abedin, M. N.↗

Increasing flame ionization detector (FID) sensitivity using post-column oxidation–methanation

The flame ionization detector (FID) is a robust tool in gas chromatography (GC) due to its sensitivity and linear response in the detection of common organic compounds. However, FID response to oxygenated or highly functionalized organic molecules is low, or in some cases non-existent, making it difficult or impossible to detect and quantify some organic compounds. In this work, the combination of a GC/FID system with a catalytic microreactor, which performs post-column combustion–methanation to convert organic compounds to methane, is shown to be an effective approach for quantifying low-response organic compounds. Molecules that were previously undetectable by conventional FID, including carbon monoxide and carbon dioxide, respond with the same high response of methane in the FID. Low-response molecules, including formaldehyde, formic acid, formamide, and ten other oxygenates also demonstrated enhanced detector response equivalent to that of methane in the FID. Here, the linear response of the FID to these molecules and the equivalent sensitivity to methane indicate that accurate quantification is possible without the usual calibration-corrections (e.g., response factors or correction factors) to the FID response.

99 GENERAL AND MISCELLANEOUS↗

Improved measurements of the β -decay response of liquid xenon with the LUX detector

Here, we report results from an extensive set of measurements of the β-decay response in liquid xenon. These measurements are derived from high-statistics calibration data from injected sources of both 3 H and 14 C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm{sup 2} and 50 J/cm{sup 2} on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the longest breast exposure time allowable under FDA standards. Department of Defense (DOD) Breast Cancer Research Program IDEA Award W81XWH-11-1-0332; National Institutes of Health (NIH) Grant T32 EB002103-21 from the National Institute of Biomedical Imaging and Bioengineering (NIBIB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Time delay measurement in the frequency domain

Pump–probe studies at synchrotrons using X-ray and laser pulses require accurate determination of the time delay between pulses. This becomes especially important when observing ultrafast responses with lifetimes approaching or even less than the X-ray pulse duration (~100 ps). The standard approach of inspecting the time response of a detector sensitive to both types of pulses can have limitations due to dissimilar pulse profiles and other experimental factors. Here, a simple alternative is presented, where the frequency response of the detector is monitored versus time delay. Measurements readily demonstrate a time resolution of ~1 ps. Improved precision is possible by simply extending the data acquisition time.

43 PARTICLE ACCELERATORS↗

Optimization of the frequency response of a novel GaAs plasmonic terahertz detector

Previously there was reported a new type of high-speed plasmonic THz detector that can operate at room temperature. As an extension of that work, the sensitivity of the detector was investigated over a wide range of sub-THz frequencies. The measured frequency response is not purely monotonic but exhibits oscillatory behaviour with a number of maxima and minima. Our study reveals that such frequency dependence is caused by the interference of electromagnetic waves inside the detector substrate, as the frequencies of these extrema are found to be governed by the substrate thickness. We demonstrate that sensitivity of this type of detector can be optimized for the desired operating frequency within 0.06–0.7 THz spectrum by adjusting the substrate thickness. We also show that a monotonic frequency response with eliminated minima can be achieved by mounting the detector on a specially designed silicon lens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗

Evaluation of multi-spectral linear array detectors for spaceborne applications

A NASA laboratory for evaluating linear detector arrays for remote sensing applications from the visible to shortwave infrared is described. Nominal requirements are presented on the critical parameters of signal-to-noise ratio, modulation transfer function, response linearity, dynamic range, and detector-to-detector response uniformity. Results of tests on a custom developed multi-spectral linear array from RCA and two commercial arrays from Texas Instruments and Reticon for the visible and near-infrared are presented. The custom array was clearly superior in signal-to-noise ratio and dynamic range to its off-the-shelf counterparts. Allthe arrays were found to have somewhat less than desirable modulation transfer functions, but excellent response linearity.

Kalshoven, James E., Jr.↗

Response of alpha particles in hexagonal boron nitride neutron detectors

Here, thermal neutron detectors were fabricated from 10 B enriched h-BN epilayers of different thicknesses. The charge carrier generation and energy loss mechanisms as well as the range of alpha daughter particles generated by the nuclear reaction between thermal neutrons and 10 B atoms in hexagonal boron nitride (h-BN) thermal neutron detectors have been investigated via their responses to alpha particles from a 210 Po source. The ranges of alpha particles in h-BN were found to be anisotropic, which increase with the angle (θ) between the trajectory of the alpha particles and c-axis of the h-BN epilayer following (cos θ) -1 and are 4.6 and 5.6 μm, respectively, for the alpha particles with energies of 1.47 MeV and 1.78 MeV at θ = 0. However, the energy loss of an alpha particle inside h-BN is determined by the number of layers it passes through with a constant energy loss rate of 107 eV per layer due to the layered structure of h-BN. Roughly 5 electron-hole pairs are generated when an alpha particle passes through each layer. It was also shown that the durability of h-BN thermal neutron detectors is excellent based on the calculation of boron vacancies generated (or 10 B atoms consumed) by neutron absorption. Finally, the results obtained here provide useful insights into the mechanisms of energy loss and charge carrier generation inside h-BN detectors and possible approaches to further improve the overall performance of h-BN thermal neutron detectors, as well as the ultimate spatial resolution of future neutron imaging devices or cameras based on h-BN epilayers.

47 OTHER INSTRUMENTATION↗

Evaluation of Photodiode and Thermopile Pyranometers for Photovoltaic Applications: Preprint

Accurately determining PV module performance in the field requires measurement of solar irradiance reaching the PV panel at a high level of accuracy and known uncertainty. Silicon detectors used in various solar energy measuring instruments including reference cells are potentially an attractive choice for multiple reasons that include faster responsivity than thermopile detectors, cheaper cost and lower maintenance. The main drawback though is the fact that the silicon detectors are only spectrally responsive in a narrow part of the solar spectrum. Therefore, to determine broadband solar irradiance a calibration factor that converts the narrowband response to broadband is required. Normally this calibration factor is a single number determined under standard conditions but then used for various scenarios including varying air-mass, panel orientation and atmospheric conditions. This would not have been an issue if all wavelengths that form the broadband spectrum responded uniformly to atmospheric constituents. Unfortunately the scattering and absorption signature varies widely across wavelengths and the calibration factor computed under certain test conditions is not appropriate for other conditions. This paper lays out the issues that will arise from the use of silicon detectors for PV performance measurement in the field. We also present a comparison of simultaneous spectral and broadband measurements from silicon and thermopile detectors and estimated measurement errors when using silicon devices for both array performance and resource assessment.

14 SOLAR ENERGY↗

Experimental approaches for the development of gamma spectroscopy well logging system

This article discusses experimental approaches for the development of gamma spectroscopy well logging system. Considering the size of borehole sonde, we customize 2 x 2 inches inorganic scintillators and the system including high voltage, preamplifier, amplifier and multichannel analyzer (MCA). The calibration chart is made by test using standard radioactive sources so that the measured count rates are expressed by energy spectrum. Optimum high-voltage supplies and the measurement parameters of each detector are set up by experimental investigation. Also, the responses of scintillation detectors have been examined by analysis according to the distance between source and detector. Because gamma spectroscopy well logging needs broad spectrum, high sensitivity and resolution, the energy resolution and sensitivity as a function of gamma ray energy are investigated by analyzing the gamma ray activities of the radioactive sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Landsat 9 Thermal Infrared Sensor 2 Subsystem-Level Spectral Test Results

Results from the Thermal Infrared Sensor 2 (TIRS-2) prelaunch spectral characterization at telescope and detector subsystem level are presented. The derived relative spectral response (RSR) shape is expected to be very similar to the instrument-level spectral response and provides an initial estimate of the RSR and its differences to the component-level RSR measurements. Such differences were observed at TIRS- 1 and are likely a result of angular dependence of the spectral response of the detector. The subsystem RSR measurements also provide an opportunity for a preliminary assessment of the spectral requirements. Final requirements verification will be performed at future thermal vacuum environmental testing with the fully assembled TIRS-2 instrument.

TIRS-2↗

Compton polarimeter during the Qweak experiment

Compton Polarimeter was successfully used during the Q$_{weak}$ experiment from Nov 2010 to May 2012 in Hall C, Jefferson Lab. In this newly installed Compton polarimeter the electron beam collides with green laser stored in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in four crystals of PbWO$_4$ detector. The analyzing power is computed using a Geant4 Monte Carlo simulation to match the real detector energy resolution and non-linearity in the response of the detector are folded in. The Compton polarimeter has achieved the design goals of 1\% statistical uncertainty per hour and we expect to achieve 1\% systematic uncertainty. We have done specific tests to understand various properties of the electron and photon detectors. We will share our study of the contributions to the electron and photon detector's systematic uncertainty along with the preliminary polarization results.

Narayan, Amrendra↗

Studies on the response of a water-Cherenkov detector of the Pierre Auger Observatory to atmospheric muons using an RPC hodoscope

Extensive air showers, originating from ultra-high energy cosmic rays, have been successfully measured through the use of arrays of water-Cherenkov detectors (WCDs). Sophisticated analyses exploiting WCD data have made it possible to demonstrate that shower simulations, based on different hadronic-interaction models, cannot reproduce the observed number of muons at the ground. The accurate knowledge of the WCD response to muons is paramount in establishing the exact level of this discrepancy. In this work, we report on a study of the response of a WCD of the Pierre Auger Observatory to atmospheric muons performed with a hodoscope made of resistive plate chambers (RPCs), enabling us to select and reconstruct nearly 600 thousand single muon trajectories with zenith angles ranging from 0$^\circ$ to 55$^\circ$. Comparison of distributions of key observables between the hodoscope data and the predictions of dedicated simulations allows us to demonstrate the accuracy of the latter at a level of 2%. As the WCD calibration is based on its response to atmospheric muons, the hodoscope data are also exploited to show the long-term stability of the procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Landsat-7 ETM+: 12 years On-Orbit Reflective-Band Radiometric Performance

The Landsat-7 ETM+ sensor has been operating on orbit for more than 12 years and characterizations of its performance have been ongoing over this period. In general, the radiometric performance of the instrument has been remarkably stable: (1) Noise performance has degraded by 2% or less overall, with a few detectors displaying step changes in noise of 2% or less, (2) Coherent noise frequencies and magnitudes have generally been stable, though the within-scan amplitude variation of the 20kHz noise in bands 1 and 8 disappeared with the failure of the scan line corrector and a new similar frequency noise (now about 18kHz) has appeared in two detectors in band 5 and increased in magnitude with time, (3) Bias stability has been better than 0.25 DN out of a normal value of 15 DN in high gain, (4) Relative gains, the differences in response between the detectors in the band, have generally changed by 0.1% or less over the mission, with the exception of a few detectors with a step response change of 1% or less and (5) Gain stability averaged across all detectors in a band, which is related to the stability of the absolute calibration, has been more stable than the techniques used to measure it. Due to the inability to confirm changes in the gain (beyond a few detectors that have been corrected back to the band average), ETM+ reflective band data continues to be calibrated with the pre-launch measured gains. In the worst case some bands may have changed as much as 2% in uncompensated absolute calibration over the 12 years.

Markham, Brian L.↗