Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Autoencoder-Based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter

The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online data quality monitoring of the CMS electromagnetic calorimeter is a vital operational tool that allows detector experts to quickly identify, localize, and diagnose a broad range of detector issues that could affect the quality of physics data. A real-time autoencoder-based anomaly detection system using semi-supervised machine learning is presented enabling the detection of anomalies in the CMS electromagnetic calorimeter data. A novel method is introduced which maximizes the anomaly detection performance by exploiting the time-dependent evolution of anomalies as well as spatial variations in the detector response. The autoencoder-based system is able to efficiently detect anomalies, while maintaining a very low false discovery rate. The performance of the system is validated with anomalies found in 2018 and 2022 LHC collision data. In addition, the first results from deploying the autoencoder-based system in the CMS online data quality monitoring workflow during the beginning of Run 3 of the LHC are presented, showing its ability to detect issues missed by the existing system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of phosphorylated mitogen-activated protein kinase in the developing spinal cord of the mouse embryo

Highlights: {yields} We detected physiologically phosphorylated MAPKs in developing spinal cord. {yields} We detected physiologically phosphorylated MAPKs by an improved method. {yields} p-ERK1/2 and p-JNK1/2 were detected in the marginal layer and the dorsal horn. {yields} p-ERK1/2 and p-JNK1/2 might play critical roles in the developing spinal cord. {yields} Constructing phosphoprotein atlases will be possible if expanding this work. -- Abstract: Global understanding of the proteome is a major research topic. The comprehensive visualization of the distribution of proteins in vivo or the construction of in situ protein atlases may be a valuable strategy for proteomic researchers. Information about the distribution of various proteins under physiological and pathological conditions should be extremely valuable for the basic and clinical sciences. The mitogen-activated protein kinase (MAPK) cascade plays an essential role in intracellular signaling in organisms. This cascade also regulates biological processes involving development, differentiation, and proliferation. Phosphorylation and dephosphorylation are integral reactions in regulating the activity of MAPKs. Changes in the phosphorylation state of MAPKs are rapid and reversible; therefore, the localizations of physiologically phosphorylated MAPKs in vivo are difficult to accurately detect. Furthermore, phosphorylated MAPKs are likely to change phosphorylated states through commonly used experimental manipulations. In the present study, as a step toward the construction of in situ phosphoprotein atlases, we attempted to detect physiologically phosphorylated MAPKs in vivo in developing spinal cords of mice. We previously reported an improved immunohistochemical method for detecting unstable phosphorylated MAPKs. The distribution patterns of phosphorylated MAPKs in the spinal cords of embryonic mice from embryonic day 13 (E13) to E17 were observed with an improved immunohistochemical method. Phosphorylated extracellular signal-regulated kinase 1/2 (p-ERK1/2) and phosphorylated c-Jun N-terminal kinase 1/2 (p-JNK1/2) were strongly observed in the marginal layer and the dorsal horn from E13 to E17. Our results suggest that p-ERK1/2 and p-JNK1/2 play critical roles in the developing spinal cord. Constructing phosphoprotein atlases will be possible in the future if this work is systematically developed on a larger scale than we presented here.

60 APPLIED LIFE SCIENCES↗

A rapid and efficient newly established method to detect COL1A1-PDGFB gene fusion in dermatofibrosarcoma protuberans

Highlights: Black-Right-Pointing-Pointer We developed new method to rapidly identify COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer New PCR method using a single primer pair detected COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer This is the first report of DFSP with a novel COL1A1 breakpoint in exon 5. -- Abstract: The detection of fusion transcripts of the collagen type 1{alpha}1 (COL1A1) and platelet-derived growth factor-BB (PDGFB) genes by genetic analysis has recognized as a reliable and valuable molecular tool for the diagnosis of dermatofibrosarcoma protuberans (DFSP). To detect the COL1A1-PDGFB fusion, almost previous reports performed reverse transcription polymerase chain reaction (RT-PCR) using multiplex forward primers from COL1A1. However, it has possible technical difficulties with respect to the handling of multiple primers and reagents in the procedure. The objective of this study is to establish a rapid, easy, and efficient one-step method of PCR using only a single primer pair to detect the fusion transcripts of the COL1A1 and PDGFB in DFSP. To validate new method, we compared the results of RT-PCR in five patients of DFSP between the previous method using multiplex primers and our established one-step RT-PCR using a single primer pair. In all cases of DFSP, the COL1A1-PDGFB fusion was detected by both previous method and newly established one-step PCR. Importantly, we detected a novel COL1A1 breakpoint in exon 5. The newly developed method is valuable to rapidly identify COL1A1-PDGFB fusion transcripts in DFSP.

60 APPLIED LIFE SCIENCES↗

Evaluation of a high-throughput method for processing sponge-stick samples to detect viable, non-spore-forming biothreat agents

After a bioterrorism incident, surface sampling is often used to determine the extent of contamination and exposure, guiding decontamination efforts and decisions for re-occupancy of affected sites. The sponge-stick (SS) is a preferred and commonly used device for sample collection to detect both spore-forming and non-spore-forming biothreat agents from non-porous surfaces. Here, in this study, a recently developed high-throughput method (HTM) for processing SS samples to detect viable Bacillus anthracis spores was adapted for detection of non-spore-forming biothreat agents, Yersinia pestis and Francisella tularensis. The scalable HTM was used to process up to 20 SS samples simultaneously, compared to the current stomacher-based method which processes one SS at a time. Comparisons of the HTM and the stomacher-based method were statistically indistinguishable for most experiments (P > 0.05) with HTM recoveries of 37–60 % for Y. pestis inoculated at 102–103 cells/SS and held 48 h at 4 °C to mimic sample transport/storage. The HTM was integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis to detect viable Y. pestis in the presence of particulate contamination (Arizona Test Dust, ATD). This approach detected Y. pestis inoculated at 20 cells/SS and ATD did not impact detection (P > 0.05). F. tularensis showed significantly lower recoveries between no-hold time and 48-h hold time (4 °C, P < 0.05) using the HTM, which further testing showed could be due to toxicity of the neutralizing buffer used for SS pre-wetting. With modifications, this method could enhance throughput capacity while maintaining similar recovery efficiencies to current methods for other non-spore-forming bacterial pathogens.

Biological and medical sciences↗

A cut-off in ocular chemesthesis from vapors of homologous alkylbenzenes and 2-ketones as revealed by concentration-detection functions

Studies of homologous series of environmental vapors have shown that their chemesthetic (i.e., sensory irritation) potency increases with carbon chain length (that is, their detection thresholds decrease) until they reach a homolog that fails to be detected, even at vapor saturation. All ensuing homologs cannot be detected either. In this investigation, we measured concentration-detection (i.e., psychometric) functions for ocular chemesthesis from homologous alkylbenzenes (pentyl, hexyl, and heptyl benzene) and 2-ketones (undecanone, dodecanone, and tridecanone). Using a three-alternative forced-choice procedure against air blanks, we tested a total of 18 to 24 subjects, about half of them females, average age 31 years, ranging from 18 to 56 years. Stimuli were generated and presented by a computer-controlled, vapor delivery device whose output was quantified by gas chromatography. Exposure time was 6 s and delivery flow 2.5 L/min. Within the context of present and previous findings, the outcome indicated that the functions for heptylbenzene and 2-tridecanone reached a plateau where further increases in concentration did not enhance detection. We conclude that: a) a cut-off point in ocular chemesthetic detection is reached along homologous alkylbenzenes and 2-ketones at the level of heptylbenzene and 2-tridecanone, respectively, and b) the observed effect rests on the homologs exceeding a critical molecular size (or dimension) rather than on them failing to achieve a high enough vapor concentration.

60 APPLIED LIFE SCIENCES↗

Membrane-Extraction Ion Mobility Spectrometry for In-Situ Detection of Chlorinated Hydrocarbons in Water

Membrane-extraction ion mobility spectrometry (ME-IMS) has been developed for in-situ sampling and analysis of trace chlorinated hydrocarbons in water in a single procedure. The sampling is configured so that aqueous contaminants permeate through a spiral hollow polydimethylsiloxane (PDMS) membrane and are carried away by a vapor flow through the membrane tube. The extracted analyte flows into an atmospheric pressure chemical ionization (APCI) chamber and is analyzed in a home-made IMS analyzer. PDMS membrane is found to effectively extract chlorinated hydrocarbon solvents from liquid phase to vapor. The specialized IMS analyzer has been found to have resolutions of R=33 and 41, respectively, for negative- and positive-modes and is capable of detecting aqueous tetrachloroethylene (PCE) and trichloroethylene (TCE) as low as 80 g/L and 74 g/L in negative ion mode, respectively. The time-dependent characteristics of sampling and detection of TCE are both experimentally and theoretically studied for various concentrations, membrane lengths, and flow rates. These characteristics demonstrate that membrane-extraction IMS is feasible for the continuous monitoring of chlorinated hydrocarbons in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed Cancer Biomarker Detection Using Quartz-based Photonic Crystal Surfaces

A photonic crystal (PC) surface is demonstrated as a high-sensitivity platform for detection of a panel of 21 cancer biomarker antigens using a sandwich enzyme-linked immunosorbent assay (ELISA) microarray format. A quartz-based PC structure fabricated by nanoimprint lithography, selected for its low autofluorescence, supports two independent optical resonances that simultaneously enable enhancement of fluorescence detection of biomarkers and label-free quantification of the density of antibody capture spots. A detection instrument is demonstrated that supports fluorescence and label-free imaging modalities, with the ability to optimize the fluorescence enhancement factor on a pixel-by-pixel basis throughout the microarray using an angle-scanning approach for the excitation laser that automatically compensates for variability in surface chemistry density and capture spot density. Measurements show that the angle-scanning illumination approach reduces the coefficient of variation of replicate assays by 20–99% compared to ordinary fluorescence microscopy, thus supporting reduction in limits of detectable biomarker concentration. Using the PC resonance, biomarkers in mixed samples were detectable at the lowest concentrations tested (2.1–41 pg/mL), resulting in a three-log range of quantitative detection.

Huang, Cheng-Sheng↗

Confocal Raman Microscopy for in Situ Detection of Solid-Phase Extraction of Pyrene into Single C 18 –Silica Particles

Solid-phase extraction (SPE) is a well known method for separating and pre concentrating analytes prior to ex-situ detection and quantification. Despite advances in miniaturization of solid-phase extraction, the technique has not evolved to meet the needs for detection in small scale microfluidic devices. While successful efforts have led to smaller scale extractors that allow preconcentration from small volumes, detection within correspondingly small volumes has remained out of reach because of analyte dilution during a post extraction transfer or “wash off” step prior to detection. In this work, successful extraction into sub-picoliter collection volumes is accomplished by using a single chromatographic particle as an extractor; wash off dilution is totally avoided by using confocal Raman microscopy for in-situ detection within the single-particle collection phase. Specifically, micromolar concentrations of pyrene in methanol water solution were equilibrated with an individual C 18 -functionalized silica particle, and Raman spectra were acquired from a small confocal sampling volume (~1 fL) within the particle interior. By comparing the Raman scattering intensity of the pyrene with that of the C 18 -chains in the stationary phase, it was possible to quantify the equilibrium coverage of pyrene relative to the C 18 chains. Spectroscopic isotherms were measured to determine the saturation surface coverage of pyrene relative to C 18 -chains and to study how the preconcentration equilibrium can be controlled by the source-phase solution composition. For extraction from aqueous solutions having the lowest methanol concentration (5% by volume), the preconcentration factor for pyrene into the particle was found to be 4.8 (±0.8) × 10 4 , which allowed detection of pyrene extracted from a 10 nM solution into a 0.52-pL particle volume.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Detection of Single Molecules in Fluorescence Microscopy Images

Fluorescence imaging and counting of single molecules adsorbed or bound to surfaces are being employed in a number of quantitative analysis applications. Reliable molecular counts with knowledge of counting uncertainties, both false-positive and false-negative probabilities, are critical to these applications. By counting stationary single molecules on a surface, spatial criteria may be applied to the image analysis to improve confidence in detection, which is especially critical when detecting single fluorescent labels. In this work, we describe a simple approach to incorporating spatial criteria for counting single molecules by using an intensity threshold to locate regions with multiple, adjacent intense pixels, where the size of these regions is guided by the point-spread function of the microscope. By requiring multiple, spatially correlated bright pixels, false-positive events resulting from random samples of background noise are minimized. The reliability of detection is established by quantitative knowledge of the distributions of background and signals. By measuring and modeling both the background and single-molecule intensity distributions, false-positive and false-negative detection probabilities are estimated for arbitrary threshold parameters by using combinatorial statistics. From this theory, detection parameters can be optimized to minimize false-positive and false-negative probabilities, which can be calculated explicitly. For detection of single rhodamine 6G molecules at a threshold set at 2.5 times the standard deviation above background, the false-negative probability was only 1.5%, determined from distributions of single-molecule intensities on well-populated surfaces, and the false-positive probability from background noise was 2.8 spots per 50 × 50 μm image. Furthermore, the false-positive events compare favorably with theoretical probabilities calculated using combinatorial statistical analysis and simulated false-positive events counted in images of random noise.

36 MATERIALS SCIENCE↗

Enhancing the Sensitivity of Solid-State NMR Experiments with Very Low Gyromagnetic Ratio Nuclei with Fast Magic Angle Spinning and Proton Detection

Many transition metals commonly encountered in inorganic materials and organometallic compounds possess NMR-active nuclei with very low gyromagnetic ratios (γ) such as 89 Y, 103 Rh, 109 Ag, and 183 W. A low-γ leads to poor NMR sensitivity and other experimental challenges. Consequently, nuclei with low-γ are often impossible to study with conventional solid-state NMR methods. In this paper, we combine fast magic angle spinning (MAS) and proton detection to enhance the sensitivity of solid-state NMR experiments with very low-γ nuclei by 1–2 orders of magnitude. Coherence transfer between 1 H and low-γ nuclei was performed with low-power double quantum (DQ) or zero quantum (ZQ) cross-polarization (CP) or dipolar refocused insensitive nuclei enhanced by polarization transfer (D-RINEPT). Comparison of the absolute sensitivity of CP NMR experiments performed with proton detection with 1.3 mm rotors and direct detection with 4 mm rotors shows that proton detection with a 1.3 mm rotor provides a significant boost in absolute sensitivity, while requiring approximately 1/40 th of the material required to fill a 4 mm rotor. Fast MAS and proton detection were applied to obtain 89 Y and 103 Rh solid-state NMR spectra of organometallic complexes. Finally, these results demonstrate that proton detection and fast MAS represents a general approach to enable and accelerate solid-state NMR experiments with very low-γ nuclei.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Detection of Intermediate-Amplitude Motion by Solid-State NMR

The coexistence of rigid and mobile molecules or molecular segments abounds in biomolecular assemblies. Examples include the carbohydrate-rich cell walls of plants and intrinsically disordered proteins that contain rigid β-sheet cores. In solid-state nuclear magnetic resonance (NMR) spectroscopy, dipolar polarization transfer experiments are well suited for detecting rigid components, whereas scalar-coupling experiments are well suited for detecting highly mobile components. However, few NMR methods are available to detect the segments that undergo intermediate-amplitude fast motion. Here, we introduce two NMR experiments, a two-dimensional T 2H -filtered CP-hCH correlation and a three-dimensional J-INADEQUATE CCH correlation, to observe this intermediate-amplitude motion. Both experiments involve 1 H detection under fast magic-angle spinning (MAS). By combining 1 H transverse relaxation (T 2H ) filters with dipolar polarization transfer, we suppress the signals of both highly rigid and highly mobile species, thus revealing the signals of intermediate mobile species. 1 H detection under fast MAS is crucial for distinguishing the different motional amplitudes. Here, we demonstrate these techniques on several plant cell wall samples and show that they allow the selective detection and resolution of certain hemicellulose and pectin signals, which are usually masked by the signals of the rigid cellulose and the highly dynamic pectins in purely dipolar and scalar NMR spectra.

59 BASIC BIOLOGICAL SCIENCES↗

Redox-Based Electrochemical Affinity Sensor for Detection of Aqueous Pertechnetate Anion

Rapid, selective, in-situ detection of TcO4- in multicomponent matrices consisting of interfering anions such as the ubiquitous NO3- and Cl- or the isostructural and isoelectronic CrO42- is challenging. Present sensors mostly lack the selectivity to exclude these interferences, or the sensitivity to meet the detection limits that are lower than the drinking water standards across the globe. This work presents an affinity based electrochemical sensor for TcO4- detection that relies on selective reductive precipitation of aqueous TcO4- induced by a capture probe immobilized on an electrode platform. This results in a direct decrease of the electron transfer current, the magnitude of the decrease being proportional to the amount of TcO4- added. Using this approach, we were able to achieve a detection limit of 1x10-10 M, which is lower than the drinking water standard of 5.2x10-10 M set by United States Environmental Protection Agency. Our proposed approach also allowed us to detect TcO4- from a multicomponent groundwater sample obtained from a well at the Hanford site in Washington (well 299-W19-36) that also contained NO3- , Cl- and CrO42-, without discernably affecting the detection limits.

Chatterjee, Sayandev↗

An End-To-End Earthquake Detection Method for Joint Phase Picking and Association Using Deep Learning

Earthquake monitoring by seismic networks typically involves a workflow consisting of phase detection/picking, association, and location tasks. In recent years, the accuracy of these individual stages has been improved through the use of machine learning techniques. Here, in this study, we introduce a new end-to-end approach that improves overall earthquake detection accuracy by jointly optimizing each stage of the detection pipeline. We propose a neural network architecture for the task of multi-station processing of seismic waveforms recorded over a seismic network. This end-to-end architecture consists of three sub-networks: a backbone network that extracts features from raw waveforms, a phase picking sub-network that picks P- and S-wave arrivals based on these features, and an event detection sub-network that aggregates the features from multiple stations to associate and detect earthquakes across a seismic network. We use these sub-networks together with a shift-and-stack module based on back-projection that introduces kinematic constraints on arrival times, allowing the neural network model to generalize to different velocity models and to variable station geometry in seismic networks. We evaluate our proposed method on the STanford EArthquake Dataset (STEAD) and on the 2019 Ridgecrest, CA earthquake sequence. The results demonstrate that our end-to-end approach can effectively pick P- and S-wave arrivals and achieve earthquake detection accuracy rivaling that of other state-of-the-art approaches. Because our approach preserves information across tasks in the detection pipeline, it has the potential to outperform approaches that do not.

58 GEOSCIENCES↗

An Overview of ARTMIP's Tier 2 Reanalysis Intercomparison: Uncertainty in the Detection of Atmospheric Rivers and Their Associated Precipitation

Atmospheric rivers, or long but narrow regions of enhanced water vapor transport, are an important component of the hydrologic cycle as they are responsible for much of the poleward transport of water vapor and result in precipitation, sometimes extreme in intensity. Despite their importance, much uncertainty remains in the detection of atmospheric rivers in large datasets such as reanalyses and century scale climate simulations. To understand this uncertainty, the Atmospheric River Tracking Method Intercomparison Project (ARTMIP) developed tiered experiments, including the Tier 2 Reanalysis Intercomparison that is presented here. Eleven detection algorithms submitted hourly tags--binary fields indicating the presence or absence of atmospheric rivers--of detected atmospheric rivers in the Modern Era Retrospective Analysis for Research and Applications, version 2 (MERRA-2) and European Centre for Medium-Range Weather Forecasts' Reanalysis Version 5 (ERA5) as well as six-hourly tags in the Japanese 55-year Reanalysis (JRA-55). Due to a higher climatological mean for integrated water vapor transport in MERRA-2, atmospheric rivers were detected more frequently relative to the other two reanalyses, particularly in algorithms that use a fixed threshold for water vapor transport. The finer horizontal resolution of ERA5 resulted in narrower atmospheric rivers and an ability to detect atmospheric rivers along resolved coastlines. We found that the fraction of hemispheric area covered by ARs varies throughout the year in all three reanalyses, with different atmospheric river detection tools having different seasonal cycles.

54 ENVIRONMENTAL SCIENCES↗

Summertime Continental Shallow Cumulus Cloud Detection Using GOES‐16 Satellite and Ground‐Based Ceilometer at North Alabama

Abstract Accurate simulations of boundary layer cloud processes remain challenging in Earth system modeling. Observations are essential to evaluate and improve models of such processes. This study introduces a comprehensive validation framework for a satellite‐based detection algorithm of continental shallow cumulus (ShCu) clouds during the daytime, which was initially developed using ground‐based observations of stereo cameras at the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains site (J. Tian et al., 2021, https://doi.org/10.3390/rs13122309 , 2022, https://doi.org/10.1029/2021gl097070 ). To validate this algorithm, the framework employs ground‐based ceilometer measurements from North Alabama (NA) where ShCu populations are prevalent. This study first generates clear‐sky surface reflectance maps at NA and identifies ShCu pixels with a detection threshold using Geostationary Operational Environmental Satellite (GOES) reflectance data. The obtained cloud fractions (CFs) are then compared against CFs from a ground‐based ceilometer, considering factors such as observed area differences, satellite parallax issue, and systematic biases. We found that with a detection threshold (∆R) of 0.05, the ShCu detection algorithm is effective for NA, enabling the reproduction of hourly ShCu CFs using GOES. Our framework is straightforward and easily repeatable to evaluate the effectiveness of a ∆R threshold for detecting ShCu clouds in various geographic regions where ceilometers are deployed. This satellite detection of ShCu provides a crucial regional context for ground‐based measurements, facilitating the tracking of convection initiation and its coupling with land surface conditions. Integrating localized ground‐based and regional satellite data will enhance our ability to conduct thorough studies of cloud morphology and land‐atmosphere interactions in North Alabama.

54 ENVIRONMENTAL SCIENCES↗

PECAN: library-free peptide detection for data-independent acquisition tandem mass spectrometry data

Data-independent acquisition (DIA) is an emerging mass spectrometry (MS)-based technique for unbiased and reproducible measurement of protein mixtures. DIA tandem mass spectrometry spectra are often highly multiplexed, containing product ions from multiple cofragmenting precursors. Detecting peptides directly from DIA data is therefore challenging; most DIA data analyses require spectral libraries. Here we present PECECAN (http://pecan.maccosslab.org), a library-free, peptide-centric tool that robustly and accurately detects peptides directly from DIA data. PECECAN reports evidence of detection based on product ion scoring, which enables detection of low-abundance analytes with poor precursor ion signal. We demonstrate the chromatographic peak picking accuracy and peptide detection capability of PECECAN, and we further validate its detection with data-dependent acquisition and targeted analyses. Lastly, we used PECECAN to build a plasma proteome library from DIA data and to query known sequence variants.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗