Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detect and Avoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Electrooptic modulation methods for high sensitivity tunable diode laser spectroscopy

A CdTe phase modulator and low power RF sources have been used with Pb-salt tunable diode lasers operating near 8 microns to generate optical sidebands for high sensitivity absorption spectroscopy. Sweep averaged, first-derivative sample spectra of CH4 were acquired by wideband phase sensitive detection of the electrooptically (EO) generated carrier-sideband beat signal. EO generated beat signals were also used to frequency lock the TDL to spectral lines. This eliminates low frequency diode jitter, and avoids the excess laser linewidth broadening that accompanies TDL current modulation frequency locking methods.

Glenar, David A.↗

Aircraft Wake Vortex Measurements at Denver International Airport

Airport capacity is constrained, in part, by spacing requirements associated with the wake vortex hazard. NASA's Wake Vortex Avoidance Project has a goal to establish the feasibility of reducing this spacing while maintaining safety. Passive acoustic phased array sensors, if shown to have operational potential, may aid in this effort by detecting and tracking the vortices. During August/September 2003, NASA and the USDOT sponsored a wake acoustics test at the Denver International Airport. The central instrument of the test was a large microphone phased array. This paper describes the test in general terms and gives an overview of the array hardware. It outlines one of the analysis techniques that is being applied to the data and gives sample results. The technique is able to clearly resolve the wake vortices of landing aircraft and measure their separation, height, and sinking rate. These observations permit an indirect estimate of the vortex circulation. The array also provides visualization of the vortex evolution, including the Crow instability.

Dougherty, Robert P.↗

Radiological Diagnosis and Management of Epistaxis

The majority of episodes of spontaneous posterior epistaxis treated with embolisation are idiopathic in nature. The angiographic findings are typically normal. Specific angiographic signs are rare and may include the following: a tumour blush, telangiectasia, aneurysm, and/or extravasation. Selective internal carotid artery (ICA) angiography may show rare causes of epistaxis, such as traumatic or mycotic aneurysms, which require different treatment approaches. Complete bilateral selective external and internal carotid angiograms are essential to evaluation. The images should be analysed for detection of central retinal blush in the external carotid artery (ECA) and anastomoses between the branches of the ECA and ICA. Monocular blindness and stroke are two of the most severe complications. Embolisation aims to decrease flow to the bleeding nasal mucosa while avoiding necrosis of the nasal skin and palate mucosa. Embolisation is routinely performed with a microcatheter positioned in the internal maxillary artery distal to the origin of the meningeal arteries. A guiding catheter should be placed in the proximal portion of the ECA to avoid vasospasm. Embolisation with microparticles is halted when the peripheral branches of the sphenopalatine artery are occluded. The use of coils is not recommended because recurrent epistaxis may occur due to proximal embolization; moreover, the option of repeat distal embolisation is lost. The success rate of embolisation therapy (accounting for late recurrence of bleeding) varies between 71 and 94 %. Results from endoscopic surgery are quite comparable. When epistaxis is refractory to nasal packing or endoscopic surgery, embolisation is the treatment of choice in some centres.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thick branes in extra dimensions and suppressed dark couplings

The nature of dark matter (DM) and how it may interact with the various fields of the Standard Model (SM) remains a mystery. In this paper we show that the interaction between new light dark matter mediators and the SM particles can be naturally suppressed if one employs a single, flat extra dimension (ED). In this setup, the SM fields are localized in a finite width ‘fat’ brane, similar to models of Universal Extra Dimensions (UED), while DM, in turn, is confined to a thin brane at the opposite end of the ED interval. Including brane localized kinetic terms on the fat brane for the mediator fields, the resulting coupling between the SM and these light mediators can be several orders of magnitude smaller than the corresponding ones between the mediators and DM which we assume to be a typical gauge coupling. We investigate the implications of this scenario for both vector (i.e, dark photon, DP) and scalar mediator fields in the 5-D bulk. In this setup kinetic mixing, which is usually employed to suppress light mediator couplings, is not required. Here we assume that the SM particles couple to the DP via their B - L charges while the DP couples to the DM via a dark charge. Both the vector DP couplings and the corresponding Higgs portal couplings with the SM are shown to be natural small in magnitude with a size dependent on ratio of the 5-D compactification radius, R -1 ~ 0.1-1 GeV, and the SM brane thickness, L -1 ~ 2-10 TeV, a range chosen to avoid LHC and other experimental constraints. In this framework one can obtain the observed value of the DM relic abundance for a wide range of parameter choices, while the constrains due to direct DM detection and the invisible width of the Higgs do not impose significant challenges to the model. Finally, this mechanism can lead to distinct signatures in both present and upcoming experiments as it combines some common features of UED and DP models in a single ED setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nitrogen diffusion in silicate minerals, with implications for nitrogen transport and cycling in the lithosphere

Diffusion laws for nitrogen in orthoclase, quartz, olivine and clinopyroxene were determined using a combination of experimental strategies that included: in-diffusion from C-H-O-N vapor; in-diffusion from molten NH 4 Cl; and ion implantation followed by heating to mobilize N. Most experiments were conducted at pressures near 1 bar, but seven experiments were also run in a piston-cylinder device at P total = 1 GPa. The C-H-O-N-source experiments were “wet” (H 2 O present); those on ion-implanted samples were dry. All N sources were highly enriched in 15 N to avoid spurious 14 N signals resulting from surface contamination. Use of 15 N also enabled depth profiling by nuclear reaction analysis (NRA) using the 15 N(p,αγ) 12 C reaction, which has a detection limit of ~10 ppm. Nitrogen profiles in three samples were characterized by both NRA and SIMS, with similar results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Innovative biomagnetic imaging sensors for breast cancer: A model-based study

Breast cancer is a serious potential health problem for all women and is the second leading cause of cancer deaths in the United States. The current screening procedures and imaging techniques, including x-ray mammography, clinical biopsy, ultrasound imaging, and magnetic resonance imaging, provide only 73% accuracy in detecting breast cancer. This gives the impetus to explore alternate techniques for imaging the breast and detecting early stage tumors. Among the complementary methods, the noninvasive biomagnetic breast imaging is attractive and promising, because both ionizing radiation and breast compressions that the prevalent x-ray mammography suffers from are avoided. It furthermore offers very high contrast because of the significant electromagnetic properties' differences between the cancerous, benign, and normal breast tissues. In this paper, a hybrid and accurate modeling tool for biomagnetic breast imaging is developed, which couples the electromagnetic and ultrasonic energies, and initial validations between the model predication and experimental findings are conducted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inhibitive formation of nanocavities by introduction of Si atoms in Ge nanocrystals produced by ion implantation

Germanium nanocrystals (Ge-nc) were successfully synthesized by co-implantation of Si and Ge ions into a SiO{sub 2} film thermally grown on (100) Si substrate and fused silica (pure SiO{sub 2}), respectively, followed by subsequent annealing at 1150 °C for 1 h. Transmission electron microscopy (TEM) examinations show that nanocavities only exist in the fused silica sample but not in the SiO{sub 2} film on a Si substrate. From the analysis of the high-resolution TEM images and electron energy-loss spectroscopy spectra, it is revealed that the absence of nanocavities in the SiO{sub 2} film/Si substrate is attributed to the presence of Si atoms inside the formed Ge-nc. Because the energy of Si-Ge bonds (301 kJ·mol{sup −1}) are greater than that of Ge-Ge bonds (264 kJ·mol{sup −1}), the introduction of the Si-Ge bonds inside the Ge-nc can inhibit the diffusion of Ge from the Ge-nc during the annealing process. However, for the fused silica sample, no crystalline Si-Ge bonds are detected within the Ge-nc, where strong Ge outdiffusion effects produce a great number of nanocavities. Our results can shed light on the formation mechanism of nanocavities and provide a good way to avoid nanocavities during the process of ion implantation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sorting for secreted molecule production using a biosensor-in-microdroplet approach

Significance The design–build–test cycle of metabolic engineering is swiftly becoming test limited owing to advances in DNA synthesis and library design. At the same time, improving extracellular production requires high-throughput studies to detect extracellular (not intracellular) content. Traditional approaches that utilize chromatography-based analysis or plate-based fluorescence assays are relatively throughput limited and require a high degree of liquid handling. These limitations are avoided here by creating a generalizable approach for small molecule production screening. Namely, this paradigm combines “off-the-shelf” biosensors with large library screening from producing cells in a cell-type agnostic manner.

Bowman, Emily K.↗

Optimization of Pressurized Oxy-Combustion with Flameless Reactor

Pressurized OxyECombustion is one of the most promising technologies for utility-scale power generation plants. Benefits include the ability to burn low rank coal and capture CO 2 . By increasing the flue gas pressure during this process, greater efficiencies are derived from increased quantity and quality of thermal energy recovery. UPA with modeling support from MIT and testing and data verification by Georgia Tech’s Research Center designed and built a 100 kW system capable of demonstrating pressurized oxyEcombustion using a flameless combustor. Wyoming PRB coal was run at 15 and 32 bar. Additional tests were not completed but sampled data demonstrated the viability of the technology over a broader range of operating pressures, Modeling results illustrated a flat efficiency curve over 20 bar, with optimum efficiency achieved at 29 bar. This resulted in a 33% (HHV) efficiency, a 5 points increase in efficiency versus atmospheric oxy-combustion, and a competitive cost of electricity plus greater CO 2 avoidance costs then prior study’s presented. UPA’s operation of the bench-scale system provided evidence that key performance targets were achieved: flue gas sampled at the combustor outlet had non-detectable residual fly ashes, and low levels of SO3 and heavy-metal. These results correspond to prior pressurized oxy-combustion testing completed by IteaEEnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Crossflow vorticity sensor

A crossflow vorticity sensor for the detection of crossflow vorticity characteristics is described. The sensor is comprised of crossflow sensors which are noninvasively adhered to a swept wing laminar surface either singularly, in multi-element strips, in polar patterns, or in orthogonal patterns. These crossflow sensors are comprised of hot-film sensor elements which operate as a constant temperature anemometer circuit to detect heat transfer rate changes. Accordingly, crossflow vorticity characteristics are determined via cross-correlation. In addition, the crossflow sensors have a thickness which does not exceed a maximum value h in order to avoid contamination of downstream crossflow sensors.

Holmes, Bruce J.↗

NASA Conjunction Assessment Risk Analysis (CARA) Ground Systems, Software and Operations Infrastructure Cloud Implementation

The growing number of large-scale constellations and the improvements made in the tracking and detection of resident space objects have contributed to the increase of satellite conjunction events. As a result of the increase of objects in Earth orbit, the timeline for risk analysis computations for satellite collision avoidance is more urgent when conjunctions occur. It is imperative NASA maintains a space environment safety functionality for the agency that allows CARA remote access to the ground system while maintaining redundancy. CARA’s On-premises (On-prem) ground system would no longer be able to meet these access and redundancy requirements, hence the investigation and eventual implementation of a Cloud-based ground station infrastructure as a viable solution. This paper will provide an overview of the principal parts of the Conjunction Assessment (CA) risk analysis process used at CARA, summarize the key drivers towards the Cloud solution, and share key lessons learned that are significant for any operational entity considering a cloud solution for real-time satellite operations to ensure a sustainable space traffic environment for all.

Sustainability↗

Digital Twinning and Predictive Modeling of Traffic for Safe, Efficient, and Reliable Intersections

Over the last decade, the advances in connected and autonomous vehicles (CAVs) have far surpassed the technological realm of transportation infrastructure. There is a growing need to have a technologically commensurate transportation infrastructure to enable safe and reliable movement of goods and people. The recent creation of Advanced Research Projects Agency - Infrastructure (ARPA-I) through the Infrastructure Investment and Jobs Act by the U.S. Department of Transportation (USDOT) has further amplified the need to revolutionize the transportation infrastructure system in the US. This need is perhaps felt most at traffic intersections, as more than 50 percent of the combined total of fatal and injury crashes occur at or near intersections. The proposed concept of Infrastructure Perception and Control (IPC) is aimed at bridging this technological gap by building a real-time digital twin of traffic by fusing detections from sensors installed at the intersection. This digital twin can then empower a wide variety of applications such as smart traffic signals or infrastructure-to-everything (I2X) communications. Smart signaling can help avoid crashes through early-prediction, while I2X can augment the CAV sensors under uncertain driving conditions and provide connected vehicles (CVs) with traffic information they can use to optimize their travel.

connected vehicles↗

Tas2r125 functions as the main receptor for detecting bitterness of tea catechins in the oral cavity of mice

Highlights: • We identified mouse 5 bitter taste receptors (Tas2rs) which respond to tea catechin. • Among these receptors, Tas2r125 showed the strongest response to catechins. • The response profiles of Tas2r125 were consistent with the behavior profiles. • Tas2r125 expression was not observed in the tested tissues except the taste papillae. • Tas2r125 plays as the catechin receptor in the oral cavity. We attempted to identify mouse bitter taste receptors, Tas2rs, that respond to tea catechins. Among representative tea catechins, avoidance behavior of mice to (−)–epicatechin gallate (ECg) was the strongest, followed by (−)–epigallocatechin gallate (EGCg). Therefore, we measured ECg response using Tas2rs-expressing cells. Among the 35 members of Tas2r family, Tas2r108, 110, 113, 125, and 144 responded to ECg. Among these receptors, Tas2r113 and 125 also responded to EGCg. Because the response profiles of Tas2r125 were consistent with the results of the behavior assays, it was considered that Tas2r125 functions as the main receptor for detecting bitterness of tea catechins in the oral cavity. To determine the involvement of Tas2rs in the physiological action of catechins, mRNA expression of 5 Tas2rs was investigated in various tissues. Because mRNA expression of Tas2r108 was observed in some tissues including the gastrointestinal tract, it may be envisaged that Tas2r108 plays a part in exerting the physiological action of ECg. Tas2r125 expression was not observed in any of the tested tissues except the circumvallate papillae. Therefore, Tas2r125 was considered to mainly function in the events of catechin reception in the oral cavity.

60 APPLIED LIFE SCIENCES↗

Occultation detection of a Neptune ring segment

A stellar occulation event of Neptune revealed a ring segment that was previously undetected. It appears that the object is not a complete ring, but rather a localized swarm of particles which follows a ring orbit over a limited range of longitudes. To avoid confusion with the standard use of the word ring it is suggested that the feature be called an arc. The distance of the arc zone is not precisely known because so far there has been no confirmed occultation by both an arc and the planet.

Hubbard, W. B.↗

Noise suppression for MHD characterization with electron cyclotron emission imaging 1D technique

Significant noise suppression for magnetohydrodynamics (MHD) mode characterization in the spatial and spectral domain is achieved by processing two-dimensional (2D) electron cyclotron emission imaging (ECEI) data with a one-dimensional (1D) ECEI technique using a short time window ($1\;{\text{ms}}$). The technique is applied to detect toroidal Alfven eigenmodes (TAEs) in the temporal spectrum and fit their radial envelope using the data from the DIII-D tokamak W-band 2D ECEI system. Using the data length (time window) of only 1 ${\text{ms}}$, the 1D ECEI can clearly detect the TAEs (~100 ${\text{kHz}}$) on the spectrum, while similar spectrum quality requires ~10 ${\text{ms}}$ data length with the cross power spectrum between two midplane ECEI channels. The 1D ECEI technique also effectively avoids biased fitting when resolving the fine structure of the TAE's radial envelope. The radially spatial resolution of 1D ECEI is constrained by the finite ECE radiation volume of the ECEI receiver. Here, with forward radiation modeling, we find the DIII-D ECEI system can sensitively measure the even parity MHD activities, for which the mode width is >15 mm, and tearing modes (odd parity MHD activities), for which the island full width is >30 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MagMicro with Ultra-High Energy Resolution (Progress Report Q4 FY18)

We are performing extensive simulations of the MMC detector response to optimize their energy resolution, detection efficiency and count rate based on the data we took in FY17/18. The optimized layout separates the MMC detector chip from the SQUID preamplifier chips coupled to the MMCs through Al wire bonds to avoid heating the MMC with the power dissipation of the SQUID. The goal is to design MMC gamma detectors with a limiting energy resolution below ~25 eV FWHM up to >100 keV and ~1 ms decay times for maximum count rates of several tens of counts/s per pixel. The simulations, which were done at the Supercomputing Center of the University of New Mexico, are taking significantly longer than expected. The difficulty is that the device performance depends intricately on the design parameters, and each simulation is quite involved because it needs to cover the frequency range well into the GHz range to account for the ac Josephson effect. This is delaying the start of the detector array fabrication, and we have not been able to complete the fabrication and the testing of the 32-pixel MMC arrays by September 30. We have therefore requested a no-cost extension of the project to March 31, 2019.

42 ENGINEERING↗

Node Synchronization for the Viterbi Decoder

At very low signal to noise ratios such as those that Voyager 2 will encounter at Uranus, the performance of the Reed-Solomon/Viterbi concatenated coding system could be seriously degraded by loss of node synchronization by the Viterbi decoder. This problem is described and now it can be almost completely avoided with a simple outboard hardware ""node synchronizer''. This device makes statistical decisions about node sync based on the hard quantized undecoded data stream. In a worst case Voyager-like environment, our method will detect and correct a true loss of node sync (thought to be a very rate event) within several hundred bits; many of these false alarms for our technique is on the order several years.

Lorden, G.↗