Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

High spatial resolution imaging of biological tissues using nanospray desorption electrospray ionization mass spectrometry

Mass spectrometry imaging (MSI) enables label-free spatial mapping of hundreds of biomolecules in tissue sections. This capability provides valuable information on tissue heterogeneity that is difficult to obtain using population-averaged assays. Despite substantial developments in both instrumentation and methodology, MSI of tissue samples at single-cell resolution remains challenging. In our research, we describe a protocol for robust imaging of tissue sections with a high (better than 10-μm) spatial resolution using nanospray desorption electrospray ionization (nano-DESI) mass spectrometry, an ambient ionization technique that does not require sample pretreatment before analysis. In this protocol, mouse uterine tissue is used as a model system to illustrate both the workflow and data obtained in these experiments. We provide a detailed description of the nano-DESI MSI platform, fabrication of the nano-DESI and shear force probes, shear force microscopy experiments, spectral acquisition, and data processing. A properly trained researcher (e.g., technician, graduate student, or postdoc) can complete all the steps from probe fabrication to data acquisition and processing within a single day. We further describe a new strategy for acquiring both positive- and negative-mode imaging data in the same experiment. This is achieved by alternating between positive and negative data acquisition modes during consecutive line scans. Using our imaging approach, hundreds of high-quality ion images were obtained from a single uterine section. This protocol enables sensitive and quantitative imaging of lipids and metabolites in heterogeneous tissue sections with high spatial resolution, which is critical to understanding biochemical processes occurring in biological tissues.

59 BASIC BIOLOGICAL SCIENCES↗

Structure of human adenovirus

A detailed structural analysis of the entire human adenovirus capsid has been stymied by the complexity and size of this 150 MDa macromolecular complex. Over the past 10 years, the steady improvements in viral genome manipulation concomitant with advances in crystallographic techniques and data processing software has allowed structure determination of this virus by X-ray diffraction at 3.5 {angstrom} resolution. The virus structure revealed the location, folds, and interactions of major and minor (cement proteins) on the inner and outer capsid surface. This new structural information sheds further light on the process of adenovirus capsid assembly and virus-host cell interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Proceedings of the 2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

These proceedings contain papers prepared for the Monitoring Research Review 2010: Ground-Based Nuclear Explosion Monitoring Technologies, held 21-23 September, 2010 in Orlando, Florida,. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, National Science Foundation (NSF), Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), and other invited sponsors. The scientific objectives of the research are to improve the United States capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Minimum critical masses and their uncertainties for several fissile nuclides and reflectors - 14296

A systematic effort was undertaken to reevaluate the minimum critical mass for several fissile nuclides and reflectors. This was done using MCNP6 in combination with several modern nuclear data libraries, viz. ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1.1. This combination was benchmarked extensively against criticality safety benchmarks. The procedure to extract the minimum critical mass from the MCNP6 calculations was carefully implemented, so that it would have a negligible impact on the accuracy of the end results. All parts of the calculation, i.e. nuclear data processing, MCNP6 models, and post-processing, were applied consistently for all cases, involving varying fissile nuclides and reflectors. Results for the minimum critical mass were generated for {sup 233,235}U, {sup 236,239,241}Pu, {sup 242m}Am, {sup 243,245,247}Cm, and {sup 249,251}Cf, for the case of water moderation and water reflection. For {sup 235}U, the minimum critical mass was also calculated for cases with other reflectors, such as beryllium, heavy water, graphite, lead, and concrete. The results for the water reflection cases are in good agreement with most of the literature values, but for the cases with reflectors such as graphite, lead, or concrete, there are sizable differences. The accuracy of the results was assessed in two ways. First, a comparison was made with criticality safety benchmark results, by selecting benchmarks that resemble the minimum mass systems the most. It was clear that for {sup 233,235}U and {sup 239}Pu with water reflection, the differences in minimum critical masses between the libraries are consistent with the differences obtained for benchmark cases. The difference between the benchmark calculations and the benchmark values is then an indication of the accuracy with which one can simulate comparable systems. Secondly, sensitivity runs were performed with the new MCNP6 sensitivity option, based on ENDF/B-VII.1 nuclear data. For each fissile nuclide, the sensitivity of k{sub eff} to cross sections such as capture, fission, elastic, inelastic was calculated for the minimum critical mass case. The same was done for the {sup 1}H and {sup 16}O cross sections in the moderator and reflector. The uncertainty in k{sub eff} was calculated by combining the sensitivity profiles with the appropriate ENDF/B-VII.1 covariance matrix, using the SUSD code. As a final step, the uncertainty in k{sub eff} can be translated to an uncertainty in the minimum critical mass. (author)

42 ENGINEERING↗

Laser control of free-carrier density in solids through field-enhanced multiphonon tunneling recombination

Enhancement of multiphonon tunneling recombination of free carriers in strong laser fields is shown to offer a mechanism whereby ultrafast carrier-density dynamics in a semiconductor can be controlled by properly shaped laser pulses. This regime of laser-solid interaction enables an ultrafast switching of optical and electric properties of semiconductor materials, suggesting new strategies for laser micromachining and nanomachining, optical data processing, and ultrafast plasmonics.

36 MATERIALS SCIENCE↗

Microdisplays in spatial light modulators

The characteristics of modern microdisplays based on liquid crystals and electromechanical micromirrors are considered. These displays, being spatial light modulators, can rapidly generate large optical data arrays to be recorded as holograms and used for data processing. The potential of microdisplays for visualising digital holograms in real time is estimated. (invited paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proceedings of the 2011 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

These proceedings contain papers prepared for the Monitoring Research Review 2011: Ground-Based Nuclear Explosion Monitoring Technologies, held 13-15 September, 2011 in Tucson, Arizona. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Defense Threat Reduction Agency (DTRA), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), National Science Foundation (NSF), and other invited sponsors. The scientific objectives of the research are to improve the United States' capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Design of a spin-wave majority gate employing mode selection

The design of a microstructured, fully functional spin-wave majority gate is presented and studied using micromagnetic simulations. This all-magnon logic gate consists of three-input waveguides, a spin-wave combiner, and an output waveguide. In order to ensure the functionality of the device, the output waveguide is designed to perform spin-wave mode selection. We demonstrate that the gate evaluates the majority of the input signals coded into the spin-wave phase. Moreover, the all-magnon data processing device is used to perform logic AND-, OR-, NAND-, and NOR- operations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utah FORGE: Optimization of a Plug-and-Perf Stimulation (Fervo Energy)

Information around the plug-and-perf treatment design at Utah FORGE by Fervo Energy. Objective and Purpose: - Develop a multistage hydraulic stimulation approach designed specifically to target the top three factors that control the technical and commercial viability of an EGS system: i) Achieving sufficient injectivity to support high cross-well flow rates ii) Distributing flow evenly across the wellbore and reservoir to maximize heat mining efficiency, ensure sustained heat transfer, and mitigate thermal breakthrough iii) Overcoming the effects of stress heterogeneity, stress shadowing, and variations in natural fracture properties during the stimulation treatment, leading to a more predictable stimulated reservoir volume and offset well placement - The following activities will be performed: i) Design, plan, and execute a multistage plug-and-perf stimulation treatment at a Fervo site with data acquisition and well testing activities aimed at addressing key technical aspects of the issues above ii) Perform data processing and interpretation of field results to translate the results form the Fervo site to a site-specific design at the Utah FORGE site iii) Design, plan, and execute a multistage plug-and-perf stimulation treatment design at the Utah FORGE site Methods and Approach: - Design a detailed data acquisition plan to maximize learning around: i) DFIT testing ii) Petrophysical logging, image logging iii) Permanent DAS/DTS fiber optic monitoring iv) Deep borehole microseismic monitoring v) Shallow borehole induced seismicity monitoring vi) Injection/production testing (RTA analysis, tracer testing) vii) Integrated numerical modeling and production forecasting

15 GEOTHERMAL ENERGY↗

MODIS Airborne simulator (MAS) Final Report for CLASIC

The MAS was flown aboard the NASA ER-2 for the CLASIC field experiment, and for all data collected, provided calibrated and geolocated (Level-1B) radiance data for it’s 50 spectral bands (ranging in wavelength for 0.47 to 14.3 µm). From the Level-1B data, as directed in the Statement of Work, higher order (Level-2) data products were derived. The Level-2 products include: a) cloud optical thickness, b) cloud effective radius, c) cloud top height (temperature), d) cloud fraction, e) cloud phase products. Preliminary Level-1B and Level-2 products were provided during the field experiment (typically within one or two days of data collection). Final version data products were made available in December 2008 following considerable calibration analysis. Data collection, data processing (to Level-2), and discussion of the calibration work are summarized below.

54 ENVIRONMENTAL SCIENCES↗

Note: Statistical errors estimation for Thomson scattering diagnostics

A practical way of estimating statistical errors of a Thomson scattering diagnostic measuring plasma electron temperature and density is described. Analytically derived expressions are successfully tested with Monte Carlo simulations and implemented in an automatic data processing code of the JET LIDAR diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

α-z-Rényi relative entropies

We consider a two-parameter family of Rényi relative entropies D{sub α,z}(ρ ∥ σ) that are quantum generalisations of the classical Rényi divergence D{sub α}(p ∥ q). This family includes many known relative entropies (or divergences) such as the quantum relative entropy, the recently defined quantum Rényi divergences, as well as the quantum Rényi relative entropies. All its members satisfy the quantum generalizations of Rényi’s axioms for a divergence. We consider the range of the parameters α, z for which the data-processing inequality holds. We also investigate a variety of limiting cases for the two parameters, obtaining explicit formulas for each one of them.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE SWIFT/BAT HARD X-RAY TRANSIENT MONITOR

The Swift/Burst Alert Telescope (BAT) hard X-ray transient monitor provides near real-time coverage of the X-ray sky in the energy range 15-50 keV. The BAT observes 88% of the sky each day with a detection sensitivity of 5.3 mCrab for a full-day observation and a time resolution as fine as 64 s. The three main purposes of the monitor are (1) the discovery of new transient X-ray sources, (2) the detection of outbursts or other changes in the flux of known X-ray sources, and (3) the generation of light curves of more than 900 sources spanning over eight years. The primary interface for the BAT transient monitor is a public Web site. Between 2005 February 12 and 2013 April 30, 245 sources have been detected in the monitor, 146 of them persistent and 99 detected only in outburst. Among these sources, 17 were previously unknown and were discovered in the transient monitor. In this paper, we discuss the methodology and the data processing and filtering for the BAT transient monitor and review its sensitivity and exposure. We provide a summary of the source detections and classify them according to the variability of their light curves. Finally, we review all new BAT monitor discoveries. For the new sources that are previously unpublished, we present basic data analysis and interpretations.

79 ASTRONOMY AND ASTROPHYSICS↗

A versatile scalable PET processing system

Positron Emission Tomography (PET) historically has major clinical and preclinical applications in cancerous oncology, neurology, and cardiovascular diseases. Recently, in a new direction, an application specific PET system is being developed at Thomas Jefferson National Accelerator Facility (Jefferson Lab) in collaboration with Duke University, University of Maryland at Baltimore (UMAB), and West Virginia University (WVU) targeted for plant eco-physiology research. The new plant imaging PET system is versatile and scalable such that it could adapt to several plant imaging needs - imaging many important plant organs including leaves, roots, and stems. The mechanical arrangement of the detectors is designed to accommodate the unpredictable and random distribution in space of the plant organs without requiring the plant be disturbed. Prototyping such a system requires a new data acquisition system (DAQ) and data processing system which are adaptable to the requirements of these unique and versatile detectors.

43 PARTICLE ACCELERATORS↗

Remote access and automation of SPring-8 MX beamlines

At SPring-8 MX beamlines, a remote access system has been developed and started user operation in 2010. The system has been developed based on an automated data collection and data management architecture utilized for the confirmed scheme of SPring-8 mail-in data collection. Currently, further improvement to the remote access and automation which covers data processing and analysis are being developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TiN Nanoporous Electrode Covered by Single Cell as Bio-Electronic Sensor of Radiation Hazard

Here we demonstrate a simple label-free bio-electronic radiation (ultra-violet) hazard detector based on non-destructive electrical impedance spectroscopy technique with a single living cell as a sensing element. Radiation results in wrong cell’s functioning and, as corollary, cell’s membrane distortion. The latter results in impedance shift for the electrode covered by the cell. The additional sensitivity of impedance shift is achieved by the simultaneous usage of the TiN porous electrodes and adaptive filtering for impedance data processing. The main advantage of the proposed sensor with respect to purely physical and/or chemical sensors is high selectivity: it a priory reacts only on the dangerous for living beings radiation.

36 MATERIALS SCIENCE↗

WHOLESCALE: Seismic Survey Metadata from San Emidio Nevada 2021

This is a collection of metadata from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 deg N, 119.409019 deg W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The raw and processed data are in an associated GDR submission, linked below. The metadata here includes files containing experiment details, station locations, seismic data logger specifications, instrumentation specifications, and descriptions of data. Also included are data and metadata from a 2016 seismic survey at the same site.

15 GEOTHERMAL ENERGY↗

Measurement of prompt neutron generation time at the VIR-2M pulsed nuclear reactor

The prompt neutron generation time is measured in the core of the VIR-2M research nuclear reactor. The measurements are performed using the Babala method while the reactor is in the subcritical state. The VIR-2M reactor and the relevant experimental equipment are briefly described, and the experimental procedure and data processing technique are presented. It is shown that the prompt neutron generation time with empty experimental channels is 35 ± 1 μs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗