At least 1,009 records · Page 56

Facile synthesis of CuSe nanoparticles and high-quality single-crystal two-dimensional hexagonal nanoplatelets with tunable near-infrared optical absorption

A rapid injection approach is used to synthesize the copper selenide nanoparticles and two-dimensional single crystal nanoplates. This technique excludes the use of toxic or expensive materials, increasing the availability of two-dimensional binary chalcogenide semiconductors. The structure of the nanocrystals has been studied and the possible formation mechanism of the nanoplates has been proposed. The optical absorption showed that the nanoplates demonstrated wide and tuneable absorption band in the visible and near infrared region. These nanoplates could be interesting for converting solar energy and for nanophotonic devices operating in the near infrared. - Graphical abstract: TEM images of the copper selenides nanoparticles and nanoplates synthesized at 180 °C for 0 min, 10 min, 60 min. And the growth mechanism of the copper selenide nanoplates via the “oriented attachment”. Display Omitted - Highlights: • CuSe nanoparticles and nanoplates are synthesized by a rapid injection approach. • CuSe band gap can be widely tuned simply by modifying the synthesized time. • Al{sup 3+} ions have a significant impact on the growth rate of the nanoplates. • Growth mechanism of the CuSe nanoplates is based on the “oriented attachment”.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications

Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biofeedback With Implanted Blood-Pressure Device

Additional uses found for equipment described in "Implanted Blood-Pressure-Measuring Device" (GSC-13042). Implanted with device electronic circuitry that measures, interprets, and transmits data via inductive link through patient's skin to external receiver. Receiver includes audible alarm generator activated when patient's blood pressure exceeds predetermined threshold. Also included in receiver a blood-pressure display, recorder, or both, for use by patient or physician.

Rischell, Robert E.↗

Technical aspects of a demonstration tape for three-dimensional sound displays

This document was developed to accompany an audio cassette that demonstrates work in three-dimensional auditory displays, developed at the Ames Research Center Aerospace Human Factors Division. It provides a text version of the audio material, and covers the theoretical and technical issues of spatial auditory displays in greater depth than on the cassette. The technical procedures used in the production of the audio demonstration are documented, including the methods for simulating rotorcraft radio communication, synthesizing auditory icons, and using the Convolvotron, a real-time spatialization device.

Begault, Durand R.↗

NASA Solar Array Demonstrates Commercial Potential

A state-of-the-art solar-panel array demonstration site at NASA's Dryden Flight Research Center provides a unique opportunity for studying the latest in high-efficiency solar photovoltaic cells. This five-kilowatt solar-array site (see Figure 1) is a technology-transfer and commercialization success for NASA. Among the solar cells at this site are cells of a type that was developed in Dryden Flight Research Center s Environmental Research Aircraft and Sensor Technology (ERAST) program for use in NASA s Helios solar-powered airplane. This cell type, now denoted as A-300, has since been transferred to SunPower Corporation of Sunnyvale, California, enabling mass production of the cells for the commercial market. High efficiency separates these advanced cells from typical previously commercially available solar cells: Whereas typical previously commercially available cells are 12 to 15 percent efficient at converting sunlight to electricity, these advanced cells exhibit efficiencies approaching 23 percent. The increase in efficiency is due largely to the routing of electrical connections behind the cells (see Figure 2). This approach to increasing efficiency originated as a solution to the problem of maximizing the degree of utilization of the limited space available atop the wing of the Helios airplane. In retrospect, the solar cells in use at this site could be used on Helios, but the best cells otherwise commercially available could not be so used, because of their lower efficiencies. Historically, solar cells have been fabricated by use of methods that are common in the semiconductor industry. One of these methods includes the use of photolithography to define the rear electrical-contact features - diffusions, contact openings, and fingers. SunPower uses these methods to produce the advanced cells. To reduce fabrication costs, SunPower continues to explore new methods to define the rear electrical-contact features. The equipment at the demonstration site includes two fixed-angle solar arrays and one single-axis Sun-tracking array. One of the fixed arrays contains typical less-efficient commercial solar cells and is being used as a baseline for comparison of the other fixed array, which contains the advanced cells. The Sun-tracking array tilts to follow the Sun, using an advanced, real-time tracking device rather than customary pre-programmed mechanisms. Part of the purpose served by the demonstration is to enable determination of any potential advantage of a tracking array over a fixed array. The arrays are monitored remotely on a computer that displays pertinent information regarding the functioning of the arrays.

Creech, Gray↗

ISSLive!

The ISSLive! project is a JSC innovation award- winning, combined MOD/Education project to publish export control and PAO-approved ISS telemetry, and simplified and scrubbed crew timelines. The publication of this data will be real-time or near real time and will include links to the crew's social media feeds and existing streaming public video/audio feeds, via public-friendly website, mobile devices and tablet applications. Additionally, the project will offer interactive virtual 3D views of an ISS model based on real-time telemetry and a 3D virtual mission control center based on existing Front Room console positions in made for public displays. The ISSLive! project is MOD-managed and includes collaborations with subject-matter expertise from the ISS flight controllers regarding daily operations and planning, education program specialists from the JSC Office of Education, instructional designers, human computer interface experts, and software/hardware experts from MOD facility organization, and senior web designers. In support of the Agency s Strategic Goal #6 with respect to using the ISS National Laboratory for education activities, ISSLive! uses the Station itself as STEM education subject matter and provides data for STEM-based lessons plans using national standards. Specifically, ISSLive! supports and enables the National Laboratory Education (NLE) project to address the Agency s Strategic Goal #6. This goal mandates, sharing NASA with the public, educators, and students to provide opportunities to participate in our Mission, foster innovation .. ISSLive! satisfies the Agency s outcomes of Strategic Goal; that is, engages the public in NASA's missions by providing new pathways for participation (Outcome 6.3) and it informs, engages, and inspires the public by sharing NASA s missions, challenges, and results (Outcome 6.4). Additionally, ISSLive! enables MOD s support of JSC Outreach and NASA's Open Data and Open Government Initiatives. The audience for the ISSLive! website and its application(s) are: teachers, students, citizen scientists, and the general public who will be given new and interactive insights on how the ISS Operates.

Price, Jennifer B.↗

Enabling novel space and terrestrial applications using transducing materials at JPL

Transducing materials are being used in many aspects of our daily life serving as actuators, sensors, displays, communications and other components of commercial mechanisms. At JPL, such materials are being used to enable novel space and terrestrial applications. This effort involves mostly the use of piezoelectric, electroactive polymers (EAP), and shape memory alloys (SMA). The piezoelectric based devices and mechanisms that were developed include ultrasonic motors, piezopump, ultrasonic/sonic drilledcorer (USDC), and ferrosource. Further, the electroactive polymers were used to demonstrate a gripper, wiper, lifter and haptic interfaces. The research and develop tasks consists of analytical modeling, experimental corroboration, material characterization as well as devices and mechanisms design, construction and demonstration.

electroactive↗

Devices combining thin film inorganic LEDs with organic LEDs and fabrication thereof

Devices including organic and inorganic LEDs are provided. Techniques for fabricating the devices include fabricating an inorganic LED on a parent substrate and transferring the LED to a host substrate via a non-destructive ELO process. Scaling techniques are also provided, in which an elastomeric substrate is deformed to achieve a desired display size.

36 MATERIALS SCIENCE↗

Devices combining thin film inorganic LEDs with organic LEDs and fabrication thereof

Devices including organic and inorganic LEDs are provided. Techniques for fabricating the devices include fabricating an inorganic LED on a parent substrate and transferring the LED to a host substrate via a non-destructive ELO process. Scaling techniques are also provided, in which an elastomeric substrate is deformed to achieve a desired display size.

Forrest, Stephen R.↗

Significantly Enhanced Emission Stability of CsPbBr 3 Nanocrystals via Chemically Induced Fusion Growth for Optoelectronic Devices

Lead–halide perovskite nanocrystals (PNCs) have attracted much attention in recent years due to their outstanding optical properties. We report here a new chemical route for triggering postsynthetic growth of CsPbBr 3 PNCs at room temperature via intentional depletion of stabilizing ligands, resulting in an immediate fusion growth of the as-synthesized PNCs. Upon fusion, the CsPbBr 3 PNCs can grow from ca. 8 nm to ca. 60 nm in lateral dimensions in 48 h, reaching about 14 nm in thickness. More importantly, it was found that the fused PNCs have significantly enhanced optical properties. They showed an exceptionally higher stability to photodegradation. They also displayed sharper emission lines and a higher quantum yield, contrary to the fact that the nanocrystals are much larger. The much-improved optical properties are attributed to the Ruddlesden–Popper (RP) planar faults formed during the fusion process and observed using atomic resolution scanning transmission electron microscopy, which are predicted to result in quantum confinement based on density-functional theory calculations. The newly grown nanocrystals with RP defects are expected to significantly improve light emission properties of the PNCs and find applications in light-emitting diodes and other optoelectronic devices.

36 MATERIALS SCIENCE↗

Prospective Clinical Implementation of a Novel Magnetic Resonance Tracking Device for Real-Time Brachytherapy Catheter Positioning

Purpose: We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. Methods and Materials: Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. Results: Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. Conclusions: MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Display screen and method of manufacture therefor

A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. Compatible screen structures, along with methods for fabricating high resolution prescreens and methods and devices for maintaining the desired relationship between the prescreen and the diffusion screen are contemplated.

Dubin, Matthew B.↗

Pulsed response of a TWT

The consequence of frequency domain multiple access channelization in a satellite communications system is that the ground- and space-based components often are required to operate in a linear region to prevent the generation of distortion signals. Components of a time division multiple access (TDMA) satellite system, such as a traveling-wave tube (TWT), can operate in the highest output power state because the channelization technique is relatively insensitive to the distortions resulting from saturated operation. A 30 GHz TWT was tested to determine the suitability of such a device in a TDMA system. Testing was focused on the ability of the TWT's output signal to rise up to full power at the leading edge of TDMA bursts, simulated by a pulse train. A peak power meter was used to display and measure the pulsed signal waveform. Measurements on the TWT output pulse rise time indicate that the TWT lengthened the rise time by 10 to 20 ns. Imposing modulator turn on timing that precedes the data burst by the TWT rise time is a logical approach to coordination of the two subsystem specification.

May, Brian D.↗

Sensing And Force-Reflecting Exoskeleton

Sensing and force-reflecting exoskeleton (SAFiRE) provides control signals to robot hand and force feedback from robot hand to human operator. Operator makes robot hand touch objects gently and manipulates them finely without exerting excessive forces. Device attaches to operator's hand; comfortable and lightweight. Includes finger exoskeleton, cable mechanical transmission, two dc servomotors, partial thumb exoskeleton, harness, amplifier box, two computer circuit boards, and software. Transduces motion of index finger and thumb. Video monitor of associated computer displays image corresponding to motion.

Eberman, Brian↗

Noise in Josepson effect mixers and the RSJ model

Josephson effect mixers have previously been observed to display 'excess' noise both in experiments with point contacts and in numerical simulations using the resistively shunted junction (RSJ) model. This excess noise causes the mixer noise temperature to be a factor of typically 20-100 times the physical temperature of the device. Previously, this excess was ascribed to conversion from unwanted sidebands of the local oscillator and Josephson frequencies and their harmonics. Our numerical modeling of the RSJ equations has led to a new understanding of the excess noise, which is simply due to the intrinsic Josephson oscillations of the device. In addition, we have extended the modeling to include the previously ignored case of finite device capacitance (i.e. RSJ capacitance parameter beta(sub c) does not equal 0, which is more realistic for lithographically defined Josephson such as shunted tunnel junctions or SNS bridges. For some cases, this yields an improvement of a factor of two in noise temperature from the zero capacitance models. We will discuss the device parameters which optimize the mixer performance for frequencies approaching the characteristic frequency of the device, which is given by the Josephson frequency at the I(sub c)R(sub n) voltage (nu = 2eI(sub c)R(sub n)/h). These modeling results predict good conversion efficiency and a noise temperature within a factor of a few of the physical temperature. Experiments are in progress to determine the accuracy of this modeling using a waveguide mixer at 100 GHz with optimized, resistively shunted Nb tunnel junctions. If the modeling results are valid, they are particularly encouraging for mixers in the submillimeter regime, given the possibility of obtaining non-hysteretic Josephson devices with I(sub c)R(sub n) products in excess of a millivolt, using for instance, high-T(sub c) SNS bridges. We discuss the modifications to the classical RSJ model which are necessary in the quantum regime (h nu greater than kT), and conclude the Josephson mixers may attain noise temperatures less than ten times the quantum limit at high frequencies.

Schoelkopf, R.↗

Virtual Reality Simulation of the International Space Welding Experiment

Virtual Reality (VR) is a set of breakthrough technologies that allow a human being to enter and fully experience a 3-dimensional, computer simulated environment. A true virtual reality experience meets three criteria: (1) It involves 3-dimensional computer graphics; (2) It includes real-time feedback and response to user actions; and (3) It must provide a sense of immersion. Good examples of a virtual reality simulator are the flight simulators used by all branches of the military to train pilots for combat in high performance jet fighters. The fidelity of such simulators is extremely high -- but so is the price tag, typically millions of dollars. Virtual reality teaching and training methods are manifestly effective, and we have therefore implemented a VR trainer for the International Space Welding Experiment. My role in the development of the ISWE trainer consisted of the following: (1) created texture-mapped models of the ISWE's rotating sample drum, technology block, tool stowage assembly, sliding foot restraint, and control panel; (2) developed C code for control panel button selection and rotation of the sample drum; (3) In collaboration with Tim Clark (Antares Virtual Reality Systems), developed a serial interface box for the PC and the SGI Indigo so that external control devices, similar to ones actually used on the ISWE, could be used to control virtual objects in the ISWE simulation; (4) In collaboration with Peter Wang (SFFP) and Mark Blasingame (Boeing), established the interference characteristics of the VIM 1000 head-mounted-display and tested software filters to correct the problem; (5) In collaboration with Peter Wang and Mark Blasingame, established software and procedures for interfacing the VPL DataGlove and the Polhemus 6DOF position sensors to the SGI Indigo serial ports. The majority of the ISWE modeling effort was conducted on a PC-based VR Workstation, described below.

Phillips, James A.↗

Hair Styling Appliances

Key tool of Redken Laboratories new line of hair styling appliances is an instrument called a thermograph, a heat sensing device originally developed by Hughes Aircraft Co. under U.S. Army and NASA funding. Redken Laboratories bought one of the early models of the Hughes Probeye Thermal Video System or TVS which detects the various degrees of heat emitted by an object and displays the results in color on a TV monitor with colors representing different temperatures detected.

Source record↗

A Voice and Mouse Input Interface for 3D Virtual Environments

There have been many successful stories on how 3D input devices can be fully integrated into an immersive virtual environment. Electromagnetic trackers, optical trackers, gloves, and flying mice are just some of these input devices. Though we can use existing 3D input devices that are commonly used for VR applications, there are several factors that prevent us from choosing these input devices for our applications. One main factor is that most of these tracking devices are not suitable for prolonged use due to human fatigue associated with using them. A second factor is that many of them would occupy additional office space. Another factor is that many of the 3D input devices are expensive due to the unusual hardware that are required. For our VR applications, we want a user interface that would work naturally with standard equipment. In this paper, we demonstrate applications or our proposed muitimodal interface using a 3D dome display. We also show that effective data analysis can be achieved while the scientists view their data rendered inside the dome display and perform user interactions simply using the mouse and voice input. Though the sphere coordinate grid seems to be ideal for interaction using a 3D dome display, we can also use other non-spherical grids as well.