Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Large-scale transient sensitivity analysis of a radiation damaged bipolar junction transistor.

Automatic differentiation (AD) is useful in transient sensitivity analysis of a computational simulation of a bipolar junction transistor subject to radiation damage. We used forward-mode AD, implemented in a new Trilinos package called Sacado, to compute analytic derivatives for implicit time integration and forward sensitivity analysis. Sacado addresses element-based simulation codes written in C++ and works well with forward sensitivity analysis as implemented in the Trilinos time-integration package Rythmos. The forward sensitivity calculation is significantly more efficient and robust than finite differencing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fielding of a Time-Resolved Tomographic Diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an x-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, and adverse conditions will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XDesign : An open-source software package for designing X-ray imaging phantoms and experiments

Here, the development of new methods or utilization of current X-ray computed tomography methods is impeded by the substantial amount of expertise required to design an X-ray computed tomography experiment from beginning to end. In an attempt to make material models, data acquisition schemes and reconstruction algorithms more accessible to researchers lacking expertise in some of these areas, a software package is described here which can generate complex simulated phantoms and quantitatively evaluate new or existing data acquisition schemes and image reconstruction algorithms for targeted applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward resilient high performance applications through real time reliability metric generaion and autonomous failure correction

One predominant barrier encountered in furthering research and development efforts aimed at facilitating resilient HPC applications is a substantial lack of existing reliability and performance data originating from extreme-scale computing distributions. In order to develop an understanding of how and why highly scaled HPC applications are encountering increasingly frequent performance interruptions, one must conduct extensive trending and analysis on contemporary machines and their associated programs. However, existing HPC application log files are labyrinthine documents that, even with the assistance of intelligent data mining algorithms, translate poorly to human discern. In addition, conventional log filtering, processes are limited to execution within a post-mortem, reactive time period, as the enormous size of these documents prevents efficient real time interaction. Thus, there exists a strong need within the HPC field for the provision of accurate-yet-concise real time application information. Moreover, the means of reporting this data must be sufficiently lightweight and non-intrusive, as to successfully-yet-discretely attach itself to the multiple processes running on multiple cores within tens (or in some cases, hundreds) of thousands of compute nodes. Furthermore, this information should in turn be used to facilitate the autonomous correction of application-threatening faults, suspensions, and interruptions. This paper describes a dynamic application instrumentation module (utilizing a combination of Open/SpeedShop software and custom scripting) aimed at successfully achieving these goals.

97 MATHEMATICS AND COMPUTING↗

IB: a Monte Carlo Simulation Tool for Neutron Scattering Instrument Design under Parallel Virtual Machine

IB is a Monte Carlo simulation tool for aiding neutron scattering instrument designs. It is written in C++ and implemented under Parallel Virtual Machine. The program has a few basic components, or modules, that can be used to build a virtual neutron scattering instrument. More complex components, such as neutron guides and multichannel beam benders, can be constructed using the grouping technique unique to IB. Users can specify a collection of modules as a group. For example, a neutron guide can be constructed by grouping four neutron mirrors together that make up the four sides of the guide. IB s simulation engine ensures that neutrons entering a group will be properly operated upon by all members of the group. For simulations that require higher computer speed, the program can be run in parallel mode under the PVM architecture. Initially, the program was written for designing instruments on pulsed neutron sources, it has since been used to simulate reactor based instruments as well.

Monte Carlo Simulations↗

Identifying Opportunities at the Interface of Chemistry and Quantum Information Science (Final Technical Report)

This project convened a National Academies committee to identify opportunities and research priorities at the interface of chemistry and quantum information science (QIS). The work culminated in a consensus study report that (1) articulates three fundamental research areas to advance QIS (design and synthesis of molecular qubits; measurement and control of molecular quantum systems; and experimental and computational scaling of qubit design and function), and (2) underscores the importance of cross-disciplinary collaboration, access to facilities and instrumentation, FAIR-aligned data infrastructure, and workforce development initiatives to sustain U.S. leadership in QIS. The report and all other material associated with this project can be downloaded on the project webpage: https://www.nationalacademies.org/projects/DELS-BCST-21-01 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation Detection Computational Benchmark Scenarios

Modeling forms an important component of radiation detection development, allowing for testing of new detector designs, evaluation of existing equipment against a wide variety of potential threat sources, and assessing operation performance of radiation detection systems. This can, however, result in large and complex scenarios which are time consuming to model. A variety of approaches to radiation transport modeling exist with complementary strengths and weaknesses for different problems. This variety of approaches, and the development of promising new tools (such as ORNL’s ADVANTG) which combine benefits of multiple approaches, illustrates the need for a means of evaluating or comparing different techniques for radiation detection problems. This report presents a set of 9 benchmark problems for comparing different types of radiation transport calculations, identifying appropriate tools for classes of problems, and testing and guiding the development of new methods. The benchmarks were drawn primarily from existing or previous calculations with a preference for scenarios which include experimental data, or otherwise have results with a high level of confidence, are non-sensitive, and represent problem sets of interest to NA-22. From a technical perspective, the benchmarks were chosen to span a range of difficulty and to include gamma transport, neutron transport, or both and represent different important physical processes and a range of sensitivity to angular or energy fidelity. Following benchmark identification, existing information about geometry, measurements, and previous calculations were assembled. Monte Carlo results (MCNP decks) were reviewed or created and re-run in order to attain accurate computational times and to verify agreement with experimental data, when present. Benchmark information was then conveyed to ORNL in order to guide testing and development of hybrid calculations. The results of those ADVANTG calculations were then sent to PNNL for compilation. This is a report describing the details of the selected Benchmarks and results from various transport codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse pileup statistics for energy discriminating photon counting x-ray detectors

Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N{sub 0}, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analytically for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramer-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20%N{sub 0}, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiograph and passive data analysis using mixed variable optimization

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing radiography analysis. For example, certain embodiments perform radiographic analysis using mixed variable computation techniques. One exemplary system comprises a radiation source, a two-dimensional detector for detecting radiation transmitted through a object between the radiation source and detector, and a computer. In this embodiment, the computer is configured to input the radiographic image data from the two-dimensional detector and to determine one or more materials that form the object by using an iterative analysis technique that selects the one or more materials from hierarchically arranged solution spaces of discrete material possibilities and selects the layer interfaces from the optimization of the continuous interface data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Divertor IR thermography on Alcator C-Mod

Alcator C-Mod is a particularly challenging environment for thermography. It presents issues that will similarly face ITER, including low-emissivity metal targets, low-Z surface films, and closed divertor geometry. In order to make measurements of the incident divertor heat flux using IR thermography, the C-Mod divertor has been modified and instrumented. A 6 deg. toroidal sector has been given a 2 deg. toroidal ramp in order to eliminate magnetic field-line shadowing by imperfectly aligned divertor tiles. This sector is viewed from above by a toroidally displaced IR camera and is instrumented with thermocouples and calorimeters. The camera provides time histories of surface temperatures that are used to compute incident heat-flux profiles. The camera sensitivity is calibrated in situ using the embedded thermocouples, thus correcting for changes and nonuniformities in surface emissivity due to surface coatings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum effects on Higgs-strahlung events at linear colliders within the general two-Higgs-doublet model

The associated production of neutral Higgs bosons with the Z{sup 0} gauge boson (h{sup 0}Z{sup 0}, H{sup 0}Z{sup 0}) is investigated in the context of the future linear colliders, such as the ILC and CLIC, within the general two-Higgs-doublet model (2HDM). We compute the corresponding cross section for the processes e{sup +}e{sup -{yields}}Z{sup 0}h{sup 0}/Z{sup 0}H{sup 0} at one-loop, including the full set of corrections at O({alpha}{sub ew}{sup 3}) together with the leading O({alpha}{sub ew}{sup 4}) terms, in full consistency with the available theoretical and phenomenological constraints. We find that the wave-function corrections to the external Higgs fields are the dominant source of the quantum effects, which turn out to be large and negative (e.g., {delta}{sigma}/{sigma}{approx}-20%/-60%) in all the {radical}(s) range, and located predominantly in the region around tan{beta}{approx}1 and moderate values of the parameter {lambda}{sub 5} (being {lambda}{sub 5}<0). This behavior can be ultimately traced back to the enhancement potential of the triple Higgs-boson self-couplings, a trademark feature of the 2HDM with no counterpart in the Higgs sector of the minimal supersymmetric standard model. Even under this substantial depletion of the one-loop-corrected signal (which is also highly distinctive with respect to the SM expectation for e{sup +}e{sup -{yields}}Z{sup 0}H), the predicted Higgs-strahlung rates comfortably reach a few tens of femtobarn, which means barely {approx}10{sup 3}-10{sup 4} events per 500 fb{sup -1} of integrated luminosity. Because of their great complementarity, we argue that the combined analysis of the Higgs-strahlung events (h{sup 0}Z{sup 0}, H{sup 0}Z{sup 0}) and the previously computed one-loop Higgs-pair production processes (H{sup 0}A{sup 0}) could be instrumental to probe the structure of the Higgs sector at future linac facilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GPU-FPX

GPU-FPX is a tool based on NVBit that detects and analyzes floating-point exceptions on NVIDIA GPUs through binary instrumentation. Its purpose is to detect and report the occurrences of floating-point exceptions during numerical computations, offering efficient location detections and exception flow. GPUFPX achieves exceptional performance, being 16x faster than comparable prior tools, such as BinFPE.

Laguna Peralta, Ignacio↗