Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commonality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Contribution of {sup 68}Ga-DOTATOC PET/CT to Target Volume Delineation of Skull Base Meningiomas Treated With Stereotactic Radiation Therapy

Purpose: To investigate the potential impact of {sup 68}Ga-DOTATOC positron emission tomography ({sup 68}Ga-DOTATOC-PET) in addition to magnetic resonance imaging (MRI) and computed tomography (CT) for retrospectively assessing the gross tumor volume (GTV) delineation of meningiomas of the skull base in patients treated with fractionated stereotactic radiation therapy (FSRT). Methods and Materials: The study population consisted of 48 patients with 54 skull base meningiomas, previously treated with FSRT. After scans were coregistered, the GTVs were first delineated with MRI and CT data (GTV{sub MRI/CT}) and then by PET (GTV{sub PET}) data. The overlapping regions of both datasets resulted in the GTV{sub common}, which was enlarged to the GTV{sub final} by adding volumes defined by only one of the complementary modalities (GTV{sub MRI/CT-added} or GTV{sub PET-added}). We then evaluated the contribution of conventional imaging modalities (MRI, CT) and {sup 68}Ga-DOTATOC-PET to the GTV{sub final}, which was used for planning purposes. Results: Forty-eight of the 54 skull base lesions in 45 patients showed increased {sup 68}Ga-DOTATOC uptake and were further analyzed. The mean GTV{sub MRI/CT} and GTV{sub PET} were approximately 21 cm{sup 3} and 25 cm{sup 3}, with a common volume of approximately 15 cm{sup 3}. PET contributed a mean additional GTV of approximately 1.5 cm{sup 3} to the common volume (16% {+-} 34% of the GTV{sub common}). Approximately 4.5 cm{sup 3} of the GTV{sub MRI/CT} was excluded from the contribution to the common volume. The resulting mean GTV{sub final} was significantly smaller than both the GTV{sub MRI/CT} and the GTV{sub PET}. Compared with the initial GTV{sub MRI/CT}, the addition of {sup 68}Ga-DOTATOC-PET resulted in more than 10% modification of the size of the GTV{sub final} in 32 (67%) meningiomas Conclusions: {sup 68}Ga-DOTATOC-PET/CT seems to improve the target volume delineation in skull base meningiomas, often leading to a reduction of GTV compared with results from conventional imaging (MRI and CT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Occult Pelvic Lymph Node Involvement in Bladder Cancer: Implications for Definitive Radiation

Purpose: To inform radiation treatment planning for clinically staged, node-negative bladder cancer patients by identifying clinical factors associated with the presence and location of occult pathologic pelvic lymph nodes. Methods and Materials: The records of patients with clinically staged T1-T4N0 urothelial carcinoma of the bladder undergoing radical cystectomy and pelvic lymphadenectomy at a single institution were reviewed. Logistic regression was used to evaluate associations between preoperative clinical variables and occult pathologic pelvic or common iliac lymph nodes. Percentages of patient with involved lymph node regions entirely encompassed within whole bladder (perivesicular nodal region), small pelvic (perivesicular, obturator, internal iliac, and external iliac nodal regions), and extended pelvic clinical target volume (CTV) (small pelvic CTV plus common iliac regions) were calculated. Results: Among 315 eligible patients, 81 (26%) were found to have involved pelvic lymph nodes at the time of surgery, with 38 (12%) having involved common iliac lymph nodes. Risk of occult pathologically involved lymph nodes did not vary with clinical T stage. On multivariate analysis, the presence of lymphovascular invasion (LVI) on preoperative biopsy was significantly associated with occult pelvic nodal involvement (odds ratio 3.740, 95% confidence interval 1.865-7.499, P<.001) and marginally associated with occult common iliac nodal involvement (odds ratio 2.307, 95% confidence interval 0.978-5.441, P=.056). The percentages of patients with involved lymph node regions entirely encompassed by whole bladder, small pelvic, and extended pelvic CTVs varied with clinical risk factors, ranging from 85.4%, 95.1%, and 100% in non-muscle-invasive patients to 44.7%, 71.1%, and 94.8% in patients with muscle-invasive disease and biopsy LVI. Conclusions: Occult pelvic lymph node rates are substantial for all clinical subgroups, especially patients with LVI on biopsy. Extended coverage of pelvic lymph nodes up to the level of the common iliac nodes may be warranted in subsets of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

COSMIC: A Regimen of Intensity Modulated Radiation Therapy Plus Dose-Escalated, Raster-Scanned Carbon Ion Boost for Malignant Salivary Gland Tumors: Results of the Prospective Phase 2 Trial

Purpose: To investigate the effect of intensity modulated radiation therapy (IMRT) and dose-escalated carbon ion (C12) therapy in adenoid cystic carcinoma (ACC) and other malignant salivary gland tumors (MSGTs) of the head and neck. Patients and Methods: COSMIC (combined treatment of malignant salivary gland tumors with intensity modulated radiation therapy and carbon ions) is a prospective phase 2 trial of 24 Gy(RBE) C12 followed by 50 Gy IMRT in patients with pathologically confirmed MSGT. The primary endpoint is mucositis Common Terminology Criteria grade 3; the secondary endpoints are locoregional control (LC), progression-free survival (PFS), overall survival (OS), and toxicity. Toxicity was scored according to the Common Terminology Criteria for Adverse Events version 3; treatment response was scored according to Response Evaluation Criteria in Solid Tumors 1.1. Results: Between July 2010 and August 2011, 54 patients were accrued, and 53 were available for evaluation. The median follow-up time was 42 months; patients with microscopically incomplete resections (R1, n=20), gross residual disease (R2, n=17), and inoperable disease (n=16) were included. Eighty-nine percent of patients had ACC, and 57% had T4 tumors. The most common primary sites were paranasal sinus (34%), submandibular gland, and palate. At the completion of radiation therapy, 26% of patients experienced grade 3 mucositis, and 20 patients reported adverse events of the ear (38%). The most common observed late effects were grade 1 xerostomia (49%), hearing impairment (25%, 2% ipsilateral hearing loss), and adverse events of the eye (20%), but no visual impairment or loss of vision. Grade 1 central nervous system necrosis occurred in 6%, and 1 grade 4 ICA hemorrhage without neurologic sequelae. The best response was 54% (complete response/partial remission). At 3 years, the LC, PFS, and OS were 81.9%, 57.9%, and 78.4%, respectively. No difference was found regarding resection status. The most common site of failure was distant (55%). Local relapse was predominantly in field (79%). Conclusion: Treatment was tolerated, with moderate acute and late toxicity. The LC at 3 years was promising. No significant difference could be shown regarding resection status; hence, extensive and mutilating surgical procedures should be rediscussed. Further dose escalation may be limited in view of potential vascular adverse events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stability and coalescence of massive twin binaries

Massive stars are usually found in binaries, and binaries with periods less than 10 days may have a preference for near equal component masses (“twins”). In this paper we investigate the evolution of massive twin binaries all the way to contact and the possibility that these systems can be progenitors of double neutron star binaries. The small orbital separations of observed double neutron star binaries suggest that the progenitor systems underwent a common envelope phase at least once during their evolution. Bethe and Brown proposed that massive binary twins will undergo a common envelope evolution while both components are ascending the red giant branch (RGB) or asymptotic giant branch (AGB) simultaneously, also known as double-core evolution. Using models generated from the stellar evolution code EZ (evolve zero-age main sequence), we determine the range of mass ratios resulting in a contact binary with both components simultaneously ascending the RGB or AGB as a function of the difference in birth times, Δτ. We find that, even for a generous Δτ = 5 Myr, the minimum mass ratio q{sub min}=0.933 for an 8 M{sub ⊙} primary and increases for larger mass primaries. We use a smoothed particle hydrodynamics code, StarSmasher, to study specifically the evolution of q = 1 common envelope systems as a function of initial component mass, age, and orbital separation. We also consider a q = 0.997 system to test the effect of relaxing the constraint of strictly identical components. We find the dynamical stability limit, the largest orbital separation where the binary becomes dynamically unstable, as a function of the component mass and age. Finally, we calculate the efficiency of ejecting matter during the inspiral phase to extrapolate the properties of the remnant binary from our numerical results, assuming the common envelope is completely ejected. We find that for the nominal core masses, there is a minimum orbital separation for a given component mass such that the helium cores survive common envelope evolution in a tightly bound binary and are viable progenitors for double neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-E-18A-01: Developments in Monte Carlo Methods for Medical Imaging

Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.

60 APPLIED LIFE SCIENCES↗

IBEX: An open infrastructure software platform to facilitate collaborative work in radiomics

Purpose: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The IBEX software package was developed using the MATLAB and C/C++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and C/C++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX’s functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX’s source code can be downloaded. Conclusions: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.

60 APPLIED LIFE SCIENCES↗

Role of local geometry in the spin and orbital structure of transition metal compounds

We analyze the role of local geometry in the spin and orbital interaction in transition metal compounds with orbital degeneracy. We stress that the tendency observed in the most studied case (transition metals in O{sub 6} octahedra with one common oxygen—common corner of neighboring octahedra—and with ~180° metal–oxygen–metal bonds), that ferro-orbital ordering renders antiferro-spin coupling and, vice versa, antiferro-orbitals give ferro-spin ordering, is not valid in the general case, in particular, for octahedra with a common edge and with ~90° M–O–M bonds. Special attention is paid to the “third case,” that of neighboring octahedra with a common face (three common oxygens), which has largely been disregarded until now, although there are many real systems with this geometry. Interestingly enough, the spin-orbit exchange in this case turns out to be simpler and more symmetric than in the first two cases. We also consider, which form the effective exchange takes for different geometries in the case of strong spin–orbit coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pivotal trial characteristics and types of endpoints used to support Food and Drug Administration rare disease drug approvals between 2013 and 2022

Background/aims Rare disease drug development faces unique challenges, such as genotypic and phenotypic heterogeneity within small patient populations and a lack of established outcome measures for conditions without previously successful drug development programs. These challenges complicate the process of selecting the appropriate trial endpoints and conducting clinical trials in rare diseases. In this descriptive study, we examined novel drug approvals for non-oncologic rare diseases by the U.S. Food and Drug Administration’s Center for Drug Evaluation and Research over the past decade and characterized key regulatory and trial design elements with a focus on the primary efficacy endpoint utilized as the basis of approval. Methods Using the Food and Drug Administration’s Data Analysis Search Host database, we identified novel new drug applications and biologics license applications with orphan drug designation that were approved between 2013 and 2022 for non-oncologic indications. From Food and Drug Administration review documents and other external databases, we examined characteristics of pivotal trials for the included drugs, such as therapeutic area, trial design, and type of primary efficacy endpoints. Differences in trial design elements associated with primary efficacy endpoint type were assessed such as randomization and blinding. Then, we summarized the primary efficacy endpoint types utilized in pivotal trials by therapeutic area, approval pathway, and whether the disease etiology is well defined. Results One hundred and seven drugs that met our inclusion criteria were approved between 2013 and 2022. Assessment of the 107 drug development programs identified 150 pivotal trials that were subsequently analyzed. The pivotal trials were mostly randomized (80%) and blinded (69.3%). Biomarkers (41.1%) and clinical outcomes (42.1%) were commonly utilized as primary efficacy endpoints. Analysis of the use of clinical trial design elements across trials that utilized biomarkers, clinical outcomes, or composite endpoints did not reveal statistically significant differences. The choice of primary efficacy endpoint varied by the drug’s therapeutic area, approval pathway, and whether the indicated disease etiology was well defined. For example, biomarkers were commonly selected as primary efficacy endpoints in hematology drug approvals (70.6%), whereas clinical outcomes were commonly selected in neurology drug approvals (69.6%). Further, if the disease etiology was well defined, biomarkers were more commonly used as primary efficacy endpoints in pivotal trials (44.7%) than if the disease etiology was not well defined (27.3%). Discussion In the past 10 years, numerous novel drugs have been approved to treat non-oncologic rare diseases in various therapeutic areas. To demonstrate their efficacy for regulatory approval, biomarkers and clinical outcomes were commonly utilized as primary efficacy endpoints. Biomarkers were not only frequently used as surrogate efficacy endpoints in accelerated approvals, but also in traditionally approved rare disease drugs. The choice of primary efficacy endpoints varied by therapeutic area, approval pathway, and understanding of disease etiology.

Hong, Kyungwan [Rare Diseases Team, Office of New ↗

Comparative Architecture Analysis: Using Laminar Structure to Unify Multiple Grid Architectures

A great many architectures for various aspects of electric grids have been proposed over recent years and new ones continue to be suggested. Generally speaking, there is no means except ad hoc analysis by which one can reduce these architectures to some common basis, or extract common elements. This leads to confusion in choosing an architecture for implementation, as well as making it difficult to identify core product or platform opportunities with sufficient potential markets to encourage vendors to provide or develop them. The discipline of Grid Architecture as defined for the US Department of Energy (DOE) in 2014 has multiple purposes. Among them are two that are relevant here: Providing rigorous bases for architectural structures and Identifying common aspects of apparently divergent architectural structures. For the first of these, mathematical methods are applied where possible to provide the rigorous basis for structure. For the second, mapping of architectural structures to a canonical structure puts apparently disparate architectures onto a common basis. In the best case, these two methods coincide. In this paper, Laminar Coordination structure serves as the rigorously defined common basis for analysis of several real and proposed grid architectures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Waste Management Project Success - Regulatory Assurance Systems - 20118

Waste management (WM) and remediation projects are essential within a restorative environmental culture. Despite years of experience, challenges and obstacles associated with efficient and effective WM project execution remain. Although some obstacles are project specific, a common challenge is navigating the regulatory landscape from planning through execution, particularly with first of a kind (FOAK) and first in a while (FIAW) projects. The absence of a comprehensive regulatory assurance strategy places significant hurdles in the path of project success. To clear a path for the successful execution of increasingly complex WM projects, this paper focuses on development of a comprehensive regulatory assurance strategy and implementation plan that effectively engages stakeholders, agencies, and performers to produce project plans that fully and cost effectively integrate applicable regulatory requirements. The most reliable way to align regulatory processes and decisions needed for mission success is through a regulatory assurance system. This system establishes a healthy interface with regulatory decision makers, to work in a collaborative manner, to create a common vision for regulatory decisions on an agreed upon schedule. A regulatory assurance system consists of several elements. Although the mission may vary from cleanup to site closure to nuclear component production, the elements of a regulatory assurance system remain essentially constant and must include: 1) identifying a common vision or end state, 2) developing a long-term, integrated strategy and schedule, 3) establishing a regulatory partnering team consisting of key decision-makers, 4) regular and frequent communication with decision-makers, 5) ensuring consistent surveillance for early identification of issues and changes that may impact the project, 6) quick resolution of emerging issues to prevent schedule impact, 7) identifying core compliance functions, 8) periodically assessing progress of the project as it relates to regulatory assurance and, 9) providing constructive feedback to improve the process. A regulatory assurance system provides a living, multi-faceted approach to planning, visioning, communicating and tracking to avoid surprises and ensure smooth and timely progress to the project. The overall success measures will be whether the system produces common sense regulatory decisions supporting the vision on time without appeal. Effective regulatory frameworks rarely happen on their own. Balanced, common-sense regulatory decisions stem from teams that are trained to work together to achieve shared goals. In this paper, particular attention is placed on the importance of starting with a shared vision for a regulatory assurance and execution strategy that leverages experience to establish optimal approaches. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electric and Hydraulic Propel Torque Modulation for a Compact Track Loader With the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic Electric Architecture (HHEA) has previously been proposed for off-highway vehicles to reap the efficiency and controllability benefits of electrification without needing very large electric motors. This is achieved with the use of a set of selectable common pressure rails to transmit the majority of power and small electric motors to modulate that power. Previous work has shown significant energy savings for the work circuits of a variety of machines. In this paper, the energy saving potential of HHEA for the propel circuit of a compact track loader is studied. The ports of the track hydraulic motors are selectably connected to the common pressure rails, and instead of using the electric assist motors to buck/boost pressure, as in HHEA for linear actuators, small electric assist motors are used to add/subtract torque directly. The interplay between the torque limits of the electric motors and the ability of the hydraulic motor to vary displacements is studied, along with the effect these factors have on energy saving potential. It is found that the ability to vary the displacement of the hydraulic motor allows for: more efficient electric motor operating conditions, reduced electric torque requirement, and reduced pressure rail switching events. All three of these advantages can be achieved at once using variable displacements; but trade-offs exist between these advantages (i.e. improved efficiency can be achieved at the expense of a larger electric torque requirement). Overall, the HHEA can reduce energy consumption by ∼ 36% compared to the stock machine, depending on the hydraulic motor’s ability to vary displacements, and assuming the electric motor torque is limited to 20% of that required in a direct electrification scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Finding a Minimally Informative Dirichlet Prior Distribution Using Least Squares

In a Bayesian framework, the Dirichlet distribution is the conjugate distribution to the multinomial likelihood function, and so the analyst is required to develop a Dirichlet prior that incorporates available information. However, as it is a multiparameter distribution, choosing the Dirichlet parameters is less straight-forward than choosing a prior distribution for a single parameter, such as p in the binomial distribution. In particular, one may wish to incorporate limited information into the prior, resulting in a minimally informative prior distribution that is responsive to updates with sparse data. In the case of binomial p or Poisson, the principle of maximum entropy can be employed to obtain a so-called constrained noninformative prior. However, even in the case of p, such a distribution cannot be written down in closed form, and so an approximate beta distribution is used in the case of p. In the case of the multinomial model with parametric constraints, the approach of maximum entropy does not appear tractable. This paper presents an alternative approach, based on constrained minimization of a least-squares objective function, which leads to a minimally informative Dirichlet prior distribution. The alpha-factor model for common-cause failure, which is widely used in the United States, is the motivation for this approach, and is used to illustrate the method. In this approach to modeling common-cause failure, the alpha-factors, which are the parameters in the underlying multinomial aleatory model for common-cause failure, must be estimated from data that is often quite sparse, because common-cause failures tend to be rare, especially failures of more than two or three components, and so a prior distribution that is responsive to updates with sparse data is needed.

99 GENERAL AND MISCELLANEOUS↗

Finding A Minimally Informative Dirichlet Prior Using Least Squares

In a Bayesian framework, the Dirichlet distribution is the conjugate distribution to the multinomial likelihood function, and so the analyst is required to develop a Dirichlet prior that incorporates available information. However, as it is a multiparameter distribution, choosing the Dirichlet parameters is less straightforward than choosing a prior distribution for a single parameter, such as p in the binomial distribution. In particular, one may wish to incorporate limited information into the prior, resulting in a minimally informative prior distribution that is responsive to updates with sparse data. In the case of binomial p or Poisson \lambda, the principle of maximum entropy can be employed to obtain a so-called constrained noninformative prior. However, even in the case of p, such a distribution cannot be written down in the form of a standard distribution (e.g., beta, gamma), and so a beta distribution is used as an approximation in the case of p. In the case of the multinomial model with parametric constraints, the approach of maximum entropy does not appear tractable. This paper presents an alternative approach, based on constrained minimization of a least-squares objective function, which leads to a minimally informative Dirichlet prior distribution. The alpha-factor model for common-cause failure, which is widely used in the United States, is the motivation for this approach, and is used to illustrate the method. In this approach to modeling common-cause failure, the alpha-factors, which are the parameters in the underlying multinomial model for common-cause failure, must be estimated from data that are often quite sparse, because common-cause failures tend to be rare, especially failures of more than two or three components, and so a prior distribution that is responsive to updates with sparse data is needed.

99 GENERAL AND MISCELLANEOUS↗

Micro-Spectroscopic Imaging and Characterization of Individually Identified Ice Nucleating Particles from a Case Field Study

The effect of anthropogenic and biogenic organic particles on atmospheric glaciation processes is poorly understood. We use an optical microscopy (OM) setup to identify the location of ice nuclei (IN) active in immersion freezing and deposition ice nucleation for temperatures of 200-273 K within a large population of particles sampled from an ambient environment. Applying multi-modal micro-spectroscopy methods we characterize the physicochemical properties of individual IN in particle populations collected in central California. Chemical composition and mixing state analysis of particle populations are performed to identify characteristic particle-type classes. All particle-types contained organic material. Particles in these samples take up water at subsaturated conditions, induce immersion freezing at subsaturated and saturated conditions above 226 K, and act as deposition IN below 226 K. The identified IN belong to the most common particle-type classes observed in the field samples: organic coated sea salt, Na-rich, and secondary and refractory carbonaceous particles. Based on these observations, we suggest that the IN are not always particles with unique chemical composition and exceptional ice nucleation propensity; rather, they are common particles in the ambient particle population. Thus, particle composition and morphology alone are insufficient to assess their potential to act as IN. The results suggest that particle-type abundance is also a crucial factor in determining the ice nucleation efficiency of specific IN types. These findings emphasize that ubiquitous organic particles can induce ice nucleation under atmospherically relevant conditions and that they may play an important role in atmospheric glaciation processes.

Environmental Molecular Sciences Laboratory↗

River stage influences on uranium transport in a hydrologically dynamic groundwater-surface water transition zone

In this study, a well-field within a uranium (U) plume in the groundwater-surface water transition zone was monitored for a 3 year period for water table elevation and dissolved solutes. The plume discharges to the Columbia River, which displays a dramatic spring stage surge resulting from snowmelt. Groundwater exhibits a low hydrologic gradient and chemical differences with river water. River water intrudes the site in spring. Specific aims were to assess the impacts of river intrusion on dissolved uranium (U aq ), specific conductance (SpC), and other solutes, and to discriminate between transport, geochemical, and source term heterogeneity effects. Time series trends for U aq and SpC were complex and displayed large temporal and well-to-well variability as a result of water table elevation fluctuations, river water intrusion, and changes in groundwater flow directions. The wells were clustered into subsets exhibiting common behaviors resulting from the intrusion dynamics of river water and the location of source terms. Hot-spots in U aq varied in location with increasing water table elevation through the combined effects of advection and source term location. Heuristic reactive transport modeling with PFLOTRAN demonstrated that mobilized U aq was transported between wells and source terms in complex trajectories, and was diluted as river water entered and exited the groundwater system. While U aq time-series concentration trends varied significantly from year-to-year as a result of climate-caused differences in the spring hydrograph, common and partly predictable response patterns were observed that were driven by water table elevation, and the extent and duration of river water intrusion.

54 ENVIRONMENTAL SCIENCES↗

An International Laboratory Comparison Study of Volumetric and Gravimetric Hydrogen Adsorption Measurements

In order to determine a material's hydrogen storage potential, capacity measurements must be robust, reproducible, and accurate. Commonly, research reports focus on the gravimetric capacity, and often times the volumetric capacity is not reported. Determining volumetric capacities is not as straight-forward, especially for amorphous materials. This is the first study to compare measurement reproducibility across laboratories for excess and total volumetric hydrogen sorption capacities based on the packing volume. The use of consistent measurement protocols, common analysis, and figure of merits for reporting data in this study, enable the comparison of the results for two different materials. Importantly, the results show good agreement for excess gravimetric capacities amongst the laboratories. Irreproducibility for excess and total volumetric capacities is attributed to real differences in the measured packing volume of the material.

H2 storage↗

Phaseolus vulgaris SUT1.1 is a high affinity sucrose–proton co–transporter

Plant sucrose transporters are required for phloem loading, and therefore are essential for plant growth and development. In common beans (Phaseolus vulgaris) there are only two sucrose transporters functionally characterized. Through a previous RNA-seq study, we identified a putative sucrose transporter in common bean, which we hypothesize to function in import of sucrose into plant cells. In silico analysis revealed that PvSUT1.1 is a putative sucrose-proton co-transporter distinct from other characterized sucrose transporters in common bean indicating that this is a previously undescribed transporter protein in beans. Further analysis revealed that PvSUT1.1 shares high protein sequence homology to the phloem loader Arabidopsis SUC2; both have 12 transmembrane domains, a typical characteristic of plant sucrose transporters. Heterologous expression in yeast further showed PvSUT1.1 to be functional and it imported sucrose into yeast cells with a K m of 0.7 mM sucrose. Import of sucrose through PvSUT1.1 is also pH-dependent with highest uptake at pH 4.0, and activity is lost in the presence of the uncoupler carbonyl cyanide 3-chlorophenylhydrazone. Consistent with identification of PvSUT1.1 as a Type I transporter, PvSUT1.1 also transports esculin. Finally, PvSUT1.1 showed expression in multiple tissues and the protein was localized to the plasma membrane. The results show that PvSUT1.1 is a sucrose transporter that is probably involved in the uptake of sucrose into source and sink cells. The potential role of PvSUT1.1 in leaf phloem loading of sucrose in common beans and its importance in heat tolerance of reproductive tissues are further discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Cardiovascular findings on cross-sectional imaging: spectrum of incidental and critical findings and clinical relevance for the abdominal radiologist

Although not the primary focus of the exams, cardiovascular structures are included to some extent on all abdominal or whole-body cross-sectional studies. Cardiovascular findings often present incidentally and may range from chronic to acute and emergent pathologies. Among the most common cardiovascular findings are the presence of cardiac calcifications, most commonly coronary, which correlate with the presence of coronary artery and valvular disease. Signs of myocardial ischemia, both acute and chronic, and its complications may also be visualized. Cardiac filling defects most commonly represent thrombus and are associated with systemic arterial embolic complications. Pericardial findings often manifest as effusion or thickening, which may lead to hemodynamic consequences visible at imaging. Incidental pulmonary emboli and systemic venous thrombi may be incidentally detected, particularly in hospitalized and oncologic patients, and warrant immediate attention. This review will highlight the appearance of common and important incidental cardiovascular findings and related pitfalls and discuss reporting and follow-up recommendations relevant to the abdominal radiologist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗