Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CdS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,004 records · Page 56

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

43 PARTICLE ACCELERATORS↗

Treatment of G1 Baskets at the CEA Marcoule Site - 12027

In the dismantling program for the first-generation French reactors in accordance with the nonproliferation treaty, the CEA is in charge of cleanup and dismantling operations for the facilities at Marcoule, including the decladding units. The G1 decladding was built between 1955 and 1957 in order to de-clad spent fuel elements from the G1 plutonium-producing reactor and prepare them for dissolution. The facility was also used for interim storage of G1, G2 and G3 fuel dissolution baskets, which had been used during plant operation for transfer (from the decladding facility to the UP1 plant) and/or dissolution of spent fuel elements. One of the cleanup projects involves recovery of the baskets, which will be cut up, sorted, and conditioned in metal bins. The bins will be immobilized with cement grout, then transferred to the onsite solid waste conditioning facility (CDS) and to the repository operated by the French National Radioactive Waste Management Agency (ANDRA). The project is now in progress, after special safety permits were issued and measurement stations and dedicated tools were developed to handle all types of baskets (which differed according to their origin and use). The disposal of all the baskets is scheduled to last 2 years and will produce 55 metal waste bins. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uncertainty Quantification and Sensitivity Analysis of Non-Nuclear Advanced Controls Testbed Reactor Mockup

The research presented in this report describes our progress in applying stochastic methods and uncertainty quantification, parametric study, and variance-based sensitivity analysis (also known as Sobol sensitivity analysis) to a full-core model of a nuclear thermal propulsion (NTP) system simulated with Griffin, with the goal of developing a reduced order (surrogate) model which can be rapidly sampled while perturbing multiple input parameters. In this NTP system, reactivity and power feedback affect the rotation of control drums, which are controlled by a hybrid proportional, integral and derivative (PID) controller, actuated by the power demand and reactivity feedback from the numerical model. This model uses reactor kinetic feedback (mean generation time and $\beta$ from a transient Griffin simulation executed with the improved quasi-static method to provide the kinetic parameters) as inputs to functions which control the CD rotation angle. Using a number of stochastic method approaches, we developed a dual purpose training-surrogate model of the NTP system using polynomial regression. The trained model can be rapidly sampled while simultaneously perturbing various input parameters of the model, such as coefficients on the PID control, or temperature (directly affect the neutron cross section). The surrogate model delivers accurate results orders-of-magnitude faster (minutes, not days) than the base model. Once the base model has been trained, distributions of the uncertain parameters can be changed at will to investigate the effects of perturbing multiple inputs and their effect on the output. For example, coefficients used in the PID control system may vary due to some physical interference, or there may be uncertainty in the temperature of the neutron cross sections in various regions of the reactor. A distribution can be placed on these parameters and operational boundaries can be determined. The goal of this work is to support development of an advanced control system to operate CDs in a functioning NTP system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Exploration Medical Capability Clinical Decision Support Use Cases for CDSS Test Bed

Long-duration, deep-space exploration missions present significant challenges to crew health and performance. These challenges include the individual and combined effects of microgravity, radiation exposure, isolation, limited resources (mass, volume, power, data, and crew time), limited options for evacuation, and those associated with delayed or constrained communications. Each of these challenges necessitates greater degrees of crew autonomy as our distance from Earth increases. Specifically, as communication delays intensify - and evacuation capability diminishes the further we explore space - the unqualified need for Earth-independent medical operations focused on autonomous diagnosis, treatment and prevention will become key to mission continuation and success. This need will be especially true should a crewmember become ill or injured wherein treatment and disposition “in-situ” ultimately falls to the crew itself to determine. To augment the requisite knowledge, skills, and abilities (KSAs) of a time-constrained exploration mission crew operating under stressful conditions, combatting fatigue, and facing a potential medical crisis, a robust clinical decision support system (CDSS) is a probable solution. A CDSS would facilitate, guide, and inform Earth-independent medical operations while assisting crewmembers through various clinical presentations. The CDSS would allow crewmembers to take advantage of pre-mission training tied to the in-flight/in-mission use of pre-planned protocols that offer both a range of diagnostic options and “just-in-time” (refamiliarization) training and assistance. CDSS will expand such capabilities by improving the utility and effectiveness of various available diagnostic, treatment, and health maintenance tools, techniques, and measures.

ExMC↗

Large metastability in Cu (In,Ga)Se 2 devices: The importance of buffer properties

Some commercial Cu (In,Ga)Se 2 (CIGS) modules reveal large changes in current-voltage parameters with light soaking. While such changes are not necessarily indicative of a performance problem, the associated uncertainty may be disadvantageous in a highly competitive market. Thus, it is beneficial to understand the origin of large metastabilities in order to define what processing changes might diminish metastability without impacting other desirable aspects of high-performance devices. This report attempts to reproduce large metastabilities like those in some commercial products both through absorber and buffer processing variations in small devices. While variations of both types were found to affect metastability, only buffer variations could reproduce large metastability in high-efficiency devices. Device modeling validates that buffer effects alone are sufficient to explain the large metastability seen in these devices.

14 SOLAR ENERGY↗

DNA Crystals as a Template for Patterned Functional Materials

DNA nanotechnology offers a wide toolkit of molecular functionalities and scales, including intricate motifs less than 10 nm and periodic structures exceeding 100 µm. At larger scales, however, there are often significant tradeoffs for DNA structures, namely stability and mechanical strength. This work describes the design, synthesis, and characterization of a functionalized DNA crystal. Using a ligated DNA crystal grants significant freedom for various functional materials to be applied, in this case, semiconducting cadmium sulfide and palladium metal. Properties investigated in this study include stability, mechanical strength, and optoelectronic properties such as photoluminescence (PL) and electric conductivity. Significant changes are observed based on the functional material applied to DNA crystals. The Young's modulus of the crystal varies by about five orders of magnitude when functionalized with palladium. PL and semiconductive behaviors were observed when cadmium sulfide was attached. These crystals represent an expansion of the capabilities of DNA structures at these length scales, and additionally a platform for future studies exchanging the materials or altering the ligation scheme.

CdS↗

Pre-Mastering and CD-WO Evaluations

This article reviews the features and functionality of five desktop pre-mastering software packages for the PC. Desktop pre-mastering packages are aimed primarily at end-users interested in bringing CD-ROM publishing tasks in-house, rather than traditional CD-ROM developers.

software packages multi-platform CDs PC Macintosh ↗

System Upgrades at the Advanced Test Reactor Help Ensure that Nuclear Energy Research Continues at the Idaho National Laboratory

Fully operational in 1967, the Advanced Test Reactor (ATR) is a first-of-its-kind materials test reactor. Located on the Idaho National Laboratory’s desert site, this reactor remains at the forefront of nuclear science, producing extremely high neutron irradiation in a relatively short time span. The Advanced Test Reactor is also the only U.S. reactor that can replicate multiple reactor environments concurrently. The Idaho National Laboratory and the Department of Energy recently invested over 13 million dollars to replace three of ATR’s instrumentation and control systems. The new systems offer the latest software and technology advancements, ensuring the availability of the reactor for future energy research. Engineers and project managers successfully completed the four year project in March while the ATR was in a scheduled maintenance outage. “These new systems represent state-of-the-art monitoring and annunciation capabilities,” said Don Feldman, ATR Station Manager. “They are comparable to systems currently used for advanced reactor designs planned for construction in the U.S. and in operation in some foreign countries.”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analog Video Authentication and Seal Verification Equipment Development

Under contract to the US Department of Energy in support of arms control treaty verification activities, the Savannah River National Laboratory in conjunction with the Pacific Northwest National Laboratory, the Idaho National Laboratory and Milagro Consulting, LLC developed equipment for use within a chain of custody regime. This paper discussed two specific devices, the Authentication Through the Lens (ATL) analog video authentication system and a photographic multi-seal reader. Both of these devices have been demonstrated in a field trial, and the experience gained throughout will also be discussed. Typically, cryptographic methods are used to prove the authenticity of digital images and video used in arms control chain of custody applications. However, in some applications analog cameras are used. Since cryptographic authentication methods will not work on analog video streams, a simple method of authenticating analog video was developed and tested. A photographic multi-seal reader was developed to image different types of visual unique identifiers for use in chain of custody and authentication activities. This seal reader is unique in its ability to image various types of seals including the Cobra Seal, Reflective Particle Tags, and adhesive seals. Flicker comparison is used to compare before and after images collected with the seal reader in order to detect tampering and verify the integrity of the seal.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗