Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COURSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Early Assessment of Treatment Responses During Radiation Therapy for Lung Cancer Using Quantitative Analysis of Daily Computed Tomography

Purpose: To investigate early tumor and normal tissue responses during the course of radiation therapy (RT) for lung cancer using quantitative analysis of daily computed tomography (CT) scans. Methods and Materials: Daily diagnostic-quality CT scans acquired using CT-on-rails during CT-guided RT for 20 lung cancer patients were quantitatively analyzed. On each daily CT set, the contours of the gross tumor volume (GTV) and lungs were generated and the radiation dose delivered was reconstructed. The changes in CT image intensity (Hounsfield unit [HU]) features in the GTV and the multiple normal lung tissue shells around the GTV were extracted from the daily CT scans. The associations between the changes in the mean HUs, GTV, accumulated dose during RT delivery, and patient survival rate were analyzed. Results: During the RT course, radiation can induce substantial changes in the HU histogram features on the daily CT scans, with reductions in the GTV mean HUs (dH) observed in the range of 11 to 48 HU (median 30). The dH is statistically related to the accumulated GTV dose (R{sup 2} > 0.99) and correlates weakly with the change in GTV (R{sup 2} = 0.3481). Statistically significant increases in patient survival rates (P=.038) were observed for patients with a higher dH in the GTV. In the normal lung, the 4 regions proximal to the GTV showed statistically significant (P<.001) HU reductions from the first to last fraction. Conclusion: Quantitative analysis of the daily CT scans indicated that the mean HUs in lung tumor and surrounding normal tissue were reduced during RT delivery. This reduction was observed in the early phase of the treatment, is patient specific, and correlated with the delivered dose. A larger HU reduction in the GTV correlated significantly with greater patient survival. The changes in daily CT features, such as the mean HU, can be used for early assessment of the radiation response during RT delivery for lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Adaptive Radiation Therapy

The current paradigm of radiation therapy has the treatment planned on a snapshot dataset of the patient's anatomy taken at the time of simulation. Throughout the course of treatment, this snapshot may vary from initial simulation. Although there is the ability to image patients within the treatment room with technologies such as cone beam computed tomography, the current state of the art is largely limited to rigid-body matching and not accounting for any geometric deformations in the patient's anatomy. A plan that was once attuned to the initial simulation can become suboptimal as the treatment progresses unless improved technologies are brought to bear. Adaptive radiation therapy (ART) is an evolving paradigm that seeks to address this deficiency by accounting for ongoing changes in the patient's anatomy and/or physiology during the course of treatment, affording an increasingly more accurate targeting of disease. ART relies on several components working in concert, namely in-room treatment image guidance, deformable image registration, automatic recontouring, plan evaluation and reoptimization, dose calculation, and quality assurance. Various studies have explored how a putative ART solution would improve the current state of the art of radiation therapy—some centers have even clinically implemented online adaptation. These explorations are reviewed here for a variety of sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peripheral Blood Biomarkers Associated With Toxicity and Treatment Characteristics After 131 I- Metaiodobenzylguanidine Therapy in Patients With Neuroblastoma

We report few tools exist to predict clinical outcomes after radiopharmaceutical therapy. Our goal was to identify associations between blood-based biomarkers of radiation effect and clinical outcomes after 131 I-metaiodobenzylguanidine ( 131 I-MIBG) therapy in patients with neuroblastoma. We conducted a prospective, single-center cohort study in children with advanced neuroblastoma treated with 131 I-MIBG as monotherapy or in combination with systemic putative radiation sensitizers. We collected serial peripheral blood samples after 131 I-MIBG infusions and quantified a panel of protein and messenger RNA markers. We plotted relative change from baseline to assess degree of modulation over time and then evaluated association of marker modulation with toxicity and response endpoints. The cohort included 40 patients (30 male/10 female; median age 7 years). We observed significant modulation of the majority of markers between baseline and hour 72 after 131 I-MIBG. Greater fold increase of plasma FLT3 ligand was associated with subsequent grade 4 neutropenia (P=.039). Modulation of peripheral blood BCLXL and DDB2 was associated with grade 3+ nonhematologic toxicity (P=.043 and .048, respectively). No markers were associated with tumor response. Greater plasma FLT3 ligand, BCLXL, and BCL2 modulation was observed in patients receiving 131 I-MIBG in combination with radiation sensitizers. Among 9 patients who received 2 courses, the degree of modulation in serum amylase was significantly lower after the second course (P=.012). Peripheral blood biomarkers relevant to radiation exposure are significantly modulated during the acute period after 131 I-MIBG. The degree of modulation of a subset of these markers is associated with toxicity and receipt of concomitant radiation sensitizers.

131I-MIBG↗

Consensus Guidelines for Implementing Pencil-Beam Scanning Proton Therapy for Thoracic Malignancies on Behalf of the PTCOG Thoracic and Lymphoma Subcommittee

Pencil-beam scanning (PBS) proton therapy (PT), particularly intensity modulated PT, represents the latest advanced PT technology for treating cancers, including thoracic malignancies. On the basis of virtual clinical studies, PBS-PT appears to have great potential in its ability to tightly tailor the dose to the target while sparing critical structures, thereby reducing treatment-related toxicities, particularly for tumors in areas with complicated anatomy. However, implementing PBS-PT for moving targets has several additional technical challenges compared with intensity modulated photon radiation therapy or passive scattering PT. Four-dimensional computed tomography–based motion management and robust optimization and evaluation are crucial for minimizing uncertainties associated with beam range and organ motion. Rigorous quality assurance is required to validate dose delivery both before and during the course of treatment. Active motion management (eg, breath hold), beam gating, rescanning, tracking, or adaptive planning may be needed for cases involving significant motion or changes in motion or anatomy over the course of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Remote Learning as Effective as In-Person Learning for Contouring Education? A Prospective Comparison of Face-to-Face versus Online Delivery of the Anatomy and Radiology Contouring Bootcamp

The Anatomy and Radiology Contouring (ARC) Bootcamp was a face-to-face (F2F) intervention providing integrated education for radiation oncology (RO) residents and medical physicists. To increase access, we launched an online offering in 2019. We evaluated the effect of the online course on participants' knowledge acquisition, contouring skills, and self-confidence by comparing it with the F2F course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Insight Into the High-Potential Branch of the Alternate Nad+-Dependent NADPH:Ferredoxin Oxidoreductase II (NfnII) from Pyrococcus Furiosus. Evidence for the Gating Step in Electron Bifurcation

We have investigated the rapid-reaction kinetics of the NAD+-dependent NADPH:ferredoxin oxidoreductase II (NfnII) from Pyrococcus furiosus, permitting a comparison with recent work done with the paralog NfnI from the same organism. The half-potentials of the electron-bifurcating L-FAD are highly crossed in both NfnI, meaning the potential for the quinone/semiquinone couple is significantly lower than that for the semiquinone/hydroquinone couple so that the semiquinone oxidation state is thermodynamically unstable. The same appears to be the case with NfnII on the basis of its similar behavior in transient absorption spectroscopy experiments and the absence of any evidence for FAD*- accumulation in the course of reductive titrations (which would be manifested as a transient increase in absorbance at ~380 nm)1. Reductive titrations with both the one-electron donor sodium dithionite and the obligate two-electron donor NADPH demonstrate that, in contrast to NfnI, little FADH* accumulates in the high-potential pathway of NfnII in the course of reduction, as reflected in the absence of a transient increase in absorbance in the 500-600 nm region. This indicates that the half-potentials of the S-FAD are crossed in NfnII by a minimum of 120 mV. Rapid-reaction experiments mixing oxidized NfnII with NADPH also show no evidence of S-FADH* accumulation. Furthermore, the enzyme is only partially reduced at the end of the reaction with NADPH, indicating that there is little electron transfer into the high-potential pathway of NfnII. When the reaction is carried out in the presence of the one-electron carrier ferredoxin, only approximately one equivalent of ferredoxin becomes reduced, in contrast to the maximum of three equivalents seen with NfnI. This is consistent with only a single electron bifurcation event taking place under these conditions with NfnII, with only a single high-potential electron passing into the [2Fe-2S] cluster of the high-potential pathway of NfnII but not progressing further to the S-FAD. This accounts for the observation that NfnII has greatly reduced bifurcating activity compared to NfnI. The lack of electron transfer into the S-FAD of NfnII due to its crossed half-potentials prevents successive bifurcation activity and indicates that electron transfer within the high-potential branch gates bifurcation activity in NfnI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of reactive CaCO 3 crystallization in a fluidized bed reactor as a central process of direct air capture

A laboratory-scale, fluidized-bed pellet reactor (BPR) was used to investigate a CaCO 3 crystallization process for the recovery of CO 2 in a Direct Air Capture (DAC) process. The BPR performance was validated against data from a pilot-scale unit. Subsequently, the pellet growth under process-relevant conditions was studied over a period of 144 h. The experimental results with the BPR, containing a bed of pellets sized between 0.65 and 0.84 mm, have shown that a calcium retention of 80% can be achieved at a fluidization velocity of 60 m h -1 and a calcium loading rate of 3 mol h -1 . This result is consistent with calcium retention observed at pilot scale operation and hence, results from the BPR are considered representative for the pilot scale unit. Starting with a bed of pellets sized between 0.15 and 0.5 mm, the average pellet growth rate, G, at the reactor bottom increased from 8.1E-10 to 11E–10 m s -1 at the onset and decreased to 4.9E–10 m s -1 over the course of a 144 h test. The calcium retention over the course the test showed the same trend (initial increase and final decrease) as the pellet growth rate. A theoretical bed growth model was developed and validated against data from the pilot scale and benchtop pellet reactors. The model was used to calculate the bed porosity and total pellet surface area in each control volume. Lastly, the pellet surface area growth at the bottom of the reactor reproduced the pellet growth and retention data trends.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive Radiotherapy for Bladder Cancer—A Systematic Review

Radiotherapy has been offered as a multimodality treatment for bladder cancer patients. Due to the significant variation of bladder volume observed throughout the course of treatment, large margins in the range of 20–30 mm have been used, unnecessarily irradiating a large volume of normal tissue. With the capability of visualizing soft tissue in cone beam computed tomography, there is opportunity to modify or to adapt the plan based on the variation observed during the course of treatment for quality improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformation analysis of SiC-SiC channel box for BWR applications

Silicon carbide fiber-reinforced silicon carbide matrix (SiC-SiC) composites are being considered as components in light water reactor cores to improve accident tolerance, including channel boxes and fuel cladding. In the nuclear reactor environment, core components like a channel box will be exposed to neutron and other radiation damage and temperature gradients. To ensure reliable and safe operation of a SiC-SiC channel box, it is important to assess its deformation behavior under in-reactor conditions including the expected neutron flux and temperature distributions. In particular, this work has evaluated the effect of non-uniform dimensional changes caused by spatially varying neutron flux and temperatures on the deformation behavior of the channel box over the course of one year. These analyses have been performed using the fuel performance modeling code BISON and the commercial finite element analysis code Abaqus, based on fast flux and temperature boundary conditions that have been calculated using the neutronics and thermal-hydraulics codes Serpent and CTF, respectively. The dependence of dimensions and thermophysical properties on fast flux and temperature has been incorporated into the material models. These initial results indicate significant bowing of the channel box with a lateral displacement greater than 6.5 mm. The channel box bowing behavior is time dependent and driven by the temperature dependence of the SiC irradiation-induced swelling and the neutron flux/fluence gradients. The bowing behavior gradually recovers during the course of the operating cycle as the swelling of the SiC-SiC material saturates. Furthermore, the bending relaxation due to temperature gradients does not fully recover and residual bending remains after the swelling saturates in the entire channel box.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CoTiO{sub 3} via cobalt oxalate-TiO{sub 2} precursor. Synthesis and characterization

Purely trigonal ilmenite type powder; CoTiO{sub 3} was successfully synthesized through the thermal decomposition of CoC{sub 2}O{sub 4}{center_dot}2H{sub 2}O-TiO{sub 2} precursor. The decomposition course was followed using differential thermal analysis-thermogravimetry measurements and the intermediate decomposition products as well as the titanate product were characterized using X-ray diffraction, Fourier transform infrared, transmission electron microscopy techniques. Thermal analysis study indicated that, the intermediate decomposition product; Co{sub 3}O{sub 4} decomposed endothermically into CoO at 963 Degree-Sign C with instantaneous formation of CoTiO{sub 3}. X-ray diffraction of the powder calcined at 950 Degree-Sign C showed characteristic lines for Co{sub 2}TiO{sub 4} besides secondary phase of rutile-TiO{sub 2}, which are disappeared by rising the calcination temperature to 1000 Degree-Sign C. Transmission electron microscopy image of CoTiO{sub 3} powder exhibit weak agglomerated particles with heterogeneous morphology in both shape and dimensions. Type II adsorption isotherm estimated using Brunauer-Emmett-Teller procedure indicated a very high specific surface area of 29.7 m{sup 2} g{sup -1}. Electrical properties of CoTiO{sub 3} measured as a function of temperature and frequency showed a semiconducting behavior at high temperatures with conduction activation energy of 0.73 eV. Kinetic analysis of the non-isothermal thermogravimetry curves, using different computational methods, illustrated that the random nucleation and growth mechanisms are the predominant one. - Graphical Abstract: The figure showed the variation of dielectric constant ({epsilon} Prime ) for CoTiO{sub 3} with temperature at different frequencies. {epsilon} Prime appeared to be temperature and frequency independent at low temperatures. By increasing the temperature, the orientation polarization plays a significant role and a gradual increase of {epsilon} Prime occurred. Highlights: Black-Right-Pointing-Pointer CoTiO{sub 3} was synthesized through decomposition of CoC{sub 2}O{sub 4}{center_dot}2H{sub 2}O-TiO{sub 2} precursor. Black-Right-Pointing-Pointer XRD, FT-IR, TEM techniques are used to characterize decomposition course. Black-Right-Pointing-Pointer Specific surface area of 29.7 m{sup 2} g{sup -1} was obtained. Black-Right-Pointing-Pointer The prepared titanate showed semiconducting behavior.

36 MATERIALS SCIENCE↗

Oxidation behaviors of porous Haynes 214 alloy at high temperatures

The oxidation behaviors of porous Haynes 214 alloy at temperatures from 850 to 1000 °C were investigated. The porous alloys before and after the oxidation were examined by optical microscopy, scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) analyses, and X-ray photoelectron spectroscopy (XPS). The oxidation kinetics of the porous alloy approximately follows a parabolic rate law and exhibits two stages controlled by different oxidation courses. Complex oxide scales composed of Cr{sub 2}O{sub 3}, NiCr{sub 2}O{sub 4} and Al{sub 2}O{sub 3} are formed on the oxidized porous alloys, and the formation of Cr{sub 2}O{sub 3} on its outer layer is promoted with the oxidation proceeding. The rough surface as well as the micropores in the microstructures of the porous alloy caused by the manufacturing process provides fast diffusion paths for oxygen so as to affect the formation of the oxide layers. Both the maximum pore size and the permeability of the porous alloys decrease with the increase of oxidation temperature and exposure time, which may limit its applications. - Highlights: • Two-stage oxidation kinetics controlled by different oxidation courses is showed. • Oxide scale mainly consists of Cr{sub 2}O{sub 3}, NiCr{sub 2}O{sub 4} and Al{sub 2}O{sub 3}. • Rough surface and micropores lead to the formation of uneven oxide structure. • Content of Cr{sub 2}O{sub 3} in the outer layer of the scale increases with time at 1000 °C. • Maximum pore size and permeability decrease with increasing temperature and time.

36 MATERIALS SCIENCE↗

Water-inducing molecular self-assembly of amphiphilic molecules into nanofibers

Graphical abstract: TPDP nanofibers with smooth surfaces can be obtained by reprecipitation method using ethanol as good solvent and water as poor solvent. In the self-assembly process, during the water adding to the amphiphilic molecules' saturated solution, the amphiphilic molecules firstly assembled into needle-like small rods. With an increase in the self-assembled time, a large number of the nanofibers are produced. The assembly behavior was revealed in the course of direct in situ monitoring of its growth with optical microscopy. Highlights: Black-Right-Pointing-Pointer 2,3,6,7-Tetramethoxy-9,10-di(4-pyridyl)-9,10-dihydroanthracen (TPDP) was synthesized. Black-Right-Pointing-Pointer TPDP nanofibers can be obtained by reprecipitation method. Black-Right-Pointing-Pointer The assembly behavior was revealed in situ monitoring with optical microscopy. -- Abstract: We present investigations on the microcosmic self-assembly process of new synthesized amphiphilic TPDP molecules. It can be seen that pure TPDP nanofibers with smooth surfaces can be obtained by reprecipitation method using ethanol as good solvent and water as poor solvent. In the self-assembly process, during the water adding to the amphiphilic molecules' saturated solution, the amphiphilic molecules firstly assembled into needle-like small rods. With an increase in the self-assembled time, a large number of the nanofibers are produced. The assembly behavior was revealed in the course of direct in situ monitoring of its growth with optical microscopy. Field emission scanning electron microscopy was adopted to characterize the morphologies of the products.

36 MATERIALS SCIENCE↗

Minimal Benefit of an Endorectal Balloon for Prostate Immobilization as Verified by Daily Localization

We wanted to investigate whether using an endorectal balloon (ERB) in lieu of image guidance is reasonable. We compared daily prostate motion in 2 cohorts of patients with fiducial markers implanted in the prostate, one group with the ERB and the other without. Twenty-nine patients were treated using intensity-modulated radiation therapy: 14 with an ERB, and 15 without. All had fiducial markers placed in the prostate. We reviewed the daily displacements necessary to place the isocenter on the prostate as determined by portal imaging. In addition, we used the data to determine whether there is a change in prostate motion over the treatment course. The average prostate displacement for patients treated without an ERB was slightly greater than the average displacement for patients treated with the ERB. However, the difference observed with the ERB was not statistically significant (p > 0.05). The margins necessary to encompass the prostate 95% of the time for the patients treated without an ERB in the lateral, cranio/caudal, and anterior/posterior dimensions would be 4.8, 12.1, and 15.2 mm, respectively. When using the ERB, the margins necessary would be 4.1, 10.4, and 11 mm, respectively. Prostate motion in the anterior-posterior direction actually increased over the course of treatment in patients without an ERB. This increase was prevented by use of the ERB. Day-to-day variability of the position of the prostate is reduced in all dimensions with the water-filled ERB, but not significantly statistically. Use of the water-filled ERB did not obviate performing some form of image guidance daily.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments

The purpose of this work is to investigate the dosimetric influence of the residual rotational setup errors on head and neck carcinoma (HNC) intensity-modulated radiation therapy (IMRT) with routine 3 translational setup corrections and the adequacy of this routine correction. A total of 66 kV cone beam computed tomography (CBCT) image sets were acquired on the first day of treatment and weekly thereafter for 10 patients with HNC and were registered with the corresponding planning CT images, using 2 3-dimensional (3D) rigid registration methods. Method 1 determines the translational setup errors only, and method 2 determines 6-degree (6D) setup errors, i.e., both rotational and translational setup errors. The 6D setup errors determined by method 2 were simulated in the treatment planning system and were then corrected using the corresponding translational data determined by method 1. For each patient, dose distributions for 6 to 7 fractions with various setup uncertainties were generated, and a plan sum was created to determine the total dose distribution through an entire course and was compared with the original treatment plan. The average rotational setup errors were 0.7°± 1.0°, 0.1°±1.9°, and 0.3°±0.7° around left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. With translational corrections determined by method 1 alone, the dose deviation could be large from fraction to fraction. For a certain fraction, the decrease in prescription dose coverage (V{sub p}) and the dose that covers 95% of target volume (D{sub 95}) could be up to 15.8% and 13.2% for planning target volume (PTV), and the decrease in V{sub p} and the dose that covers 98% of target volume (D{sub 98}) could be up to 9.8% and 5.5% for the clinical target volume (CTV). However, for the entire treatment course, for PTV, the plan sum showed that the average V{sub p} was decreased by 4.2% and D{sub 95} was decreased by 1.2 Gy for the first phase of IMRT with a prescription dose of 50 Gy. For CTV, the plan sum showed that the average V{sub p} was decreased by 0.8% and D{sub 98}, relative to prescription dose, was not decreased. Among these 10 patients, the plan sum showed that the dose to 1-cm{sup 3} spinal cord (D{sub 1cm{sup 3}}) increased no more than 1 Gy for 7 patients and more than 2 Gy for 2 patients. The average increase in D{sub 1cm{sup 3}} was 1.2 Gy. The study shows that, with translational setup error correction, the overall CTV V{sub p} has a minor decrease with a 5-mm margin from CTV to PTV. For the spinal cord, a noticeable dose increase was observed for some patients. So to decide whether the routine clinical translational setup error correction is adequate for this HNC IMRT technique, the dosimetric influence of rotational setup errors should be evaluated carefully from case to case when organs at risk are in close proximity to the target.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental evaluation of actual delivered dose using mega-voltage cone-beam CT and direct point dose measurement

Radiation therapy in patients is planned by using computed tomography (CT) images acquired before start of the treatment course. Here, tumor shrinkage or weight loss or both, which are common during the treatment course for patients with head-and-neck (H and N) cancer, causes unexpected differences from the plan, as well as dose uncertainty with the daily positional error of patients. For accurate clinical evaluation, it is essential to identify these anatomical changes and daily positional errors, as well as consequent dosimetric changes. To evaluate the actual delivered dose, the authors proposed direct dose measurement and dose calculation with mega-voltage cone-beam CT (MVCBCT). The purpose of the present study was to experimentally evaluate dose calculation by MVCBCT. Furthermore, actual delivered dose was evaluated directly with accurate phantom setup. Because MVCBCT has CT-number variation, even when the analyzed object has a uniform density, a specific and simple CT-number correction method was developed and applied for the H and N site of a RANDO phantom. Dose distributions were calculated with the corrected MVCBCT images of a cylindrical polymethyl methacrylate phantom. Treatment processes from planning to beam delivery were performed for the H and N site of the RANDO phantom. The image-guided radiation therapy procedure was utilized for the phantom setup to improve measurement reliability. The calculated dose in the RANDO phantom was compared to the measured dose obtained by metal-oxide-semiconductor field-effect transistor detectors. In the polymethyl methacrylate phantom, the calculated and measured doses agreed within about +3%. In the RANDO phantom, the dose difference was less than +5%. The calculated dose based on simulation-CT agreed with the measured dose within±3%, even in the region with a high dose gradient. The actual delivered dose was successfully determined by dose calculation with MVCBCT, and the point dose measurement with the image-guided radiation therapy procedure.

61 RADIATION PROTECTION AND DOSIMETRY↗

A comprehensive dosimetric study of pancreatic cancer treatment using three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated radiation therapy (VMAT), and passive-scattering and modulated-scanning proton therapy (PT)

With traditional photon therapy to treat large postoperative pancreatic target volume, it often leads to poor tolerance of the therapy delivered and may contribute to interrupted treatment course. This study was performed to evaluate the potential advantage of using passive-scattering (PS) and modulated-scanning (MS) proton therapy (PT) to reduce normal tissue exposure in postoperative pancreatic cancer treatment. A total of 11 patients with postoperative pancreatic cancer who had been previously treated with PS PT in University of Pennsylvania Roberts Proton Therapy Center from 2010 to 2013 were identified. The clinical target volume (CTV) includes the pancreatic tumor bed as well as the adjacent high-risk nodal areas. Internal (iCTV) was generated from 4-dimensional (4D) computed tomography (CT), taking into account target motion from breathing cycle. Three-field and 4-field 3D conformal radiation therapy (3DCRT), 5-field intensity-modulated radiation therapy, 2-arc volumetric-modulated radiation therapy, and 2-field PS and MS PT were created on the patients’ average CT. All the plans delivered 50.4 Gy to the planning target volume (PTV). Overall, 98% of PTV was covered by 95% of the prescription dose and 99% of iCTV received 98% prescription dose. The results show that all the proton plans offer significant lower doses to the left kidney (mean and V{sub 18} {sub Gy}), stomach (mean and V{sub 20} {sub Gy}), and cord (maximum dose) compared with all the photon plans, except 3-field 3DCRT in cord maximum dose. In addition, MS PT also provides lower doses to the right kidney (mean and V{sub 18} {sub Gy}), liver (mean dose), total bowel (V{sub 20} {sub Gy} and mean dose), and small bowel (V{sub 15} {sub Gy} absolute volume ratio) compared with all the photon plans and PS PT. The dosimetric advantage of PT points to the possibility of treating tumor bed and comprehensive nodal areas while providing a more tolerable treatment course that could be used for dose escalation and combining with radiosensitizing chemotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Science of Nuclear Materials: A Modular, Laboratory-based Curriculum

The development of a curriculum for nuclear materials courses targeting students pursuing Master of Arts degrees at The George Washington University is described. The courses include basic concepts such as radiation and radioactivity as well as more complex topics such the nuclear fuel cycle, nuclear weapons, radiation detection and technological aspects of non-proliferation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗