Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Design of the solar X-ray instrument for OSO-H.

The OSO-H solar X-ray instrument monitors X rays from the sun in the energy range 1-300 keV, as well as the charged particle background. The electronics provide accurate logarithmic pulse-height analysis at the high counting rates expected under flare conditions. A high time resolution mode enables tudy the temporal development of a solar flare.

Harrington, T. M.↗

Thermospheric temperature measurement technique.

A method for measurement of temperature in the earth's lower thermosphere from a high-velocity probes is described. An undisturbed atmospheric sample is admitted to the instrument by means of a free molecular flow inlet system of skimmers which avoids surface collisions of the molecules prior to detection. Measurement of the time-of-flight distribution of an initially well-localized group of nitrogen metastable molecular states produced in an open, crossed electron-molecular beam source, yields information on the atmospheric temperature. It is shown that for high vehicle velocities, the time-of-flight distribution of the metastable flux is a sensitive indicator of atmospheric temperature. The temperature measurement precision should be greater than 94% at the 99% confidence level over the range of altitudes from 120-170 km. These precision and altitude range estimates are based on the statistical consideration of the counting rates achieved with a multichannel analyzer using realistic values for system parameters.

Hueser, J. E.↗

A liquid xenon radioisotope camera.

A new type of gamma-ray camera is discussed that makes use of electron avalanches in liquid xenon and is currently under development. It is shown that such a radioisotope camera promises many advantages over any other existing gamma-ray cameras. Spatial resolution better than 1 mm and counting rates higher than one million C/sec are possible. An energy resolution of 11% FWHM has recently been achieved with a collimated Hg-203 source using a parallel-plate ionization chamber containing a Frisch grid.

Zaklad, H.↗

Improved format for radiocardiographic data

Technique involves introduction of radioactive sample into antecubital vein. Scintillation crystal mounted in collimating housing views portion of right and left hearts. As radioactive sample passes through heart, counting rate is measured by crystal and recorded on strip chart. Data is insensitive to geometric effects and other parameters.

Dimeff, J.↗

Counter tube window and X-ray fluorescence analyzer study

A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.

Hertel, R.↗

The diffuse X-ray spectrum from 14-200 keV as measured on OSO-5

The measurement of energy spectrum of the diffuse component of cosmic X-ray flux made on the OSO-5 spacecraft is described. The contributions to the total counting rate of the actively shielded X-ray detector are considered in some detail and the techniques used to eliminate the non-cosmic components are described. Positive values for the cosmic flux are obtained in seven energy channels between 14 and 200 keV and two upper limits are obtained between 200 and 254 keV. The results can be fitted by a power law spectrum. A critical comparison is made with the OSO-3 results. Conclusions show that the reported break in the energy spectrum at 40 keV is probably produced by an erroneous correction for the radioactivity induced in the detector on each passage through the intense charged particle fluxes in the South Atlantic anomaly.

Dennis, B. R.↗

Intensity Oscillation of Low Energy Solar Particles Observed on the IMP 7 Satellite

Solar flare particles in the energy range from 125 to 160 KeV per charge were detected and analyzed by an electrostatic deflection vs. energy instrument on board the Explorer 47 (IMP 7) satellite. A harmonic analysis of the counting rates shows that frequently, the fluctuation of the particle flux can be approximately represented by N(t) = f(t)sin 2 pi nu t where f(t) is a smoothly varying function of t. The oscillation frequency nu varies from flare to flare and is of the order of 2 x .001/sec. The physical implications of the finding are discussed.

Fan, C. Y.↗

A first look at the lunar orbital gamma-ray data.

Preliminary review of data from the radioactivity relief map of the regions of the moon overflown by the Apollo 15 command module. The data represent count rates in the energy band from 0.55 to 2.75 MeV, appropriately corrected and averaged. Review results include the findings that: (1) the major concentrations of radioactivity in the area covered are in the region of Mare Imbrium and Oceanus Procellarum, (2) the highest regions are in the area of Aristarchus in Oceanus Procellarum and a region in eastern Mare Imbrium, and (3) the K/U ratio appears to be lower everywhere than that characteristic of the earth.-

Metzger, A. E.↗

Observations of the binary X-ray source SMC X-1 from OSO-7.

The X-ray source was observed with an X-ray telescope during the time from April 15, 1972 to May 25, 1972. These observations complement the Uhuru results reported by Schreier et al. (1972) and permit an extension of the spectrum to at least 35 keV. Combined with other observations, the data could help determine long term periodic variations, if any exist. The relative exposure and the corrected counting rate of the X-ray telescope during the precession of the satellite axis are shown in a graph.

Ulmer, M. P.↗

Upper limit to the 1-20 MeV solar neutron flux.

The upper limit on the quiet time solar neutron flux from 1 to 20 MeV has been measured to be less than .002 neutrons at the 95% confidence level. This result is deduced from the OGO-6 neutron detector measurements of the 'day-night' effect near the equator at low altitudes for the period from June 7 to Dec. 23, 1969. The OGO-6 detector had very low (less than 4%) counting rate contributions from locally produced neutrons in the detecting system and the spacecraft and from charged-particle interactions in the neutron sensor.

Lockwood, J. A.↗

Anisotropic detector system for the measurement of gamma-ray source position

Detection efficiencies of cylindrical detectors for various gamma ray photon angular distributions in the energy range from .10 MeV to 15 MeV are studied. It was found that a properly chosen cylindrical crystal can produce a significantly modulated count rate as a function of angle when rotated in the anisotropic flux, The studies further indicate that simple detector systems can be used on small satellites for the determination of a gamma ray source position. Results are outlined and extended to examine source resolution angles for a practical size detector.

Trombka, J. I.↗

The geographical distribution of difference 100-keV electrons above the earth's atmosphere

Modern soft X-ray astronomical observations are made with large-area proportional counters that have very thin plastic windows. The counters are consequently very sensitive to low energy electrons. An electron with only a few keV of energy can penetrate a typical window, and a flux of approximately 100 electrons per square centimeter sec-ster can double the background counting rate during a typical observation. These electrons produce an undersiable effect which, is impossible to distinguish from X ray data. Consequently, an electron-free region is needed for accurate astronomical observations. Geographical regions of weak electron flux from low altitude satellite data are derived. These regions can be compared with the locations of rocket launching sites. The best sites should be those farthest from electron regions.

Seward, F. D.↗

The particle background observed by the X-ray detectors onboard Copernicus

The design and characteristics of low energy detectors on the Copernicus satellite are described. The functions of the sensors in obtaining data on the particle background. The procedure for processing the data obtained by the satellite is examined. The most significant positive deviations are caused by known weak X-ray sources in the field of view. In addition to small systemic effects, occasional random effects where the count rate increases suddenly and decreases within a few frames are analyzed.

Davison, P. J. N.↗

Study on the effect of contamination on the performance of X-ray telescopes

Modifications were made to the X-ray reflectometer located at the Space Sciences Laboratory, Marshall Space Flight Center. One was an automatic drive for the Large Micrometer Head. This system, interfaced with the Hewlett Packard Computer System, is used to record data and provides the X-ray reflectometer with an automated data-taking capability. Using this system, a complete scatter curve can be obtained automatically. Previously, it was necessary to manually reset the system after recording for each data point in the scatter curve. The second modification provided an externally controlled electrical drive to move the microfocus X-ray source along its axis. With this modification, one can translate the X-ray source while it is operating to locate the position providing maximum count rate.

Neal, W. R.↗

Analysis of the 0.511 MeV radiation at the OSO-7 satellite

Observations of the 0.511 MeV positron annihilation, gamma ray on the OSO-7 satellite are presented. Variables which affect the counting rate are discussed. An upper limit flux of .0076 photons/sq cm/sec is obtained for the quiet sun and a positive solar flux of .063(+ or - .0002) photons/sq cm/sec is obtained for the 3B flare of 4 August 1972. The width of this annihilation line gives an upper limit temperature for the annihilation region of approximately 6 million K. An analysis of the line width and position also shows that the contribution to the line from positronium annihilation is less than 100% at the 99% confidence level. An upper limit is also found for an isotropic cosmic flux.

Dunphy, P. P.↗

The diffuse X-ray spectrum from 14 to 200 keV as measured on OSO-5

Evaluation of OSO-5 measurements of the energy spectrum of the diffuse component of the cosmic X-ray flux in the energy range from 14 to 200 keV. A detailed description is given of the X-ray detector employed and of the method of selection and pulse-height analysis of X-ray events. The method employed in eliminating noncosmic X-ray contributions to the total counting rate is discussed. The final energy spectrum is found to be best fitted by a power law which is in essential agreement with that obtained from OSO-3 by Schwartz et al. (1970), in spite of what is regarded as an erroneous correction procedure used by them. In particular, it is suggested that the break in the energy spectrum at 40 keV which they reported may have been produced by an erroneous correction for the radioactivity induced in the detector during each passage through the intense charged-particle fluxes in the South Atlantic Anomaly.

Dennis, B. R.↗

Spectrum of atmospheric gamma rays to 10 MeV at lambda = 40 deg

Results of measurements of the differential counting rate spectra due to atmospheric gamma rays as a function of altitude to 3.6 g/sq cm over Texas. Two gain settings and a 128-channel pulse height analyzer were used to cover the range from 0.2 to 10 MeV. The detector was a 7.6 x 7.6 cm NaI crystal, which was surrounded on five sides by a 2-cm-thick plastic anticoincidence shield for charged particle rejection. The system had a nearly isotropic response to photons above 0.2 MeV. The spectrum at ceiling appeared as a steep continuum with a power-law index of about 1.4. The only obvious feature was the 0.51-MeV positron annihilation line. The spectral shape was independent for depths less than 20 g/sq cm, the absolute intensity varying in proportion to the intensity of the cosmic ray secondary charged particles. Also, at depths less than 30 g/sq cm the observed flux variation with altitude can be described in terms of an empirical depth-dependent source function.

Peterson, L. E.↗

Intensity oscillation of low energy solar particles observed on the IMP 7 satellite

Solar flare particles in the energy range from 125 to 160 KeV per charge were detected and analyzed by an electrostatic deflection vs energy instrument on board the Explorer 47 (IMP 7) satellite. On the basis of a harmonic analysis of the counting rates, an approximating formula is obtained for the fluctuation of the particle flux. The oscillation frequency varies from flare to flare and is of the order of approximately .002 per sec. The physical implications of the finding are discussed.

Fan, C. Y.↗