Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSED AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Reorganization of Water at Aqueous Aluminum Chloride (AlCl 3 ) Interfaces: Vibrational Sum Frequency Generation and Molecular Dynamics Simulations

AlCl 3 hydration states and complexation are not well understood both in solutions and at the air–aqueous interface despite their potential significance in natural waters and their industrial and energy-related applications. Here, we investigated Al 3+ and Cl – ion behaviors in an AlCl 3 aqueous bulk solution and at the air–aqueous interface using interface-selective vibrational sum frequency generation (SFG), Raman and infrared spectroscopies, molecular dynamics (MD) simulation, as well as molecular-informed reduced modeling. Our reduced modeling reveals relatively long-range effects for Al 3+ as compared to monovalent ions such as Na + indicating that the interfacial depth of trivalent ions can be significantly larger than that of monovalent ions at the air–water interface. MD simulations reveal interfacial stratification and multiple layering of the ions. Compression of the Al 3+ and Cl – distributions with increasing concentrations from 0.5 to 2.5 m is also observed in the subsurface regions. Significant SSP- and PPP-polarized SFG OH spectral intensity increases are observed from 0.5 to 1.5 m and 0.5 to 2.5 m, respectively, indicative of interfacial depth increases and a change in average orientation above 1.5 m. Extensive evaluation of SFG spectra, Fresnel-corrected using several approaches, shows the same trends. The nonmonotonic trend points to a changing structure in surface and subsurface water orientation and hydrogen bonding environment generally consistent with the MD simulation of stratification and water orientation changes. Furthermore, solvent-shared ion pairing is implicated with MD simulation radial distribution analysis and consistent with infrared spectral identification of the hexaaqua aluminum ion in the solution phase. Spectral evidence of a strong Al 3+ hydration shell and the acidic behavior of the Al 3+ ions is obvious in the Raman and infrared spectra of the bulk solution. In conclusion, we show that the MD dipole potential is directly related to the MD second-order susceptibility of the interface, χ SFG–MD (2) , both of which correlate up to ∼35 Å with the spectral observations of increasing and then saturating intensities, suggesting that both ion stratification and interfacial depth determine the water orientations at an air–water interface of 1-3 electrolyte solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-190: Development of Abdominal Compression & Respiratory Guiding System Using Gas Pressure Sensor

Purpose: Abdominal compression is known to be effective but, often makes external-marker-based monitoring of breathing motion not feasible. In this study, we developed and evaluated a system that enables both abdominal compression and monitoring of residual abdominal motion simultaneously. The system can also provide visual-biofeedback capability. Methods: The system developed consists of a compression belt, an abdominal motion monitoring sensor (gas pressure sensor) and a visual biofeedback device. The compression belt was designed to be able to compress the frontal side of the abdomen. The pressure level of the belt is controlled by air volume and monitored in real time using the gas pressure sensor. The system displays not only the real-time monitoring curve but also a guiding respiration model (e.g., a breath hold or shallow breathing curve) simultaneously on the head mounted display to help patients keep their breathing pattern as consistent as possible. Three healthy volunteers were enrolled in this pilot study and respiratory signals (pressure variations) were obtained both with and without effective abdominal compression to investigate the feasibility of the developed system. Two guidance patterns, breath hold and shallow breathing, were tested. Results: All volunteers showed smaller abdominal motion with compression (about 40% amplitude reduction compared to without compression). However, the system was able to monitor residual abdominal motion for all volunteers. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed abdominal compression & respiratory guiding system was feasible for residual abdominal motion management. It is considered that the system can be used for a respiratory motion involved radiation therapy while maintaining the merit of abdominal compression. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

Long-Duration Testing of a Temperature-Swing Adsorption Compressor for Carbon Dioxide for Closed-Loop Air Revitalization Systems

This paper describes the results of long-duration testing of a temperature-swing adsorption compressor that has application in the International Space Station (ISS) and future spacecraft for closing the air revitalization loop. The air revitalization system of the ISS operates in an open loop mode and relies on the resupply of oxygen and other consumables from Earth for the life support of astronauts. A compressor is required for delivering the carbon dioxide from a removal assembly to a reduction unit to recover oxygen and thereby closing the air-loop. The TSAC is a solid-state compressor that has the capability to remove CO2 from a low-pressure source, and subsequently store, compress, and deliver at a higher pressure as required by a processor. The TSAC is an ideal interface device for CO2 removal and reduction units in the air revitalization loop of a spacecraft for oxygen recovery. The TSAC was developed and its operation was successfully verified in integration tests with the flight-like Carbon Dioxide Removal Assembly (CDRA) at Marshall Space Flight Center prior to the long-duration tests. Long-duration tests reveal the impacts of repeated thermal cycling on the compressor components and the adsorbent material.

Rosen, Micha↗

Propane vehicles : status, challenges, and opportunities.

Propane as an auto fuel has a high octane value and has key properties required for spark-ignited internal combustion engines. To operate a vehicle on propane as either a dedicated fuel or bi-fuel (i.e., switching between gasoline and propane) vehicle, only a few modifications must be made to the engine. Until recently propane vehicles have commonly used a vapor pressure system that was somewhat similar to a carburetion system, wherein the propane would be vaporized and mixed with combustion air in the intake plenum of the engine. This leads to lower efficiency as more air, rather than fuel, is inducted into the cylinder for combustion (Myers 2009). A newer liquid injection system has become available that injects propane directly into the cylinder, resulting in no mixing penalty because air is not diluted with the gaseous fuel in the intake manifold. Use of a direct propane injection system will improve engine efficiency (Gupta 2009). Other systems include the sequential multi-port fuel injection system and a bi-fuel 'hybrid' sequential propane injection system. Carbureted systems remain in use but mostly for non-road applications. In the United States a closed-loop system is used in after-market conversions. This system incorporates an electronic sensor that provides constant feedback to the fuel controller to allow it to measure precisely the proper air/fuel ratio. A complete conversion system includes a fuel controller, pressure regulator valves, fuel injectors, electronics, fuel tank, and software. A slight power loss is expected in conversion to a vapor pressure system, but power can still be optimized with vehicle modifications of such items as the air/fuel mixture and compression ratios. Cold start issues are eliminated for vapor pressure systems since the air/fuel mixture is gaseous. In light-duty propane vehicles, the fuel tank is typically mounted in the trunk; for medium- and heavy-duty vans and trucks, the tank is located under the body of the vehicle. Propane tanks add weight to a vehicle and can slightly increase the consumption of fuel. On a gallon-to-gallon basis, the energy content of propane is 73% that of gasoline, thus requiring more propane fuel to travel an equivalent distance, even in an optimized engine (EERE 2009b).

02 PETROLEUM↗

Pulsating one-dimensional detonation in ammonia-hydrogen–air mixtures

In this study, one-dimensional detonations in ammonia/hydrogen-air mixtures are numerically investigated by solving the fully compressible Navier-Stokes equations with detailed chemistry. Pulsating instabilities with single-mode are observed during the detonation wave propagation, accompanied by periodic coupling and decoupling of the lead shock wave and the reactive front. The ratio between driver pressure and initial pressure determines the overdrive degree and thus the oscillatory mode of detonation for a premixture with certain composition. The effects of hydrogen dilution and mixture equivalence ratio on pulsating detonations are also examined under a constant driver pressure. The growing hydrogen fraction in fuel blends significantly increases the oscillation frequency. In addition, the pulsating detonation frequency rises with increasing equivalence ratio under fuel-lean conditions, peaks under stoichiometric conditions, and falls under fuel-rich conditions as the equivalence ratio increases further. Evolutions of reactants, main intermediate radicals, and products are analysed in both fuel-lean and fuel-rich conditions. A chemical explosive mode analysis further confirms the highly-autoignitive nature of the mixture in the induction zone between reaction front and shock front where thermal diffusion plays a negligible role.

08 HYDROGEN↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Multiphase CFD-based models for chemical looping combustion process: Fuel reactor modeling

Chemical looping combustion (CLC) is a flameless two-step fuel combustion that produces a pure CO2 stream, ready for compression and sequestration. The process is composed of two interconnected fluidized bed reactors. The air reactor which is a conventional circulating fluidized bed and the fuel reactor which is a bubbling fluidized bed. The basic principle is to avoid the direct contact of air and fuel during the combustion by introducing a highly-reactive metal particle, referred to as oxygen carrier, to transport oxygen from the air to the fuel. In the process, the products from combustion are kept separated from the rest of the flue gases namely nitrogen and excess oxygen. This process eliminates the energy intensive step to separate the CO2 from nitrogen-rich flue gas that reduce the thermal efficiency. Fundamental knowledge of multiphase reactive fluid dynamic behavior of the gas–solid flow is essential for the optimization and operation of a chemical looping combustor. Our recent thorough literature review shows that multiphase CFD-based models have not been adapted to chemical looping combustion processes in the open literature. In this study, we have developed the reaction kinetics model of the fuel reactor and implemented the kinetic model into a multiphase hydrodynamic model, MFIX, developed earlier at the National Energy Technology Laboratory. Simulated fuel reactor flows revealed high weight fraction of unburned methane fuel in the flue gas along with CO2 and H2O. This behavior implies high fuel loss at the exit of the reactor and indicates the necessity to increase the residence time, say by decreasing the fuel flow rate, or to recirculate the unburned methane after condensing and removing CO2.

03 NATURAL GAS↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Equivalent Mass Benefits from Employing Vapor Compression Refrigeration on Spacecraft

Thermoelectric cooling, reversed Brayton cycles and Stirling cycle devices are common cooling technologies employed on spacecraft where temperatures below the radiator temperature are needed. Although used less often in microgravity, vapor compression refrigeration was proposed for microgravity applications as early as the 1970s. Researchers proposed the vapor compression cycle over other cooling technologies for its superior energy efficiency in the typical refrigerator/freezer and air-conditioning temperature range. The higher energy efficiency should alleviate the mass penalty of the thermal system, conceivably both for satellites and manned spacecraft. Despite numerous propositions, the literature lacks a discussion of the absolute equivalent mass benefit achievable and the value of it relative to the total mass of the thermal system of the spacecraft or the spacecraft itself. This paper presents the equivalent mass benefits of employing a vapor compression system over other cooling technologies using a mass penalty factor for power consumption. Additionally, a prototype vapor compression cooler sized to fit into an ISS locker is presented.

refrigerator↗

Splanchnic Compression Improves the Efficacy of Compression Stockings to Prevent Orthostatic Intolerance

Purpose: Post-spaceflight orthostatic intolerance (OI) is observed in 20-30% of astronauts. Previous data from our laboratory suggests that this is largely a result of decreased venous return. Currently, NASA astronauts wear an anti-gravity suit (AGS) which consists of inflatable air bladders over the calves, thighs and abdomen, typically pressurized from 26 to 78 mmHg. We recently determined that, thigh-high graded compression stockings (JOBST , 55 mmHg at ankle, 6 mmHg at top of thigh) were effective, though to a lesser degree than the AGS. The purpose of this study was to evaluate the addition of splanchnic compression to prevent orthostatic intolerance. Methods: Ten healthy volunteers (6M, 4F) participated in three 80 head-up tilts on separate days while (1) normovolemic (2) hypovolemic w/ breast-high compression stockings (BS)(JOBST(R), 55 mmHg at the ankle, 6 mmHg at top of thigh, 12 mmHg over abdomen) (3) hypovolemic w/o stockings. Hypovolemia was induced by IV infusion of furosemide (0.5 mg/kg) and 48 hrs of a low salt diet to simulate plasma volume loss following space flight. Hypovolemic testing occurred 24 and 48 hrs after furosemide. One-way repeated measures ANOVA, with Bonferroni corrections, was used to test for differences in blood pressure and heart rate responses to head-up tilt, stand times were compared using a Kaplan-Meyer survival analysis. Results: BS were effective in preventing OI and presyncope in hypovolemic test subjects ( p = 0.015). BS prevented the decrease in systolic blood pressure seen during tilt in normovolemia (p < 0.001) and hypovolemia w/o countermeasure (p = 0.005). BS also prevented the decrease in diastolic blood pressure seen during tilt in normovolemia (p = 0.006) and hypovolemia w/o countermeasure (p = 0.041). Hypovolemia w/o countermeasure showed a higher tilt-induced heart rate increase (p = 0.022) than seen in normovolemia; heart rate while wearing BS was not different than normovolemia (p = 0.353). Conclusion: BS may be an effective countermeasure to post-space flight OI. The addition of splanchnic compression is more effective than the previous thigh-high garments. These stockings are readily available, inexpensive, and can be worn for days following landing as astronauts re-adapt to Earth gravity.

Platts, Steven H.↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗

New Thermochemical Salt Hydrate System for Energy Storage in Buildings

This paper introduces an innovative design for an “inorganic salt-expanded graphite” composite thermochemical system. The storage unit is made of a perforated, compressed, expanded graphite block impregnated with molten CaCl 2 ∙6H 2 O; the humid air passes through the holes that allow the moisture to diffuse and react with the salt. The prepared block underwent 90 hydration-dehydration cycles. Although most of the performed cycles were carried out with salt overhydration and deliquescence, the treated samples have remained mechanically and thermally stable with no drop in energy density. The volumetric energy density of the composite ranged from 135.5 to 277.6 kWh/m 3 , depending on airflow rate and absolute humidity. To ensure composite material cycling stability, the energy density of the block was measured during hydration at similar conditions of absolute humidity, inlet temperature, and airflow rate (0.01 kg water /kg air , 20 °C, 400 l/min). The average energy density at these conditions was sustained at 219 kWh/m 3 . The block integrity was monitored by visual inspection after removing it from the reactor chamber every few cycles. Both the composite material and its manufacturing process are simple and easy to scale up for future commercialization.

25 ENERGY STORAGE↗

A unified planar measurement technique for compressible flows using laser-induced iodine fluorescence

A unified laser-induced fluorescence technique for conducting planar measurements of temperature, pressure and velocity in nonreacting, highly compressible flows has been developed, validated and demonstrated. Planar fluorescence from iodine, seeded into air, was induced by an argon-ion laser and collected using a liquid-nitrogen cooled CCD camera. In the measurement technique, temperature is determined from the fluorescence induced with the laser operated broad band. Pressure and velocity are determined from the shape and position of the fluorescence excitation spectrum which is measured with the laser operated narrow band. The measurement approach described herein provides a means of obtaining accurate, spatially-complete maps of the primary flow field parameters in a wide variety of cold supersonic and transonic flows.

Hartfield, Roy J., Jr.↗

A non-linearly stable implicit finite element algorithm for hypersonic aerodynamics

A generalized curvilinear coordinate Taylor weak statement implicit finite element algorithm is developed for the two-dimensional and axisymmetric compressible Navier-Stokes equations for ideal and reacting gases. For accurate hypersonic simulation, air is modeled as a mixture of five perfect gases, i.e., molecular and atomic oxygen and nitrogen as well as nitric oxide. The associated pressure is then determined via Newton solution of the classical chemical equilibrium equation system. The directional semidiscretization is achieved using an optimal metric data Galerkin finite element weak statement, on a developed 'companion conservation law system', permitting classical test and trial space definitions. Utilizing an implicit Runge-Kutta scheme, the terminal algorithm is then nonlinearly stable, and second-order accurate in space and time on arbitrary curvilinear coordinates. Subsequently, a matrix tensor product factorization procedure permits an efficient numerical linear algebra handling for large Courant numbers. For ideal- and real-gas hypersonic flows, the algorithm generates essentially nonoscillatory numerical solutions in the presence of strong detached shocks and boundary layer-inviscid flow interactions.

Iannelli, G. S.↗

Relation of Hydrogen and Methane to Carbon Monoxide in Exhaust Gases from Internal-Combustion Engines

The relation of hydrogen and methane to carbon monoxide in the exhaust gases from internal-combustion engines operating on standard-grade aviation gasoline, fighting-grade aviation gasoline, hydrogenated safety fuel, laboratory diesel fuel, and auto diesel fuel was determined by analysis of the exhaust gases. Two liquid-cooled single-cylinder spark-ignition, one 9-cylinder radial air-cooled spark-ignition, and two liquid-cooled single-cylinder compression-ignition engines were used.

Gerrish, Harold C↗

A Study of Air Flow in an Engine Cylinder

A 4-stroke-cycle test engine was equipped with a glass cylinder and the air movements within it were studied while the engine was being motored. Different types of air flow were produced by using shrouded intake valves in various arrangements and by altering the shape of the intake-air passage in the cylinder head. The air movements were made visible by mixing feathers with the entering air, and high-speed motion pictures were taken of them so that the air currents might be studied in detail and their velocities measured. Motion pictures were also taken of gasoline sprays injected into the cylinder on the intake stroke. The photographs showed that: a wide variety of induced air movements could be created in the cylinder; the movements always persisted throughout the compression stroke; and the only type of movement that persisted until the end of the cycle was rotation about the cylinder axis.

Lee, Dana W↗

Metronome Use for Coordination of Breaths and Cardiac Compressions Delivered by Minimally-Trained Caregivers During Two-Person CPR

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training over 18 months before each mission, including two-person cardiopulmonary resuscitation (2CPR) as recommended by the American Heart Association (AHA). Recent studies have concluded that the use of metronomic tones improves the coordination of 2CPR by trained clinicians. 2CPR performance data for minimally-trained caregivers has been limited. The goal of this study was to determine whether use of a metronome by minimally-trained caregivers (CMO analogues) would improve 2CPR performance. 20 pairs of minimally-trained caregivers certified in 2CPR via AHA guidelines performed 2CPR for 4 minutes on an instrumented manikin using 3 interventions: 1) Standard 2CPR without a metronome [NONE], 2) Standard 2CPR plus a metronome for coordinating compression rate only [MET], 3) Standard 2CPR plus a metronome for coordinating both the compression rate and ventilation rate [BOTH]. Caregivers were evaluated for their ability to meet the AHA guideline of 32 breaths-240 compressions in 4 minutes. All (100%) caregivers using the BOTH intervention provided the required number of ventilation breaths as compared with the NONE caregivers (10%) and MET caregivers (0%). For compressions, 97.5% of the BOTH caregivers were not successful in meeting the AHA compression guideline; however, an average of 238 compressions of the desired 240 were completed. None of the caregivers were successful in meeting the compression guideline using the NONE and MET interventions. This study demonstrates that use of metronomic tones by minimally-trained caregivers for coordinating both compressions and breaths improves 2CPR performance. Meeting the breath guideline is important to minimize air entering the stomach, thus decreasing the likelihood of gastric aspiration. These results suggest that manifesting a metronome for the ISS may augment the performance of 2CPR on orbit and thus may increase the level of care.

Hurst, Victor, IV↗

Capabilities and History of NASA Marshall Space Flight Center's Hydrogen Test Facility

The Hydrogen Test Facility (HTF) has conducted mechanical testing for aerospace materials at NASA's Marshall Space Flight Center for many years. One of the first facilities of its kind to run high-pressure cryogenic permeability tests in liquid hydrogen, HTF is now characterized as a unique national resource capable of overcoming hazardous conditions to perform tests directly in various hydrogen environments. At HTF, custom test systems are operated in eight structurally reinforced test cells from 0 to 68,948 kPa (0 to 10,000 psi) at -253 to 982 C (--423 to 1800 F) in hydrogen, air, helium, and nitrogen, with other environments available upon request. Standard mechanical procedures include compression, fatigue crack growth rate, four-point bend, high/low cycle fatigue, fracture toughness, shear, strain-to-crack, and tensile testing. Cryogenic permeability and thermal conductivity and gaseous creep testing are offered, as well as simulated service under different combinations of operating environment(s), stress, pressure, and ambient-to-extreme temperatures. Advanced tests are routinely developed upon demand, and special component testing is also available. Current efforts include the renovation of two high-pressure gaseous test cells to generate data for a J-2X engine designed for Constellation's Ares I and V vehicles. In the past, HTF has supported other critical NASA programs, such as Apollo, Space Shuttle, and Next Generation Launch Technologies. During the 1990's, hundreds of tests were conducted in liquid hydrogen and liquid nitrogen during development of the Space Shuttle's super lightweight tank, which provided the thrust required to achieve low Earth orbit for the International Space Station. This facility was designed and built in 1963. Originally called the Low Temperature Test Facility, it became known as the Cryogenic Test Facility in the late 1980's and HTF in the early 1990's.

Malone, T. W.↗