Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

HOM Choice Study with Test Electronics for use as Beam Position Diagnostics in 3.9 GHz Accelerating Cavities in FLASH

Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated spectrum have revealed several options: cavity modes with strong coupling to the beam, and therefore with the potential for better position resolution, but which are propagating within all 4 cavities, and modes localized in the cavities or the beam pipes, which can give localized position information, but which provide worse resolution. For a better characterization of these options, a set of test electronics has been built, which can down-convert various frequencies between about 4 and 9 GHz to 70 MHz. The performance of various 20 MHz bands has been estimated. The best resolution of 20 \mu m was found for some propagating modes. Based on this study one band at ca. 5 GHz was chosen for high resolution position monitoring and a band at ca. 9 GHz for localized monitoring.

43 PARTICLE ACCELERATORS↗

Analytical & Experimental Study of Radio Frequency Cavity Beam Profile Monitor

The purpose of this analytical and experimental study is multifold: 1) To explore a new, radiation-robust, hadron beam profile monitor for intense neutrino beam applications; 2) To test, demonstrate, and develop a novel gas-filled Radio-Frequency (RF) cavity to use in this monitoring system. Within this context, the first section of the study analyzes the beam distribution across the hadron monitor as well as the ion-production rate inside the RF cavity. Furthermore a more effecient pixel configuration across the hadron monitor is proposed to provide higher sensitivity to changes in beam displacement. Finally, the results of a benchtop test of the tunable quality factor RF cavity will be presented. The proposed hadron monitor configuration consists of a circular array of RF cavities located at a radial distance of 7cm { corresponding to the standard deviation of the beam due to scatering { and a gas-filled RF cavity with a quality factor in the range 400 - 800.

43 PARTICLE ACCELERATORS↗

Method of increasing power within an optical cavity with long path lengths

A cavity-enhanced absorption spectroscopy instrument has an optical cavity with two or more cavity mirrors, one mirror of which having a hole or other aperture for injecting a light beam, and the same or another mirror of which being partially transmissive to allow exit of light to a detector. A spherical-spherical configuration with at least one astigmatic mirror or a spherical-cylindrical configuration where the spherical mirror could also be astigmatic prevents a reentrant condition wherein the injected beam would prematurely exit the cavity through the aperture. This combination substantially increases the number of passes of the injected beam through a sample volume for sensitive detection of chemical species even in less than ideal conditions including low power laser or LED sources, poor mirror reflectivity or detector noise at the wavelengths of interest, or cavity alignment issues such as vibration or temperature and pressure changes.

47 OTHER INSTRUMENTATION↗

The FNAL Booster 2nd Harmonic RF Cavity

A second harmonic RF cavity which uses perpendicularly biased garnet for frequency tuning is currently being constructed for use in the Fermilab Booster. The cavity will operate at twice the fundamental RF frequency, from ~76 - 106 MHz, and will be turned on only during injection, and transition or extraction. Its main purpose is to reduce beam loss as required by Fermilab’s Proton Improvement Plan (PIP). After three years of optimization and study, the cavity design has been finalized and all constituent parts have been received. We discuss the design aspects of the cavity and its associated systems, component testing, and status of the cavity construction.

43 PARTICLE ACCELERATORS↗

Data Acquisition System for RF Cavity Hadron Monitor

As Fermilab pursues intensity frontier physics, the conventional detectors are not up to the challenge of higher radiation exposure. The detectors in the NuMI beamline rely on knowing the beam composition in order to infer properties of the resultant neutrino beam. Anovel gas-filled RF cavity beam detector is proposed that will be simple and radiation robust in high-radiation environments. Charged particles passing through the cavity produce ionized plasma, which changes the permittivity of the gas and modulate the stored RF field in the cavity. The recent preliminary beam result demonstrates the proof of principle of the beam detector. In an effort to acquire a large amount of data for various cavity parameters, an automatic data acquisition(DAQ)system is designed in LabVIEW. The DAQ system utilizes a Real-Time Power meter from Boonton to acquire RF power data from the cavity.

43 PARTICLE ACCELERATORS↗

Radio frequency tuning of dressed multicell cavities using pressurized balloons

Methods and systems for non-invasively tuning dressed multicell cavities. A multicell cavity can be plastically deformed as result of introducing a customized balloon to a cavity and then pressurizing the balloon to a targeted cell while applying a global force on the cavity flanges. The pressurized balloons localize the plastic deformation to the targeted cells using prescribed values of both global force and balloon pressure. Such an approach allows for the tuning of dressed cavities without removal of the helium vessel.

43 PARTICLE ACCELERATORS↗

Cavity Procurement and Qualification Plan for LCLS-II

The LCLS-II project aims to build 35 accelerating cryomodules, which are based on the European XFEL design but modified for operation in CW mode. Each cryomodule houses eight TESLA-style nine-cell superconducting radio-frequency cavities. The activities to assemble the first two prototype cryomodules are ongoing at FNAL and JLab. 264 cavities worth of cavities for the remaining 33 cryomodules will be procured from two industrial vendors in similar quantity considering the option to produce spares. The assembly of cavities into the production cryomodules will be distributed among FNAL (16 cryomodules) and JLab (17 cryomodules). In this paper the cavity procurement and qualification plan for the LCLS-II project is detailed.

Marhauser, Frank↗

First Test Results of Superconducting Twin Axis Cavity for ERL Applications

Superconducting cavities with two beam pipes had been proposed in the past for energy recovery linac applications. The relatively complex geometry of those cavities presented a serious challenge for fabrication and surface processing. Main concerns have now been overcome with the production and successful RF testing of a new elliptical twin-axis cavity proposed by Jefferson Lab and optimized by the Center for Accelerator Science at Old Dominion University in the frame of a DoE accelerator stewardship program. The cavity design provides uniform accelerating or decelerating fields for both beams. This paper describes the cavity design, fabrication experience, and the first cold RF test results and explores potential applications especially for Jefferson Lab s EIC (JLEIC).

Park, H.-K.↗

A simple variable coupler for the cryogenic test of SRF cavities

The cryogenic rf tests of SRF cavities in vertical cryostats is typically carried out using fixed-length antennae to couple rf power into the cavity and to probe the energy stored into the cavity. Although variable couplers have been designed, built and used in the past, they are often a complex, costly, not very reliable auxiliary component to the cavity test. In this contribution we present the design and implementation of a simple variable rf antenna which has about 50 mm travel, allowing to obtain about four orders of magnitude variation in Qext -value. The motion of the antenna is driven by a motorized linear feedthrough outside of the cryostat. The antenna can easily be mounted on the most common type of cavity flanges.

Ciovati, G.↗

Insights into Nb3Sn coating of CEBAF cavities from witness sample analysis

With the progress made in the Nb3Sn coatings on single-cell SRF cavities, development is ongoing to reproduce single-cell cavity results on practical structures such as CEBAF 5-cell cavities. During CEBAF cavity coating development, several changes from the single-cell procedure to the coating setup and the heating profile were introduced to improve the quality of Nb3Sn films. To witness the properties of grown Nb3Sn films in different cavity locations, 10 mm x 10 mm samples were positioned in strategic places within the coating chamber. Composition and structure of the samples were analyzed with surface analytic techniques and correlated with sample location during coatings. Implications from sample analysis to Nb3Sn coatings on different geometries are discussed in this contribution.

Eremeev, G. V.↗

Nb3Sn films for SRF cavities: genesis and RF properties

Understanding of Nb3Sn nucleation and growth is essential to the progress with Nb3Sn vapor diffusion coatings of SRF cavities. Samples representing different stages of Nb3Sn formation have been produced and examined to elucidate the effects of nucleation, growth, process conditions, and impurities. Nb3Sn films from few hundreds of nm up to ~15 µm were grown and characterized using AFM, SEM/EDS, XPS, EBSD, SIMS, and SAM. Microscopic examinations of samples suggest the mechanisms behind Nb3Sn thin film nucleation and growth. RF measurements of coated cavities were combined with material characterization of witness samples to adapt the coating process in "Siemens" coating configuration. Understanding obtained from sample studies, applied to cavities, resulted in Nb3Sn cavity with quality factor 2 ×1010 at 15 MV/m accelerating gradient at 4 K, without "Wuppertal" Q-slope. We discuss the genesis of the Nb3Sn thin film in a typical tin vapor diffusion process, and its consequences to the coating of SRF cavities.

Pudasaini, U.↗

In situ SRF cavity processing using optical ionization of gases

A system and method for the in situ processing of internal SRF cavity surfaces to reduce field emission and improve maximum gradient. An electromagnetic radiation source is introduced in the bore of a superconducting cavity to enhance ionization or dissociation of gases which then remove contaminants from the surface of the cavity, either through direct surface bombardment, chemical reaction or through the production of radiation which interacts with the contaminants. An RF or low frequency electromagnetic field may be established in the cavity which further enhances the ionization or dissociation process and may cause the ions to bombard sites with enhanced electric fields. The invention removes the requirement that the RF field be sufficient by itself to ionize gas in the cavity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Narrow-linewidth single-mode vertical-cavity surface-emitting laser

A coupled-cavity vertical-cavity surface-emitting laser (VCSEL) is disclosed. The coupled-cavity VCSEL includes a passive cavity and an additional distributed Bragg Reflector (DBR) not found in conventional VCSELs, all in a monolithic device. By including these two elements, the photon lifetime may be increased by a factor of approximately ten, leading to a reduction in the laser linewidth by a factor of approximately 100 compared to conventional VCSELs. The two additional elements also serve to ensure single-mode operation of the coupled-cavity VCSEL.

Serkland, Darwin K.↗

DESIGN AND MEASUREMENT OF THE 1.4 GHZ CAVITY FOR LEReC LINAC

The Low Energy RHIC electron Cooler (LEReC) is the first electron cooler based on rf acceleration of electron bunches. To further improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon, a normal conducting RF cavity at 1.4 GHz was designed and fabricated for the LINAC that will provide longer electron bunches for the LEReC. It is a single cell cavity with effective cavity length shorter than half of the 1.4 GHz wavelength. This cavity was fabricated and tested on site at BNL to verify RF properties, i.e. the resonance frequency, fundamental power coupler (FPC) coupling strength, tuner system performance, and high-power tests. In this paper, we report the RF test results for this cavity.

43 PARTICLE ACCELERATORS↗

Preliminary Cryogenic Cold Test Results of the First 9-Cell LSF Shape Cavity

Following successful prototyping and testing of single- & 5-cell LSF shape cavities *, **, the first 9-cell LSF shape cavity LSF9-1 was successfully constructed using an innovative process at JLab with the in-house facilities. The cavity was then shipped to KEK for post-fabrication mechanical adjustment and ILC TDR style treatment and surface processing. Cold testing was carried out at the JLab VTA facility, instrumented with a suite of Kyoto instruments. Favorable values for the bath pressure detuning sensitivity and Lorentz force detuning coefficient were experimentally measured, validating the design improvement in cell stiffeners. Pass-band measurements indicate 4 out of 9 cells reaching gradient capability of > 45 MV/m, including 2 cells reaching 51 MV/m. Cornell OST detectors identified the cell and location responsible for the current hard quench limit. Multipacting-like barriers observed in end cells are investigated both analytically and numerically. The cavity was shipped to FNAL and received a light EP at the joint ANL/FNAL facility for further cold testing at Jlab. Two new 9-cell LSF cavities are being constructed including one made of large-grain niobium material.

Geng, Rong-Li↗

Longitudinally joined superconducting resonating cavities

A system and method for fabricating accelerator cavities comprises forming at least two half cavities and joining the half cavities with a longitudinal seal. The half cavities can comprise at least one of aluminum, copper, tin, and copper alloys. The half cavities can be coated with a superconductor or combination of materials configured to form a superconductor coating.

Cooley, Lance↗

Status of the Design of 650 MHz Elliptical Cavities for Project X

Project X is a proposed high-intensity proton accelerator complex that could provide beam to create a high-intensity neutrino beam, feed protons to kaon- and muon-based precision experiments, and for other applications still under investigation. The present configuration of the proton accelerator foresees a section with 650 MHz β = 0.6 and β = 0.9 elliptical cavities. Prototypes of single-cell 650 MHz cavities and five-cell β = 0.9 650 MHz cavities are being designed and fabricated at Fermilab in the R&D process for Project X. This paper summarizes the design status of the β = 0.6 and β = 0.9 single-cell prototype cavities, and also addresses the design effort focused on the five-cell β = 0.9 cavities.

43 PARTICLE ACCELERATORS↗

Engineering of Form Factor in Rotationally Symmetric Photonic Cavities for Faster Axion Searches

Form factor can be engineered in photonic cavities such that it dramatically increases the scan speed of axion haloscope detectors. Using higher-order modes of a photonic cavity, we can probe axions at larger mass ranges beyond the reach of current detectors that rely on conventional copper cavities. The main idea is to produce a higher-order mode with longitudinal field distribution that has relatively high amplitude away from both the cavity axis and the cavity walls such that it results in a relatively large form factor and maintains a high-quality factor. The detector scan speed significantly increases as it is proportional to the square of the form factor multiplied by the quality factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗