Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Multipath Curved Planar Reformations of Peripheral CT Angiography: Diagnostic Accuracy and Time Efficiency

ObjectivesTo compare diagnostic performance and time efficiency between 3D multipath curved planar reformations (mpCPRs) and axial images of CT angiography for the pre-interventional assessment of peripheral arterial disease (PAD), with digital subtraction angiography as the standard of reference.MethodsForty patients (10 females, mean age 72 years), referred to CTA prior to endovascular treatment of PAD, were prospectively included and underwent peripheral CT angiography. A semiautomated toolbox was used to render mpCPRs. Twenty-one arterial segments were defined in each leg; for each segment, the presence of stenosis > 70% was assessed on mpCPRs and axial images by two readers, independently, with digital subtraction angiography as gold standard.ResultsBoth readers reached lower sensitivity (Reader 1: 91 vs. 94%, p = 0.08; Reader 2: 89 vs. 93%, p = 0.03) but significantly higher specificity (Reader 1: 94 vs. 89%, p < 0.01; Reader 2: 96 vs. 95%, p = 0.01) with mpCPRs than with axial images. Reader 1 achieved significantly higher accuracy with mpCPRs (93 vs. 91%, p = 0.02), and Reader 2 had similar overall accuracy in both evaluations (94 vs. 94%, p = 0.96). Both readers read mpCPRs significantly faster than axial images (Reader 1: 5′45″ based on mpCPRs vs. 7′40″ based on axial images; Reader 2: 4′41″ based on mpCPRs vs. 6′57″ based on axial images; p < 0.01).ConclusionsmpCPRs are a promising 3D reformation technique that facilitates a fast assessment of PAD with high diagnostic accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Particle Imaging Guided Real-Time Percutaneous Transluminal Angioplasty in a Phantom Model

PurposeTo investigate the potential of real-time magnetic particle imaging (MPI) to guide percutaneous transluminal angioplasty (PTA) of vascular stenoses in a phantom model.Materials and MethodsExperiments were conducted on a custom-built MPI scanner. Vascular stenosis phantoms consisted of polyvinyl chloride tubes (inner diameter 8 mm) prepared with a centrally aligned cable tie to form ~ 50% stenoses. MPI angiography for visualization of stenoses was performed using the superparamagnetic iron oxide nanoparticle-based contrast agent Ferucarbotran (10 mmol (Fe)/l). Balloon catheters and guidewires for PTA were visualized using custom-made lacquer markers based on Ferucarbotran. Stenosis dilation (n = 3) was performed by manually inflating the PTA balloon with diluted Ferucarbotran. An online reconstruction framework was implemented for real-time imaging with very short latency time.ResultsVisualization of stenosis phantoms and guidance of interventional instruments in real-time (4 frames/s, ~ 100 ms latency time) was possible using an online reconstruction algorithm. Labeling of guidewires and balloon catheters allowed for precise visualization of instrument positions.ConclusionReal-time MPI-guided PTA in a phantom model is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Cone-Beam Tomography and Cross-Sectional Imaging for Volumetric and Dosimetric Calculations in Resin Yttrium-90 Radioembolization

PurposeTo compare the use of cone-beam computed tomography versus contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) in the calculation of liver volume and planned dose for yttrium-90 radioembolization.Materials and MethodsThe study retrospectively assessed 47 consecutive patients who underwent resin Y-90 radioembolization consecutively over a 2-year period at a single center. Volume calculation software was used to determine perfused lobar liver volumes from cone-beam CT (CBCT) images obtained during mapping angiography. CBCT-derived volumes were compared with perfused lobar volume derived from contrast-enhanced CT and MRI. Nominal activities as determined by the SIR-Spheres Microspheres Activity Calculator were similarly calculated and compared using both CBCT and conventionally acquired volumes.ResultsA total of 82 hepatic lobes were assessed in 47 patients. The mean percentage difference between combined CT-MRI- and CBCT-derived calculated lobar volumes was 25.3% (p = 0.994). The mean percentage difference in calculated dose between the two methods was 21.8 ± 24.6% (p = 0.42). Combined left and right lobar CT-derived dose difference was less than 10% in 22 lobes, between 10 and 25% in 20 lobes, between 25 and 50% in 13 lobes and greater than 50% in 5 lobes. Combined left and right lobar MRI-derived dose difference was less than 10% in 11 lobes, between 10 and 25% in 7 lobes, between 25 and 50% in 2 lobes and greater than 50% in 1 lobe.ConclusionsAlthough volume measurements derived from CT/MRI did not differ significantly from those derived from CBCT, variability between the two methods led to large and unexpected differences in calculated dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transjugular Intrahepatic Portosystemic Shunt Using the New Gore Viatorr Controlled Expansion Endoprosthesis: Prospective, Single-Center, Preliminary Experience

Objectives: To evaluate short-term clinical efficacy, complications and possible passive stent expansion of transjugular intrahepatic portosystemic shunt (TIPS) creation using the new controlled expansion ePTFE covered stent (VCX), for portal hypertension complications. Methods: Between 7/2016 and 3/2018, 75 patients received TIPS using VCX. Thirty-nine patients with VCX dilated with an 8-mm angioplasty balloon underwent computed tomography (CT) study during follow-up and CT data were used to measure stent diameter. The CT measurement technique was validated by ex vivo experiment. Results: TIPS indications were: refractory ascites (n = 45), variceal bleeding (n = 22), other (n = 8). Mean follow-up was 5.8 months (± 4.5, range 1–20). In 69 patients, TIPS was dilated to 8 mm of diameter reaching the hemodynamic target of a portosystemic pressure gradient (PSG) < 12 mmHg. In six patients, not reaching the hemodynamic target the stent was dilated to 10 mm of diameter during the same session with a final PSG < 12 mmHg. Overall clinical success was achieved in 66/75 (88%) patients (80% in refractory ascites, 95% variceal bleeding, 100% other). Grade II–III encephalopathy was observed in five patients (6%). TIPS revision with stent dilatation to 10 mm was performed in seven patients: in three patients with ascites persistence, without evidence of stent dysfunction and in four patients for stent stenosis. One patient underwent stent reduction. Fourteen patients (18%) died during follow-up of causes not related to TIPS. Five patients (6%) underwent liver transplant. No passive stent expansion was detected by CT measurements. Conclusion: VCX for TIPS creation retains its diameter over a short-term period and is associated with a good clinical outcome with a reasonably low complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of the Virtual Liver Parenchymal Perfusion Area Using a Commercially Available Workstation in Transarterial Chemoembolization for Hepatocellular Carcinoma

Purpose: To evaluate the accuracy of the virtual liver parenchymal perfusion area using a commercially available workstation and liver analysis software in conventional transarterial chemoembolization (cTACE) for hepatocellular carcinoma (HCC). Materials and Methods: This method was retrospectively applied to 29 treated HCCs in 23 patients. The virtual embolic area (VEA) was estimated based on cone beam computed tomography during hepatic arteriography using a commercially available workstation and liver analysis software by two observer groups (group A: experts; group B: semi-experts). The real embolic area (REA) was defined as the area where iodized oil accumulated on computed tomography at 1 week after cTACE. The REA was estimated by each of the two groups, and the mean REA between the groups (mREA) was used as a standard reference. Agreement of volume and cross-sectional area in three orthogonal planes between the VEA and mREA were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The ICCs for volume between VEA and mREA were 0.97 and 0.88 for groups A and B, respectively, and those for cross-sectional area were 0.94 and 0.88 for the axial plane, 0.95 and 0.83 for the coronal plane, and 0.87 and 0.74 for the sagittal plane, respectively. Thus, the overall agreement was excellent, except for the sagittal imaging plane in group B. Conclusion: This method using a commercially available workstation and liver analysis software can be useful for estimating the embolic area in cTACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Radiation Dose Reduction Considerations in a Contemporary Interventional Radiology Suite

PurposeWe sought to evaluate patient radiation exposure during complex liver interventional procedures performed with newer angiography equipment.Materials and MethodsWe conducted a retrospective study of transjugular intrahepatic portosystemic shunt (TIPS) creations and liver tumor embolizations performed in our new angiography suite (Discovery IGS740, GE Healthcare). T tests were used to compare air kerma-area product (P{sub KA}) and reference plane air kerma (K{sub a,r}) in the new room versus data from historical rooms and previous studies (including the RAD IR study). Results were expressed as medians [interquartile ranges (Q1, Q3)].ResultsFrom February 2015 to June 2016, 134 complex liver interventional procedures were performed in the new room, including 14 TIPS creations, 60 hepatic tumor arterial embolizations (HAEs), 26 Y90 mappings (Y90m), and 34 Y90 radioembolizations (Y90). K{sub a,r} (Gy) values were as follows: TIPS, 0.65 (0.24, 1.15); HAE, 0.89 (0.49, 1.49); Y90m, 0.54 (0.38, 0.94); Y90, 0.46 (0.21, 1.06). P{sub KA} (Gy·cm{sup 2}) values were as follows: TIPS, 148.2 (66.7, 326.5); HAE, 142.6 (88, 217.8); Y90m, 148.3 (98.2, 247); Y90, 90.8 (43.9, 161.5). K{sub a,r} and P{sub KA} were lower in the new room than in historical rooms [K{sub a,r} and P{sub KA} reductions: TIPS, 58 and 49%; HAE, 31 and 39%; Y90m, 58 and 52%; Y90, 49 and 56% (p < 0.05)] and versus the RAD IR study [K{sub a,r} and P{sub KA} reductions: TIPS, 64 and 43%; HAE, 26 and 40% (p < 0.05)].ConclusionsUsing the latest technology and image processing tools enables significant reduction in radiation exposure during complex liver interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging and Endovascular Treatment of Bleeding Pelvic Fractures: Review Article

Pelvic fractures are potentially life-threatening injuries with high mortality rates, mainly due to intractable pelvic arterial bleeding. However, concomitant injuries are frequent and may also be the cause of significant blood loss. As treatment varies depending on location and type of hemorrhage, timely imaging is of critical importance. Contrast-enhanced CT offers fast and detailed information on location and type of bleeding. Angiography with embolization for pelvic fracture hemorrhage, particularly when performed early, has shown high success rates as well as low complication rates and is currently accepted as the first method of bleeding control in pelvic fracture-related arterial hemorrhage. In the current review imaging workup, patient selection, technique, results and complications of pelvic embolization are described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization of Spontaneous Soft Tissue Hematomas: A Systematic Review

Background: Severe spontaneous soft tissue hematomas (SSTH) are usually treated with transcatheter arterial embolization (TAE) although only limited retrospective studies exist evaluating this treatment option. The aim of this study was to systematically assess the efficacy and safety of TAE for the management of SSTH. Methods: Medline, EMBASE, PubMed and Cochrane Library were searched from inception to July 2017 using MeSH headings and a combination of keywords. Eligibility was restricted to original studies with patients suffering from SSTH treated with TAE. Patients with traumatic hematomas or who were treated with solely conservative or surgical management were excluded. For each publication, clinical success based on the control of the bleed, rebleeding rates and complications (including mortality) was collected, as well as technical details. Results: Sixty-three studies met the inclusion criteria, with an aggregate total of 267 patients. Follow-up extended from 1 day to 10 years. Bleeding was mainly localized to the iliopsoas (n = 113/267, 42.3%) and anterior abdominal wall (n = 145/266, 54.7%). When information was available, 81.0% (n = 158/195) of patients were on anticoagulant therapy prior to the bleeding episode. Initial stabilization with control of the bleed was obtained in 93.1% (n = 242 patients, n = 60 studies). The most common embolic materials were coils (n = 129, 54.4%). Rebleeding was reported in 25 patients (9.4%). Only two embolization complications were reported (0.7%). The 30-day mortality was 22.7% (n = 42/1857). Conclusion: TAE represents a safe and effective procedure in the management of SSTH. We present a management algorithm based on these data, but further studies are needed to address the knowledge gap.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Transcatheter Arterial Microembolization on Phantom Limb Pain Persisting for 17 Years

Phantom limb pain is a frequent consequence of the amputation; currently available treatments are far from satisfactory. The present report describes a case in which transcatheter arterial microembolization had a remarkable curative effect on phantom limb pain persisting for 17 years. The patient began feeling phantom limb sensations and brief intermittent pain following lower limb amputation above the knee in 2001. The frequency, intensity, and duration of the pain increased over time, and it was resistant to conservative treatments. Following transcatheter arterial microembolization in 2018, patient immediately experienced marked improvement. The pain has been infrequent, much less intense, and did not interfere with daily life 6 months posttreatment. Transcatheter arterial microembolization could be an alternative treatment option for phantom limb pain. Level of Evidence: IV, Case Report.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-hole Versus Microvalve Infusion Catheters in Patients Undergoing Drug-Eluting Microspheres-TACE for Solitary Hepatocellular Carcinoma Tumors: A Retrospective Analysis

Introduction: Pre-transplant locoregional therapy for hepatocellular carcinoma (HCC) during bridge-to-transplant impacts recurrence and survival rates following liver transplantation. Optimizing the effectiveness of transarterial chemoembolization (TACE) in this population is imperative, and microvalve infusion catheters offer a means of such improvement. Methods: All treatment-naive patients with solitary HCC tumors < 6.5 cm who underwent drug-eluting microspheres (DEM) TACE between 04/2015 and 08/2017 were retrospectively reviewed. Eighty-eight included patients underwent DEM-TACE with either standard end-hole catheters (EH) or microvalve infusion catheters (MVI). The EH (n = 70) and MVI (n = 18) cohorts had similar baseline tumor size, laboratory values, and tumor etiologies. Results: Initial objective response rates were significantly higher in MVI vs. EH (100% vs. 76.5%, p = 0.019). There was no difference in adverse events between groups (p = 0.265). MVI patients exhibited lower AST (p = 0.003) and ALT (p = 0.044) at 6 months. Blinded pathological analysis of explanted livers showed greater concentrations of microspheres within the tumor relative to the surrounding tissue in MVI explants (88.7 ± 10.6%) versus the EH explants (55.3 ± 32.7%) (p = 0.002). There was significantly higher percentage tumor necrosis in the MVI group (89.0 ± 2.2%) compared with the EH group (56.1 ± 44.5%) (p = 0.006). Conclusion: In this retrospective study of a single-center cohort, DEM-TACE procedures with MVI were associated with improved tumor response, increased deposition of microspheres within tumor tissue, and higher percentage tumor necrosis at explant relative to those performed using EH catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemosaturation Percutaneous Hepatic Perfusion (CS-PHP) with Melphalan: Evaluation of 2D-Perfusion Angiography (2D-PA) for Leakage Detection of the Venous Double-Balloon Catheter

Purpose: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) for detecting leakage of the double-balloon catheter used for chemosaturation percutaneous hepatic perfusion (CS-PHP). Materials and Methods: Overall, 112 CS-PHP (09/2015-09/2018) in 52 patients were retrospectively screened for leakage alongside the double-balloon catheter on standard venograms. Finally, 18 procedures with visually detected leakage were included. Fifteen consecutive procedures without leakage served as control. To evaluate 2D-PA for leakage detection, the acquired digital subtraction venograms were post-processed. For each balloon, two different target ROIs were evaluated to assess a possible impact of localization and shape of the ROIs. Time to peak (TTP), peak density (PD), area under the curve (AUC), and ratios of target ROI/reference ROIs (PD{sub tROI}/PD{sub REF}; AUC{sub tROI}/AUC{sub REF}; and TTP{sub tROI}/TTP{sub REF}) were calculated. Results: Leakages were located as follows: 15/18 cranial and 3/18 caudal. At the cranial balloon both ROIs showed a significant decrease in PD{sub tROI}/PD{sub REF} and AUC{sub tROI}/AUC{sub REF} (ROI1: p < 0.0001; p < 0.0001; ROI2: p < 0.0001; p < 0.0001) and a significant increase in TTP{sub tROI}/TTP{sub REF} (ROI1: p = 0.0009; ROI2: p = 0.0003) after double-balloon correction. Following balloon adjustment, the 2D-PA ratios (PD and AUC) of the tested ROIs differed significantly (p < 0.05). The inter-individual comparison of the 2D-PA parameters of the group with leakage before balloon correction and the non-leakage group showed significantly different 2D-PA values for the cranial balloon in both ROIs (p < 0.05). No significant differences were found for the caudal balloon. Conclusion: 2D-PA provides a feasible tool for detecting leakages alongside the cranial portion of the double-balloon catheter used in CS-PHP. The shape and position of the ROIs used to assess perfusion and flow have an impact on the measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of Endovascular Aortic Repair Using 3D Printed Abdominal Aortic Aneurysm Model and Fluid Pump

Background: Abdominal aortic aneurysm (AAA) models can be manufactured with 3D printing technology. This study describes detailed methodology and validation of endovascular aortic repair (EVAR) simulation using 3D printed AAA model connected to hemodynamic pump. Method: The AAA model was printed with Objet500 Connex3 (Stratasys, Eden Prairie, MN) and connected to BDC PD-0500 fluid pump (BDC Laboratories, Wheat Ridge, CO). EVAR procedure metrics were benchmarked in two expert implanters and compared to 20 vascular surgical trainees with different levels of EVAR experience (< 20 or ≥ 20 cases). All simulations were performed using commercially available stent grafts, guidewires, catheters, fluoroscopic guidance and digital subtraction angiography. Studied outcomes included ability to complete the procedure independently, time to deploy aortic component, ability to cannulate contralateral gate and complete the repair, and total fluoroscopy and procedure times. Results: A total of 22 EVAR simulation procedures were performed with mean procedure time of 37 ± 12 min. Experienced trainees had significantly lower total procedural time (32 ± 9 vs. 44 ± 6 min, P = 0.003) and fluoroscopic time (13 ± 5 vs. 23 ± 8 min, P = 0.005). All experienced trainees completed the procedure independently in < 45 min, compared to six (46%) of those with less EVAR experience (P = 0.016). Among less experienced trainees, only two (15%) completed the entire procedure independently (P < 0.001). Benchmark implanters performed significantly better than both trainee groups in nearly all EVAR metrics. Conclusion: EVAR simulation was feasible and simulated all procedural steps with high fidelity. This model may be applicable for assessment of technical competencies and standard endovascular skill acquisition within vascular surgery training curricula.

3D PRINTING↗

Noninvasive Assessment of Right Ventricular Function in Patients with Pulmonary Arterial Hypertension and Left Ventricular Assist Device

Purpose of Review: Right ventricular (RV) failure in patients with pulmonary arterial hypertension (PAH) and left ventricular assist device (LVAD) is associated with increased hospitalizations, worsening functional class, and poor survival. Accurate RV function assessment is essential in diagnosing RV failure, guiding therapies, and determining prognosis. Noninvasive imaging techniques provide fast and reliable quantification of RV morphology and function. Recent Findings: We review echocardiography, nuclear medicine, and cardiac magnetic resonance imaging (MRI) uses for RV function assessment in patients with PAH and LVAD. We identify current knowledge gaps in utilizing noninvasive tests to assess RV function. Summary: Echocardiography is most widely used to quantify RV function in patients with PAH and LVAD, followed by cardiac MRI for RV morphology and function measurement in PAH patients. The first-pass radionuclide angiography with radiolabeled RBC is the gold standard for calculating RV function. Gated blood pool SPECT can be an alternative as it separates the cardiac chambers well and provides accurate assessment of the RV function with high reproducibility, which is particularly useful for monitoring treatment. More research is needed to compare and validate these modalities in evaluating RV function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation

Introduction: This study investigated the performance of SPECT myocardial blood flow (MBF) quantitation lacking full physical corrections (All Corr) in dynamic SPECT (DySPECT) images. Methods: Eleven healthy normal volunteers (HVT) and twenty-four patients with angiography-documented CAD were assessed. All Corr in {sup 99m}Tc-sestamibi DySPECT encompassed noise reduction (NR), resolution recovery (RR), and corrections for scatter (SC) and attenuation (AC), otherwise no correction (NC) or only partial corrections. The performance was evaluated by quality index (R{sup 2}) and blood-pool spillover index (FBV) in kinetic modeling, and by rest flow (RMBF) and stress flow (SMBF) compared with those of All Corr. Results: In HVT group, NC diminished 2-fold flow uniformity with the most degraded quality (15%-18% reduced R{sup 2}) and elevated spillover effect (45%-50% increased FBV). Consistently higher RMBF and SMBF were discovered in both groups (HVT 1.54/2.31 higher; CAD 1.60/1.72; all P < .0001). Bland-Altman analysis revealed positive flow bias (HVT 0.9-2.6 mL/min/g; CAD 0.7-1.3) with wide ranges of 95% CI of agreement (HVT NC −1.9-7.1; NR −0.4-4.4; NR + SC −1.1-4.3; NR + SC + RR −0.7-2.5) (CAD NC −1.2-3.8; NR −1.0-2.8; NR + SC −1.0-2.5; NR + SC + RR −1.1-2.6). Conclusions: Uncorrected physical interference in DySPECT images can extensively impact the performance of MBF quantitation. Full physical corrections should be considered to warrant this tool for clinical utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of cardiac resynchronization therapy on right ventricular function during rest and exercise, as assessed by radionuclide angiography, and on NT-proBNP levels

Aim: We carried out this study to investigate mid-term effects of cardiac resynchronization therapy (CRT) on right ventricular (RV) function and neurohormonal response, expressed by N-terminal pro-brain natriuretic peptide (NT-proBNP), in heart failure patients stratified by baseline RV ejection fraction (RVEF). Methods and Results: Thirty-six patients with nonischemic dilated cardiomyopathy underwent technetium-99m radionuclide angiography with bicycle exercise immediately after CRT implantation (during spontaneous rhythm and after CRT activation) and 3 months later. Plasma NT proBNP was assessed before implantation and after 3 months. At baseline, RVEF was impaired (≤35%) in 14 patients, preserved (>35%) in 22. At 3 months, RVEF improved during rest and exercise (P = .02) in patients with impaired RV function, while remaining unchanged in patients with preserved RV function. Rest and exercise RV dyssynchrony decreased in both groups at follow-up (P < .05). A similar mid-term improvement in left ventricular (LV) function and NT-proBNP was observed in patients with impaired and preserved RVEF. In the former, the decrease in NT-proBNP correlated with the improvements both in LV and RV dyssynchrony and functions. Conclusion: CRT may improve RV performance, during rest and exercise, and neurohormonal response in heart failure patients with nonischemic dilated cardiomyopathy and baseline RV dysfunction. RV dysfunction should not be considered per se a primary criterion for excluding candidacy to CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗