Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BETA DECAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment

The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs. muons, $R_{e/\mu}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $\pi^+\to \pi^0 e^+ \nu (\gamma)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02% level, comparable to the deduction from superallowed beta decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNO+ Scintillator Purification and Assay

We describe the R and D on the scintillator purification and assay methods and technology for the SNO+ neutrino and double-beta decay experiment. The SNO+ experiment is a replacement of the SNO heavy water with liquid scintillator comprised of 2 g/L PPO in linear alkylbenzene (LAB). During filling the LAB will be transported underground by rail car and purified by multi-stage distillation and steam stripping at a flow rate of 19 LPM. While the detector is operational the scintillator can be recirculated at 150 LPM (full detector volume in 4 days) to provide repurification as necessary by either water extraction (for Ra, K, Bi) or by functional metal scavenger columns (for Pb, Ra, Bi, Ac, Th) followed by steam stripping to remove noble gases and oxygen (Rn, O{sub 2}, Kr, Ar). The metal scavenger columns also provide a method for scintillator assay for ex-situ measurement of the U and Th chain radioactivity. We have developed ''natural'' radioactive spikes of Pb and Ra in LAB and use these for purification testing. Lastly, we present the planned operating modes and purification strategies and the plant specifications and design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Data Sheets for A = 229

The evaluators present in this publication spectroscopic data and level schemes from radioactive decay and nuclear reaction studies for all nuclei with mass number A = 229. These nuclei belong to a region of coexisting quadrupole with possible octupole deformations. The latter have been observed in {sup 229}Ra, but in {sup 229}Pa the experimental evidence is inconclusive. The present evaluation of A = 229, which includes all data received by June 2008, supersedes the 1989 evaluation by Y.A. Akovali, published in Nuclear Data Sheets58, 555 (1989). Highlights of this publication are given below: A comprehensive spectroscopic study of {sup 229}Fr(50.2 s) {beta}- decay using mass-separated sources have provided the first evidence of parity doublets in {sup 229}Ra due to nuclear octupole deformation (1999Fr33). In {sup 229}Th a level at 7.6 5 eV - the closest level to the ground state ever known - has been confirmed through extremely precise measurements of {gamma}-ray energies from {sup 233}U {alpha} decay (1994He08, 2007Be16). A nuclear level at such low energy may be used for studying a large variety of atomic properties associated to nuclear decay. The level structure in {sup 229}Pa has been interpreted in terms of the rotational model (1994Le22). Some authors, however, have proposed the existence of parity doublets as evidence of octupole nuclear deformation (1982Ah08). This interpretation has not been confirmed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The CUORE and CUORE-0 experiments at LNGS

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. The construction of the experiment and, in particular, the installation of all towers in the cryostat was completed in August 2016 and commissioning started in fall 2016. The experiment has completed the pre-operation phase and is currently in data taking. We present here the achievements of CUORE during the commissioning phase and the limit on the 130Te half-life for the neutrinoless double beta decay that has been released after the first 3 weeks of collected data. Physics results from CUORE-0 will also be updated.

Alduino, C↗

Delayed charge recovery discrimination of passivated surface alpha events in P-type point-contact detectors

The Majorana Demonstrator searches for neutrinoless double-beta decay of 76 Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that lepton number is not a conserved quantity in nature, with implications for grand-unification and for explaining the predominance of matter over antimatter in the universe. A problematic background in such large granular detector arrays is posed by alpha particles. In the Majorana Demonstrator, events have been observed that are consistent with energy- degraded alphas originating on the passivated surface, leading to a potential background contribution in the region-of-interest for neutrinoless double-beta decay. However, it is also observed that when energy deposition occurs very close to the passivated surface, charges drift through the bulk onto that surface, and then drift along it with greatly reduced mobility. This leads to both a reduced prompt signal and a measurable change in slope of the tail of a recorded pulse. In this contribution we discuss the characteristics of these events and the development of a filter that can identify the occurrence of this delayed charge recovery, allowing for the efficient rejection of passivated surface alpha events in analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent results of the Majorana Demonstrator experiment

The Majorana Demonstrator is searching for neutrinoless double-beta decay in 76Ge with two modular arrays of natural and 76Ge-enriched germanium detectors. It is located at the 4850' level of Sanford Underground Research Facility in Lead, South Dakota, USA, and its total mass of germanium detectors is 44.1 kg, of which 29.7 kg is enriched. The analysis of the first 26 kg-yr of data provides an unprecedented energy resolution of 0.13% in the region of interest at 2039 keV and a background level of 15.4 ±2.0 counts/(FWHM t yr). It establishes the lower limit of the half-life of neutrinoless double beta decay as 2.7 1025 yr in 76Ge at 90% CL. This analysis will be summarized here with an emphasis on the energy determination.

López-Castaño, JM↗

The present and future status of heavy neutral leptons

Abstract The existence of nonzero neutrino masses points to the likely existence of multiple Standard Model neutral fermions. When such states are heavy enough that they cannot be produced in oscillations, they are referred to as heavy neutral leptons (HNLs). In this white paper, we discuss the present experimental status of HNLs including colliders, beta decay, accelerators, as well as astrophysical and cosmological impacts. We discuss the importance of continuing to search for HNLs, and its potential impact on our understanding of key fundamental questions, and additionally we outline the future prospects for next-generation future experiments or upcoming accelerator run scenarios.

Abdullahi, Asli M.↗

Calibration of the NEXT-White detector using 83m Kr decays

We report the NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterraneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83m Kr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 +/- 0.010 (stat.) ± 0.324 (sys.)) % FWHM in the full chamber and (3.804 ± 0.013 (stat.) ± 0.112 (sys.)) % FWHM in a restricted fiducial volume. Laslty, using naive 1/$ \sqrt{E} $ scaling, these values translate into resolutions of (0.5916 ± 0.0014 (stat.) ± 0.0421 (sys.)) % FWHM and (0.4943 ± 0.0017 (stat.) +/- 0.0146 (sys.)) % FWHM at the Qᵦᵦ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

47 OTHER INSTRUMENTATION↗

On the statistical treatment of the Cabibbo angle anomaly

We point out that testing the equality of the Cabibbo angle as extracted from $\Gamma(K\rightarrow \pi l\nu)$, the ratio $\Gamma(K\rightarrow l\nu)/\Gamma(\pi\rightarrow l\nu)$ and nuclear $\beta$ decays is not identical to a test of first row unitarity of the Cabibbo-Kobayashi-Maskawa (CKM) matrix. The reason is that a CKM unitarity test involves only two parameters, while the degrees of freedom for the assessment of the goodness-of-fit of the universality of the Cabibbo angle entailed by the Standard Model (SM) is equal to the number of measurements minus one. Beyond the SM all different processes could in principle give different Cabibbo angles. Consequently, the difference between the two tests becomes relevant starting from three observables giving results for the Cabibbo angle that are in tension with each other. With current data, depending on the treatment of the nuclear $\beta$ decays, we find that New Physics is favored over the SM at $5.1\,\sigma$ or $3.6\,\sigma$ while CKM unitarity is rejected at $4.8\sigma$ or $3.0\sigma$, respectively. We argue that the best method to test the SM is to test the equality of the Cabibbo angle, because CKM unitarity is only one aspect of the SM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopy of Ba andBa+deposits in solid xenon for barium tagging in nEXO

Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence, and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba + deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of fewer than or equal to 10 4 Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-resolution study of the {sup 9}Be({sup 3}He,t){sup 9}B reaction up to the {sup 9}B triton threshold

A high-energy-resolution {sup 9}Be({sup 3}He,t){sup 9}B charge-exchange reaction was performed around a scattering angle of 0 deg. and at an intermediate incident energy of 140 MeV/nucleon for the study of precise Gamow-Teller (GT) transition strengths. The energy resolution of 30 keV allowed a precise deconvolution of the spectrum and the determination of angular distributions of cross sections, excitation energies, and decay widths. The GT strength of 10 states has been determined for the first time using the GT strength of the analogous {beta} decays of {sup 9}Li and {sup 9}C as standards. The large difference between the GT strengths going to the low-lying T=1/2 and the highly excited T=3/2 states is interpreted as a result of their different spatial structures. The obtained GT strength distribution is compared to the results of a (p,n) experiment with lower resolution performed in the 1980s. In particular, the width of the 16.8 MeV, J{sup {pi}=}(5/2{sup +}) state has been determined for the first time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic field mapping of the UCNTau magneto-gravitational trap: design study

The beta decay lifetime of the free neutron is an important input to the Standard Model of particle physics, but values measured using different methods have exhibited substantial disagreement. The UCN r experiment in development at Los Alamos National Laboratory (LANL) plans to explore better methods of measuring the neutron lifetime using ultracold neutrons (UCNs). In this experiment, UCNs are confined in a magneto-gravitational trap formed by a curved, asymmetric Halbach array placed inside a vacuum vessel and surrounded by holding field coils. If any defects present in the Halbach array are sufficient to reduce the local field near the surface below that needed to repel the desired energy level UCNs, loss by material interaction can occur at a rate similar to the loss by beta decay. A map of the magnetic field near the surface of the array is necessary to identify any such defects, but the array's curved geometry and placement in a vacuum vessel make conventional field mapping methods difficult. A system consisting of computer vision-based tracking and a rover holding a Hall probe has been designed to map the field near the surface of the array, and construction of an initial prototype has begun at LANL. The design of the system and initial results will be described here.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Contamination control and assay results for the Majorana Demonstrator ultra clean components

The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. In conclusion, this article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

36 MATERIALS SCIENCE↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Characterization of a new modular decay total absorption gamma-ray spectrometer (DTAS) for FAIR

Beta-decay studies are one of the main goals of the DEcay SPECtroscopy experiment (DESPEC) to be installed at the future Facility for Antiproton and Ion Research (FAIR). DESPEC aims at the study of nuclear structure of exotic nuclei. A new modular Decay Total Absorption gamma-ray Spectrometer (DTAS) is being built at IFIC and is specially adapted to studies at fragmentation facilities such as the Super Fragment Separator (Super-FRS) at FAIR. The designed spectrometer is composed of 16 identical NaI(Tl) scintillation crystals. This work focuses on the characterization of these independent modules, as an initial step for the characterization of the full spectrometer. Monte Carlo simulations have been performed in order to understand the detector response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results from the CUORE experiment

CUORE (Cryogenic Underground Observatory for Rare Events) is a ton-scale experiment aiming to the search of neutrino-less double beta decay in 130 Te with a projected sensitivity on the Majorana effective mass close to the inverted hierarchy region. The CUORE detector consists of a segmented array of 988 TeO 2 bolometers, organized in 19 towers and operated at a temperature of about 10 mK thanks to a custom cryogenic system which, besides the uncommon scale, observes several constraints from the radio-purity of the materials to the mechanical decoupling of the cooling systems. The successful commissioning of the CUORE cryogenic system has been completed early in 2016 and represents an outstanding achievement by itself. The installation of the detector proceeded along 2016 followed by the cooldown to base temperature at the beginning of 2017. The CUORE detector is now operational and has been taking science data since Spring 2017. With the first ~3 weeks of collected data, we present here the most stringent constraint on the 130 Te half-live for the neutrino-less double beta decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The commissioning of the CUORE experiment: the mini-tower run

CUORE is a ton-scale experiment approaching the data taking phase in Gran Sasso National Laboratory. Its primary goal is to search for the neutrinoless double-beta decay in Te-130 using 988 crystals of tellurim dioxide. The crystals are operated as bolometers at about 10 mK taking advantage of one of the largest dilution cryostat ever built. Concluded in March 2016, the cryostat commissioning consisted in a sequence of cool down runs each one integrating new parts of the apparatus. The last run was performed with the fully configured cryostat and the thermal load at 4 K reached the impressive mass of about 14 tons. During that run the base temperature of 6.3 mK was reached and maintained for more than 70 days. An array of 8 crystals, called mini-tower, was used to check bolometers operation, readout electronics and DAQ. Results will be presented in terms of cooling power, electronic noise, energy resolution and preliminary background measurements.

Copello, Simone↗

Experimental studies of nuclear matrix elements for neutrino-less ββ decays

Nuclear matrix elements M{sup 0ν} for neutrino less double beta decays (0νββ) are crucial for neutrino studies in 0νββ experiments. The neutrino mass to be studied is sensitive to M{sup 0ν}, while theoretical calculations for M{sup 0ν} are hard. Thus experimental studies of nuclear structures and single β matrix elements M{sub β} associated with 0νββ are useful to confirm and help the theoretical calculations. This reports briefly experimental methods and recent charge exchange reaction studies for M{sub β}. The single β elements for M{sup ±}(2{sup −}) associated with M{sup 0ν}(2{sup −}), which is the major component of M{sup 0ν}, are found to be reduced (quenched) much by the spin isospin correlation and the nuclear medium (non-nucleonic isobar) effect. The present result suggests that the spin isospin components of M{sup 0ν} is fairly reduced (quenched)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗