Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BENCHMARKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

The spectroscopic quadrupole moment of the 2 1 + state of 12 C: A benchmark of theoretical models

The spectroscopic quadrupole moment of the first 2 + state of 12 C has been measured employing the Coulomb-excitation re-orientation technique. Our result of $Q_{s} (2^{+}_{1}) = +9.3^{+3.5}_{-3.8}$ efm 2 suggests a larger oblate deformation than previously reported. Combining this with the consistently re-analyzed adopted value, we present the most precise value to date of $Q_{s} (2^{+}_{1})$ = +9.5(18) efm 2 , which is consistent with a geometrical rotor description. This simple outcome is compared to state-of-the-art shell-model, mean-field, ab initio calculations, cluster-based and geometrical-like theories, which show varying degrees of emergent quadrupole collectivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Benchmarking state-of-the-art theory and empirical models of pionless neutrino-argon scattering in GENIE

Upcoming experiments need improved simulations of neutrino scattering. This work uses the popular GENIE event generator to test a variety of neutrino interaction models against recent MicroBooNE measurements of pionless charged-current interactions. The GENIE code can easily interchange model components, including nucleon form factor parameterizations, quasielastic cross-section calculations, treatments of the nuclear ground state and hadronic final-state interactions. Leveraging this software capability in comparisons with MicroBooNE data, the performance of some of GENIE’s most theoretically sophisticated model components is evaluated and contrasted with more empirically-driven alternatives.

Neutrino cross section↗

Worldwide benchmarking of cost-effective radiometers for direct and diffuse irradiance

Solar energy projects can benefit from direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) measurements during all project phases. Several commercial measurement systems for DNI and DHI are available. Sun trackers with pyranometers and pyrheliometers can provide highly accurate measurements but are often impractical in solar energy applications. For less expensive and more robust sensors, it is often unclear which accuracy can be expected under a project site's specific atmospheric conditions. We address this challenge through our dedicated experimental comparison of relevant sensor systems (rotating shadowband irradiometer [short RSI], Delta-T SPN1, EKO MS-90, PyranoCam, Sunto CaptPro, Kipp & Zonen CSD3) at up to six sites worldwide. The RSI systems (rRMSD 3 to 8.6%, DNI; 4.8 to 7.6%, DHI) and PyranoCam (rRMSD 2.6 to 5.2%, DNI; 4.4 to 5.8%, DHI) exhibit similar error metrics and are the most accurate systems in the test. Delta-T SPN1 and EKO MS-90 (rRMSD 6.8 to 15%, DNI; 10.6 to 20.1%, DHI) but especially Kipp & Zonen CSD3 and Sunto CaptPro show significant deviations (rRMSD 17.7 to 20%, DNI; 33 to 58%, DHI). We evaluate the influence of relevant atmospheric parameters on the sensors' accuracies by a rather unique measurement setup. MS-90's DNI errors depend on DNI itself, with overestimations for low reference DNI. The deviations of SPN1's DHI and DNI measurements increase sharply in situations with high circumsolar irradiance. Also CaptPro and CSD3's increased measurement errors are related to circumsolar irradiance. For RSI and PyranoCam, only moderate influences on the measurements are identified, indicating a general applicability of these instruments.

14 SOLAR ENERGY↗

CO adsorption on MnO(100): Experimental benchmarks compared to DFT

In this study, CO adsorption on the MnO(100) surface was studied using temperature programmed desorption (TPD) and density functional theory (DFT). TPD results show that CO is weakly-bound on MnO(100), with an experimental adsorption energy of -35.6 ± 2.1 kJ/mol at terrace sites in the low coverage limit. PBE simulations suggest that CO adsorption causes an implausible (2 × 2) surface reconstruction. PBE+U simulations show no signs of surface reconstruction, and provide an accurate estimate of the adsorption energy (-36.4 kJ/mol) when combined with the DFT-D3 method with Becke-Jonson damping to correct for van der Waals interactions. This simulation also shows that CO adsorbs C-down onto the Mn 2+ terrace site in a tilted geometry, which is also observed experimentally and computationally on the similarly-structured NiO(100) transition metal oxide surface. TPD results for large doses show a plateauing of the coverage at about 0.4 monolayers of CO at 85 K, with a defect coverage equivalent to 0.08 monolayers. Adsorption associated with defect sites is indicated by a high-temperature desorption tail which is not satisfactorily explained by DFT simulations of simple step or oxygen vacancy defects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benchmarking Concentration and Extraction Methods for Wastewater-Based Surveillance of Eight Human Respiratory Viruses: Implications for Rapid Application to Novel Pathogens

To provide early warning and support a rapid response to a novel virus through wastewater surveillance, it would be ideal to understand in advance which concentration and extraction methods are likely to be effective for dPCR-based methods, depending on virus characteristics. In this study, we spiked raw wastewater samples with eight human respiratory viruses and processed them with four methods that concentrate and/or extract nucleic acids from both liquid and solid fractions (Promega, Nanotrap, and InnovaPrep) or only the solid fraction of wastewater (Solids). Our findings provide encouraging evidence that all four methods combined with dPCR could detect an emerging virus in wastewater, although they differed in sensitivity. The pattern of recovery efficiency for adenoviruses, coronaviruses, and influenza A viruses was consistent across methods, with Promega producing higher median recovery efficiencies, while distinct patterns were observed for coxsackieviruses. We also normalized the concentration data with two endogenous fecal indicators, PMMoV and Carjivirus (formerly crAssphage). We found that normalization could reduce method-associated differences if the indicator exhibited a recovery pattern similar to that of the target virus. These findings can guide the selection of concentration and extraction methods for wastewater monitoring based on the properties of target viruses, thus enhancing pandemic preparedness.

Biological and medical sciences↗

Density Functionals for Hydrogen Storage: Defining the H2Bind275 Test Set with Ab Initio Benchmarks and Assessment of 55 Functionals

Efficient and high-capacity storage materials are indispensable for a hydrogen-based economy. In silico tools can accelerate the process of discovery of new adsorbent materials with optimal hydrogen adsorption enthalpies. Density functional theory is well-poised to become a very useful tool for enabling high-throughput screening of potential materials. In this work, we have identified density functional approximations that provide good performance for hydrogen binding applications following a two-pronged approach. First, we have compiled a data set (H2Bind275) that comprehensively represents the hydrogen binding problem capturing the chemical and mechanistic diversity in the binding sites encountered in hydrogen storage materials. We have also computed reference interaction energies for this data set using coupled-cluster theory. Second, we have assessed the performance of 55 density functional approximations for predicting H 2 interaction energies and have identified two hybrid density functionals (ωB97X-V and ωB97M-V), two double hybrid density functionals (DSD-PBEPBE-D3(BJ) and PBE0-DH), and one semilocal density functional (B97M-V) as the best performing ones. We have recommended the addition of empirical dispersion corrections to systematically underbinding density functionals such as revPBE, BLYP, and B3LYP for improvements in performance at negligible additional cost. We have also recommended the usage of the def2-TZVPP basis set as it represents a good compromise between accuracy and cost, limiting the finite basis set errors to less than 1 kJ/mol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗