Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RELAP5-3D Developmental Assessment: Comparison of Versions 4.0.3is and 2.4.2is

Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.0.3is and 2.4.2is. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Developmental Assessment: Comparison of Versions 4.1.3is and 4.0.3is

Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.1.3is and 4.0.3is. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Developmental Assessment: Comparison of Versions 4.2.1i and 4.1.3i

Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.2.1i and 4.1.3i. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Developmental Assessment: Comparison of Versions 4.3.4i and 4.2.1i

Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.3.4i and 4.2.1i. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP-7 Software Verification and Validation Plan - Requirements Traceability Matrix (RTM) Part 2: Code Assessment Strategy, Procedure, and RTM Update

This document addresses two subjects involved with the RELAP-7 Software Verification and Validation Plan (SVVP): (i) the principles and plan to assure the independence of RELAP-7 assessment through the code development process, and (ii) the work performed to establish the RELAP-7 assessment plan, i.e., the assessment strategy, literature review, and identification of RELAP-7 requirements. Then, the Requirements Traceability Matrices (RTMs) proposed in previous document (INL-EXT-15-36684) are updated. These RTMs provide an efficient way to evaluate the RELAP-7 development status as well as the maturity of RELAP-7 assessment through the development process.

97 MATHEMATICS AND COMPUTING↗

Retrofit of Blown Attic Insulation in Existing HUD-Code Manufactured Homes: Needs Assessment Report

This needs assessment was conducted by the Washington State University (WSU) Energy Program and Building Science Corporation (BSC), with support from the U.S. Department of Energy's (DOE) Building Technologies Office. The primary goal of this research was to identify moisture durability, energy savings, and savings-to-investment ratio (SIR) research needs related to the retrofit of attic insulation in the DOE Weatherization Assistance Program (WAP). Specifically, manufactured homes that comply with building codes established by the U.S. Department of Housing and Urban Development (HUD) built after 1976 and sited in colder climates. This project assessed current practice of WAP insulation and/or roof venting solutions that improve attic insulation energy savings and durability. WSU and BSC conducted outreach to stakeholders via email, phone, one-on-one interviews, and group meetings designed to inquire about relevant issues that they may have observed. Needs assessment feedback was provided from stakeholders involved with attic insulation retrofits in existing HUD-code manufactured housing in the colder climates of the United States. The list of more than 50 stakeholders who provided input into this needs assessment is provided in Appendix A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit of Blown Attic Insulation in Existing HUD-Code Manufactured Homes: Needs Assessment Report

This needs assessment was conducted by the Washington State University (WSU) Energy Program and Building Science Corporation (BSC), with support from the U.S. Department of Energy's (DOE) Building Technologies Office. The primary goal of this research was to identify moisture durability, energy savings, and savings-to-investment ratio (SIR) research needs related to the retrofit of attic insulation in the DOE Weatherization Assistance Program (WAP). Specifically, manufactured homes that comply with building codes established by the U.S. Department of Housing and Urban Development (HUD) built after 1976 and sited in colder climates. This project assessed current practice of WAP insulation and/or roof venting solutions that improve attic insulation energy savings and durability. WSU and BSC conducted outreach to stakeholders via email, phone, one-on-one interviews, and group meetings designed to inquire about relevant issues that they may have observed. Needs assessment feedback was provided from stakeholders involved with attic insulation retrofits in existing HUD-code manufactured housing in the colder climates of the United States. The list of more than 50 stakeholders who provided input into this needs assessment is provided in Appendix A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Risk Assessment for Marine Vessel Traffic and Wind Energy Development in the Atlantic

The Bureau of Ocean Energy Management (BOEM) is initiating leasing of the seabed for offshore wind energy development on the outer continental shelf (OCS) in the Atlantic from Maine to Florida, with initial development planned for a series of Wind Energy Areas (WEAs) designated by the Department of Interior. Additional wind areas are under development and are currently considered to be Wind Call Areas (WCAs), leasing areas, and other set asides. Some of the proposed sites are located at or near the entrances to major ports, others are located at the seaward terminus of existing Traffic Separation Schemes (TSS), and many of the wind areas occupy locations along historical shipping routes. The siting of offshore wind farms has the potential to affect existing shipping along the Atlantic Coast; modifications to safe-access routes may be required. The United States Coast Guard (USCG) has the authority to ensure navigational safety in U.S. waters. The USCG has undertaken the Atlantic Coast Port Access Study (ACPARS) to assess future port access and navigation needs for the Atlantic coast, at a time when the mix of shipping routes and vessels are likely to change due to factors such as the widening of the Panama Canal and opening of the Arctic Ocean to shipping. The presence of wind turbines off the Atlantic coast has the potential to affect shipping routes and activities. In order to safely incorporate the presence of offshore wind farms into ACPARS, the USCG requires information on the following: the effects of offshore renewable energy infrastructure on potential traffic density; the impacts of offshore wind infrastructure on shipping traffic including rerouting, funneling, and obstructions to navigation; and whether changes to safe access routes for vessels are needed with the installation of offshore wind farms, including modifications to fairways or TSSs. BOEM entered into an Interagency Agreement in August 2012 with the US Department of Energy (DOE) to provide risk assessment expertise to the USCG development of ACPARS and BOEM’s OCS leasing. DOE assigned Pacific Northwest National Laboratory (PNNL) to provide an assessment of navigational safety risks (including collision, contact, grounding, and stranding). PNNL structured the project around several activities: 1) acquisition and processing of Automated Identification System (AIS) data; 2) geospatial analysis to elucidate historical shipping routes; 3) development of a data-driven numerical model to predict vessel movements in the presence of offshore wind farms; 4) enlisting expertise in navigation from an experts’ panel; 5) assessment of navigational risks from the presence of offshore wind farms; and 6) recommendations for changes to the navigation system to accommodate those changes. This report focuses on the activities carried out by PNNL, in close coordination with BOEM and USCG, from August 2012 to November 2013, and indicates the priority actions for additional enhancement to the modeling system to be carried out from December 2013 through November 2014. The body of the report briefly introduces each step of the process, and reports on notable outcomes. Detailed descriptions, computations, and figures that represent each step are included in ten technical appendices.

17 WIND ENERGY↗

Assessment Approach to Advanced Fuel Models

This document constitutes completion of the NEAMS milestone M3MS-21IN0201016, which is titled: Assessment of advanced fuel improvements. In this report we present: (1) simulations of separate effects creep tests for uranium alloy and HT-9; (2) examples of standardizing and updating metallic fuel assessments to include the latest models and key output figures of merit, which is coordinated with LANL to better evaluate advanced models; (3) examples of how the FIPD database at ANL is integrated into metallic fuel assessment cases; and finally (4) documentation of fuel-specific figures of merit and the BISON review process for assessments with best practices for preparing and reviewing finite element simulations in the appendix.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Renewable Energy Resource Assessment Information for the United States

The Renewable Energy Resource Assessment Information for the United States report summarizes the results of nearly 30 national renewable energy resource assessments performed by the U.S. national laboratories since 2012. Included are assessments for solar, wind, biomass, marine, geothermal, and hydropower energy resource technologies. Increased attention is given to the renewable energy resources available near federally recognized Tribal Nations and low-to-moderate income households, where assessed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measurement Acceptance Region (MAR) Assessment Results Based On Sludge Batch 10 Projections from December 2021, February 2022 and August 2022

The Defense Waste Processing Facility (DWPF) is currently preparing to initiate processing of Sludge Batch 10 (SB10), which is comprised of material from Tanks 11H, 13H, 15H, and 26F, Alternate Feed Stock-2 and Sodium Reactor Experiment material from H-Canyon. Frit 473 (8B 2 O 3 -8Li 2 O-5Na 2 O-79SiO 2 , in weight percent) was recommended for sludge-only (SO) and coupled processing with the Salt Waste Processing Facility (SWPF) based on previous assessments of SB10 projections with the DWPF Product Composition Control System (PCCS) glass property models and their associated Measurement Acceptance Region (MAR) constraints. Due to the lower processing rate of Sludge Batch 9 (SB9), the heel in Tank 40 is anticipated to be greater than 40 inches at the projected start of SB10 processing to meet the upcoming Accelerated Basin Deinventory addition dates in Tank 51 for Sludge Batch 11. In December 2021 and February 2022, Savannah River Remediation System Planning provided updated SB10 Tank 40 blend projections based on heels of 74 inches, 84 inches, 94 inches and 103.4 inches. Savannah River Mission Completion (SRMC) subsequently pursued Wash Cycle Y to further reduce the total sulfur in the sludge batch and increase processing flexibility at DWPF. In August 2022, SRMC System Planning provided an updated SB10 Tank 40 blend projection with a 76 inch-heel representing Decant Y2 and 60 kilogallons of bearing water inleakage that is anticipated during the Tank 51 to Tank 40 transfer. The objectives of this task were to: • Determine the impact on the operating windows for SO and coupled processing • Determine whether any composition gaps exist between the already completed SB10 variability study and the reprojected SB10 glass composition region • Compare the SB10 reprojected glass composition region to the DWPF PCCS model development and validation ranges to ensure that compositional gaps do not exist between the data sets. This report documents the results of these evaluations. Calculation-based frit assessments were performed using the DWPF PCCS glass property models and their associated MAR constraints. Evaluated parameters for coupled processing included the following transfer volumes per Sludge Receipt and Adjustment Tank batch: 5700 gallons of Tank 40 sludge, 2400-4500 gallons of the SWPF monosodium titanate (MST) and sludge solids stream, and 15,000 gallons of strip effluent. Based on these MAR assessment results, Frit 473 remains viable for SB10 processing. A target waste loading (WL) of 36% is possible for SO operation and single strike (0.4 g/L MST) coupled processing up to 600 mg/L of SB9 insoluble sludge solids at a nominal transfer volume of ~2800 gallons. Increasing the single strike transfer volume to 4500 gallons may reduce the maximum WL below 40%. Operating windows are 12 percentage points for SO processing and 14-16 percentage points for coupled processing. Frit 625 allows for a target WL of 36% and is acceptable for use during the SB9 to SB10 transition to deplete remaining inventory as needed. Operating windows are 8 percentage points for SO processing and 12-14 percentage points for coupled processing. Predictive PCCS evaluations performed at DWPF will provide insight into batch-specific acceptability at desired WLs for compositions having expected oxide ratios during processing versus the extreme vertices (corner points) evaluated in this study. The reprojected SB10 glass composition region generally overlaps the previously evaluated SB10 variability study composition region. Thus, the minor composition shift of these updated SB10 projections indicates that no additional glasses are necessary to demonstrate acceptability relative to the chemical durability of the Environmental Assessment benchmark glass and predictability using the current PCCS models for durability. Based on a comparison of the PCCS model development and validation data to the reprojected SB10 glass composition region, the viscosity and liquidus temperature models will reliably predict SB10 compositions. No additional glasses are necessary to demonstrate predictability of these models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CARILEC Resilient Energy Community CoP for Cybersecurity Workshop Series: Cybersecurity Assessment Tools [Slides]

For the last several years and in collaboration with CARILEC, USAID and NREL have been working to support cyber resilience at power sector utilities in Latin America and the Caribbean. Direct technical assistance with regional utilities has been a key component of USAID-NREL Partnership activities, and technical assistance has typically included a foundational cybersecurity assessment using NREL's Distributed Energy Resource Cybersecurity Framework (DER-CF) tool. The DER-CF allows organizations to benchmark and evaluate their cybersecurity posture across the areas of Governance, Technical Management, and Physical Security. To complement the activities of the newly created CAREC IT/OT and Cybersecurity Team, this webinar on cybersecurity assessment tools includes an overview of the DER-CF tool and a discussion with regional stakeholders and NREL experts on the DER-CF assessment process and other resources for cybersecurity assessments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incorporating biologically based models into assessments of risk from chemical contaminants

The general approach to assessment of risk from chemical contaminants in drinking water involves three steps: hazard identification, exposure assessment, and dose-response assessment. Traditionally, the risks to humans associated with different levels of a chemical have been derived from the toxic responses observed in animals. It is becoming increasingly clear, however, that further information is needed if risks to humans are to be assessed accurately. Biologically based models help clarify the dose-response relationship and reduce uncertainty.

Review, Tutorial↗

Nutritional status assessment in semiclosed environments: ground-based and space flight studies in humans

Adequate nutrition is critical during long-term spaceflight, as is the ability to easily monitor dietary intake. A comprehensive nutritional status assessment profile was designed for use before, during and after flight. It included assessment of both dietary intake and biochemical markers of nutritional status. A spaceflight food-frequency questionnaire (FFQ) was developed to evaluate intake of key nutrients during spaceflight. The nutritional status assessment protocol was evaluated during two ground-based closed-chamber studies (60 and 91 d; n = 4/study), and was implemented for two astronauts during 4-mo stays on the Mir space station. Ground-based studies indicated that the FFQ, administered daily or weekly, adequately estimated intake of key nutrients. Chamber subjects maintained prechamber energy intake and body weight. Astronauts tended to eat 40--50% of WHO-predicted energy requirements, and lost >10% of preflight body mass. Serum ferritin levels were lower after the chamber stays, despite adequate iron intake. Red blood cell folate concentrations were increased after the chamber studies. Vitamin D stores were decreased by > 40% on chamber egress and after spaceflight. Mir crew members had decreased levels of most nutritional indices, but these are difficult to interpret given the insufficient energy intake and loss of body mass. Spaceflight food systems can provide adequate intake of macronutrients, although, as expected, micronutrient intake is a concern for any closed or semiclosed food system. These data demonstrate the utility and importance of nutritional status assessment during spaceflight and of the FFQ during extended-duration spaceflight.

NASA Center JSC↗

Security Risk Assessment Process for UAS in the NAS CNPC Architecture

This informational paper discusses the risk assessment process conducted to analyze Control and Non-Payload Communications (CNPC) architectures for integrating civil Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). The assessment employs the National Institute of Standards and Technology (NIST) Risk Management framework to identify threats, vulnerabilities, and risks to these architectures and recommends corresponding mitigating security controls. This process builds upon earlier work performed by RTCA Special Committee (SC) 203 and the Federal Aviation Administration (FAA) to roadmap the risk assessment methodology and to identify categories of information security risks that pose a significant impact to aeronautical communications systems. A description of the deviations from the typical process is described in regards to this aeronautical communications system. Due to the sensitive nature of the information, data resulting from the risk assessment pertaining to threats, vulnerabilities, and risks is beyond the scope of this paper

data links↗