Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACOUSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Constraint on the growth factor of the cosmic structure from the damping of the baryon acoustic oscillation signature

We determine a constraint on the growth factor by measuring the damping of the baryon acoustic oscillations in the matter power spectrum using the Sloan digital sky survey luminous red galaxy sample. We obtain an effective upper limit on {sigma}{sub 8}D{sub 1}(z=0.3) using the damping of the baryon acoustic oscillation signature, where {sigma}{sub 8} is the root mean square overdensity in a sphere of radius 8h{sup -1} Mpc and D{sub 1}(z) is the growth factor at redshift z. The above result assumes that other parameters are fixed and the cosmology is taken to be a spatially flat cold dark matter universe with the cosmological constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling scale-dependent bias on the baryonic acoustic scale with the statistics of peaks of Gaussian random fields

Models of galaxy and halo clustering commonly assume that the tracers can be treated as a continuous field locally biased with respect to the underlying mass distribution. In the peak model pioneered by Bardeen et al.[Astrophys. J. 304, 15 (1986)], one considers instead density maxima of the initial, Gaussian mass density field as an approximation to the formation site of virialized objects. In this paper, the peak model is extended in two ways to improve its predictive accuracy. First, we derive the two-point correlation function of initial density peaks up to second order and demonstrate that a peak-background split approach can be applied to obtain the k-independent and k-dependent peak bias factors at all orders. Second, we explore the gravitational evolution of the peak correlation function within the Zel'dovich approximation. We show that the local (Lagrangian) bias approach emerges as a special case of the peak model, in which all bias parameters are scale independent and there is no statistical velocity bias. We apply our formulas to study how the Lagrangian peak biasing, the diffusion due to large scale flows, and the mode coupling due to nonlocal interactions affect the scale dependence of bias from small separations up to the baryon acoustic oscillation (BAO) scale. For 2{sigma} density peaks collapsing at z=0.3, our model predicts a {approx}5% residual scale-dependent bias around the acoustic scale that arises mostly from first order Lagrangian peak biasing (as opposed to second order gravity mode coupling). We also search for a scale dependence of bias in the large scale autocorrelation of massive halos extracted from a very large N-body simulation provided by the MICE Collaboration. For halos with mass M > or approx. 10{sup 14}M{sub {center_dot}/}h, our measurements demonstrate a scale-dependent bias across the BAO feature which is very well reproduced by a prediction based on the peak model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmological implications of baryon acoustic oscillation measurements

Here, we derive constraints on cosmological parameters and tests of dark energy models from the combination of baryon acoustic oscillation (BAO) measurements with cosmic microwave background (CMB) data and a recent reanalysis of Type Ia supernova (SN) data. Particularly, we take advantage of high-precision BAO measurements from galaxy clustering and the Lyman-α forest (LyaF) in the SDSS-III Baryon Oscillation Spectroscopic Survey (BOSS). Treating the BAO scale as an uncalibrated standard ruler, BAO data alone yield a high confidence detection of dark energy; in combination with the CMB angular acoustic scale they further imply a nearly flat universe. Adding the CMB-calibrated physical scale of the sound horizon, the combination of BAO and SN data into an “inverse distance ladder” yields a measurement of H 0 =67.3±1.1 km s -1 Mpc -1 , with 1.7% precision. This measurement assumes standard prerecombination physics but is insensitive to assumptions about dark energy or space curvature, so agreement with CMB-based estimates that assume a flat ΛCDM cosmology is an important corroboration of this minimal cosmological model. For constant dark energy (Λ), our BAO+SN+CMB combination yields matter density Ω m =0.301±0.008 and curvature Ω k =-0.003±0.003. When we allow more general forms of evolving dark energy, the BAO+SN+CMB parameter constraints are always consistent with flat ΛCDM values at ≈1σ. And while the overall χ 2 of model fits is satisfactory, the LyaF BAO measurements are in moderate (2–2.5σ) tension with model predictions. Models with early dark energy that tracks the dominant energy component at high redshift remain consistent with our expansion history constraints, and they yield a higher H 0 and lower matter clustering amplitude, improving agreement with some low redshift observations. Expansion history alone yields an upper limit on the summed mass of neutrino species, Σm ν <0.56 eV (95% confidence), improving to Σm ν <0.25 eV if we include the lensing signal in the Planck CMB power spectrum. In a flat ΛCDM model that allows extra relativistic species, our data combination yields N eff =3.43±0.26; while the LyaF BAO data prefer higher Neff when excluding galaxy BAO, the galaxy BAO alone favor N eff ≈3. Finally, when structure growth is extrapolated forward from the CMB to low redshift, standard dark energy models constrained by our data predict a level of matter clustering that is high compared to most, but not all, observational estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

Dust-acoustic rogue waves in a nonextensive plasma

We present an investigation for the generation of a dust-acoustic rogue wave in a dusty plasma composed of negatively charged dust grains, as well as nonextensive electrons and ions. For this purpose, the reductive perturbation technique is used to obtain a nonlinear Schroedinger equation. The critical wave-number threshold k{sub c}, which indicates where the modulational instability sets in, has been determined precisely for various regimes. Two different behaviors of k{sub c} against the nonextensive parameter q are found. For small k{sub c}, it is found that increasing q would lead to an increase of k{sub c} until q approaches a certain value q{sub c}, then further increase of q beyond q{sub c} decreases the value of k{sub c}. For large k{sub c}, the critical wave-number threshold k{sub c} is always increasing with q. Within the modulational instability region, a random perturbation of the amplitude grows and thus creates dust-acoustic rogue waves. In order to show that the characteristics of the rogue waves are influenced by the plasma parameters, the relevant numerical analysis of the appropriate nonlinear solution is presented. The nonlinear structure, as reported here, could be useful for controlling and maximizing highly energetic pulses in dusty plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of a Polarization Force on Dust Acoustic Waves

The effect of the polarization force acting on the grains in a nonuniform plasma background on the propagation of low-frequency waves in complex (dusty) plasmas is analyzed. It is shown that polarization interaction leads to a renormalization (decrease) of the dust acoustic phase velocity. The effect becomes more pronounced as the grain size increases. Finally, there is a critical grain size above which the dust acoustic waves cannot propagate, but aperiodic (nonpropagating) perturbations form instead.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory Observations of Self-Excited Dust Acoustic Shocks

Repeated, self-excited dust acoustic shock waves (DASWs) have been observed in a dc glow discharge dusty plasma using high-speed video imaging. Two major observations are reported: (1) The self-steepening of a nonlinear dust acoustic wave (DAW) into a saw-tooth wave with sharp gradient in dust density, very similar to those found in numerical solutions of the fully nonlinear fluid equations for a nondispersive DAW [B. Eliasson and P. K. Shukla, Phys. Rev. E 69, 067401 (2004)], and (2) the collision and confluence of two DASWs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anharmonic Eigenvectors and Acoustic Phonon Disappearance in Quantum Paraelectric SrTiO 3

Pronounced anomalies in the SrTiO 3 dynamical structure factor, S(Q,E), including the disappearance of acoustic phonon branches at low temperatures, were uncovered with inelastic neutron scattering (INS) and simulations. The striking effect reflects anharmonic couplings between acoustic and optic phonons and the incipient ferroelectric instability near the quantum critical point. It is rationalized using a first-principles renormalized anharmonic phonon approach, pointing to nonlinear Ti-O hybridization causing unusual changes in real-space phonon eigenvectors, frequencies, group velocities, and scattering phase space. Lastly, our method is general and establishes how T dependences beyond the harmonic regime, assessed by INS mapping of large reciprocal-space volumes, provide real-space insights into anharmonic atomic dynamics near phase transitions.

36 MATERIALS SCIENCE↗

Thermal acoustic excitations with atomic-scale wavelengths in amorphous silicon

The vibrational properties of glasses remain a topic of intense interest due to several unresolved puzzles, including the origin of the Boson peak and the mechanisms of thermal transport. Inelastic scattering measurements have revealed that amorphous solids support collective acoustic excitations with low THz frequencies despite the atomic disorder, but these frequencies are well below most of the thermal vibrational spectrum. Here, we report the observation of acoustic excitations with frequencies up to 10 THz in amorphous silicon. The excitations have atomic-scale wavelengths as short as 6 Å and exist well into the thermal vibrational frequencies. Simulations indicate that these high-frequency waves are supported due to the high group velocity and monatomic composition of a-Si, suggesting that other glasses with these characteristics may also exhibit such excitations. Furthermore, our findings demonstrate that a substantial portion of thermal vibrational modes in amorphous materials can still be described as a phonon gas despite the lack of atomic order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanometer-Scale Acoustic Wave Packets Generated by Stochastic Core-Level Photoionization Events

We demonstrate that the absorption of femtosecond hard x-ray pulses excites quasispherical, high-amplitude, and high-wave-vector coherent acoustic phonon wave packets using an all hard-x-ray pump-probe scattering experiment. The time- and momentum-resolved diffuse scattering signal is consistent with an ensemble of 3D strain wave packets induced by the rapid electron cascade dynamics following photoionization at uncorrelated excitation centers. We quantify key parameters of this process, including the localization size of the stress field and the photon energy conversion efficiency into elastic energy. The parameters are determined by the photoelectron and Auger electron cascade dynamics, as well as the electron-phonon interaction. In particular, we obtain the localization size of the observed strain wave packet to be 1.5 and 2.5 nm for bulk SrTiO 3 and KTaO 3 single crystals, respectively. The results provide crucial information on the mechanism of x-ray energy deposition into matter and shed light on the shortest collective length scales accessible to coherent acoustic phonon generation using x-ray excitation. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Dark Energy Survey: Implications for cosmological expansion models from the final DES baryon acoustic oscillation and supernova data

The Dark Energy Survey (DES) recently released the final results of its two principal probes of the expansion history: Type Ia supernovae (SNe) and baryonic acoustic oscillations (BAO). In this paper, we explore the cosmological implications of these data in combination with external cosmic microwave background (CMB), big bang nucleosynthesis (BBN), and age-of-the-Universe information. The BAO measurement, which is ∼ 2 σ away from Planck ’s Λ CDM predictions, pushes for low values of Ω m compared to Planck, in contrast to SN which prefers a higher value than Planck. We identify several tensions among datasets in the Λ CDM model that cannot be resolved by including either curvature ( k Λ CDM ) or a constant dark energy equation of state ( w CDM ). By combining BAO + SN + CMB despite these mild tensions, we obtain Ω k = - 5.5 - 4.2 + 4.6 × 10 - 3 in k Λ CDM , and w = - 0.94 8 - 0.027 + 0.028 in w CDM . In w CDM , BAO and SN push again in different directions of parameter space, favoring, respectively, w < - 1 and w > - 1 . If we open the parameter space to w 0 w a CDM [where the equation of state of dark energy varies as w ( a ) = w 0 + ( 1 - a ) w a ], all the datasets are mutually more compatible, and we find concordance in the [ w 0 > - 1 , w a < 0 ] quadrant, with BAO pushing for w a < 0 and SN for [ w 0 > - 1 , w a < 0 ] . For DES BAO and SN in combination with Planck -CMB, we find a 3.2 σ deviation from Λ CDM , with w 0 = - 0.67 3 - 0.097 + 0.098 , w a = - 1.3 7 - 0.50 + 0.51 , a Hubble constant of H 0 = 67.8 1 - 0.86 + 0.96 km s - 1 Mpc - 1 , and an abundance of matter of Ω m = 0.310 9 - 0.0099 + 0.0086 . For the combination of all the background cosmological probes considered (including CMB’s angular acoustic scale θ ⋆ ), we still find a deviation of 2.8 σ from Λ CDM in the w 0 - w a plane. Assuming a minimal neutrino mass, this work provides tentative evidence for non- Λ CDM physics, which is consistent with recent claims in support of evolving dark energy, or a source of unknown systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

Reproducible Data Processing Research for the CABRI R.I.A. experiments Acoustic Emission signal analysis

The CABRI facility is an experimental nuclear reactor of the French Atomic Energy Commission (CEA) designed to study the behaviour of fuel rods at high burnup under Reactivity Initiated Accident (R.I.A.) conditions such as the scenario of a control rod ejection. During the experimental phase, the behaviour of the fuel element generates acoustic waves which can be detected by two microphones placed upstream and downstream from the test device. Studies carried out on the last fourteen tests showed the interest in carrying out temporal and spectral analyses on these signals by showing the existence of signatures which can be correlated with physical phenomena. We want presently to return to this rich data in order to have a new point of view by applying modern signal processing methods. Such an antecedent works resumption leads to some difficulties. Although all the raw data are accessible in the form of text files, analyses and graphics representations were not clear in reproducing from the former studies since the people who were in charge of the original work have left the laboratory and it is not easy when time passes, even with our own work, to be able to remember the steps of data manipulations and the exact setup. Thus we decided to consolidate the availability of the data and its manipulation in order to provide a robust data processing workflow to the experimentalists before doing any further investigations. To tackle this issue of strong links between data, treatments and the generation of documents, we adopted a Reproducible Research paradigm. We shall first present the tools chosen in our laboratory to implement this workflow and, then we shall describe the global perception carried out to continue the study of the Acoustic Emission signals recorded by the two microphones during the last fourteen CABRI R.I.A. tests. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In Situ MOVPE Smoothing of Acoustically Spalled GaAs for Substrate Reuse

High material costs, especially for substrates, have limited the widespread adoption of III-V photovoltaics. A potential to reduce this cost is to reuse the III-V substrate via acoustic spalling, however this technique can leave a rough surface, hindering subsequent device performance. This research investigates the potential of using metalorganic vapor-phase epitaxy growth as a buffer layer to smooth the surface of acoustically spalled germanium and gallium arsenide (GaAs) substrates for improved III-V photovoltaic cell yield and performance, while retaining the maximum number of reuses of a substrate. Three potential smoothing layers were explored: lightly doped C:GaAs, highly doped Se:GaInP, and lightly doped Se:GaInP. C:GaAs showed the most promise as a smoothing layer, while Se:GaInP tended to conform to the underlying morphology, potentially increasing roughness in some areas. Utilizing 5 ..mu..m of C:GaAs as a planarizing buffer increased the average efficiency (without an antireflection coating) from an as-spalled baseline from 2.1% to 4.9% and performing a 5-min 30 degrees C 8:1:1 H2SO4:H2O2:H2O etch prior to a 5 ..mu..m of C:GaAs as a planarizing buffer further increased efficiency to 11.1%.

14 SOLAR ENERGY↗

An 860 MHz Wireless Surface Acoustic Wave Sensor with a Metal-Organic Framework Sensing Layer for CO2 and CH4

Wireless and passive surface acoustic wave (SAW) devices with nanoporous metal-organic framework (MOF) sensing layers are attractive gas sensors for applications in many fields such as energy industries and air pollution control. Here, we report on enhancing the sensitivity and detection limit of zeolitic imidazolate framework-8 (ZIF-8) MOF-coated SAW reflective delay line mass sensors by increasing the operating frequency for sensitive detection of carbon dioxide (CO2) and methane (CH4) at ambient conditions. In particular, we show at least four times higher sensitivity of an 860 MHz (4-μm periodicity) SAW reflective delay line coated with a 240 nm thick ZIF-8 compared to the sensitivity of a 430 MHz (8-μm periodicity) otherwise identical sensor device to the targeted gases. The detection limits of the higher frequency wireless devices for CO2 and CH4 were estimated to be 0.91 vol-% and 7.01 vol-%, respectively. The enhanced sensitivity for higher frequency devices is explained in terms of the frequency dependent acoustic wave energy confinement.

Devkota, Jagannath↗

Quench Detection for High-Temperature Superconductor Conductors Using Acoustic Thermometry

Detecting local heat-dissipating zones in high-temperature superconductor (HTS) magnets is a challenging task due to slow propagation of such zones in HTS conductors. For long conductor lengths, voltage-based methods may not provide a sufficient sensitivity or redundancy, and therefore nonvoltage-based detection alternatives are being sought. One of those is the recently proposed method of Eigen Frequency Thermometry (EFT), which is an active acoustic technique for a fast and nonintrusive detection of 'hot spots,' utilizing temperature dependence of the conductor elastic moduli. In this work, we demonstrate the efficiency of EFT for detecting localized heating in a 1.2-m-long sample of REBCO tape immersed in liquid nitrogen, and benchmark sensitivity of the acoustic detection with respect to voltage, hot spot temperature, and power dissipation in the conductor. Modifying the original technique for differential mode of operation enables a much improved sensitivity, and adds a hot spot localization capability. Furthermore, we adapt this technique to subscale coils wound with REBCO CORC conductor built in the framework of U.S. Magnet Development Program. A successful thermal-based detection of dissipation onset at the critical current for a two-layer canted CORC dipole assembly is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Langasite Surface Acoustic Wave Sensors: Fabrication and Testing

We report on the development of harsh-environment surface acoustic wave sensors for wired and wireless operation. Surface acoustic wave devices with an interdigitated transducer emitter and multiple reflectors were fabricated on langasite substrates. Both wired and wireless temperature sensing was demonstrated using radar-mode (pulse) detection. Temperature resolution of better than ±0.5°C was achieved between 200°C and 600°C. Oxygen sensing was achieved by depositing a layer of ZnO on the propagation path. Although the ZnO layer caused additional attenuation of the surface wave, oxygen sensing was accomplished at temperatures up to 700°C. The results indicate that langasite SAW devices are a potential solution for harsh-environment gas and temperature sensing.

47 OTHER INSTRUMENTATION↗

Detecting thermal crack growth on a large additive manufactured structure using acoustic emission

Large format additive manufacturing (LFAM) proved to have a great potential to become an adjacent technology to traditional manufacturing methods. One of the sectors LFAM is targeting is rapid tool/mold development for composites. This includes large mold structures used for high-temperature molding techniques (in-oven or autoclave). Although, these large printed structures (reaching hundreds of pounds) develop thermal-residual stress during cool-down and can eventually crack, turning the structure into waste. Acoustic emission (AE), a passive non-intrusive global nondestructive evaluation (NDE) technique, was used to monitor crack growth and can provide the right tools that can be used for feedback loop for corrective action. This research performs thermal testing on a large AM mold with preexisting cracks, in an attempt to monitor crack growth using AE. AE was able to detect, identify and locate the crack source by means of acoustic features, waveform characteristics, spectrum analysis, and difference in arrival times.

Spencer, Ryan↗

A simulation technique for 3D MR-guided acoustic radiation force imaging

Purpose: In magnetic resonance-guided focused ultrasound (MRgFUS) therapies, the in situ characterization of the focal spot location and quality is critical. MR acoustic radiation force imaging (MR-ARFI) is a technique that measures the tissue displacement caused by the radiation force exerted by the ultrasound beam. This work presents a new technique to model the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model. Methods: When a steady-state point-source force acts internally in an infinite homogeneous medium, the displacement of the material in all directions is given by the Somigliana elastostatic tensor. The radiation force field, which is caused by absorption and reflection of the incident ultrasound intensity pattern, will be spatially distributed, and the tensor formulation takes the form of a convolution of a 3D Green’s function with the force field. The dynamic accumulation of MR phase during the ultrasound pulse can be theoretically accounted for through a time-of-arrival weighting of the Green’s function. This theoretical model was evaluated experimentally in gelatin phantoms of varied stiffness (125-, 175-, and 250-bloom). The acoustic and mechanical properties of the phantoms used as parameters of the model were measured using independent techniques. Displacements at focal depths of 30- and 45-mm in the phantoms were measured by a 3D spin echo MR-ARFI segmented-EPI sequence. Results: The simulated displacements agreed with the MR-ARFI measured displacements for all bloom values and focal depths with a normalized RMS difference of 0.055 (range 0.028–0.12). The displacement magnitude decreased and the displacement pattern broadened with increased bloom value for both focal depths, as predicted by the theory. Conclusions: A new technique that models the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model theory has been rigorously validated through comparison with experimentally obtained 3D displacement data in homogeneous gelatin phantoms using a 3D MR-ARFI sequence. The agreement of the experimentally measured and simulated results demonstrates the potential to use MR-ARFI displacement data in MRgFUS therapies.

60 APPLIED LIFE SCIENCES↗

Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections

Purpose: Experimentally verify a previously described technique for performing passive acoustic imaging through an intact human skull using noninvasive, computed tomography (CT)-based aberration corrections Jones et al. [Phys. Med. Biol. 58, 4981–5005 (2013)]. Methods: A sparse hemispherical receiver array (30 cm diameter) consisting of 128 piezoceramic discs (2.5 mm diameter, 612 kHz center frequency) was used to passively listen through ex vivo human skullcaps (n = 4) to acoustic emissions from a narrow-band fixed source (1 mm diameter, 516 kHz center frequency) and from ultrasound-stimulated (5 cycle bursts, 1 Hz pulse repetition frequency, estimated in situ peak negative pressure 0.11–0.33 MPa, 306 kHz driving frequency) Definity™ microbubbles flowing through a thin-walled tube phantom. Initial in vivo feasibility testing of the method was performed. The performance of the method was assessed through comparisons to images generated without skull corrections, with invasive source-based corrections, and with water-path control images. Results: For source locations at least 25 mm from the inner skull surface, the modified reconstruction algorithm successfully restored a single focus within the skull cavity at a location within 1.25 mm from the true position of the narrow-band source. The results obtained from imaging single bubbles are in good agreement with numerical simulations of point source emitters and the authors’ previous experimental measurements using source-based skull corrections O’Reilly et al. [IEEE Trans. Biomed. Eng. 61, 1285–1294 (2014)]. In a rat model, microbubble activity was mapped through an intact human skull at pressure levels below and above the threshold for focused ultrasound-induced blood–brain barrier opening. During bursts that led to coherent bubble activity, the location of maximum intensity in images generated with CT-based skull corrections was found to deviate by less than 1 mm, on average, from the position obtained using source-based corrections. Conclusions: Taken together, these results demonstrate the feasibility of using the method to guide bubble-mediated ultrasound therapies in the brain. The technique may also have application in ultrasound-based cerebral angiography.

60 APPLIED LIFE SCIENCES↗