Dynamic Modeling of Full Converter Adjustable-speed Pumped Storage Hydropower (FC AS-PSH)

Full converter adjustable-speed pumped storage hydropower (FC AS-PSH) technology, as one of advanced-PSH technology, is developed from wind turbine technology. By making the synchronous machine connect to the grid through a full-size converter, FC AS-PSH has a wider adjustment range of speed and a better reactive power control capability compared with a doubly-fed asynchronous generator AS-PSH technology. When it plays as an energy backup in the power system, FC AS-PSH can provide a much faster response than conventional-PSH (C-PSH) which makes this technology provide better ancillary service for a high renewable penetrated system. In this paper, the dynamic modeling of FC AS-PSH is fully studied. We develop a detailed model of this technology in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform. Especially, the first governor model is developed based on the Engineer’s Program Control Language (EPCL) user-defined model in this platform. All operation modes are validated and studied under a system contingency. Besides, comparison cases between FC AS-PSH and C-PSH are studied to show advantages providing from FC AS-PSH when it works with renewable energy.

50 EE - Wind and Water Power Program - Water (EE-4↗

Hydrogen Generation Through Renewable Energy Sources at the NASA Glenn Research Center

An evaluation of the potential for generating high pressure, high purity hydrogen at the NASA Glenn Research Center (GRC) was performed. This evaluation was based on producing hydrogen utilizing a prototype Hamilton Standard electrolyzer that is capable of producing hydrogen at 3000 psi. The present state of the electrolyzer system was determined to identify the refurbishment requirements. The power for operating the electrolyzer would be produced through renewable power sources. Both wind and solar were considered in the analysis. The solar power production capability was based on the existing solar array field located at NASA GRC. The refurbishment and upgrade potential of the array field was determined and the array output was analyzed with various levels of upgrades throughout the year. The total available monthly and yearly energy from the array was determined. A wind turbine was also sized for operation. This sizing evaluated the wind potential at the site and produced an operational design point for the wind turbine. Commercially available wind turbines were evaluated to determine their applicability to this site. The system installation and power integration were also addressed. This included items such as housing the electrolyzer, power management, water supply, gas storage, cooling and hydrogen dispensing.

Colozza, Anthony↗

A systematic evaluation of wind's capacity credit in the Western United States

Abstract The degree to which wind energy can contribute to the capacity needed to meet resource adequacy requirements, also known as capacity credit (CC), can be impacted by many factors. The CC varies regionally with wind resource and correlation to net load and may also vary with wind technology (land‐based versus offshore) and turbine specifications. We use a probabilistic resource adequacy tool to systematically assess the CC of multiple technologies for near‐term wind deployment across the Western US power system to help inform planning decisions. We find that wind CC varies by weather year and location but averages 16% for land‐based turbines and 41% for offshore turbines, with large regional variations. The average wind CC increases to 20% for land‐based and 53% for offshore when considering only the sites in the top 25th percentile of capacity factor. The CC of land‐based wind is generally lower than its capacity factor, which indicates a low correlation of generation to system needs. However, offshore wind shows a substantially higher CC, which is driven by not only a higher capacity factor but also a greater correlation with system needs.

17 WIND ENERGY↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗

High-frequency heating of the solar wind triggered by low-frequency turbulence

The fast solar wind’s high speeds and non-thermal features require that considerable heating occurs well above the Sun’s surface. Two leading theories seem incompatible: low-frequency ‘Alfvénic’ turbulence, which transports energy outwards and is observed ubiquitously by spacecraft but seems insufficient to explain the observed dominance of ion over electron heating; and high-frequency ion-cyclotron waves, which explain the non-thermal heating of ions but lack an obvious source. Here we argue that the recently proposed ‘helicity barrier’ effect, which limits electron heating by inhibiting the turbulent cascade of energy to the smallest scales, can unify these two paradigms. Our six-dimensional simulations show how the helicity barrier causes the large-scale energy to grow through time, generating small parallel scales and high-frequency ion-cyclotron-wave heating from low-frequency turbulence, while simultaneously explaining various other long-standing observational puzzles. Furthermore, the predicted causal link between plasma expansion and the ion-to-electron heating ratio suggests that the helicity barrier could contribute to key observed differences between fast and slow wind streams.

79 ASTRONOMY AND ASTROPHYSICS↗

Small UAV Flight Planning in Urban Environments

This work proposes a fast algorithm for generating obstacle-free and wind-efficient flight paths at a constant above-ground-level altitude in urban environments because a fast flight path planning algorithm is an essential function or service needed for enabling small unmanned aerial vehicle (sUAV) to operate in urban environments within Class G airspace. The proposed method first converts the 3D path planning problem to a 2D problem by constructing an obstacle map at a given above-ground-level altitude. A quad-tree decomposition is then used to build a search space in terms of obstacle occupancy and wind difference. The wind cost of traveling through each cell is defined based on energy consumption under various wind conditions. A repulsive potential is also adopted to make sure that the flight plans stay away from obstacles. The Theta* search algorithm, a variant of A* algorithm, is applied to mitigate the path angle change constraints introduced by grid-based graphs. With the Theta* and postsmoothing techniques, an obstacle-free, wind efficient, and constant above-ground-level flight plan can be quickly generated for sUAV operations in urban environments while meeting the lateral path angle constraints. The results showed that the path planning algorithm is efficient and can be finished within several seconds. With a proper choice of wind coefficient, the proposed path planning algorithm outperforms the multiple-shooting trajectory optimization method even in an obstacle-free environment. With the flexibility of incorporating other geo-related costs and computation efficiency, the proposed algorithm shows the potential for real-time flight path planning in complex urban environments.

Path planning↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

A time‐varying formulation of the curled wake model within the FAST.Farm framework

Abstract In this article, we present a time‐varying formulation of the curled wake model that we implemented in FAST.Farm. The curled wake model, originally developed for steady‐state conditions, is used to produce realistic wake profiles behind a wind turbine in yawed (or skewed) conditions. We begin by introducing the key elements of the FAST.Farm framework. Then, after briefly summarizing the original wake dynamics formulation of FAST.Farm based on a polar wake profile, we present the new time‐varying formulation of the curled wake model, compare the two, and highlight the differences with the original curled wake model. After discussing some implementation details, we present different applications with increasing levels of complexity: single turbine with uniform and turbulent inflow, fixed and transient yaw, and multiple turbines. We verify our results using the original FAST.Farm implementation and large‐eddy simulations. The results with the new curled wake model are improved compared to the original implementation, as they include cross‐flow velocities and wake asymmetry. Yet, large‐eddy simulation results show a more pronounced lateral convection of the wake and a stronger concentration of vorticity at the top vortex. The new curled wake implementation in FAST.Farm should enable the calculation of not only generator power but also wind turbine structural loads for applications involving intentional or unintentional skewed flow and wind‐farm control involving wake steering.

17 WIND ENERGY↗

Making coal relevant for small scale applications: Modular gasification for syngas/engine CHP applications in challenging environments

Small-scale coal gasification technology, coupled to a reciprocating engine generator, has the potential for making coal a cost competitive resource for meeting the flexible energy needs and resiliency requirements of utilities across the United States. To maintain grid stability and reliability, electrical generation must be regulated to match the load at the proper voltage and frequency. With the expansion of intermittent sources into the grid, such as wind and solar, frequency and voltage regulation become increasingly important and challenging. This work presents the results of a Front End Engineering Design (FEED) effort to detail the engineering and preliminary economics of a small-scale, air blown, fixed-bed gasification process, operating at near-atmospheric pressure, with gas cleanup to provide syngas and pyrolysis liquid fuels for use in reciprocating engine generators for combined heat and power at the University of Alaska Fairbanks. A very detailed assessment of capital and operating costs allows the evaluation of a levelized cost of electricity of 208.06 $/MWh, which can be reduced through the selling of by-products (steam for heating purposes and pyrolysis liquids to be used for power generation in an existing diesel engine). Here, a combined sensitivity analysis, based on the Monte Carlo approach, has been carried out to evaluate the effects of the uncertainties (capital and operating costs and plant annual availability) on the LCOE.

01 COAL, LIGNITE, AND PEAT↗

PLUSWIND Derived Data

This dataset consists of annual CSV files containing multiple sources of modeled, hourly wind speeds and generation. For complete information about this dataset, including validation of modeled generation versus recorded generation, please see the Scientific Data article: Millstein, D., Jeong, S., Ancell, A., & Wiser, R. (2023). A database of hourly wind speed and modeled generation for US wind plants based on three meteorological models. Scientific Data, 10(1), 883. https://doi.org/10.1038/s41597-023-02804-w

17 WIND ENERGY↗

Grand challenges and opportunities in next-generation batteries and technologies

The development of advanced Li-ion batteries and technologies generally addresses one of four objectives: 1) create a higher volumetric energy density and/or specific energy/power, 2) impart intrinsically safer chemistry, 3) produce speedier charging, and 4) utilize less expensive batteries but with competitive/near-competitive performances. Certainly, other factors can play a role as well, dependent on the type of market targeted and the availability of global supplies; however, for widespread adoption, the above points/criteria remain salient. Li-ion is commercially well entrenched in industry for communication and transportation (EV) applications. Nowadays, slight iterations, mostly electrolyte-defined, are incrementally improving safety, cost, and cycle or calendar life. The last point, calendar life, is one that is often overlooked for very high-energy dense Li-ion batteries, because of their reactivity at higher charge (OCV conditions) and elevated temperatures. While cycle life is debated with respect to capacity/energy performance decline, attempts to re-purpose the battery itself or recycle the internal chemical constituents at end of life have considerably grown in the field. Hopefully, energy-neutral processes are also considered in the recycling loop. Nevertheless, the energy storage arena is quite large, and this pursuit hinges on pushing the field in one of many directions, toward loftier objectives. The pursuit of next-generation batteries and technologies must thus delve deeper into new and novel chemistry and electrochemistry to create a world with a neutral, carbon-free environment, and one that is solely sufficient on energy-producing renewables such as the Sun and wind-derived means. The application of electricity and chemistry within our world is thus a 21st century opus.

25 ENERGY STORAGE↗

Plans and status of the NASA-Lewis Research Center wind energy project

Wind energy is investigated as a source of energy. The wind energy program that is managed by the NASA-Lewis Research Center is described. The Lewis Research Center's Wind Power Office, its organization, plans, and status are discussed. Major elements of the wind power project included are: an experimental 100 kW wind-turbine generator; first generation industry-built and user-operated wind turbine generators; and supporting research and technology tasks.

Thomas, R.↗

Comparison of broadband noise mechanisms, analyses, and experiments on helicopters, propellers, and wind turbines

Experimental data on broadband noise from airfoils are compared, together with analytical methods, in order to identify the mechanisms of noise emission. Rotor noise is categorized into discrete frequency, impulsive, and broadband components, the last having a continuous spectrum originating from a random source. The results of computer simulations of different rotor blade types which produce broadband noise were compared with experimental data and among themselves in terms of predictions of the spectra obtained. Consideration was given to the overall sound pressure level, unsteady turbulence forces, rotational forces, inflow turbulence, self-generated turbulence, and turbulence in the flow. Data are presented for a helicopter rotor and light aircraft propeller. The most significant source was found to be inflow turbulence induced lift fluctuations in helicopter rotors and boundary layer trailing edge noise on large wind energy conversion systems

George, A. R.↗

Hybrid-RL-MPC4CLR (Hybird-Reinforcement-Learning-Model-Predictive-Control-for-Reserve-Policy-Assisted-Critical-Load-Restoration-in-Distribution-Grids)

Hybrid-RL-MPC4CLR was developed as a hybrid controller for active distribution grid critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. The RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while the MPC models grid operations incorporating the RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. The developers formulated the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The software is developed using various software packages in Python. The MPC's optimal power flow (OPF) model is implemented using the Pyomo package, the RL simulation environment is implemented using the MPC simulation with various scenarios of renewable energy and load demand profiles and power outage beginning times, based on the OpenAI Gym framework. The RL agent training is performed using the RLlib Ray package. The RL algorithm is trained offline using historical forecasts of renewable generation and load demand profiles. Simulation analysis and performance tests are conducted using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery.

Eseye, Abinet Tesfaye↗

Modification of wind turbine wakes by large-scale, convective atmospheric boundary layer structures

In this study, we consider the impact of large-scale, convective structures in an unstable atmospheric boundary layer on wind turbine wakes. Simulation data from a high-fidelity large-eddy simulation (LES) of the AWAKEN wind farm site matching unstable atmospheric conditions were analyzed, and both turbine performance and wake behavior were affected based on their location relative to the convective structures. Turbines located in updraft regions of the flow experienced lower inflow velocity and generated less power, but their wakes were observed to recover faster and saw greater turbulent kinetic energy mixing higher in the boundary layer. The opposite effect was found for turbines in the downdraft regions of the convective structures. A simplified model of this wake behavior was also developed based on a two-dimensional k–ε Reynolds-Averaged Navier–Stokes formulation. This simplified model included the effects of vertical transport, but could be efficiently solved as a parabolic system, and was found to capture similar wake modifications observed in the high-fidelity LES computations.

16 TIDAL AND WAVE POWER↗

The Circular Economy Life Cycle Assessment and Visualization Framework: A Multistate Case Study of Wind Blade Circularity in United States

A circular economy (CE) aims to decouple human activities from economic activities and resource use, and its overall goal is reducing or avoiding negative environmental externalities. The newly developed Circular Economy Lifecycle Assessment and Visualization (CELAVI) framework simulates changes in supply chain environmental impacts as it transitions toward circularity. This study expands CELAVI by incorporating detailed spatial resolution and real-world road routes connecting all facilities within the system. The case study on end-of-life decision making of wind turbine blades in the states of Iowa and Missouri explores how supply chain circularity and environmental impacts are affected by pathway costs and level of wind turbine installations. It demonstrates how high circularity costs might be beneficial for circularity transitions given revenue generated from circular pathways. Finally, impacts have important contributions to the supply chain design and thus show the importance of including detailed spatial resolution in CELAVI and CE studies in general.

circular economy↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Evaluating the Interactions Between Variable Renewable Energy and Diurnal Storage

Cost declines and growing deployment of photovoltaic (PV), wind, and storage have led to increasing interest in the potential interactions of these three technologies as their role in the power system grows. In this work we enhance a national-scale capacity expansion model to evaluate how PV, wind, and storage interact in the evolution of the power system. Importantly, the modeling framework captures interactions in both investments and operations. Through this work we identify significant synergies between PV and storage. Scenarios with more PV always have more storage, and scenarios with more storage always have more PV. This synergy is due to the diurnal alignment of PV generation with 4-8 hour storage, and to the ability of PV to narrow system peaks to allow shorter-duration storage to serve as a peaking resource. Interactions between wind and storage are less pronounced, though we do observe that longer-duration storage resources appear to provide greater value for wind.