Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage indices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Closed cycle MHD power generation experiments using a helium-cesium working fluid in the NASA Lewis Facility

The MHD channel in the NASA Lewis Research Center was redesigned and used in closed cycle power generation experiments with a helium-cesium working fluid. The cross sectional dimensions of the channel were reduced to 5 by 16.5 cm to allow operation over a variety of conditions. Experiments have been run at temperatures of 1900-2100 K and Mach numbers from 0.3 to 0.55 in argon and 0.2 in helium. Improvements in Hall voltage isolation and seed vaporization techniques have resulted in significant improvements in performance. Typical values obtained with helium are Faraday open circuit voltage 141 V (92% of uBh) at a magnetic field strength of 1.7 T, power outputs of 2.2 kw for tests with 28 electrodes and 2.1 kw for tests with 17 electrodes. Power densities of 0.6 MW/cu m and Hall fields of about 1100 V/m were obtained in the tests with 17 electrodes, representing a factor of 18 improvement over previously reported results. The V-I curves and current distribution data indicate that while near ideal equilibrium performance is obtained under some conditions, no nonequilibrium power has been generated to date.

Sovie, R. J.↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molecular Design of a Highly Stable Single-Ion Conducting Polymer Gel Electrolyte

Single-ion conducting (SIC) polymer electrolytes with a high Li transference number ( t Li + ) have shown the capability to enable enhanced battery performance and safety by avoiding liquid–electrolyte leakage and suppressing Li dendrite formation. However, issues of insufficient ionic conductivity, low electrochemical stability, and poor polymer/electrode interfacial contact have greatly hindered their commercial use. In this work, a Li-containing boron-centered fluorinated SIC polymer gel electrolyte (LiBFSIE) was rationally designed to achieve a high t Li + and high electrochemical stability. Owing to the low dissociation energy of the boron-centered anion and Li + , the as-prepared LiBFSIE exhibited an ionic conductivity of 2 × 10 –4 S/cm at 35 °C, which is exclusively contributed by Li ions owing to a high t Li + of 0.93. Both simulation and experimental approaches were applied to investigate the ion diffusion and concentration gradient in the LiBFSIE and non-cross-linked dual-ion systems. Typical rectangular Li stripping/plating voltage profiles demonstrated the uniform Li deposition assisted by LiBFSIE. The interfacial contact and electrolyte infiltration were further optimized with an in situ UV–vis-initiated polymerization method together with the electrode materials. By virtue of the high electrochemical stability of LiBFSIE, the cells achieved a promising average Coulombic efficiency of 99.95% over 200 cycles, which is higher than that of liquid–electrolyte-based cells. No obvious capacity fading was observed, indicating the long-term stability of LiBFSIE for lithium metal batteries.

36 MATERIALS SCIENCE↗

Peer-to-Peer Energy Trading under Network Constraints Based on Generalized Fast Dual Ascent

We report the wide deployment of renewable energy resources, combined with a more proactive demand-side management, is inducing a new paradigm in both power system operation and electricity market trading, which especially boosts the emergence of the peer-to-peer (P2P) market. A more flexible local market mechanism is highly desirable in response to fast changes in renewable power generation at the distribution network level. Moreover, large-scale implementation of P2P energy trading inevitably affects the secure and economic operation of the distribution network. This paper presents a new P2P electricity trading framework with distribution network security constraints considered using the generalized fast dual ascent method. First, an event-driven local P2P market framework is presented to facilitate short-term or immediate local energy transactions. Then, the sensitivity analysis of nodal voltage and network loss with respect to nodal power injections is used to evaluate the impacts of P2P transactions on the distribution network, which ensures the secure operation of the distribution system. Thereby, the external operational constraints are internalized, and the cost of P2P energy trading can be appropriately allocated in an endogenous way. Moreover, a generalized fast dual ascent method is employed to implement distributed market-clearing efficiently. Finally, numerical results indicate that the proposed model could guarantee secure operation of the distribution system with P2P energy trading, and the solution method enjoys good convergence performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linear phase demodulator including a phase locked loop with auxiliary feedback loop

A phase modulated wave that may have no carrier power is demodulated by a phase locked loop including a phase detector for deriving an A.C. data output signal having a magnitude and a phase indicative of the phase of the modulated wave. A feedback loop responsive to the data output signal restores power to the carrier frequency component to the loop. In one embodiment, the feedback loop includes a phase modulator responsive to the phase modulated wave and the data output signal. In a second embodiment, carrier frequency power is restored by differentiating the data output signal and supplying the differentiated signal to an input of a voltage controlled oscillator included in the phase locked loop.

Rippy, R. R.↗

Direct measurement of lower atmospheric vertical potential differences

A high impedance system has been developed to make direct measurements of the atmospheric potential difference up to several thousand feet. A tethered balloon flown from Wallops Island, Virginia was used to loft a high voltage, insulated wire and a conducting collector in a test flight to 550 meters for two days of experiments in October 1980. The balloon was equipped with a payload to measure exact altitude, wind speed and direction, and other meteorological parameters. Electric potentials of 170,000 volts at 550 meters were measured. The collected currents which could be drawn through the wire by grounding the lower end were in the 10 microamp range indicating a system impedance of about 10 to the 10th ohms. This paper describes the apparatus and details of these measurements.

Holzworth, R. H.↗

Recovery of damage in rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays

This paper reports on the recovery properties of rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays. The results indicated that complex recovery properties controlled the damage sensitivities of the tested parts. The results also indicated that damage sensitivities depended on dose rate, total dose, supply bias, gate bias, transistor type, radiation source, and particle energy. The complex nature of these dependencies make interpretation of LSI device performance in space (exposure to entire electron and proton spectra) difficult, if not impossible, without respective ground tests and analyses. Complete recovery of n-channel shifts was observed, in some cases within hours after irradiation, with equilibrium values of threshold voltages greater than their pre-irradiation values. This effect depended on total dose, radiation source, and gate bias during exposure. In contrast, the p-channel shifts recovered only 20 percent within 30 days after irradiation.

Brucker, G. J.↗

Far-field brainstem responses evoked by vestibular and auditory stimuli exhibit increases in interpeak latency as brain temperature is decreased

The effect of decreasing of brain temperature on the brainstem auditory evoked response (BAER) in rats was investigated. Voltage pulses, applied to a piezoelectric crystal attached to the skull, were used to evoke stimuli in the auditory system by means of bone-conducted vibrations. The responses were recorded at 37 C and 34 C brain temperatures. The peaks of the BAER recorded at 34 C were delayed in comparison with the peaks from the 37 C wave, and the later peaks were more delayed than the earlier peaks. These results indicate that an increase in the interpeak latency occurs as the brain temperature is decreased. Preliminary experiments, in which responses to brief angular acceleration were used to measure the brainstem vestibular evoked response (BVER), have also indicated increases in the interpeak latency in response to the lowering of brain temperature.

Hoffman, L. F.↗

Investigation of a repetitive pulsed electrothermal thruster

A pulsed electrothermal (PET) thruster with 1000:1 ratio nozzle is tested in a repetitive mode on water propellant. The thruster is driven by a 60J pulse forming network at repetition rates up to 10 Hz (600W). The pulse forming network has a .31 ohm impedance, well matched to the capillary discharge resistance of .40 ohm, and is directly coupled to the thruster electrodes without a switch. The discharge is initiated by high voltage breakdown, typically at 2500V, through the water vapor in the interelectrode gap. Water is injected as a jet through a .37 mm orifice on the thruster axis. Thruster voltage, current and impulse bit are recorded for several seconds at various power supply currents. Thruster to power ratio is typically T/P = .07 N/kW. Tank background pressure precludes direct measurement of exhaust velocity which is inferred from calculated pressure and temperature in the discharge to be about 14 km/sec. Efficiency, based on this velocity and measured T/P is .54 + or - .07. Thruster ablation is zero at the throat and becomes measurable further upstream, indicating that radiative ablation is occurring late in the pulse.

Burton, R. L.↗

Preliminary Testing of Electrolytic Silver Ion Generation for Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of imparting biocidal silver into potable water on exploration spacecraft. This method of water disinfection is used commercially in hospitals and marine vessels, but the spacecraft application poses unique challenges such as low water conductivity, increased importance of electrode longevity, and an interface with other systems that may be sensitive to any particles released in the electrolysis process. Testing has shown that due to the low conductivity of the water, the electroactive area of the cell can be scaled linearly to achieve a target electrolysis current despite the general non-linearity of electrochemical systems. More importantly, however, the low conductivity dictates that a large electroactive area and minimal electrode gap be employed in the design. Furthermore, thermodynamic considerations suggest that a low applied voltage is necessary to avoid undesired electrode reactions that could negatively impact long-term performance. Preliminary testing of long-term electrode health suggests that anodic oxide formation may not present as significant a challenge as anticipated; however, further testing in a system closed to the atmosphere is required to rule out the influence of atmospheric CO2 on the pH of the process water. Comparison of filtered and unfiltered silver concentration measurements indicates that release of particles larger than 0.2 μm was negligible in this preliminary test. A test article has been developed to facilitate further testing of silver electrolysis, which continues to be a candidate technology for spacecraft potable water disinfection.

silver↗

Fast and Scalable Synthesis of LiNi 0.5 Mn 1.5 O 4 Cathode by Sol–Gel-Assisted Microwave Sintering

High-voltage spinel LiNi 0.5 Mn 1.5 O 4 (LNMO) is a promising cathode material for high-energy-density and high-power-density lithium-ion batteries (LIBs). The high cost of the currently available LIBs needs to be addressed urgently for wide application in the transport sector (electric vehicles, buses) and large-scale energy storage systems (ESS). Of significance, herein, novel fast and scalable microwave-assisted synthesis of LNMO is reported, which leads to a production cost cut. X-ray diffraction (XRD) analysis confirms the formation of the desired phase with high crystallinity. Field emission scanning (FE-SEM) and transmission electron microscopy (TEM) analyses indicate that the synthesized phase is of nanometric size (50–150 nm) due to an extremely short sintering time (20 min). The material synthesized at 750 °C shows a higher initial discharge capacity (130 mA h g -1 ) than that synthesized at 650 °C (115 mA h g -1 ). The materials heat treated at higher temperatures show better electrochemical performance in terms of initial capacity, rate capability, and improved cycling. The improved electrochemical performance of LNMO at 750 °C is attributed to the formation of a stable crystal structure, low charge transfer resistance at the electrode/electrolyte interface, high electrical conductivity due to the presence of a disorder structure, and improved ionic diffusivity.

25 ENERGY STORAGE↗

Prognostic health monitoring in switch-mode power supplies with voltage regulation

The system includes a current injection device in electrical communication with the switch mode power supply. The current injection device is positioned to alter the initial, non-zero load current when activated. A prognostic control is in communication with the current injection device, controlling activation of the current injection device. A frequency detector is positioned to receive an output signal from the switch mode power supply and is able to count cycles in a sinusoidal wave within the output signal. An output device is in communication with the frequency detector. The output device outputs a result of the counted cycles, which are indicative of damage to an a remaining useful life of the switch mode power supply.

Hofmeister, James P↗

Probing Heterogeneous Degradation of Catalyst in PEM Fuel Cells under Realistic Automotive Conditions with Multi-Modal Techniques

The heterogeneity of polymer electrolyte fuel cell catalyst degradation is studied under varied relative humidity and types of feed gas. Accelerated stress tests (ASTs) are performed on four membrane electrode assemblies (MEAs) under wet and dry conditions in an air or nitrogen environment for 30 000 square voltage cycles. The largest electrochemically active area loss is observed for MEA under wet conditions in a nitrogen gas environment AST due to constant upper potential limit of 0.95 V and significant water content. The mean Pt particle size is larger for the ASTs under wet conditions compared to dry conditions, and the Pt particle size under land is generally larger than under the channel. Observations from ASTs in both conditions and gas environments indicate that water content promotes Pt particle size growth. ASTs under wet conditions and an air environment show the largest difference in Pt particle size growth for inlet versus outlet and channel versus land, which can be attributed to larger water content at outlet and under land compared to inlet and under channel. From X-ray fluorescence experiments Pt particle size increase is a local phenomenon as Pt loading remains relatively uniform across the MEA.

25 ENERGY STORAGE↗

Gallium vacancy formation in oxygen annealed β-Ga 2 O 3

Here, the formation and character of gallium vacancies (V Ga ) and their complexes in near surface and bulk regions of single crystal β-Ga 2 O 3 were explored using unintentionally doped single crystals grown by the Czochralski method. As-grown and O 2 annealed (up to 1550 °C) samples were investigated using positron annihilation spectroscopy (PAS) to study the top 0.05–6 μm, and also current–voltage measurements and infrared (IR) spectroscopy, with hydrogenated samples to probe V Ga , to study the bulk. After annealing in O 2 > 1000 °C, the β-Ga 2 O 3 resistivity begins increasing, up to ~10 9 Ω cm for 1550 °C treatment, with the top 0.5 mm being many orders of magnitude more resistive. PAS measurements of the top 6 μm (S values) and very near surface 200 nm (diffusion length, L) indicate differential behavior as a function of peak annealing temperature. At least four temperature regimes of behavior are described. V Ga are present in the bulk after growth, but considerable changes occur upon annealing at a temperature ≈1000 °C, where L and S decrease simultaneously, suggesting an increasing defect concentration (L) but a decreasing defect volume (S). Annealing at a temperature ≈1400 °C increases S again, showing an increasing volume concentration of V Ga , with IR absorption showing a large signature of V Ga -2H, indicative of increased V Ga formation that was not present when annealing at a temperature ≈1000 °C. These results suggest that defect changes from annealing in oxygen are depth dependent, and that V Ga configuration may not be the same near the oxygen-exposed surface of the sample and in the bulk.

74 ATOMIC AND MOLECULAR PHYSICS↗

Phase Two of the Array Automated Assembly Task for the Low Cost Solar Array Project

Various top contact metal systems were studied. Only Ti Pd Cu approaches baseline (Ti Pd Ag) quality, but this system shows a lack of long term stability. Aluminum back surface field structures were fabricated and thicknesses of p superscript + material of up to 7.0 microns were achieved with open circuit voltages of 0.59V. A general purpose ultrasonic welder was purchased and tests using various metal foils are under way. During fabrication of the demonstration module, several cells became cracked. Due to redundancy of interconnections, the module was not open circuited but the efficiency was reduced to 8.8%. The broken cell was interconnected with a strap across the back and the efficiency was increased to 11.5%. A cost analysis was made and the results indicate a selling price of $0.56/watt peak (in 1986 with 1975 dollars).

Campbell, R. B.↗

Extending Ion Engine Technology to NEXT and Beyond

Extending ion engine technology beyond the current state-of-the art primary interplanetary electric propulsion system, the 2.3-kW NASA Solar Electric Propulsion Technology and Applications Readiness (NSTAR) system, will require thrusters with improved propellant throughput and total impulse capability. Many of the design choices that culminated in the NSTAR thrusters must be revisited, and their application to next generation ion engine technology must be evaluated. The concept of derating, which was successfully employed in NSTAR, has been applied to the 40 cm NASA Evolutionary Xenon Thruster (NEXT) currently under development at NASA Glenn Research Center (GRC). At 5-kW, NEXT operates with the same average beam current density as NSTAR, and at 10-kW, the peak beam current density is only ten percent greater than NSTAR. The result is that similar Ion optics technology is expected to yield comparable lifetime. Thick-accelerator- grid ion optics are also being tested to realize additional lifetime benefits. A 40-A discharge cathode is being developed for NEXT based on scaling the NSTAR design. Nevertheless, the experiences of the NSTAR ground tests and the thruster on the Deep Space One spacecraft indicate that the discharge cathode wear must be studied experimentally and theoretically to ensure that it meets the lifetime requirements. Although NEXT is in its infancy, investigations have already begun to examine possible modifications to engine design for even higher-power and higher-specific impulse engines. Ion optics using alternate materials such as titanium, graphite, or carbon-carbon composite are currently being investigated due to their low sputter yields at high voltage. To avoid the difficulties encountered using electrodes at high-currents, the use of a microwave-based ion thruster is under investigation for potential high-power ion thruster systems requiring long lifetimes. Additionally, alternative propellants are being considered for applications requiring high-specific impulse (>> 5000 s) and extremely long-life (>> 15,000 hr). Testing requirements make condensable propellants attractive for high-power engines. Although the NSTAR ion engine demonstrated the flight maturity of ion thruster technology, many challenges remain for the development of thrusters with improved propellant throughput and power handling capabilities.

Domonkos, Matthew T.↗

Experimental and simulation study of target biasing effects on plasma transport in linear plasma device MPS-LD

Linear plasma devices (LPDs) are important experimental platforms for investigating plasma–material interactions (PMI). In PMI experiments, it has been found that applying a target bias not only effectively modifies the incident ion energy, but also induces significant changes in the electron density and electron temperature, whereby the evolution of these plasma parameters is primarily governed by plasma transport processes. However, at present, the physical process and mechanism underlying such bias-induced variations remain unclear. In this work, biasing experiments under argon plasma discharge conditions were first carried out on the MPS-LD device. For the corresponding experiments, an electric potential model was newly developed based on the BOUT++ LPD module, enabling self-consistent simulations of plasma transport under biased conditions. Numerical simulations were then performed to reproduce the experimental results and to validate the accuracy of the proposed model. Finally, by combining experimental measurements with numerical simulations, a bias-voltage scan was performed to investigate how the electron density and electron temperature vary with the bias voltage (U bias ). The results show that applying negative bias decreases the target electron density (n e,T ) while increasing the target electron temperature (T e,T ). In contrast, positive bias increases both n e,T and T e,T ; however, at high positive bias, n e,T first reaches a maximum and subsequently decreases with further increases in U bias . The underlying physical mechanisms are analyzed using particle flux, momentum, and energy conservation. It indicates that the applied bias regulates the parallel electric field, thereby changing ion and electron velocities, and consequently affecting the electron density. At high positive bias, the ion velocity is further influenced by ion viscosity, leading to the reversal in n e,T . Meanwhile, the enhanced parallel electric field drives stronger currents, significantly increasing ion–electron frictional work and converting the input bias power into electron energy, which raises the electron temperature. In conclusion, these results contribute to a deeper understanding of the effects and mechanisms of biasing on plasma transport in the MPS-LD device.

BOUT++ simulation↗

PVwindow (Photovoltaic Window Simulator) [SWR-22-01]

PVwindow simulates photovoltaic window properties by allowing the user build stacks of thin film materials that compose the window layers. The only needed inputs are the complex refractive indices and thicknesses of the materials. The software will simulate the optical transmission, front reflection, and back reflection of the stack using the transfer matrix method. Properties specific to PV window optics such as visible transmittance and color are also calculated. The optics code extracts the number of absorbed photons in the PV absorber layer and solves the single diode equation to yield theoretical photovoltaic metrics such as power conversion efficiency, fill factor, open circuit voltage, and short circuit current of the PV window when illuminated at an arbitrary angle or from either side of the stack. The software tool ultimately allows researchers to design photovoltaic windows and simulate their properties. The software also exports files that can be read into LBL Window software or into the EnergyPlus and Open Studio building energy modeling software to determine larger scale energy impacts of PV window integration.

Wheeler, Lance↗