Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Status and expected perfomance of the MAXI mission for the JEM/ISS

MAXI (Monitor of All-sky X-ray Image) is the first payload to be attached on JEM-EF (Kibo exposed facility) of ISS. It provides an all sky X-ray image every ISS orbit. Only with a few weeks scan, MAXI is expected to make a milli-Crab X-ray all sky map excluding bright region around the sun. Thus, MAXI does not only inform X-ray novae and transients rapidly to world astronomers if once they occur, but also observes long-term variability of Galact ic and extra-Galactic X-ray sources. MAXI also provides an X-ray source catalogue at that time with diffuse cosmic X-ray background. MAXI consists of two kinds of detectors, position sensitive gas-proportional counters for 2-30 keV X-rays and CCD cameras for 0.5-10 keV X-rays. All instruments of MAXI are now in final phase of pre-launching tests of their flight modules. We are also carrying out performance tests for X-ray detectors and collimators. Data processing and analysis software including alert system on ground are being developed by mission team. In this paper we report an overview of final instruments of MAXI and capability of MAXI.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron imaging with the short-pulse laser driven neutron source at the TRIDENT Laser Facility

Emerging approaches to short-pulse laser-driven neutron production offer a possible gateway to compact, low cost, and intense broad spectrum sources for a wide variety of applications. They are based on energetic ions, driven by an intense short-pulse laser, interacting with a converter material to produce neutrons via breakup and nuclear reactions. Recent experiments performed with the high-contrast laser at the Trident laser facility of Los Alamos National Laboratory have demonstrated a laser-driven ion acceleration mechanism operating in the regime of relativistic transparency, featuring a volumetric laser-plasma interaction. This mechanism is distinct from previously studied ones that accelerate ions at the laser-target surface. The Trident experiments produced an intense beam of deuterons with an energy distribution extending above 100 MeV. This deuteron beam, when directed at a beryllium converter, produces a forward-directed neutron beam with ~5x10 9 n/sr, in a single laser shot, primarily due to deuteron breakup. The neutron beam has a pulse duration on the order of a few nanoseconds with an energy distribution extending from a few hundreds of keV to almost 80 MeV. For the experiments on neutron-source spot-size measurements, our gated neutron imager was setup to select neutrons in the energy range of 2.5 to 35 MeV. The spot size of neutron emission at the converter was measured by two different imaging techniques, using a knife-edge and a penumbral aperture, in two different experimental campaigns. The neutron-source spot size is measured ~1 mm for both experiments. The measurements and analysis reported here give a spatial characterization for this type of neutron source for the first time. In addition, the forward modeling performed provides an empirical estimate of the spatial characteristics of the deuteron ion-beam. Finally, these experimental observations, taken together, provide essential yet unique data to benchmark and verify theoretical work into the basic acceleration mechanism, which remains an ongoing challenge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Moving photoacoustic sources: Acoustic waveforms in one, two, and three dimensions and application to trace gas detection

The photoacoustic effect is governed by a wave equation with a source term proportional to the time derivative of the optical heat deposition per unit volume and time. Although the typical configuration for generation of the photoacoustic effect makes use of pulsed or amplitude modulated optical beams, the form of the source term in the wave equation indicates that a continuous optical source moving in an absorbing medium is capable of sound generation as well. Here, the properties of simple sources moving in one, two, and three space dimensions are reviewed. The salient feature of sources moving in one-dimension at sound speed is that the amplitude of the acoustic wave increases with time without bound according to linear acoustics. Finally, two schemes, one in the time-domain and the other in the frequency-domain, that take advantage of this principle for increasing the sensitivity of trace gas detection are reviewed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hard disk drive based microsecond x-ray chopper for characterization of ionization chambers and photodiodes

A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few μs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of μs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic study of z-pinch stagnation on Z.

Fast z-pinches provide intense 1-10 keV photon energy radiation sources. Here, we analyze time-, space-, and spectrally-resolved {approx}2 keV K-shell emissions from Al (5% Mg) wire array implosions on Sandia's Z machine pulsed power driver. The stagnating plasma is modeled as three separate radial zones, and collisional-radiative modeling with radiation transport calculations are used to constrain the temperatures and densities in these regions, accounting for K-shell line opacity and Doppler effects. We discuss plasma conditions and dynamics at the onset of stagnation, and compare inferences from the atomic modeling to three-dimensional magneto-hydrodynamic simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mixing models for the two-way-coupling of CFD codes and zero-dimensional multi-zone codes to model HCCI combustion

The objective of this work is the development of a consistent mixing model for the two-way-coupling of a CFD code and a multi-zone code based on multiple zero-dimensional reactors. The two-way-coupling allows for a computationally efficient modeling of HCCI combustion. The physical domain in the CFD code is subdivided into multiple zones based on three phase variables (fuel mixture fraction, dilution, and total enthalpy). Those phase variables are sufficient for the description of the thermodynamic state of each zone, assuming that each zone is at the same pressure. Each zone in the CFD code is represented by a corresponding zone in the zero-dimensional code. The zero-dimensional code solves the chemistry for each zone, and the heat release is fed back into the CFD code. The difficulty in facing this kind of methodology is to keep the thermodynamic state of each zone consistent between the CFD code and the zero-dimensional code after the initialization of the zones in the multi-zone code has taken place. The thermodynamic state of each zone (and thereby the phase variables) will change in time due to mixing and source terms (e.g., vaporization of fuel, wall heat transfer). The focus of this work lies on a consistent description of the mixing between the zones in phase space in the zero-dimensional code, based on the solution of the CFD code. Two mixing models with different degrees of accuracy, complexity, and numerical effort are described. The most elaborate mixing model (and an appropriate treatment of the source terms) keeps the thermodynamic state of the zones in the CFD code and the zero-dimensional code identical. The models are applied to a test case of HCCI combustion in an engine. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Screening the fifth force in the Horndeski's most general scalar-tensor theories

We study how the Vainshtein mechanism operates in the most general scalar-tensor theories with second-order equations of motion. The field equations of motion, which can be also applicable to most of other screening scenarios proposed in literature, are generally derived in a spherically symmetric space-time with a matter source. In the presence of a field coupling to the Ricci scalar, we clarify conditions under which the Vainshtein mechanism is at work in a weak gravitational background. We also obtain the solutions of the field equation inside a spherically symmetric body and show how they can be connected to exterior solutions that accommodate the Vainshtein mechanism. We apply our general results to a number of concrete models such as the covariant/extended Galileons and the DBI Galileons with Gauss-Bonnet and other terms. In these models the fifth force can be suppressed to be compatible with solar-system constraints, provided that non-linear field kinetic terms coupled to the Einstein tensor do not dominate over other non-linear field self-interactions.

79 ASTRONOMY AND ASTROPHYSICS↗

Converting an AEG Cyclotron to H{sup -} Acceleration and Extraction

Clinical Trials are under way to evaluate agents labeled with the nuclide {sup 225}Ac and its decay product {sup 213}Bi, in targeted alpha-immuno-therapy. {sup 225}Ac can be produced on a medium-energy cyclotron via the nuclear reaction {sup 226}Ra(p,n){sup 225}Ac. To demonstrate proof-of-principle, a vintage AEG cyclotron, Model E33, with an internal target, had been employed in a pilot production program at the Technical University of Munich (TUM). To enhance production capability and further support the clinical studies, the TUM facility has recently been refurbished and upgraded, adding a new external beam-line, automated target irradiation and transport systems, new laboratories, hot cells, etc.. An improved high-power rotating target has been built and installed. The AEG cyclotron itself has also been modified and upgraded to accelerate and extract H{sup -} ions. We have designed, built, and tested a new axial Penning-type ion source which is optimized for the production of H{sup -} ions. The ion source has continued to evolve through experiment and experience. Steady improvements in materials and mechanics have led to enhanced source stability, life-time, and H{sup -} production. We have also designed and built a precision H{sup -} charge-exchange beam-extraction system which is equipped with a vacuum lock. To fit within the tight mechanical constraint imposed by the narrow magnet gap, the system incorporates a novel chain-drive foil holder and foil-changer mechanism. The reconfigured cyclotron system has now been in operation for more than 1 year. Three long-duration target irradiations have been conducted. The most recent bombardment ran 160 continuous hours at a beam on target of {approx}80 microamperes for a total yield of {approx}70 milli-curies of {sup 225}Ac.

43 PARTICLE ACCELERATORS↗

ITER Generic Diagnostic Upper Port Plug Nuclear Heating and Personnel Dose Rate Assesment Neutronics Analysis using the ATTILA Discrete Ordinates Code

Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of the ECH heating system were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture (ECH). The neutronics discrete-ordinates code ATTILA® and SEVERIAN® (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken from the ITER “Brand Model” MCNP benchmark model. A biased quadrature set equivelant to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and ECH cases. The ECH or Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 μSv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 μSv/hr but fell below the limit to 90 μSv/hr 2-weeks later. The Large Aperture or ECH style shielding model exhibited higher and more persistent dose rates. After 1-day the dose rate was 230 μSv/hr but was still at 120 μSv/hr 4-weeks later. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e - equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

47 OTHER INSTRUMENTATION↗

Multifunctional bulk plasma source based on discharge with electron injection

A bulk plasma source, based on a high-current dc glow discharge with electron injection, is described. Electron injection and some special design features of the plasma arc emitter provide a plasma source with very long periods between maintenance down-times and a long overall lifetime. The source uses a sectioned sputter-electrode array with six individual sputter targets, each of which can be independently biased. This discharge assembly configuration provides multifunctional operation, including plasma generation from different gases (argon, nitrogen, oxygen, acetylene) and deposition of composite metal nitride and oxide coatings.

36 MATERIALS SCIENCE↗

A new coaxial high power microwave source based on dual beams

We present a new coaxial high power microwave source based on dual beams, which combines a relativistic backward wave oscillator (RBWO) (noted as the inner sub-source below) and a coaxial transit-time oscillator (TTO) (noted as the outer sub-source). The cathode consists of an inner and an outer annular cathode, which provides the inner and the outer annular electron beam for the sub-sources, respectively. Particle-in-cell (PIC) simulation results demonstrate that power conversion efficiencies of the two sub-sources with an identical frequency of 9.74 GHz are 29% and 25%, respectively. It is furthermore found that phase locking between the inner and the outer sub-sources can be realized, which suggests a feasibility to obtain a higher power output if the two microwave signals are coherently combined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo-Based Method for Parallelizing Quasi-Static Time-Series Power System Simulations: Preprint

Both commercial and open source power system simulators run quasi-static time-series (QSTS) simulations sequentially. For yearlong high-resolution load profiles this sequential execution of load flows incurs long computation times. Parallelizing QSTS simulations on multiple processors is one possible way to reduce the computation time. Parallelization however introduces errors in the simulation results as the initial state of the system at the beginning of each parallelized time period is not known. In this work a Monte Carlo-based approach has been proposed to estimate the initial state of the system for each parallel simulation run to mitigate the errors in the final results. Classical sequential QSTS simulation is the chosen base case against which all other methods have been compared. Results presented in this paper show that the proposed method improves the simulation results considerably. This paper also discusses possible sensitivities of the proposed method to a number of tunable parameters. Additionally, sensitivity analysis results for a number of parameters have also been presented in the results section.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Green Synthesized Carbon Quantum Dots from Polianthes tuberose L. Petals for Copper (II) and Iron (II) Detection

In this work carbon quantum dots (CQDs) are synthesized via a simple, low cost and as well as green way using tuberose (Polianthes tuberose L.) petals as the carbon source for the first time. We have not done any surface modification to the prepared CQDs although we directly employed this as fluorescent probe for the sensitive and selective detection of Fe{sup 2+} and Cu{sup 2+} ions. Both these ions drastically quench the emission intensity of the CQDs; in case of Cu{sup 2+} ions quenched CQDs EDTA results in regaining the fluorescence property but for Fe{sup 2+} ions quenched CQDs no such effect of EDTA is found. The limit of detection (LOD) is observed to be 200 nM in case of Cu{sup 2+} which is much lower than the safe limit provided by the WHO in drinking water. Hence the CQDs prepared in this simple and low cost method may find an important role in monitoring the water quality. The quantum yield of the CQDs prepared in our method is around 3%. Transmission electron microscope shows picture of nicely shaped CQDs with average size ~ 4 nm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synergetic Use of the WSR-88D Radars, GOES-R Satellites, and Lightning Networks to Study Microphysical Characteristics of Hurricanes

Abstract This study analyzes the microphysics and precipitation pattern of Hurricanes Harvey (2017) and Florence (2018) in both the eyewall and outer rainband regions. From the retrievals by a satellite red–green–blue scheme, the outer rainbands show a strong convective structure while the inner eyewall has less convective vigor (i.e., weaker upper-level reflectivities and electrification), which may be related to stronger vertical wind shear that hinders fast vertical motions. The WSR-88D column-vertical profiles further confirm that the outer rainband clouds have strong vertical motion and large ice-phase hydrometeor formation aloft, which correlates well with 3D Lightning Mapping Array source counts in height and time. From the results from this study, it is determined that the inner eyewall region is dominated by warm rain, whereas the external rainband region contains intense mixed-phase precipitation. External rainbands are defined here as those that reside outside of the main hurricane circulation, associated with surface tropical storm wind speeds. The synergy of satellite and radar dual-polarization parameters is instrumental in distinguishing between the key microphysical features of intense convective rainbands and the warm-rain-dominated eyewall regions within the hurricanes. Substantial amounts of ice aloft and intense updrafts in the external rainbands are indicative of heavy surface precipitation, which can have important implications for severe weather warnings and quantitative precipitation forecasts. The novel part of this study is to combine ground-based radar measurement with satellite observations to study hurricane microphysical structure from surface to cloud top so as to fill in the gaps between the two observational techniques.

Meteorology & Atmospheric Sciences↗

High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/{Delta}m > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detection by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH{sub 3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-93: Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate

Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall was identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature.

60 APPLIED LIFE SCIENCES↗