Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Evaluation of partial volume correction and analysis of longitudinal [ 18 F]GTP1 tau PET imaging in Alzheimer's disease using linear mixed-effects models

Purpose: We evaluated the impact of partial volume correction (PVC) methods on the quantification of longitudinal [ 18 F]GTP1 tau positron-emission tomography (PET) in Alzheimer's disease and the suitability of describing the tau pathology burden temporal trajectories using linear mixed-effects models (LMEM). Methods: We applied van Cittert iterative deconvolution (VC), 2-compartment, and 3-compartment, and the geometric transfer matrix plus region-based voxelwise methods to data acquired in an Alzheimer's disease natural history study over 18 months at a single imaging site. We determined the optimal PVC method by comparing the standardized uptake value ratio change (%ΔSUVR) between diagnostic and tau burden–level groups and the longitudinal repeatability derived from the LMEM. The performance of LMEM analysis for calculating %ΔSUVR was evaluated in a natural history study and in a multisite clinical trial of semorinemab in prodromal to mild Alzheimer's disease by comparing results to traditional per-visit estimates. Results: The VC, 2-compartment, and 3-compartment PVC methods had similar performance, whereas region-based voxelwise overcorrected regions with a higher tau burden. The lowest within-subject variability and acceptable group separation scores were observed without PVC. The LMEM-derived %ΔSUVR values were similar to the per-visit estimates with lower variability. Conclusion: The results indicate that the tested PVC methods do not offer a clear advantage or improvement over non-PVC images for the quantification of longitudinal [ 18 F]GTP1 PET data. LMEM offers a robust framework for the longitudinal tau PET quantification with low longitudinal test–retest variability. Clinical trial registration: NCT02640092 and NCT03289143.

60 APPLIED LIFE SCIENCES↗

Significant slowdown of plasma-optimized surface energy deactivation by vacuum sealing for efficient adhesive bonding

This work proposes an approach to minimize surface energy deactivation of plasma-treated metal and carbon fiber-reinforced polymer (CFRP) surfaces by vacuum sealing. Plasma treatments enhance adhesive wettability on post-treated surfaces for adhesive joints, but the treated surfaces deactivate quickly in air. The surface energy of aluminum alloy AA6061 and carbon fiber-reinforced polymer-polyamide (CFRP-PA66) optimally treated by a blown air plasma instrument returns to the original surface energy within one hour. Vacuum sealing of AA6061 and CFRP-PA66 reduced the surface energy deactivation over 7 days by at least 230 times and 970 times compared to in air. Double Cantilever Beam (DCB) tests performed on adhesively-bonded AA6061/CFRP-PA66 joints showed that the total energy release and energy dissipation before failure of plasma-treated and vacuum-sealed materials was up to 60% more than plasma-treated materials without vacuum sealing and up to 125% more than non-plasma-treated materials.

42 ENGINEERING↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

Predicting defects in laser powder bed fusion using in-situ thermal imaging data and machine learning

Variation in the local thermal history during the Laser Powder Bed Fusion (LPBF) process in Additive Manufacturing (AM) can cause micropore defects, which add to the uncertainty of the mechanical properties (e.g., fatigue life, tensile strength) of the built materials. In-situ sensing has been proposed for monitoring the AM process to minimize defects, but successful minimization requires establishing a quantitative relationship between the sensing data and the porosity, which is particularly challenging with a large number of variables (e.g., laser speed, power, scan path, powder property). Physics-based modeling can simulate such an in-situ sensing-porosity relationship, but it is computationally costly. In this work, we develop Machine Learning (ML) models that can use in-situ thermographic data to predict the micropore of LPBF stainless steel materials. This work considers two identified key features from the thermal histories: the time above the apparent melting threshold ($\tau$) and the maximum radiance ( T max ). These features are computed, stored for each voxel in the built material, and then used as inputs. The binary state of each voxel, either defective or normal, is the output. Different ML models are trained and tested for the binary classification task. In addition to using the thermal features of each voxel to predict its own state, the thermal features of neighboring voxels are also included as inputs. This is shown to improve the prediction accuracy, which is consistent with thermal transport physics around each voxel contributing to its final state. Among the models trained, the F1 scores on test sets reach above 0.96 for Random Forests. Feature importance analysis based on the ML models shows that T max is more important to the voxel state than $\tau$ . The analysis also finds that the thermal history of the voxels above the present voxel is more influential than those beneath it. Our study significantly extends the capability of using in-situ thermographic data to predict porosity in LPBF materials. Finally, since ML models are fast, they may play integral roles in the optimization and control of such AM technologies.

36 MATERIALS SCIENCE↗

Progress on the reevaluation and validation of the n+233U neutron cross sections

The set of 233 U resonance parameters of the ENDF/B-VIII.0 nuclear data library was adopted from the previous ENDF/B-VII.1 evaluation using the external levels to update the thermal values. Adoption of IAEA 2017 thermal standards ( σ f = 533.0 ± 2.2 b, σ c = 44.9 ± 0.9 b, and ν ‾ tot = 2.487 ± 0.011 ) and of the IAEA-recommended thermal-neutron induced prompt fission neutron spectrum (PFNS) with average PFNS energy of 2.030 ± 0.013 MeV requires a re-evaluation of 233 U neutron cross sections in the resolved resonance region. A newly produced evaluation is being tested on benchmarks carefully selected from the Handbook of International Criticality Safety Benchmark Experiments (ICSBEP) which are highly sensitive to 233 U data. An important goal of this work was to eliminate the strong negative gradient of the calculated effective multiplication factors with respect to the epithermal fission fraction observed in the validation of the ENDF/B-VIII.0 library for those assemblies. A significant improvement in integral performance of critical 233 U solutions is observed for the newly proposed evaluation. Further work addressing the fast neutron region is needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

Intermetallic particle heterogeneity controls shear localization in high-strength nanostructured Al alloys

The mechanical behavior of two nanocrystalline Al alloys, Al-Mg-Y and Al-Fe-Y, is investigated with in-situ micropillar compression testing. Both alloys were strengthened by a hierarchical microstructure including grain boundary segregation, nanometer-thick amorphous complexions, carbide nanorod precipitates with sizes of a few nanometers, and submicron-scale intermetallic particles. The maximum yield strength of the Al-Mg-Y system is measured to be 950 MPa, exceeding that of the Al-Fe-Y system (680 MPa), primarily due to a combination of more carbide nanorods and more amorphous complexions. Both alloys exhibited yield strengths much higher than those of commercial Al alloys, and therefore have great potential for structural applications. However, some micropillar specimens were observed to plastically soften through shear banding. Post-mortem investigation revealed that intermetallic-free deformation pathways of a few micrometers in length were responsible for this failure. Further characterization showed significant grain growth within the shear band. The coarsened grains maintained the same orientation with each other, pointing to grain boundary mechanisms for plastic flow, specifically grain rotation and/or grain boundary migration. Here, the presence of intermetallic particles makes it difficult for both matrix and intermetallic grains to rotate into the same orientation due to the different lattice parameters and slip systems. Therefore, we are able to conclude that a uniform distribution of intermetallic particles with an average spacing less than the percolation length of shear localization can effectively prevent the maturation of shear bands, offering a design strategy for high-strength nanocrystalline Al alloys with both high strength and stable plastic flow.

36 MATERIALS SCIENCE↗

The first Hubble diagram and cosmological constraints using superluminous supernovae

In this work, we present the first Hubble diagram of superluminous supernovae (SLSNe) out to a redshift of two, together with constraints on the matter density, Ω M , and the dark energy equation-of-state parameter, w(≡p/ρ). We build a sample of 20 cosmologically useful SLSNe I based on light curve and spectroscopy quality cuts. We confirm the robustness of the peak–decline SLSN I standardization relation with a larger data set and improved fitting techniques than previous works. We then solve the SLSN model based on the above standardization via minimization of the χ2 computed from a covariance matrix that includes statistical and systematic uncertainties. For a spatially flat Λ cold dark matter (ΛCDM) cosmological model, we find $\Omega _{\rm M}=0.38^{+0.24}_{-0.19}$, with an rms of 0.27 mag for the residuals of the distance moduli. For a w 0 w a CDM cosmological model, the addition of SLSNe I to a ‘baseline’ measurement consisting of Planck temperature together with Type Ia supernovae, results in a small improvement in the constraints of w 0 and wa of 4 per cent. We present simulations of future surveys with 868 and 492 SLSNe I (depending on the configuration used) and show that such a sample can deliver cosmological constraints in a flat ΛCDM model with the same precision (considering only statistical uncertainties) as current surveys that use Type Ia supernovae, while providing a factor of 2–3 improvement in the precision of the constraints on the time variation of dark energy, w 0 and w a . This paper represents the proof of concept for superluminous supernova cosmology, and demonstrates they can provide an independent test of cosmology in the high-redshift (z > 1) universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Esterification of 3-quinuclidinol, a marker for the incapacitant BZ, for analysis by EI-GC-MS in OPCW test matrices

The analysis by EI-GC-MS of 3-quinuclidinol (3Q), a marker for the riot control and incapacitating agent quinuclinidyl benzilate (BZ), using several, new acylation strategies is described. After evaluating and optimizing conditions for the acylations, these were tested on their ability to successfully derivatize 3Q in three different matrices featured in the 44th Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test (PT). As 3Q is a highly polar compound, the work here describes acylation strategies that generate 3Q analogs with superior gas chromatographic profiles relative to the underivatized material. The acyl groups studied in this work included acetyl, benzoyl, pentafluorobenzoyl and the bis(3,5-trifluoromethyl)benzoyl. The acylated 3Q products provide sharp, detectable peaks with significantly different retention times from that of the unmodified 3Q. Thus, the retention times for acetyl-, benzoyl-, pentafluorobenzoyl- and 3,5-bis(trifluoromethyl)benzoyl-3Q were determined to be 15.9, 24.9, 22.8 and 22.1 min respectively, in stark contrast to the unmodified 3Q which provides a sharp peak with a retention time centered at ~ 13.5 min only at high concentrations (> 10 µg/mL or µg/g) while a broad peak (RT ~ 15–15.5 min) at low concentrations (< 5 µg/mL or µg/g). The developed protocol was used to derivatize 3Q in three separate matrices. The first two matrices were liquid samples featured during the 44th OPCW PT at two separate concentrations in each (5 and 50 µg/mL). The last matrix was a soil sample featured in the same 44th OPCW PT wherein the 3Q had been spiked at a 12 µg/g concentration. The approach involves the extraction of 3Q from all matrices followed by its acylation resulting in a second reportable analytical method for an OPCW PT. The presented derivatization strategies should find wide applicability particularly in laboratories involved with the analysis of this chemical weapon agent degradation product and those participating in the yearly OPCW PTs.

3-quinuclidinol↗

Corrosion of 316 L stainless steel under the natural circulation of molten NaCl-MgCl 2 salt

The corrosion behavior of 316 L stainless steel (SS) was studied via the natural circulation of molten eutectic NaCl-MgCl 2 salt through a microloop. The post-corrosion tested 316 L SS microloop sections were characterized with microscopy techniques to determine the microstructural and microchemical changes that occurred at the alloy/salt interface. It was found that 316 L SS showed heterogeneous dissolution at the hot-leg, whereas deposition of corrosion products occurred at the cold-leg. For the first time, experimentally obtained molten salt flow-induced corrosion of 316 L SS results were combined with computational thermodynamic-kinetic models to validate the dissolution and deposition in terms of elemental compositional changes at the alloy/salt interface. The thermodynamic-kinetic modeling predicted that the heterogeneous dissolution of Cr and Fe from the hot-leg section of 316 L SS persisted throughout the salt circulation. The model also estimated that, despite Cr deposition starting earlier than Fe, the total redeposition of Fe is expected to be significantly greater than that of Cr over the circulation of salt. Furthermore, the modeling accurately predicted the subsurface enrichment of Mo which is attributed to the reduced Cr activity and the relatively higher diffusion rate of Mo within the alloy matrix. Here, the agreement between modeling and experimental results confirms that Fe chlorides dissolve at the hot-leg and subsequently deposit at the cold-leg due to activity changes driven by the thermal gradient. By contrast, Cr was not detected in the cold-leg deposits, which is attributed to its weaker temperature dependence on activity, limiting its redeposition under these conditions.

36 - MATERIALS SCIENCE↗

Strain rate effects on the mechanical behavior of porous titanium with different pore sizes

High strain-rate (up to 6600 s –1 ) and quasi-static compression tests are conducted on a powder-sintered porous titanium with different pore sizes (mean: 30 μm and 120 μm). In situ X-ray imaging is implemented to characterize the pores-scale deformation dynamics. The yield strength as a function of strain rate exhibits two stages of rate sensitivity, and the transition occurs at 1600 s –1 . X-ray images show that pore compaction and strain localizations occur preferentially at pores oriented perpendicular to the loading direction under quasi-static loading, but become more random under high strain-rate loading as a result of higher driving force and plastic deformation nucleation rate. Here, the more homogeneous nucleation of plastic deformation contributes to the increased rate sensitivity beyond 1600 s –1 . At the same strain rate, the yield strength of porous Ti as well as strain field homogeneity decreases significantly with increasing pore size. The small pore spacing in fine-pored Ti reduces the degree of stress concentrations around pores. Therefore, the higher stress concentrations in coarse-pored Ti lead to an earlier yield of matrix around pores and thus a lower bulk yield strength.

36 MATERIALS SCIENCE↗

Information theory optimization of signals from small-angle scattering measurements

Small-angle X-ray scattering (SAXS) of particles in solution informs on the conformational states and assemblies of biological macromolecules (bioSAXS) outside of cryo- and solid-state conditions. In bioSAXS, the SAXS measurement under dilute conditions is resolution limited, and through an inverse Fourier transform, the measured SAXS intensities directly relate to the physical space occupied by the particles via the P (r)-distribution. Yet, this inverse transform of SAXS data has been historically cast as an ill-posed, ill-conditioned problem requiring an indirect approach. Here, we show that through the applications of matrix and information theories, the inverse transform of SAXS intensity data is a well-conditioned problem. The so-called ill-conditioning of the inverse problem is directly related to the Shannon number. By exploiting the oversampling enabled by modern detectors, a direct inverse Fourier transform of the SAXS data is possible, provided the recovered information does not exceed the Shannon number. The Shannon limit corresponds to the maximum number of significant singular values that can be recovered in a SAXS experiment, suggesting this relationship is a fundamental property of band-limited inverse integral transform problems. This correspondence reduces the complexity of the inverse problem to the Shannon limit and maximum dimension. We propose a hybrid scoring function using an information theory framework that assesses both the quality of the model-data fit as well as the quality of the recovered P (r)-distribution. The hybrid score utilizes the Akaike information criteria and Durbin-Watson statistic that considers parameter-model complexity, i.e., degrees of freedom, and the randomness of the model-data residuals. The described tests and findings extend the boundaries for bioSAXS by completing the information theory formalism initiated by Peter B. Moore to enable a quantitative measure of resolution in SAXS, robustly determine maximum dimension, and more precisely define the best parameter model appropriately representing the observed scattering data.

Rambo, Robert P. [Science and Technology Facilitie↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Performance of Graphene/Polydimethylsiloxane Surfaces against S. aureus and P. aeruginosa Single- and Dual-Species Biofilms

The increasing incidence of implant-associated infections has prompted the development of effective strategies to prevent biofilm formation on these devices. In this work, pristine graphene nanoplatelet/polydimethylsiloxane (GNP/PDMS) surfaces containing different GNP loadings (1, 2, 3, 4, and 5 wt%) were produced and evaluated on their ability to mitigate biofilm development. After GNP loading optimization, the most promising surface was tested against single- and dual-species biofilms of Staphylococcus aureus and Pseudomonas aeruginosa. The antibiofilm activity of GNP/PDMS surfaces was determined by the quantification of total, viable, culturable, and viable but nonculturable (VBNC) cells, as well as by confocal laser scanning microscopy (CLSM). Results showed that 5 wt% GNP loading reduced the number of total (57%), viable (69%), culturable (55%), and VBNC cells (85%) of S. aureus biofilms compared to PDMS. A decrease of 25% in total cells and about 52% in viable, culturable, and VBNC cells was observed for P. aeruginosa biofilms. Dual-species biofilms demonstrated higher resistance to the antimicrobial activity of GNP surfaces, with lower biofilm cell reductions (of up to 29% when compared to single-species biofilms). Still, the effectiveness of these surfaces in suppressing single- and dual-species biofilm formation was confirmed by CLSM analysis, where a decrease in biofilm biovolume (83% for S. aureus biofilms and 42% for P. aeruginosa and dual-species biofilms) and thickness (on average 72%) was obtained. Overall, these results showed that pristine GNPs dispersed into the PDMS matrix were able to inhibit biofilm growth, being a starting point for the fabrication of novel surface coatings based on functionalized GNP/PDMS composites.

Oliveira, Isabel M.↗

A data-driven approach to sampling matrix selection for compressive sensing

Sampling is a fundamental aspect of any implementation of compressive sensing. Typically, the choice of sampling method is guided by the reconstruction basis. However, this approach can be problematic with respect to certain hardware constraints and is not responsive to domain-specific context. We propose a method for defining an order for a sampling basis that is optimal with respect to capturing variance in data, thus allowing for meaningful sensing at any desired level of compression. We focus on the Walsh-Hadamard sampling basis for its relevance to hardware constraints, but our approach applies to any sampling basis of interest. We illustrate the effectiveness of our method on the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset, the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset, and a Colorado State University Swiss Ranger depth image dataset. The spectral datasets consist of simulant experiments, including releases of chemicals such as GAA and SF6. We combine our sampling and reconstruction with the adaptive coherence estimator (ACE) and bulk coherence for chemical detection and we incorporate an algorithmic threshold for ACE values to determine the presence or absence of a chemical. We compare results across sampling methods in this context. We have successful chemical detection at a compression rate of 90%. For all three datasets, we compare our sampling approach to standard orderings of sampling basis such as random, sequency, and an analog of sequency that we term `frequency.' In one instance, the peak signal to noise ratio was improved by over 30% across a test set of depth images.

compressive sensing, hyperspectral imaging, Walsh-↗

Development of Gamma Background Radiation Digital Twin with Machine Learning Algorithms: Application of Unsupervised Machine Learning to Detection of Anomalies and Nuisances in Gamma Background Radiation Environmental Screening Data

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for development of a digital twin of gamma radiation background, and for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. In one segment of work, we developed a gamma background estimation model using a Longshort term memory (LSTM) network for one-step CPS time series prediction. The LSTM model was validated with two data sets of measurements from two independent NaI detectors positioned on a mobile platform. The data sets contained background radiation only and no orphan isotope sources. The LSTM model was constructed and tested using data from one of the detectors. Performance of the LSTM model was validate through one-step prediction of CPS time series of another NaI detector without re-training. This approach allows to create a digital twin for nuclear background estimation. Using LSTM, it could be possible to detect a source through subtraction of the estimated counts from the measured background. In another segment of work, we investigated detection of gamma emitting sources in the presence of complex background using unsupervised machine learning. Spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

54 ENVIRONMENTAL SCIENCES↗

Modeling MTS pyrolysis and SiC deposition kinetics using principal component analysis and neural networks

Accurate chemical kinetics modeling is crucial for improving the efficiency of chemical processing and synthesis of ceramic matrix composites. Detailed kinetic models are computationally expensive due to the large number of transported chemical species, while the simplified physics-based models, such as single-step global mechanisms, are efficient but often overlook key chemical intermediates and pathways. Recent deep learning approaches promise accurate and cost-effective models. Yet, they require additional closures for the transported nonlinear latent variables, complicating integration with existing solvers. In this work, we develop a hybrid linear—nonlinear reduced model for silicon carbide deposition from methyltrichlorosilane precursor by combining principal component analysis (PCA) and autoencoder (AE) neural network (NN) approaches. PCA is used to identify a smaller set of linear transport variables, enabling direct reuse of conventional transport solvers. NNs then reconstruct the full chemical state from these reduced variables. We demonstrate the method on a chemical vapor deposition reactor—comprising a gas-phase pyrolysis plug flow reactor and a heterogeneous surface reactor—over a wide range of temperatures, pressures, and residence times. Our PCA–AE model achieves high accuracy with only five transported scalars, achieving an eightfold cost reduction compared to detailed mechanisms, in both a priori (using data from the test set only) and a posteriori (coupled with a differential equation solver). In conclusion, notable errors arise primarily near training domain boundaries and for long residence times, indicating the need for domain shift indicators and better long-horizon predictions in future reduced chemistry model development.

autoencoder neural networks↗

Report on partially complete post-irradiation-examination of the INL samples

Ferritic-martensitic steels (NF616 and T91), and austenitic stainless steel 800H and its Grain Boundary Engineering (GBE)-treated version 800H-TMP (ThermoMechanical Processing) were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and their microstructures and mechanical properties were characterized. Ferritic-martensitic steels were irradiated up to 8.16 dpa in the irradiation temperatures ranging from 241 °C to 447.5 °C. Selected 800H and 800H-TMP samples were also irradiated up to 9.12 dpa at 359°C to 431°C. Vickers hardness measurement, fractography, and microstructural characterization were performed on the selected samples in the LAMDA lab. Radiation-induced hardening of NF616 and T91 was observed in the hardness measurements which show ~37% to ~65% increases, depending on irradiation dose and irradiation temperature. Within the irradiation conditions studied in this work, samples with a higher dose had a higher hardness. All the tested alloy 800H and 800H-TMP in this work showed irradiation-hardening by ~96±7% to ~152±10%. Alloy 800HTMP tended to have slightly smaller irradiation-hardening than alloy 800H. The fractography of NF616 samples D2 (2.96 dpa at 291.5°C), D4 (5.91 dpa at 359°C), and D6 (8.16 dpa at 431°C) indicated loss of ductility with negligible necking for the sample D2, yet obvious ductile failure for samples D4 and D6. Fractography of alloy 800H samples N4 (7.27 dpa at 359°C), N5 (3.9 dpa at 451.5°C), and N6 (9.01 dpa at 431°C), and alloy 800H-TMP samples P4 (7.36 dpa at 359°C), P5 (3.95 dpa at 451.5°C), and P6 (9.12 dpa at 431°C) indicated that all samples failed in a ductile mode, with obvious necking. Dimples were observed where large Ti-containing particles were observed for the samples. TEM characterization was performed on alloy 800H (N4, N5, N6) and 800H-TMP (P4, P5 and P6). Accumulation of M23C6 precipitates at grain boundaries was observed in all samples, and the presence of Ti(C,N) precipitates at grain boundaries and in the matrix was observed in alloy 800H-TMP. M23C6 precipitates were found to have the cube-on-cube orientation relationship with the matrix. In addition, nanoscale Si-rich clusters were observed in the matrix of all samples. Atom probe tomography was conducted on the same samples, and their results are being analyzed to be integrated with the TEM results for a confident description of the clustering behavior. Due to the low irradiation temperature (up to 451.5°C), dislocation loops formed in all samples, with the density and the average size of dislocation loops in the order of 1022 – 1023 m-3 and 11.7 – 15.9 nm, respectively. The loop densities in alloy 800H were higher than that in alloy 800H-TMP under the same irradiation conditions. Further systematic data analyses, together with some complementary experiments, will be pursued for these samples to foster peer-reviewed journal article publications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗