Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Proton Testing of AMD v1202b System on Chip

Single-Event Effects (SEE) testing was previously conducted on the AMD v1200 System on Chip (SoC) at Massachusetts General Hospital’s (MGH) Francis H. Burr Proton Therapy Center on May 28, 2022, using 200-MeV protons.

Edward J Wyrwas↗

Characterizing Electrical Arc Behavior in Ion Engines

Test results using an engineering model Advanced NEXT thruster are presented to identify different arc types utilizing ground test hardware. Three distinct arc types were observed: grid-to-grid arcs, high voltage-to-chassis arcs, and a combination of both. The frequency of high voltage-to-chassis arcs ranged from 4-30%, depending on operating conditions and hardware configuration. Higher beam currents were typically associated with more frequent high voltage-to-chassis arcs. During these arcs, the measured chassis current levels ranged from 20-70 A, however a significant portion of the output beam current returned to the beam supply via the neutralizer cathode plasma, which may be a ground test facility effect. The paper also discusses conducted susceptibility tests that can be performed at the spacecraft level to address the transients associated with arcing events.

electric propulsion↗

Effects of composition and testing conditions on oxidation behavior of four cast commercial nickel-base superalloys

Four cast nickel-base superalloys were oxidized at 1000 and 1100 C for times up to 100 hr in static air and a Mach 1 gas stream. The oxidation resistance was judged by weight change, metal thickness loss, depletion-zone formation, and oxide formation and morphology. The alloys which formed mostly nickel aluminate (NiAl2O4) and aluminum oxide (Al2O3) (B-1900, VIA, and to a lesser extent 713C) were more oxidation resistant. Poorer oxidation resistance was associated with the appearance of chromium sesquioxide (Cr2O3) and chromite spinel (738X). Refractory metal content had little effect on oxidation resistance. Refractory metals appeared in the scale as tapiolite (NiM2O6, where M represents the refractory metal). Thermal cycling in static air appeared to supply sufficient data for the evaluation of oxidation resistance, especially for alloys which form oxides of low volatility. For alloys of higher chromium levels with high propensities toward forming a chromium-bearing scale of higher volatility, testing under conditions of high gas velocity is necessary to assess fully the behavior of the alloy.

Lowell, C. E.↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

K. J. Pederson↗

Methodology for the Assessment of 3D Conduction Effects in an Aerothermal Wind Tunnel Test

This slide presentation reviews a method for the assessment of three-dimensional conduction effects during test in a Aerothermal Wind Tunnel. The test objectives were to duplicate and extend tests that were performed during the 1960's on thermal conduction on proturberance on a flat plate. Slides review the 1D versus 3D conduction data reduction error, the analysis process, CFD-based analysis, loose coupling method that simulates a wind tunnel test run, verification of the CFD solution, Grid convergence, Mach number trend, size trends, and a Sumary of the CFD conduction analysis. Other slides show comparisons to pretest CFD at Mach 1.5 and 2.16 and the geometries of the models and grids.

Oliver, Anthony Brandon↗

Qualification model spacecraft tests for DEMP, SGEMP, and ESD effects

The development of a satellite design demonstration test program is described. The test approach is comprehensive in that it includes the effects from electrostatic discharge (ESD), system generated electromagnetic pulse (SGEMP), as well as dispersed electromagnetic pulses (DEMP). The comprehensive test concept is based on the similarity of the satellite's response to several environments.

Chivington, E. P.↗

Modeling the use of mobile modular gas samplers in near-field detection

The Wireless Independent Noble Gas Sampler (WINGS) is a mobile, modular gas sampling system designed for use in low infrastructure environments. In the case of a suspected underground nuclear explosion (UNE), WINGS units could be deployed to detect noble gases emanating from the suspected explosion site or identify gases originating from another source entering the local area from offsite. In conclusion, this work uses the atmospheric transport modeling tool inline WRF-HYSPLIT to test the effectiveness of WINGS units around a suspected UNE site as a function of sampler density and distance from the emission point of gases from a UNE.

Air sampling↗

Application of fungistatics in soil reduces N uptake by an arctic ericoid shrub (Vaccinium vitis-idaea)

In arctic tundra soil N is highly limiting, N mineralization is slow and organic N greatly exceeds inorganic N. We studied the effects of fungistatics (azoxystrobin [Quadris{reg_sign}] or propiconazole [Tilt{reg_sign}]) on the fungi isolated from ericaceous plant roots in vitro. In addition to testing the phytotoxicity of the two fungistatics we also tested their effects on growth and nitrogen uptake of an ericaceous plant (Vaccinium uliginosum) in a closed Petri plate system without root-associated fungi. Finally, to evaluate the fungistatic effects in an in vivo experiment we applied fungistatics and nitrogen isotopes to intact tundra soil cores from Toolik Lake, Alaska, and examined the ammonium-N and glycine-N use by Vaccinium vitis-idaea with and without fungistatics. The experiments on fungal pure cultures showed that Tilt{reg_sign} was more effective in reducing fungal colony growth in vitro than Quadris{reg_sign}, which was highly variable among the fungal strains. Laboratory experiments aiming to test the fungistatic effects on plant performance in vitro showed that neither Quadris{reg_sign} nor Tilt{reg_sign} affected V. uliginosum growth or N uptake. In this experiment V. uliginosum assimilated more than an order of magnitude more ammonium-N than glycine-N. The intact tundra core experiment provided contrasting results. After 10 wk of fungistatic application in the growth chamber V. vitis-idaea leaf %N was 10% lower and the amount of leaf {sup 15}N acquired was reduced from labeled ammonium (33%) and glycine (40%) during the 4 d isotope treatment. In contrast to the in vitro experiment leaf {sup 15}N assimilation from glycine was three times higher than from {sup 15}NH{sub 4} in the treatments that received no-fungistatics. We conclude that the function of the fungal communities is essential to the acquisition of N from organic sources and speculate that N acquisition from inorganic sources is mainly inhibited by competition with complex soil microbial communities.

54 ENVIRONMENTAL SCIENCES↗

Exhaust Nozzle Plume Effects on Sonic Boom Test Results for Vectored Nozzles

Reducing or eliminating the operational restrictions of supersonic aircraft over populated areas has led to extensive research at NASA. Restrictions were due to the disturbance of the sonic boom, caused by the coalescence of shock waves formed off the aircraft. Recent work has been performed to reduce the magnitude of the sonic boom N-wave generated by airplane components with a focus on shock waves caused by the exhaust nozzle plume. Previous Computational Fluid Dynamics (CFD) analysis showed how the shock wave formed at the nozzle lip interacts with the nozzle boat-tail expansion wave. An experiment was conducted in the 1- by 1-foot Supersonic Wind Tunnel (SWT) at the NASA Glenn Research Center. Results show how the shock generated at the nozzle lip affects the near field pressure signature, and thereby the potential sonic boom contribution for a nozzle at vector angles from 3 to 8 . The experiment was based on the NASA F-15 nozzle used in the Lift and Nozzle Change Effects on Tail Shock experiment, which possessed a large external boat-tail angle. In this case, the large boat-tail angle caused a dramatic expansion, which dominated the near field pressure signature. The impact of nozzle vector angle and nozzle pressure ratio are summarized.

Castner, Raymond↗

High-lying, non-yrast shell structure in {sup 52}Ti

Gamma rays from {sup 52}Ti have been studied with Gammasphere and the Fragment Mass Analyzer using reactions induced by a {sup 48}Ca beam on a {sup 9}Be target. The data have been used in combination with information from deep-inelastic reactions of {sup 48}Ca beams on a thick {sup 238}U target at an energy about 25% above the Coulomb barrier. The {sup 52}Ti level scheme was expanded considerably, and the lifetimes of some of the identified states were determined for the first time. The excitation of two protons and two neutrons outside the {sup 48}Ca core provide new tests of effective interactions in the full pf-shell model space. The positive-parity states in {sup 52}Ti were compared to theoretical predictions obtained with the GXPF1A, FPD6, and KB3G effective interactions. The comparisons favor, to a degree, the results computed with the GXPF1A interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Are current effectiveness criteria fit for purpose? Using a controversial strategic assessment as a test case

Highlights: • The effectiveness framework of Bond et al. (2015) is tested on a case study. • The strategic assessment of the proposed Browse LNG Precinct is evaluated. • The effectiveness framework is modified as a result of the analysis. • “Legitimacy” encompasses both pluralism and normative effectiveness. • Substantive effectiveness should include consideration of unintended consequences. - Abstract: The aim of this paper is to test the broader utility of the sustainability assessment effectiveness framework of Bond et al. (2015) by applying it to a controversial strategic assessment case study. The effectiveness framework comprises six dimensions: procedural effectiveness, substantive effectiveness, transactive effectiveness, normative effectiveness, pluralism, and knowledge and learning. It was originally developed to evaluate sustainability assessment at a system-wide level and it has not been previously applied to a specific case study. The analysis was conducted through document review and the first-hand experience of two of the authors who were involved in the case study in different capacities. The case study selected was the strategic assessment of the proposed Browse Liquefied Natural Gas (LNG) Precinct in Western Australia, which was conducted over the period 2007–2015 under the strategic assessment provisions of both the Western Australian and Australian Commonwealth environmental legislation. The framework provided a useful structure within which this complex case study could be explored, its strengths and weaknesses brought to light, and the interactions between the dimensions highlighted. We also found opportunities for refinement of the framework. As a result of this analysis we propose to replace the final three dimensions of the framework with legitimacy, where a legitimate process is one which all stakeholders agree is fair and which delivers an acceptable outcome for all parties, though we acknowledge the need for further conceptualisation of this dimension. We also suggest that the concept of substantive effectiveness should be expanded to incorporate the unintended consequences of impact assessment. Our research thus makes both a useful addition to the literature already published on the Browse case study, as well as to the literature on impact assessment effectiveness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Probing the Effectiveness in Stabilizing Lithium Metal Anodes through Functional Additives

A variety of electrolyte additives were comprehensively evaluated to understand their relative capability in stabilizing lithium metal anode. Although the Li||Cu test is an effective test to rule out ineffective additives, a reliable assessment of individual additives cannot be obtained just by a single evaluation method. Therefore, various methods must be combined to truly assess the stabilization of a lithium anode. Moreover, it was also discovered that a significant depletion of electrolytes occurred during the end-of-life of the lithium batteries, which partially contributed to the sudden failure of the lithium batteries during cycling. However, the main culprit of the sudden failure was identified as the significant increase in the resistance of the lithium metal anode. Further, when used as an additive, cyclic fluorinated carbonates are the most effective in stabilizing the lithium anode and improving the cycling performance of lithium batteries among all the common additives. Despite its cost-effectiveness, the additive in the conventional electrolyte approach provides insufficient protection for lithium metal due to the complete consumption of the additive materials, which is necessary to repair the solid-electrolyte interphase (SEI). Therefore, it is suggested that a larger ratio (>15 wt %) of the SEI former should be employed to achieve effective lithium stabilization.

25 ENERGY STORAGE↗

Data for Impact of Vertical and Seasonal Variation in Leaf Traits on Simulating Soybean Canopy Photosynthesis via 1D and 3D Modeling

Accurate modeling of photosynthesis is crucial for predicting crop productivity and quantifying the carbon cycle in agroecosystems. Leaf traits are essential inputs for modeling canopy photosynthesis. Yet, many existing models still use fixed plant functional type (PTF)-based values to parameterize leaf traits under a big-leaf or two-big-leaf assumption, neglecting their vertical profiles and seasonal changes. This simplification may introduce significant uncertainties in estimating gross primary productivity (GPP). In this study, we simulated soybean GPP and tested the effects of vertical and seasonal variation in three key leaf photosynthetic traits: the maximum carboxylation rate at 25 °C (Vcmax25), leaf chlorophyll content (LCC), and leaf mass per area (LMA) in the 1D-SCOPE and 3D-Helios models. Weekly field measurements were conducted during the growing season of 2024 to support the simulation. We designed ten leaf trait parameterization schemes by incorporating different combinations of vertical profiles and seasonal changes, while assuming homogeneous canopy architecture in both models. Our results revealed that Vcmax25 vertical and seasonal variation had the strongest influence on simulated GPP in both 1D and 3D models, while LCC and LMA effects were minimal. Particularly, the scheme with an empirically parameterized Vcmax25 profile achieved comparable performance to the scheme with the measured Vcmax25 profile. Both 1D-SCOPE and 3D-Helios accurately modeled GPP (SCOPE: R2 = 0.87, Bias = 0.55 µmol m⁻² s⁻¹; Helios: R2 = 0.9, Bias = 0.22 µmol m⁻² s⁻¹) under the most complex scheme, and their responses to vertical and seasonal variation in leaf traits were consistent, demonstrating the robustness of our findings. Based on our findings, we propose a scalable framework for parameterizing leaf traits to improve GPP simulations. This study contributes to improving the representation of leaf trait dynamics in canopy-level photosynthesis models, potentially enhancing our ability to predict crop productivity and understand agroecosystem carbon dynamics.

Photosynthesis↗

Similarity constraints in testing of cooled engine parts

A study is made of the effect of testing cooled parts of current and advanced gas turbine engines at the reduced temperature and pressure conditions which maintain similarity with the engine environment. Some of the problems facing the experimentalist in evaluating heat transfer and aerodynamic performance when hardware is tested at conditions other than the actual engine environment are considered. Low temperature and pressure test environments can simulate the performance of actual size prototype engine hardware within the tolerance of experimental accuracy if appropriate similarity conditions are satisfied. Failure to adhere to these similarity constraints because of test facility limitations or other reasons, can result in a number of serious errors in projecting the performance of test hardware to engine conditions.

Colladay, R. S.↗

Virtex-II Pro SEE Test Methods and Results

The objective of this coarse Single Event Effect (SEE) test is to determine the suitability of the commercial Virtex-II Pro family for use in spaceflight applications. To this end, this test is primarily intended to determine any Singe Event Latchup (SEL) susceptibilities for these devices. Secondly, this test is intended to measure the level of Single Event Upset (SEU) susceptibilities and in a general sense where they occur. The coarse SEE test was performed on a commercial XC2VP7 device, a relatively small single processor version of the Virtex-II Pro. As the XC2VP7 shares the same functional block design and fabrication process with the larger Virtex-II Pro devices, the results of this test should also be applicable to the larger devices. The XC2VP7 device was tested on a commercial Virtex-II Pro development board. The testing was performed at the Cyclotron laboratories at Texas A&M and Michigan State Universities using ions of varying energy levels and fluences.

Petrick, David↗