Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

BEYONDPLANCK IV. On end-to-end simulations in CMB analysis — Bayesian versus frequentist statistics

End-to-end simulations play a key role in the analysis of any high-sensitivity cosmic microwave background (CMB) experiment, providing high-fidelity systematic error propagation capabilities that are unmatched by any other means. In this paper, we address an important issue regarding such simulations, namely, how to define the inputs in terms of sky model and instrument parameters. These may either be taken as a constrained realization derived from the data or as a random realization independent from the data. We refer to these as posterior and prior simulations, respectively. We show that the two options lead to significantly different correlation structures, as prior simulations (contrary to posterior simulations) effectively include cosmic variance, but they exclude realization-specific correlations from non-linear degeneracies. Consequently, they quantify fundamentally different types of uncertainties. We argue that as a result, they also have different and complementary scientific uses, even if this dichotomy is not absolute. In particular, posterior simulations are in general more convenient for parameter estimation studies, while prior simulations are generally more convenient for model testing. Before BEYONDPLANCK, most pipelines used a mix of constrained and random inputs and applied the same hybrid simulations for all applications, even though the statistical justification for this is not always evident. BEYONDPLANCK represents the first end-to-end CMB simulation framework that is able to generate both types of simulations and these new capabilities have brought this topic to the forefront. The BEYONDPLANCK posterior simulations and their uses are described extensively in a suite of companion papers. In this work, we consider one important applications of the corresponding prior simulations, namely, code validation. Specifically, we generated a set of one-year LFI 30 GHz prior simulations with known inputs and we used these to validate the core low-level BEYONDPLANCK algorithms dealing with gain estimation, correlated noise estimation, and mapmaking.

79 ASTRONOMY AND ASTROPHYSICS↗

Early Results from the Q{sub weak} Experiment

A subset of results from the recently completed Jefferson Lab Q{sub weak} experiment are reported. This experiment, sensitive to physics beyond the Standard Model, exploits the small parity-violating asymmetry in elastic {vector e}p scattering to provide the first determination of the protons weak charge Q{sub w}{sup p}. The experiment employed a 180 {micro}A longitudinally polarized 1.16 GeV electron beam on a 35 cm long liquid hydrogen target. Scattered electrons corresponding to Q{sup 2} of 0.025 GeV{sup 2} were detected in eight Cerenkov detectors arrayed symmetrically around the beam axis. The goals of the experiment were to provide a measure of Q{sub w}{sup p} to 4.2 percent (combined statistical and systematic error), which implies a measure of sin2(thetaw) at the level of 0.3 percent, and to help constrain the vector weak quark charges C{sub 1u} and C{sub 1d}. The experimental method is described, with particular focus on the challenges associated with the worlds highest power LH{sub 2} target. The new constraints on C{sub 1u} and C{sub 1d} provided by the subset of the experiments data analyzed to date will also be shown, together with the extracted weak charge of the neutron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nearest-neighbor oxygen distances in liquid water and ice observed by x-ray Raman based extended x-ray absorption fine structure

We report the nearest-neighbor oxygen-oxygen radial distribution function (NN O-O RDF) of room temperature liquid water and polycrystalline ice Ih (-16.8 deg. C) obtained by x-ray Raman based extended x-ray absorption fine structure (EXAFS) spectroscopy. The spectra of the two systems were taken under identical experimental conditions using the same procedures to obtain the NN O-O RDFs. This protocol ensured a measurement of the relative distance distribution with very small systematic errors. The NN O-O RDF of water is found to be more asymmetric (tail extending to longer distances) with longer average distance (2.81 A ring for water and 2.76 A ring for ice) but a slightly shorter peak position (2.70 A ring for water and 2.71 A ring for ice). The refinement also showed a small but significant contribution from the linear O-H-O multiple scattering signal. The high sensitivity to short range distances of the EXAFS probe will set further restrictions to the range of possible models of liquid water.

36 MATERIALS SCIENCE↗

MINER{nu}A, a Neutrino--Nucleus Interaction Experiment

With the fantastic results of KamLAND and SNO for neutrino physics, a new generation of neutrino experiments are being designed and build, specially to study the neutrino oscillations to resolve most of the incognita still we have in the neutrino physics. At FERMILAB we have the experiments MINOS and, in a near future, NO{nu}A, to study this kind of oscillations. One big problem these experiments will have is the lack of a good knowledge of the Physics of neutrino interactions with matter, and this will generate big systematic errors. MINER{nu}A, also at FERMILAB, will cover this space studying with high statistics and great precision the neutrino--nucleus interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutral pion cross section measurement at K2K

In this paper we report the measurement of the rate of the single {pi}{sup o} production in the K2K close detector. Neutral current single {pi}{sup o} production is measured in Oxygen, in the 1 KT detector. The cross section ratio relative to the total charged current cross section is found to be: 0.063{+-}0.001(stat.){+-}0.006(syst.) in good agreement with the Monte Carlo expectation. Inclusive charged current {pi}{sup o} production is measured in C{sub 8}H{sub 8}, in the SciBar detector, the cross section ratio for these processes relative to the charged current quasi elastic neutrino cross section is found to be 0.306{+-}0.023(stat.){+-}0.025(syst.) showing an excess of (39{+-}15)% (statistical and systematic error added in quadrature) with respect to the prediction of our reference Monte Carlo.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from the HARP Experiment

Hadron production is a key ingredient in many aspects of {nu} physics. Precise prediction of atmospheric {nu} fluxes, characterization of accelerator {nu} beams, quantification of {pi} production and capture for {nu}-factory designs, all of these would profit from hadron production measurements. HARP at the CERN PS was the first hadron production experiment designed on purpose to match all these requirements. It combines a large, full phase space acceptance with low systematic errors and high statistics. HARP was operated in the range from 3 GeV to 15 GeV. We briefly describe here the most recent results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadroproduction measurements: The NA61-SHINE experiment at CERN

The NA61-SHINE experiment at CERN will accurately measure the hadroproduction from interactions of 30-50 GeV proton beams on a carbon target. The precise knowledge of the inclusive spectra of pions and kaons off the target will allow the absolute determination of the neutrino flux of the T2K long baseline experiment at J-PARC, Japan. This paper describes at first the T2K goals concerning the understanding of its neutrino beam and how the NA61 setup will help in providing data for accurate predictions. The second part focuses on the impact of the NA61 measurements on the various systematic errors on the T2K neutrino flux.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A generalized, periodic nonlinearity-reduced interferometer for straightness measurements

Periodic nonlinearity is a systematic error limiting the accuracy of displacement measurements at the nanometer level. However, an interferometer with a displacement measurement accuracy of less than 1 nm is required in nanometrology and in fundamental scientific research. To meet this requirement, a generalized, periodic nonlinearity-reduced interferometer, based on three construction principles has been developed for straightness measurements. These three construction principles have resulted in an interferometer with a highly stable design with reduced periodic nonlinearity. Verifications by a straightness interferometer have demonstrated that the periodic nonlinearity was less than 40 pm. The results also demonstrate that the interferometer design is capable of subnanometer accuracy and is useful in nanometrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of rain age via {gamma} rays from accreted radon progeny

The relative {gamma} ray activities from {sup 214}Pb and {sup 214}Bi condensed from precipitation are used to determine its 'age', the average time the accreted activity has been removed from secular equilibrium. A verifiable assumption that radon progeny on/in the surface/volume of droplets mostly remains in secular equilibrium until they begin their descent, enables estimates of their transit times to ground of typically a few tens of minutes. This agrees well with the time expected for the activity on the surface of droplets to reach the ground from heights of a few kilometers. The half lives of {gamma} activities from {sup 214}Bi and {sup 214}Pb, 19.7 and 26.9 min, respectively, are on the same scale as transit time to ground and close enough to each other to measure ratios of activities from secular equilibrium (1.00) to transient equilibrium (3.88) within a few hundreds of minutes. The ratio of {gamma} count rates is independent of knowledge of either initial activity or any systematic errors and thus limited only by the uncertainty from counting statistics, which from condensates of 5-30 l of rain viewed with 2{pi} solid angle by a 50% efficient, high-resolution Ge detector is only a few percent. These ratios fit extremely well to known theoretical curves, which cannot only be used to date rain but can also be extrapolated backward to determine radon progeny activities in rain prior to its descent, knowledge of which may facilitate further studies using radon progeny as tracers.

54 ENVIRONMENTAL SCIENCES↗

A broadband absorption spectrometer using light emitting diodes for ultrasensitive, in situ trace gas detection

A broadband absorption spectrometer has been developed for highly sensitive and target-selective in situ trace gas measurements. The instrument employs two distinct modes of operation: (i) broadband cavity enhanced absorption spectroscopy (BBCEAS) is used to quantify the concentration of gases in sample mixtures from their characteristic absorption features, and (ii) periodic measurements of the cavity mirrors' reflectivity are made using step-scan phase shift cavity ringdown spectroscopy (PSCRDS). The latter PSCRDS method provides a stand-alone alternative to the more usual method of determining mirror reflectivities by measuring BBCEAS absorption spectra for calibration samples of known composition. Moreover, the instrument's two modes of operation use light from the same light emitting diode transmitted through the cavity in the same optical alignment, hence minimizing the potential for systematic errors between mirror reflectivity determinations and concentration measurements. The ability of the instrument to quantify absorber concentrations is tested in instrument intercomparison exercises for NO{sub 2} (versus a laser broadband cavity ringdown spectrometer) and for H{sub 2}O (versus a commercial hygrometer). A method is also proposed for calculating effective absorption cross sections for fitting the differential structure in BBCEAS spectra due to strong, narrow absorption lines that are under-resolved and hence exhibit non-Beer-Lambert law behavior at the resolution of the BBCEAS measurements. This approach is tested on BBCEAS spectra of water vapor's 4v+{delta} absorption bands around 650 nm. The most immediate analytical application of the present instrument is in quantifying the concentration of reactive trace gases in the ambient atmosphere. The instrument's detection limits for NO{sub 3} as a function of integration time are considered in detail using an Allan variance analysis. Experiments under laboratory conditions produce a 1{sigma} detection limit of 0.25 pptv for a 10 s acquisition time, which improves with further signal averaging to 0.09 pptv in 400 s. Finally, an example of the instrument's performance under field work conditions is presented, in this case of measurements of the sum of NO{sub 3}+N{sub 2}O{sub 5} concentrations in the marine boundary layer acquired during the Reactive Halogens in the Marine Boundary Layer field campaign.

36 MATERIALS SCIENCE↗

A high pressure cell for simultaneous osmotic pressure and x-ray diffraction measurements

In this paper, we report on a novel osmotic cell, developed to simultaneously subject a sample to osmotic stress and measure structural changes by small angle x-ray diffraction. The osmotic cell offers many advantages over more conventional methods of osmotically stressing soft materials to measure their structural response. In particular, a full osmotic analysis can be performed with a single small sample (25 {mu}l). This reduces sample handling and the associated systematic errors, as well as enabling tight control and monitoring of the thermodynamic environment during osmosis, thereby increasing measurement precision. The cell design enables control of osmotic pressure to {+-}0.04 bar over a pressure range of 1-100 bar, and temperature control to {+-}0.05 deg. C. Under these conditions, the lattice spacing in lyotropic structures was resolved to better than {+-}0.005 A. Using the osmotic cell, we demonstrate good agreement with previous conventional measurements on the energy of dehydrating the fluid lamellar phase of dioleoylphosphatidylcholine in water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of Tissue Inhomogeneities on the Accuracy of Proton Path Reconstruction for Proton Computed Tomography

Maintaining a high degree of spatial resolution in proton computed tomography (pCT) is a challenge due to the statistical nature of the proton path through the object. Recent work has focused on the formulation of the most likely path (MLP) of protons through a homogeneous water object and the accuracy of this approach has been tested experimentally with a homogeneous PMMA phantom. Inhomogeneities inside the phantom, consisting of, for example, air and bone will lead to unavoidable inaccuracies of this approach. The purpose of this ongoing work is to characterize systematic errors that are introduced by regions of bone and air density and how this affects the accuracy of proton CT in surrounding voxels both in terms of spatial and density reconstruction accuracy. Phantoms containing tissue-equivalent inhomogeneities have been designed and proton transport through them has been simulated with the GEANT 4.9.0 Monte Carlo tool kit. Various iterative reconstruction techniques, including the classical fully sequential algebraic reconstruction technique (ART) and block-iterative techniques, are currently being tested, and we will select the most accurate method for this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis and calibration of absorptive images of Bose-Einstein condensate at nonzero temperatures

We describe the method allowing quantitative interpretation of absorptive images of mixtures of Bose-Einstein condensate and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction and eliminates arbitrariness of most of the previous approaches. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deconvolution-based correction of alkali beam emission spectroscopy density profile measurements

A deconvolution-based correction method of the beam emission spectroscopy (BES) density profile measurement is demonstrated by its application to simulated measurements of the COMPASS and TEXTOR tokamaks. If the line of sight is far from tangential to the flux surfaces, and the beam width is comparable to the scale length on which the light profile varies, the observation may cause an undesired smoothing of the light profile, resulting in a non-negligible underestimation of the calculated density profile. This effect can be reduced significantly by the emission reconstruction method, which gives an estimate of the emissivity along the beam axis from the measured light profile, taking the finite beam width and the properties of the measurement into account in terms of the transfer function of the observation. Characteristics and magnitude of the mentioned systematic error and its reduction by the introduced method are studied by means of the comprehensive alkali BES simulation code RENATE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Q{sub weak}{sup p} Experiment A Test for Physics Beyond the Standard Model via a Precision Measurement of the Proton Weak Charge

The Qweak collaboration is currently preparing a measurement of the proton's weak charge Q{sub w}{sup p} = (1-4 sin{sup 2} {theta}{sub w}) at the Thomas Jefferson National Accelerator Facility (TJNAF). The experiment has been designed to produce a 4.1% measurement of the weak charge, via a 2.5% measurement of the parity violating asymmetry in the number of elastically scattered 1 GeV electrons from protons, at forward angles. At the proposed precision, the experiment would produce a 0.3% measurement of the weak mixing angle at a momentum transfer of {approx_equal}0.16 GeV, making it the most precise stand alone measurement of the weak mixing angle at low momentum transfer. In combination with other parity measurements, Qweak will also provide a high precision determination of the weak charges of the up and down quarks. Our proposed measurement of Q{sub w}{sup 2} will be performed with significantly smaller statistical and systematic errors than existing low Q{sup 2} data. Any significant deviation from the Standard Model prediction at low momentum transfer (Q{sup 2}) would be a signal of new physics, whereas agreement would place new and significant constraints on possible Standard Model extensions. The experiment is currently being prepared for installation, beginning in late 2009, and data taking beginning in mid 2010.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards High Precision Deuteron Polarimetry

A finite electric dipole moment (EDM) in any fundamental system would constitute a signal for new physics. The deuteron presents itself as an optimal candidate both experimentally and theoretically. A new storage ring technique is being developed for which a small change in the vertical polarization would be a signal of a non-zero EDM. A novel polarimeter concept is under investigation. Besides being highly efficient, this polarimeter should continuously monitor the beam polarization, guaranteeing optimal sensitivity. Detailed studies on systematic error control, in addition to the measurement of cross sections and analyzing powers, were carried out at KVI-Groningen in The Netherlands. Measurements were conducted at COSY-Juelich in Germany yielding high efficiencies. The (statistics limited) ability to track changes in polarization at the level of a few hundred parts-per-million has been demonstrated. Further studies and developments to meet the final goal of sub-part-per-million sensitivity are in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗