Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

SU-E-J-87: Ventilation Weighting Effect On Mean Doses of Both Side Lungs for Patients with Advanced Stage Lung Cancer

Purpose: To study ventilation weighting effect on radiation doses to both side lungs for patients with advanced stage lung cancer. Methods: Fourteen patients with advanced stage lung cancer were included in this retrospective study. Proprietary software was developed to calculate the lung ventilation map based on 4DCT images acquired for radiation therapy. Two phases of inhale (0%) and exhale (50%) were used for the lung ventilation calculations. For each patient, the CT images were resampled to the same dose calculation resolution of 3mmx3mmx3mm. The ventilation distribution was then normalized by the mean value of the ventilation. The ventilation weighted dose was calculated by applying linearly weighted ventilation to the dose of each pixel. The lung contours were automatically delineated from patient CT image with lung window, excluding the tumor and high density tissues. For contralateral and ipsilateral lungs, the mean lung doses from the original plan and ventilation weighted mean lung doses were compared using two tail t-Test. Results: The average of mean dose was 6.1 ±3.8Gy for the contralateral lungs, and 26.2 ± 14.0Gy for the ipsilateral lungs. The average of ventilation weighted dose was 6.3± 3.8Gy for the contralateral lungs and 24.6 ± 13.1Gy for the ipsilateral lungs. The statistics analysis shows the significance of the mean dose increase (p<0.015) for the contralateral lungs and decrease (p<0.005) for the ipsilateral lungs. Conclusion: Ventilation weighted doses were greater than the un-weighted doses for contralateral lungs and smaller for ipsilateral lungs. This Result may be helpful to understand the radiation dosimetric effect on the lung function and provide planning guidance for patients with advance stage lung cancer.

60 APPLIED LIFE SCIENCES↗

SU-E-J-269: Tracking of Tumor Regression for Stage III Lung Cancer Using CBCT

Purpose: This study is to evaluate the tumor regression over the course of EBRT treatment and to determine the difference of tumor reduction for stage III lung squamous cell cancer (SCC) and adenocarcinoma using CBCT. Methods: Twenty three stage III lung cancer patients treated in our clinic who had daily cone beam CT (CBCT) were selected for this study (16 adenocarcinoma and 7 SCC cases). Patients received prescription dose in the range of 50Gy–71.4Gy (mean =60.3Gy, median =50Gy) at 1.8Gy or 2Gy per fraction. Treatments spanned over a minimum of five weeks. Initial mean volume of the gross tumor volume (GTV) was 123cc (range = 14.7cc–353.3cc). For this study, we choose six sets of CBCTs at an interval of one week, starting from the first fraction of treatment. Daily CBCTs from treatment linac computer were transferred to MIM Software version 6.0. An experienced physician contoured the primary GTV on each slices of the CBCT for these patients. Results: A consistent regression of the GTVs was observed in all patients, except in one patient (adeno case) where GTV did not change. Weekly volumetric reduction was in the range of 11.2%–16.6%. Maximum reductions were noticed in the first two weeks of the treatment cycle; mean overall (for adeno+SCC) reductions were 16.6%, 14.2% in week-1 and week-2, respectively. Mean reduction over five weeks of treatment was 49.8% (range = 0.1%–75.5%). Higher reduction was observed in SCC patients as compare to adenocarcinoma cases (54.9% vs. 47.6%); however, the difference was not statistically significant (p-value > 0.05). Conclusion: Large regression of tumors over the course of EBRT for stage III lung cancer patients was observed. Both SCC and adenocarcinoma responded well; overall reduction for SCC cases was higher. A future study is warranted for determining the co-relation between tumor volume reduction and treatment outcome.

60 APPLIED LIFE SCIENCES↗

SU-E-T-591: Optimizing the Flattening Filter Free Beam Selection in RapidArc-Based Stereotactic Body Radiotherapy for Stage I Lung Cancer

Purpose: To optimize the flattening filter free (FFF) beam energy selection in stereotactic body radiotherapy (SBRT) treatment for stage I lung cancer with different fraction schemes. Methods: Twelve patients suffering from stage I lung cancer were enrolled in this study. Plans were designed using 6XFFF and 10XFFF beams with the most widely used fraction schemes of 4*12 Gy, 3*18 Gy and 1*34 Gy, respectively. The plan quality was appraised in terms of planning target volume (PTV) coverage, conformity of the prescribed dose (CI100%), intermediate dose spillage (R50% and D2cm), organs at risk (OARs) sparing and beam-on time. Results: The 10XFFF beam predicted 1% higher maximum, mean dose to the PTV and 4–5% higher R50% compared with the 6XFFF beam in the three fraction schemes, whereas the CI100% and D2cm was similar. Most importantly, the 6XFFF beam exhibited 3–10% lower dose to all the OARs. However, the 10XFFF beam reduced the beam-on time by 31.9±7.2%, 38.7±2.8% and 43.6±4.0% compared with the 6XFFF beam in the 4*12 Gy, 3*18 Gy and 1*34 Gy schemes, respectively. Beam-on time was 2.2±0.2 vs 1.5±0.1, 3.3±0.9 vs 2.0±0.5 and 6.3±0.9 vs 3.5±0.4 minutes for the 6XFFF and 10XFFF one in the three fraction schemes. Conclusion: The 6XFFF beam obtains better OARs sparing in SBRT treatment for stage I lung cancer, but the 10XFFF one provides improved treatment efficiency. To balance the OARs sparing and intrafractional variation as a function of prolonged treatment time, the authors recommend to use the 6XFFF beam in the 4*12 Gy and 3*18 Gy schemes for better OARs sparing. However, for the 1*34 Gy scheme, the 10XFFF beam is recommended to achieve improved treatment efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A two-stage method for microcalcification cluster segmentation in mammography by deformable models

Purpose: Segmentation of microcalcification (MC) clusters in x-ray mammography is a difficult task for radiologists. Accurate segmentation is prerequisite for quantitative image analysis of MC clusters and subsequent feature extraction and classification in computer-aided diagnosis schemes. Methods: In this study, a two-stage semiautomated segmentation method of MC clusters is investigated. The first stage is targeted to accurate and time efficient segmentation of the majority of the particles of a MC cluster, by means of a level set method. The second stage is targeted to shape refinement of selected individual MCs, by means of an active contour model. Both methods are applied in the framework of a rich scale-space representation, provided by the wavelet transform at integer scales. Segmentation reliability of the proposed method in terms of inter and intraobserver agreements was evaluated in a case sample of 80 MC clusters originating from the digital database for screening mammography, corresponding to 4 morphology types (punctate: 22, fine linear branching: 16, pleomorphic: 18, and amorphous: 24) of MC clusters, assessing radiologists’ segmentations quantitatively by two distance metrics (Hausdorff distance—HDIST{sub cluster}, average of minimum distance—AMINDIST{sub cluster}) and the area overlap measure (AOM{sub cluster}). The effect of the proposed segmentation method on MC cluster characterization accuracy was evaluated in a case sample of 162 pleomorphic MC clusters (72 malignant and 90 benign). Ten MC cluster features, targeted to capture morphologic properties of individual MCs in a cluster (area, major length, perimeter, compactness, and spread), were extracted and a correlation-based feature selection method yielded a feature subset to feed in a support vector machine classifier. Classification performance of the MC cluster features was estimated by means of the area under receiver operating characteristic curve (Az ± Standard Error) utilizing tenfold cross-validation methodology. A previously developed B-spline active rays segmentation method was also considered for comparison purposes. Results: Interobserver and intraobserver segmentation agreements (median and [25%, 75%] quartile range) were substantial with respect to the distance metrics HDIST{sub cluster} (2.3 [1.8, 2.9] and 2.5 [2.1, 3.2] pixels) and AMINDIST{sub cluster} (0.8 [0.6, 1.0] and 1.0 [0.8, 1.2] pixels), while moderate with respect to AOM{sub cluster} (0.64 [0.55, 0.71] and 0.59 [0.52, 0.66]). The proposed segmentation method outperformed (0.80 ± 0.04) statistically significantly (Mann-Whitney U-test, p < 0.05) the B-spline active rays segmentation method (0.69 ± 0.04), suggesting the significance of the proposed semiautomated method. Conclusions: Results indicate a reliable semiautomated segmentation method for MC clusters offered by deformable models, which could be utilized in MC cluster quantitative image analysis.

60 APPLIED LIFE SCIENCES↗

SU-F-T-356: DosimetricComparison of VMAT Vs Step and Shoot IMRT Plans for Stage III Lung CancerPatients with Mediastinal Involvement

Purpose: For Stage III lung cancers that entail treatment of some or all of the mediastinum, anterior-posterior focused Step and Shoot IMRT (SS-IMRT) and VMAT plans have been clinically used to deliver the prescribed dose while working to minimize lung dose and avoid other critical structures. A comparison between the two planning methods was completed to see which treatment method is superior and minimizes dose to healthy lung tissue. Methods: Ten patients who were recently treated with SS-IMRT or VMAT plans for Stage III lung cancer with mediastinal involvement were selected. All patients received a simulation CT for treatment planning, as well as a 4D CT and PET/CT fusion for target delineation. Plans were prescribed 6250 cGy in 25 fractions and normalized such that 100% of the prescription dose covered 95% of the PTV. Clinically approved SS-IMRT or VMAT plans were then copied and planned using the alternative modality with identical optimization criteria. SS-IMRT plans utilized seven to nine beams distributed around the patient while the VMAT plans consisted of two full 360 degree arcs. Plans were compared for the lung volume receiving 20 Gy (V20). Results: Both SS-IMRT and VMAT can be used to achieve clinical treatment plans for patients with Stage III Lung cancer with targets encompassing the mediastinum. VMAT plans produced an average V20 of 23.0+/−8.3% and SS-IMRT produced an average of 24.2+/−10.0%. Conclusion: Results indicate that either method can achieve comparable dose distributions, however, VMAT can allow the optimizer to distribute dose over paths of minimal lung tissue and reduce the V20. Therefore, creating a VMAT with constraints identical to an SS-IMRT plan could help to reduce the V20 in clinical treatment plans.

60 APPLIED LIFE SCIENCES↗

A Posteriori Error Analysis of Two-Stage Computation Methods with Application to Efficient Discretization and the Parareal Algorithm

We consider numerical methods for initial value problems that employ a two stage approach consisting of solution on a relatively coarse discretization followed by solution on a relatively fine discretization. Examples include adaptive error control, parallel-in-time solution schemes, and efficient solution of adjoint problems for computing a posteriori error estimates. We describe a general formulation of two stage computations then perform a general a posteriori error analysis based on computable residuals and solution of an adjoint problem. The analysis accommodates various variations in the two stage computation and in formulation of the adjoint problems. We apply the analysis to compute “dual-weighted” a posteriori error estimates, to develop novel algorithms for efficient solution that take into account cancellation of error, and to the Parareal Algorithm. We test the various results using several numerical examples.

97 MATHEMATICS AND COMPUTING↗

staged-script

SAND2024-13810O staged-script is a Python package that assists users in developing automation scripts, subdivided into a series of stages for improving replicability. Though staged-script makes creating straightforward scripts simple, the package also provides optional, significant power-user flexibility. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Gates, Jason↗

SentimagIC: A Non-inferiority Trial Comparing Superparamagnetic Iron Oxide Versus Technetium-99m and Blue Dye in the Detection of Axillary Sentinel Nodes in Patients with Early-Stage Breast Cancer

Background: Sentinel lymph node biopsy (SLNB) is a highly accurate method for staging the axilla in early breast cancer. Superparamagnetic iron oxide mapping agents have been explored to overcome the disadvantages of the standard SLNB technique, which uses a radioisotope tracer with or without blue dye. One such agent, Sienna+, was shown to be non-inferior to the standard technique for SLNB in a number of studies. The SentimagIC trial was designed to establish the non-inferiority of a new formulation of this magnetic tracer, Magtrace (formerly SiennaXP). Methods: Patients with clinically node-negative early-stage breast cancer were recruited from six centers in the US. Patients received radioisotope and isosulfan blue dye injections, followed by an intraoperative injection of magnetic tracer, prior to SLNB. The sentinel node identification rate was compared between the magnetic and standard techniques to evaluate non-inferiority and concordance. Results: Data were collected for 146 procedures in 146 patients. The per patient detection rate was 99.3% (145/146) when using the magnetic tracer and 98.6% (144/146) when using the standard technique, while the nodal detection rate was 94.3% (348/369 nodes) when using the magnetic tracer and 93.5% (345/369) when using the standard technique (difference 0.8%, 95% binomial confidence interval lower bound − 2.1%). Of the 22 patients with positive sentinel lymph nodes (SLNs), 21 (95.4%) were detected by both the magnetic tracer and the standard technique. All malignant nodes detected by standard technique were also identified by the magnetic technique. Conclusion: The magnetic technique is non-inferior to the standard technique of radioisotope and blue dye for axillary SLN detection in early-stage breast cancer. The magnetic technique is therefore a viable alternative.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Staging for Distant Metastases in Breast Cancer Patients with Confirmed Local and/or Locoregional Recurrence: How Useful are Current Guideline Recommendations?

Background: Breast cancer patients with local and/or locoregional recurrence (LR) are at higher risk of developing distant metastases (DM) at a later time. Once LR has been confirmed, some international interdisciplinary guidelines recommend performing radiological examinations for DM to determine the course of further therapy (curative or palliative approach). This study analyzed the metastatic patterns of patients with LR with particular regard to the frequency of concurrent diagnosis of LR and DM; in other words: are radiological staging procedures actually justified for DM at the time of diagnosis of LR? Methods: This study included all patients (n = 1368) who were diagnosed and treated for nonmetastatic breast cancer (Stage I–III) at the University Women’s Hospital Basel, Switzerland between 1990 and 2009. Results: In 137 patients, LR was diagnosed without a history of DM: in-breast/thoracic wall only, n = 90 (65.7%); involvement of axillary/supra-/infraclavicular lymph nodes, n = 47 (34.3%). DM was found at the time of diagnosis of LR in 44 patients (32.1%). Concurrent diagnosis of LR and DM occurred significantly more often in patients with lymph node recurrence compared with those with in-breast/chest wall recurrence (48.9% vs. 23.3%; p = 0.004). Conclusions: Approximately one-third of patients with a LR had synchronous DM at the time of their local/locoregional event. For this reason, routine systemic staging imaging at the time of LR should be an absolute requirement for planning further therapy. Confirmation of DM may spare the patients radical surgical interventions with questionable impact on survival in the face of an incurable disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

T staging esophageal tumors with x rays

With histopathology results typically taking several days, the ability to stage tumors during interventions could provide a step change in various cancer interventions. X-ray technology has advanced significantly in recent years with the introduction of phase-based imaging methods. These have been adapted for use in standard labs rather than specialized facilities such as synchrotrons, and approaches that enable fast 3D scans with conventional x-ray sources have been developed. This opens the possibility to produce 3D images with enhanced soft tissue contrast at a level of detail comparable to histopathology, in times sufficiently short to be compatible with use during surgical interventions. In this paper we discuss the application of one such approach to human esophagi obtained from esophagectomy interventions. We demonstrate that the image quality is sufficiently high to enable tumor T staging based on the x-ray datasets alone. Alongside detection of involved margins with potentially life-saving implications, staging tumors intra-operatively has the potential to change patient pathways, facilitating optimization of therapeutic interventions during the procedure itself. Besides a prospective intra-operative use, the availability of high-quality 3D images of entire esophageal tumors can support histopathological characterization, from enabling “right slice first time” approaches to understanding the histopathology in the full 3D context of the surrounding tumor environment.

Optics↗

Many but not all deep neural network audio models capture brain responses and exhibit correspondence between model stages and brain regions

Models that predict brain responses to stimuli provide one measure of understanding of a sensory system and have many potential applications in science and engineering. Deep artificial neural networks have emerged as the leading such predictive models of the visual system but are less explored in audition. Prior work provided examples of audio-trained neural networks that produced good predictions of auditory cortical fMRI responses and exhibited correspondence between model stages and brain regions, but left it unclear whether these results generalize to other neural network models and, thus, how to further improve models in this domain. We evaluated model-brain correspondence for publicly available audio neural network models along with in-house models trained on 4 different tasks. Most tested models outpredicted standard spectromporal filter-bank models of auditory cortex and exhibited systematic model-brain correspondence: Middle stages best predicted primary auditory cortex, while deep stages best predicted non-primary cortex. However, some state-of-the-art models produced substantially worse brain predictions. Models trained to recognize speech in background noise produced better brain predictions than models trained to recognize speech in quiet, potentially because hearing in noise imposes constraints on biological auditory representations. The training task influenced the prediction quality for specific cortical tuning properties, with best overall predictions resulting from models trained on multiple tasks. The results generally support the promise of deep neural networks as models of audition, though they also indicate that current models do not explain auditory cortical responses in their entirety.

59 BASIC BIOLOGICAL SCIENCES↗

Following iron speciation in the early stages of magnetite magnetosome biomineralization

Understanding magnetosome magnetite biomineralization is of fundamental interest to devising the strategies for bioinspired synthesis of magnetic materials at the nanoscale. Thus, we investigated the early stages of magnetosome formation in this work and correlated the size and emergent crystallinity of magnetosome nanoparticles with the changes in chemical environment of iron and oxygen by utilizing advanced analytical electron microscopy techniques. We observed that magnetosomes in the early stages of biomineralization with the sizes of 5–10 nm were amorphous, with a majority of iron present as Fe 3+ , indicative of ferric hydroxide. The magnetosomes with intermediate sizes showed partially crystalline structure with a majority of iron present as Fe 3+ and trace amounts of Fe 2+ . The fully maturated magnetosomes were indexed to magnetite. Furthermore, our approach provides spatially resolved structural and chemical information of individual magnetosomes with different particle sizes, attributed to magnetosomes at different stages of biomineralization.

59 BASIC BIOLOGICAL SCIENCES↗

Irradiation at Different Fetal Stages Results in Different Translocation Frequencies in Adult Mouse Thyroid Cells

While it is generally believed that fetuses are at high risk of developing cancers, including leukemia, after low doses of radiation, it has been reported that atomic bomb survivors exposed in utero did not show a dose response for translocations in blood T lymphocytes when they were examined at approximately 40 years of age. Subsequent mouse studies confirmed that animals irradiated during the fetal stage did not show evidence of radiation effects in lymphocytes and bone marrow cells when they were examined after reaching adulthood. However, in a study of rat mammary epithelial cells, radiation effects were clearly observed after fetal irradiation. These results indicate that the fate of chromosome aberrations induced in a fetus could vary among different tissues. Here we report on translocation frequencies in mouse thyroid cells, which were irradiated at different stages of fetal development. Cytogenetic examination was then conducted using fluorescence in situ hybridization (FISH) painting of chromosomes 1 and 3. Adult mice, 2 Gy X-ray irradiated at 15.5-day-old fetuses (E15.5), showed a higher translocation frequency (30/1,155 or 25.3 x 10 -3 ) than nonirradiated adult controls (0/1,007 or 0.1 x 10 -3 ), and was near that experienced by irradiated mothers and non-pregnant adult females (43/1,244 or 33.7 x 10 -3 ). These results are consistent with those seen in rat mammary cells. However, when fetuses were irradiated at an earlier stage of development (E6.5) before thyroid organogenesis, the resulting observed translocation frequency was much lower (3/502 or 5.8 x 10 -3 ) than that in E15.5 mice. These results suggest that after fetal irradiation, tissue stem cells record radiation effects primarily when the exposure occurs in cells that have been integrated into tissue. Embryonic stem cells that have been damaged prior to integration into the niche may undergo negative selection due to apoptosis, mitotic death or stem cell-niche cell interactions. The implications of these results in interpreting cancer risks after fetal irradiation are also discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Long-Period, Long-Duration Seismic Events and Their Probable Role in Reservoir Stimulation and Stage Productivity

Hydraulic fracturing is a well-established technique to extract gas or liquid hydrocarbons from low-permeability formations like shale and tight gas reservoirs. Diffusion of hydrofracturing fluid outward from the stimulated fractures into the target formation produces slip across preexisting fractures and other discontinuities in the rock. Microseismic events recorded by downhole seismic monitoring arrays are a manifestation of associated deformation. Recent investigations suggest that the total cumulative seismic moment of microearthquakes during hydraulic fracturing is only a small portion of the total seismic energy release expected for the fluid volume injected into the formation. These observations suggest that other sources of energy release (such as inelastic deformation), contemporaneous with microseismicity, should be considered as relevant to the hydraulic fracturing process. Recent observations on long period, long duration (LPLD) seismic events suggest that slow slip emission along weaknesses that are misaligned with respect to the present-day stress field are likely an important mechanism of deformation and should be better understood and quantified in reservoir stimulations. In Morgantown, West Virginia, we carried out seismic monitoring of hydraulic fracturing activity using an array of five broadband, three-component surface seismometers. Using this network, we identified 89 high-amplitude, impulsive events and 436 long period, long duration (LPLD) events, with highly emergent waveform characteristics. In these interpreted LPLD events, we observed a significant concentration of energy in the 0.8-3 Hz frequency range. During hydraulic fracturing, LPLD events were found to occur most frequently when the pumping pressure and rate were at or near maximum values. As the main purpose of hydraulic fracturing is to stimulate oil and gas production from the less permeable reservoir, we compared the relative production contribution per stage to the frequency of occurrence of suspected LPLD events. We found positive correlation between the frequency of LPLD events and stage-by-stage gas production, highlighting the potential contribution of slow deformation processes and its effectiveness in the reservoir stimulation.

58 GEOSCIENCES↗

Remote Evaluation of a Three-Stage 5 cm Annular Centrifugal Contractor Remote Module at the INL

Development work using Annular Centrifugal Contactors (ACCs) to process spent nuclear fuel supporting Global Nuclear Energy Partnership (GNEP) program goals continues at the Idaho National Laboratory (INL). Previous work has resulted in defining and characterizing the performance of 5 cm and 12.5 cm single-stage units in a “cold” environment. The next logical step is to investigate the implementation of ACCs in a “hot” or radioactive environment. Following the design, construction, and hydraulic testing of a three-stage prototype module, the evaluation of the equipment design for use in remote environments was necessary. A remote evaluation of a three-stage CINC V-02 remote prototype module has successfully been completed. The evaluation included multiple removal and re-insertion iterations for each rotor/motor assembly. The iterations were performed using both master-slave (MSM) and electromechanical manipulators (EMM) in a remote mockup test facility. Results from the evaluation indicated that the rotor/motor assemblies can be effectively removed and re-installed with both the MSM and EMM equipment. The EMM is considered to be a better choice for rotor/motor assembly changeout due to a 20 pound at-wrist load capacity associated with the MSM. The sampling evaluation indicated the MSM would be a good choice for smaller, more intricate remote handling activities. A thorough investigation of remote operations personnel capabilities was not performed as the evaluations were considered quite routine as stated by the operator performing the lifts. Following the execution of the lifts, the equipment operator suggested two minimal modifications that would further ease rotor/motor changeouts. The first modification would be to simply re-position the lifting bail so the rotor/motor assembly hangs more vertical which better aligns the assembly when re-installing in the housing. The second modification is to add an additional ¼ to ½ in. length to the rear guide pin. This is a routinely practiced design addition that saves time and provides better alignment of a rotor/motor assembly prior to lowering into the housing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Approximating Joint Chance Constraints in Two-Stage Stochastic Programs

We present various approximations to joint chance constraints arising in two-stage stochastic programming models. Our approximations are derived from three classical inequalities: Markov's inequality, Chebysev's inequality, and Chernoff's bound. We provide preliminary computational results illustrating the quality of our approximation using a two-stage joint-chance-constrained stochastic program from the literature. We also briefly introduce other alternatives for constructing approximations for joint-chance-constrained two-stage programs.

97 MATHEMATICS AND COMPUTING↗

Staged OMB for Modular Gasifier/Burner

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0031506. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) has developed a staged opposed multi-burner (OMB) gasifier, scaled down from a commercial gasification technology to utilize coal slurry as feed for the high-temperature gasification. The project involved the design, fabrication, commissioning, parametric testing, and performance validation of the entrained gasifier with multiple burners to narrow the major near-term technical gaps that impede the application of small-size gasification by modularizing the system. Project results verified the UK CAER approach to address the major technical challenges on the gasification modularization for a distributed application at a small scale of 1-5 MWe, while maintaining advantages in cost and flexibility, which include: 1) a cost-effective burner configuration to provide high flexibility in both load and fuel feed; 2) the modularized staged-OMB to provide better gasification performance such as a desired temperature profile, better fuel conversion, better gasification efficiency, and long lifetimes of the refractory wall and burners; and 3) load control simply through changing the number of burners firing. UK CAER’s staged gasifier configuration, fuel blend performance, and economic evaluation shows promise, as summarized in this report, as an effective means for improved gasification efficiency with reduced operation cost and process complexity.

01 COAL, LIGNITE, AND PEAT↗

Modeling and Optimizing Pumped Storage in a Multi-stage Large Scale Electricity Market under Portfolio Evolution

To leverage the fast-ramping capability of resources to provide great value to the grid, electricity system operators such as the Midcontinent Independent System Operator (MISO) continue to evolve their approaches for integrating energy storage resources, including pumpedstorage hydro (PSH), into the electricity markets. However, new challenges arise in modeling and optimizing these energy-limited resources across multiple market clearing processes and planning studies with uncertainties and imperfect information. For instance, current market practices of PSH owners specifying pumping/generating hours can result in sub-optimal generation dispatch. Letting grid operators optimize PSH with the consideration of multiple operating modes and energy limitation constraints can potentially bring economic benefits to both the system and the PSH owners. However, in multi-stage clearing process of electricity markets, utilizing the PSH flexibility to deal with realized uncertainties can cause deviation in the multi-stage scheduling processes. The resulting financial risks from the schedule deviation may not be acceptable to PSH owners. In addition, to effectively utilize this energy limited resource, the state of charge (SOC) constraints of PSH needs to be continuously optimized and the marginal cost of deviation need to reflect the expected cost to purchase or sell energy at future times to compensate for deviations. This project aims to develop a prototype enhanced PSH model and improved price signals in the multi-stage market clearing process with proper consideration of the unique characteristics of PSH, in order to better align underlying PSH capabilities with evolving grid needs, particularly including the needs for more frequent and larger cycling to manage variability and uncertainty from renewables.

24 POWER TRANSMISSION AND DISTRIBUTION↗