Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

FY23 Post-LOCA Characterization of Irradiated Fuel (NSUF Award 17-12985)

This report summarizes the sample preparation and data collection on fuel pins following integral LOCA testing in the Severe Accident Test Station at Oak Ridge National Laboratory. The test sample cross-sections show post-transient fragmentation behavior of UO 2 commercially irradiated above 67 MWd/kgU. Ring compression testing and hydrogen measurements were collected on the cladding segments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observing strategy for the SDSS-IV/MaNGA IFU galaxy survey

Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) is an integral-field spectroscopic survey that is one of three core programs in the fourth-generation Sloan Digital Sky Survey (SDSS-IV). MaNGA’s 17 pluggable optical fiber-bundle integral field units (IFUs) will observe a sample of 10,000 nearby galaxies distributed throughout the SDSS imaging footprint (focusing particularly on the North Galactic Cap). In each pointing these IFUs are deployed across a 3° field; they yield spectral coverage 3600−10300 Å at a typical resolution R ∼ 2000, and sample the sky with 2″ diameter fiber apertures with a total bundle fill factor of 56%. Observing over such a large field and range of wavelengths is particularly challenging for obtaining uniform and integral spatial coverage and resolution at all wavelengths and across each entire fiber array. Data quality is affected by the IFU construction technique, chromatic and field differential refraction, the adopted dithering strategy, and many other effects. We use numerical simulations to constrain the hardware design and observing strategy for the survey with the aim of ensuring consistent data quality that meets the survey science requirements while permitting maximum observational flexibility. We find that MaNGA science goals are best achieved with IFUs composed of a regular hexagonal grid of optical fibers with rms displacement of 5 μm or less from their nominal packing position; this goal is met by the MaNGA hardware, which achieves 3 μm rms fiber placement. We further show that MaNGA observations are best obtained in sets of three 15 minute exposures dithered along the vertices of a 1.44 arcsec equilateral triangle; these sets form the minimum observational unit, and are repeated as needed to achieve a combined signal-to-noise ratio of 5 Å{sup −1} per fiber in the r-band continuum at a surface brightness of 23 AB arcsec{sup −2}. In order to ensure uniform coverage and delivered image quality, we require that the exposures in a given set be obtained within a 60 minute interval of each other in hour angle, and that all exposures be obtained at airmass ≲1.2 (i.e., within 1–3 hr of transit depending on the declination of a given field).

79 ASTRONOMY AND ASTROPHYSICS↗

Results Of Routine Strip Effluent Hold Tank, Decontaminated Salt Solution Hold Tank, Caustic Wash Tank And Caustic Storage Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 6 Operations

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Caustic Storage Tank (CST) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 6 have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results from the current microbatch samples are similar to those from comparable samples in Macrobatch 5. From a bulk chemical point of view, the ICPES results do not vary considerably between this and the previous macrobatch. The titanium results in the DSSHT samples continue to indicate the presence of Ti, when the feed material does not have detectable levels. This most likely indicates that leaching of Ti from MST in ARP continues to occur. Both the CST and CWT samples indicate that the target Free OH value of 0.03 has been surpassed. While at this time there is no indication that this has caused an operational problem, the CST should be adjusted into specification. The 137 Cs results from the SRNL as well as F/H lab data indicate a potential decline in cesium decontamination factor. Further samples will be carefully monitored to investigate this.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

ZTF-SEDm Type Ia supernova sample for Twins Embedding spectrophotometric standardization

Aims. This paper has two aims: the first aim is to build a large homogeneous spectrophotometric sample of Type Ia supernovae (SNe Ia) from the second data release of the Zwicky Transient Facility (ZTF DR2). We used the spectrum sample from the low-resolution ( R ∼ 100) SEDmachine (SEDm) Integral Field Spectrograph (IFS) that gathered 3069 spectra. This is one of the largest samples of such collections that can attempt to reproduce the Twins Embedding (TE) spectrophotometric standardization method. This is our second objective. The method was developed based on high-quality spectra from 200 SNe Ia of the Nearby Supernova factory (SNfactory) and led to an exceptionally low value of 0.073 mag for the intrinsic scatter. Methods. As the SEDm is not designed as a spectrophotometric instrument, we first improved the flux-calibration accuracy of the SN Ia spectrum sample using the ZTF photometric data, which were calibrated at the percent level. We corrected the spectra for second-order polynomials, fitted by comparing the synthetic photometry in the ZTF g , r , i filters with the light-curve (LC) data. We then applied the three steps of the TE parameterization to a subset of 783 ZTF SN spectra near maximum light while comparing results from SNfactory and ZTF. We finally analyzed the standardization methods based on the TE parameters. Results. The precision of the phase-correction model, which is the first step of the TE, is estimated at 0.01 mag in g band based on ZTF data. Despite the challenge posed by the spectrum-extraction pipeline associated with the SEDm (flux calibration, leftover host signal, low signal-to-noise ratio, and low resolution), we applied a first standardization in color based on the second step of the TE, called read between the lines (RBTL), to the ZTF sample. We reached a Hubble residual scatter of 0.153 mag, all in normalized median absolute deviation, which is to be compared to the ∼0.11 mag obtained with the SNfactory data. The SALT color and stretch standardization reaches a scatter of 0.164 mag for the same ZTF SN Ia sample, and its host steps are ∼0.1 mag and zero for RBTL. When considering the scatter due to the redshift error and flux calibration error, we estimated a RBTL scatter of ∼0.129 mag for this ZTF sample as an upper limit because we identified an additional contribution from a systematic error in color. We tested the standardization based on the nonlinear TE parameters, and, as expected from the low spectrum quality, it did not improve the overall dispersion. Conclusions. We release 1897 flux calibrated spectra of 1607 SNe Ia with an estimated photometric accuracy of 0.07 mag. We further demonstrate that some amount of spectrophotometric SN Ia standardization can be done with limited-quality spectra. The RBTL standardization is more efficient than that of SALT with one parameter less, and the resulting host steps are consistent with zero. This makes it less prone to astrophysical bias. For future spectroscopic surveys, targeting the extraction pipeline for a thorough flux calibration and good signal-to-noise ratio would enable us to compute the full TE standardization, which would further reduce the scatter in the distance estimate.

Ganot, C↗

Vacancy-type defects in Er-doped GaN studied by a monoenergetic positron beam

A relationship between intra-4f transitions of Er and vacancy-type defects in Er-doped GaN was studied by using a monoenergetic positron beam. Doppler broadening spectra of the annihilation radiation were measured for Er-doped GaN grown by molecular beam epitaxy. A clear correlation between the defect concentration and the photoluminescence (PL) intensity was observed. The major defect species detected by positrons was identified as a Ga vacancy V{sub Ga}, and its concentration increased with increasing Er concentration [Er]. For the sample with [Er]=3.3 at. %, the maximum integrated intensity of PL was observed. The V{sub Ga} concentration was above 10{sup 18} cm{sup -3} and additional vacancies such as divacancies started to be introduced at this Er concentration. For the sample with higher [Er], the PL intensity decreased, and the mean size of vacancies decreased due to an introduction of precipitates and/or metastable phases.

36 MATERIALS SCIENCE↗

Ice-nucleating particles (INPs) concentrations from SAIL-Net

This data set contains ice-nucleating particle (INP) concentration spectra collected during the SAIL-Net sampling period, which complemented the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign in the East River watershed near Crested Butte, Colorado. SAIL-Net was a distributed aerosol measurement network designed to investigate aerosol variability across complex mountainous terrain. The data set includes samples from multiple SAIL-Net sites, including AOS, Gothic, Snodgrass, Pumphouse, Irwin, and Top. INP concentrations are reported as a function of freezing temperature, together with confidence limits, sampling times, site location, elevation, sampled air volume, and treatment information. These data provide an analysis-ready record of the INPs across the SAIL-Net network.

activation temperature↗

Star Formation in the Local Universe from the CALIFA Sample. II. Activation and Quenching Mechanisms in Bulges, Bars, and Disks

We estimate the current extinction-corrected Hα star formation rate (SFR) of the different morphological components that shape galaxies (bulges, bars, and disks). We use a multicomponent photometric decomposition based on Sloan Digital Sky Survey imaging to Calar Alto Legacy Integral Field Area Integral Field Spectroscopy (IFS) datacubes for a sample of 219 galaxies. This analysis reveals an enhancement of the central SFR and specific SFR (sSFR = SFR/M {sub ⋆}) in barred galaxies. Along the main sequence, we find that more massive galaxies in total have undergone efficient suppression (quenching) of their star formation, in agreement with many studies. We discover that more massive disks have had their star formation quenched as well. We evaluate which mechanisms might be responsible for this quenching process. The presence of type 2 AGNs plays a role at damping the sSFR in bulges and less efficiently in disks. Also, the decrease in the sSFR of the disk component becomes more noticeable for stellar masses around 10{sup 10.5} M{sub ⊙}; for bulges, it is already present at ∼10{sup 9.5} M{sub ⊙}. The analysis of the line-of-sight stellar velocity dispersions (σ) for the bulge component and of the corresponding Faber–Jackson relation shows that AGNs tend to have slightly higher σ values than star-forming galaxies for the same mass. Finally, the impact of environment is evaluated by means of the projected galaxy density, Σ{sub 5}. We find that the SFR of both bulges and disks decreases in intermediate- to high-density environments. This work reflects the potential of combining IFS data with 2D multicomponent decompositions to shed light on the processes that regulate the SFR.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory time series moisture manipulative experiment from sediment across the contiguous US: time series aerobic respiration and geochemistry (v2)

This dataset supports a broader study examining the effects of wetting and drying on hyporheic zone respiration across the contiguous United States (CONUS). The dataset provides data generated from a laboratory moisture manipulation experiment. The contents include time series aerobic respiration and moisture; dissolved oxygen; sediment geochemistry data; and field metadata (including qualitative information on instream and river corridor characteristics). Samples were collected as part of the WHONDRS CONUS-Scale Model-Sample Study (CM). This study was designed following ICON (integrated, coordinated, open, and networked) principles to facilitate a model-experiment (ModEx) iteration approach, leveraging crowdsourced sampling across the CONUS. The data package associated with the CM study is available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689. CM sampling began in April 2022 and ended in October 2023. This study uses subsamples from a subset of CM samples collected between June 2022 and June 2023. The original field samples were labeled as CM_###. Subsequent subsamples for this study were labeled as EC_###. The labels from the field samples and the EC subsamples can be mapped directly based on the digits following the prefix and underscore (i.e., EC_001 is a subsample from CM_001). See the critical details section below for more details on sample naming. This data package was originally published in August 2024. It was updated in February 2026 (v2; new and modified files). See the change history section in the readme for more details. For details on how to navigate this data package, see this infographic from the River Corridor SFA https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data and one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) field protocol; and a (6) a subfolder with sediment sample data from the incubation experiment. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC); (2) total nitrogen (TN); (3) adenosine triphosphate (ATP); (4) percent carbon and nitrogen; (5) effect size; (6) iron (II); (7) gravimetric moisture; (8) respiration rates and raw dissolved oxygen values; (9) specific conductance; (10) pH; (11) temperature; (12) a summary containing median values of each data type for each treatment (wet and dry); (13) methods codes; (14) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla FTICR-MS data. This folder contains three subfolders, one containing the sediment .xml data files, one containing the sediment CoreMS output files, the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .ref, or .xml.

54 ENVIRONMENTAL SCIENCES↗

Sample Results from Routine Salt Batch 7 Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 7B have been analyzed for 238 Pu, 90 Sr, 137 Cs, Inductively Coupled Plasma Emission Spectroscopy (ICPES), and Ion Chromatography Anions (IC-A). The results from the current microbatch samples are similar to those from earlier samples from this and previous macrobatches. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal, and there is a distinct positive trend in Cs removal, due to the use of the Next Generation Solvent (NGS). The Savannah River National Laboratory (SRNL) notes that historically, most measured Concentration Factor (CF) values during salt processing have been in the 12-14 range. However, recent processing gives CF values closer to 11. This observation does not indicate that the solvent performance is suffering, as the Decontamination Factor (DF) has still maintained consistently high values. Nevertheless, SRNL will continue to monitor for indications of process upsets. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Results from final Salt Batch 9 Routine DSSHT and SEHT Monthly Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and in some cases anions (Ion Chromatography Anions - IC-A). These three samples are from Salt Batch 9 material in the Modular Caustic-Side Solvent Extraction Unit (MCU) system, and prior to actual Salt Batch 10 processing. These samples are known to contain contactor cleaning material and should not be considered typical for samples under operating conditions. While the DSSHT sample is typical of this type of sample, the SEHT samples indicate a gross inclusion of nitric acid, likely from contactor cleaning solutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative Ultrasound Characterization of Cancer Radiotherapy Effects In Vitro

Purpose: Currently, no routinely used imaging modality is available to assess tumor responses to cancer treatment within hours to days after radiotherapy. In this study, we demonstrate the preclinical application of quantitative ultrasound methods to characterize the cellular responses to cancer radiotherapy in vitro. Methods and Materials: Three different cell lines were exposed to radiation doses of 2-8 Gy. Data were collected with an ultrasound scanner using frequencies of 10-30 MHz. As indicators of response, ultrasound integrated backscatter and spectral slope were determined from the cell samples. These parameters were corrected for ultrasonic attenuation by measuring the attenuation coefficient. Results: A significant increase in the ultrasound integrated backscatter of 4-7 dB (p < 0.001) was found for radiation-treated cells compared with viable cells at all radiation doses. The spectral slopes decreased in the cell samples that predominantly underwent mitotic arrest/catastrophe after radiotherapy, consistent with an increase in cell size. In contrast, the spectral slopes did not change significantly in the cell samples that underwent a mix of cell death (apoptosis and mitotic arrest), with no significant change in average cell size. Conclusion: The changes in ultrasound integrated backscatter and spectral slope were direct consequences of cell and nuclear morphologic changes associated with cell death. The results indicate that this combination of quantitative ultrasonic parameters has the potential to assess the cell responses to radiation, differentiate between different types of cell death, and provide a preclinical framework to monitor tumor responses in vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coupling Microdroplet-Based Sample Preparation, Multiplexed Isobaric Labeling, and Nanoflow Peptide Fractionation for Deep Proteome Profiling of the Tissue Microenvironment

There is increasing interest in developing in-depth proteomic approaches for mapping tissue heterogeneity in a cell-type-specific manner to better understand and predict the function of complex biological systems such as human organs. Existing spatially resolved proteomics technologies cannot provide deep proteome coverage due to limited sensitivity and poor sample recovery. Herein, we seamlessly combined laser capture microdissection with a low-volume sample processing technology that includes a microfluidic device named microPOTS (microdroplet processing in one pot for trace samples), multiplexed isobaric labeling, and a nanoflow peptide fractionation approach. The integrated workflow allowed us to maximize proteome coverage of laser-isolated tissue samples containing nanogram levels of proteins. We demonstrated that the deep spatial proteomics platform can quantify more than 5000 unique proteins from a small-sized human pancreatic tissue pixel (∼60,000 μm2) and differentiate unique protein abundance patterns in pancreas. Furthermore, the use of the microPOTS chip eliminated the requirement for advanced microfabrication capabilities and specialized nanoliter liquid handling equipment, making it more accessible to proteomic laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample Results From Routine Salt Batch 7 Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 7B have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal, and there is a distinct positive trend in Cs removal (increasing cesium decontamination), due to the use of the Next Generation Solvent (NGS). The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Results from Routine DSSHT and SEHT Monthly Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 8B have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal for times when monosodium titanate (MST) is used. Even with no MST strike being performed there exists some small Pu and Sr removal, likely from filtration of fines containing these elements. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 16,400. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior. SRNL recommends that a sample of the strip feed be analyzed for cation and anion content if a further decline in boron concentration is noted in future SEHT samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical results from routine DSSHT and SEHT monthly samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 8B have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 22,100 (114% RSD). The bulk chemistry of the DSSHT and SEHT samples does not show any signs of unusual behavior, other than lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical results from salt batch 9 routine DSSHT and SEHT monthly samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be acceptable, with decontamination factors (DF) averaging 25700 (107% RSD). The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior, other than lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soft X‐Ray Absorption Spectroscopy With a Flat Liquid Jet in Vacuum Using a Table‐Top Laser‐Induced Plasma Source

ABSTRACT In this work, we demonstrate the integration of a flat liquid jet sample delivery system into a compact soft x‐ray absorption spectrometer using a table‐top laser‐induced plasma source. A high‐speed flat liquid sheet is formed by the collision of two cylindrical jets. This micrometer‐thin lamella can ideally be utilized for transmission‐mode soft x‐ray absorption spectroscopy using krypton plasma emission. Detailed analysis of the jet's thickness profile is achieved applying Lambert–Beer's law. Measurements on water, focusing on the oxygen K‐edge, reveal a lamella thickness profile ranging from 500 nm to 1 μm over a length of 3.8 mm. Additionally, we have investigated aqueous solutions of iron salts, capturing near edge x‐ray absorption fine structure spectra over a broad spectral range from the nitrogen K‐edge to the iron L‐edge. Focused analysis on iron species in aqueous solutions enabled us to distinguish quantitatively between the oxidation states of Fe 2+ and Fe 3+ at the iron L‐edge. Our results are compared with measurements obtained under similar conditions at a synchrotron.

Holburg, Jonathan [Department Optics/Short Wavelen↗