Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “root system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Acousto-ultrasonic measurements to monitor damage during fatigue of composites

An acousto-ultrasonic nondestructive testing method used to monitor damage during static and fatigue loading of thin graphite epoxy laminates is described. The experimental procedure, the signal analysis by the Fast Fourier Transform (FFT) algorithm, and the results of this analysis are discussed. Quasi-static tension tests showed a sharp decrease in the quantitative parameters when transverse cracks developed in the 90 degrees plies of a (0, 90/2/)s laminate. When internal micro-delaminations unite to form macro-delaminations, a sharp decrease in the parameters is also observed. The parameters are found to correlate well with other indications of damage development such as stiffness and degradation. The root mean square value of the moment is found to be more sensitive to damage than stiffness. Various signals and spectrums of graphite epoxy systems are presented.

Govada, A.↗

Implementation of the Boston University Space Physics Acquisition Center

The tasks carried out during this grant achieved the goals as set forth in the initial proposal. The Boston University Space Physics Acquisition CEnter (BUSPACE) now provides World Wide Web access to data from a large suite of both space-based and ground-based instruments, archived from different missions, experiments, or campaigns in which researchers associated with the Center for Space Physics (CSP) at Boston University have been involved. These archival data sets are in digital form and are valuable for retrospective data analysis studies of magnetospheric as well as ionospheric, thermospheric, and mesospheric physics. We have leveraged our grass-roots effort with the NASA seed money to establish dedicated hardware (computer and hard disk augmentation) and student support to grow and maintain the system. This leveraging of effort now permits easy access by the space physics community to many underutilized, yet important data sets, one example being that of the SCATHA satellite.

Spence, Harlan E.↗

Read You Loud and Clear! The Story of NASA's Spaceflight Tracking and Data Network

A historical account is provided of NASA's Spaceflight Tracking and Data Network (STDN), starting with its formation in the late 1950s to what it is today in the first decade of the 21st century. It traces the roots of the tracking network from its beginnings at the White Sands Missile Range in New Mexico to the Tracking and Data Relay Satellite System space-based constellation of today. The story spans the early days of satellite tracking using the Minitrack Network, through the expansion of the Satellite Tracking and Data Acquisition Network and the Manned Space Flight Network, and finally, to the Space and Ground networks of today. These accounts tell how international goodwill and foreign cooperation were crucial to the operation of the network and why the space agency chose to build the STDN as it did.

Tsiao, Sunny↗

NASA's Participation in Joint SatOPS Compatibility Efforts 2009-2010

Many U.S. government organizations build or fly space systems: a) NASA, NOAA, Navy, Air Force, NRO, ORS. Others? b) Through the Joint SatOps Compatibility Committee (JSCC) we have increased the grass-roots interaction between many of these organizations. c) We all deal with many of the same challenges: More rapid deployments, lower budgets; Advancing technologies - frameworks, clouds, virtualization; Evolving concepts - automation, situational awareness, enterprise mngt. Standardization - formal or by common use. There is an inherently governmental role in creating the business case for contractors and commercial product vendors to move in directions beneficial to multiple government space organizations.

Smith, Danford↗

Usability/Sentiment for the Enterprise and ENTERPRISE

The purpose of the Sentiment of Search Study for NASA Johnson Space Center (JSC) is to gain insight into the intranet search environment. With an initial usability survey, the authors were able to determine a usability score based on the Systems Usability Scale (SUS). Created in 1986, the freely available, well cited, SUS is commonly used to determine user perceptions of a system (in this case the intranet search environment). As with any improvement initiative, one must first examine and document the current reality of the situation. In this scenario, a method was needed to determine the usability of a search interface in addition to the user's perception on how well the search system was providing results. The use of the SUS provided a mechanism to quickly ascertain information in both areas, by adding one additional open-ended question at the end. The first ten questions allowed us to examine the usability of the system, while the last questions informed us on how the users rated the performance of the search results. The final analysis provides us with a better understanding of the current situation and areas to focus on for improvement. The power of search applications to enhance knowledge transfer is indisputable. The performance impact for any user unable to find needed information undermines project lifecycle, resource and scheduling requirements. Ever-increasing complexity of content and the user interface make usability considerations for the intranet, especially for search, a necessity instead of a 'nice-to-have'. Despite these arguments, intranet usability is largely disregarded due to lack of attention beyond the functionality of the infrastructure (White, 2013). The data collected from users of the JSC search system revealed their overall sentiment by means of the widely-known System Usability Scale. Results of the scores suggest 75%, +/-0.04, of the population rank the search system below average. In terms of a grading scaled, this equated to D or lower. It is obvious JSC users are not satisfied with the current situation, however they are eager to provide information and assistance in improving the search system. A majority of the respondents provided feedback on the issues most troubling them. This information will be used to enrich the next phase, root cause analysis and solution creation.

Meza, David↗

Analogy Between the Collatz Conjecture and Sliding Mode Control

The Collatz Conjecture is a famous mathematics problem that is simple to state and understand but remains unsolved. In this paper, the problem is recast as a discrete-time nonlinear system. and viewed in a new light from the perspective of nonlinear systems and feedback control theory. In particular, connections are made between the Collatz sequence of numbers and the behavior of closed-loop dynamical systems designed using a feedback control method called sliding mode control. Trajectories of such systems are characterized by a reaching phase and a sliding phase, the latter of which exhibits exponential convergence. As sliding mode control design is rooted in Lyapunov stability theory, the analogy suggests a new direction for proving or disproving the Collatz Conjecture. Although several possible approaches are discussed, no formal proof is given in this paper.

Collatz conjecture↗

Design of a multivariable flutter control/gust load alleviation system

This paper discusses the use of eigenspace techniques for the design of an active flutter control/gust load alleviation system for a hypothetical research drone. One leading edge and two trailing edge aerodynamic surfaces are available for control. Full state control laws are designed for two combinations of control surfaces by selecting feedback gains which place closed loop eigenvalues and shape closed loop eigenvectors so as to stabilize wing flutter and reduce gust loads at the wing root while yielding acceptable robustness and satisfying constraints on rms control surface activity. These controllers are realized by state estimators designed using an eigenvalue placement/eigenvector shaping technique which results in recovery of the loop transfer characteristics of the full state feedback systems. The resulting feedback compensators are shown to perform almost as well as the full state designs. They also exhibit acceptable performance in situations in which the failure of an actuator is simulated.

Liebst, B. S.↗

Scientific Visualization and Computational Science: Natural Partners

Scientific visualization is developing rapidly, stimulated by computational science, which is gaining acceptance as a third alternative to theory and experiment. Computational science is based on numerical simulations of mathematical models derived from theory. But each individual simulation is like a hypothetical experiment; initial conditions are specified, and the result is a record of the observed conditions. Experiments can be simulated for situations that can not really be created or controlled. Results impossible to measure can be computed.. Even for observable values, computed samples are typically much denser. Numerical simulations also extend scientific exploration where the mathematics is analytically intractable. Numerical simulations are used to study phenomena from subatomic to intergalactic scales and from abstract mathematical structures to pragmatic engineering of everyday objects. But computational science methods would be almost useless without visualization. The obvious reason is that the huge amounts of data produced require the high bandwidth of the human visual system, and interactivity adds to the power. Visualization systems also provide a single context for all the activities involved from debugging the simulations, to exploring the data, to communicating the results. Most of the presentations today have their roots in image processing, where the fundamental task is: Given an image, extract information about the scene. Visualization has developed from computer graphics, and the inverse task: Given a scene description, make an image. Visualization extends the graphics paradigm by expanding the possible input. The goal is still to produce images; the difficulty is that the input is not a scene description displayable by standard graphics methods. Visualization techniques must either transform the data into a scene description or extend graphics techniques to display this odd input. Computational science is a fertile field for visualization research because the results vary so widely and include things that have no known appearance. The amount of data creates additional challenges for both hardware and software systems. Evaluations of visualization should ultimately reflect the insight gained into the scientific phenomena. So making good visualizations requires consideration of characteristics of the user and the purpose of the visualization. Knowledge about human perception and graphic design is also relevant. It is this breadth of knowledge that stimulates proposals for multidisciplinary visualization teams and intelligent visualization assistant software. Visualization is an immature field, but computational science is stimulating research on a broad front.

Uselton, Samuel P.↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Self-organized Critical Behavior of the Plasma Sheet Reconnection Dynamics

Analyses of Polar UVI auroral image data reviewed in our other presentation at this meeting (V. Uritsky, A. Klimas) show that bright night-side high-latitude UV emissions exhibit so many of the key properties of systems in self-organized criticality (SOC) that an alternate interpretation has become virtually impossible. It is now necessary to find and model the source of this behavior. We note that the most common models of self-organized criticality are numerical sandpiles. These are, at root, models that govern the transport of some quantity from a region where it is loaded to another where it is unloaded. Transport is enabled by the excitation of a local threshold instability; it is intermittent and bursty, and it exhibits a number of scale-free statistical properties. Searching for a system in the magnetosphere that is analogous and that, in addition, is known to produce auroral signatures, we focus on the reconnection dynamics of the plasma sheet. In our previous work, a driven reconnection model has been constructed and has been under study. The transport of electromagnetic (primarily magnetic) energy carried by the Poynting flux into the reconnection region of the model has been examined. All of the analysis techniques, and more, that have been applied to the auroral image data have also been applied to this Poynting flux. Here, we report new results showing that this model also exhibits so many of the key properties of systems in self-organized criticality that an alternate interpretation is implausible. Further, we find a strong correlation between these key properties of the model and those of the auroral UV emissions. We suggest that, in general, the driven reconnection model is an important step toward a realistic plasma physical model of self-organized criticality and we conclude, more specifically, that it is also a step in the right direction toward modeling the multiscale reconnection dynamics of the magnetotail.

Klimas, Alex↗

Simulating sunflower canopy temperatures to infer root-zone soil water potential

A soil-plant-atmosphere model for sunflower (Helianthus annuus L.), together with clear sky weather data for several days, is used to study the relationship between canopy temperature and root-zone soil water potential. Considering the empirical dependence of stomatal resistance on insolation, air temperature and leaf water potential, a continuity equation for water flux in the soil-plant-atmosphere system is solved for the leaf water potential. The transpirational flux is calculated using Monteith's combination equation, while the canopy temperature is calculated from the energy balance equation. The simulation shows that, at high soil water potentials, canopy temperature is determined primarily by air and dew point temperatures. These results agree with an empirically derived linear regression equation relating canopy-air temperature differential to air vapor pressure deficit. The model predictions of leaf water potential are also in agreement with observations, indicating that measurements of canopy temperature together with a knowledge of air and dew point temperatures can provide a reliable estimate of the root-zone soil water potential.

Choudhury, B. J.↗

Artificial intelligence time series forecasting for feed-forward laser stabilization

Laser plasma accelerators, typically operating at 1–10 Hz repetition rates, have the ability to produce high-quality electron beams in compact, all-optical-driven configurations, with the electron beams uniquely suited for a wide variety of accelerator-based applications. However, fluctuations and drifts in the laser delivery to the meter-scaled and below plasma target (the electron beam source) will translate into electron beam source variations that can limit their utility for demanding applications like light sources or linear colliders. Commercially available active feedback laser stabilization systems are intrinsically bandwidth limited due to their integration with multi-inch corrective mirror mounts which minimizes their effectiveness. In this manuscript, we present a Neural Network time series forecaster that can predict laser position fluctuations of the laser delivery to the final target well ahead of a future laser shot. The Root-Mean-Square-Error (RMSE) of the prediction accuracy was < 2 μ m for a 1 / e 2 beam radius of 34 μ m . Our feed-forward approach serves as a first-step in circumventing the bandwidth limitations imposed by the currently available stabilization systems since it allows for mirrors to be moved into position ahead of time to offset the predicted future position drift. This will help advance laser plasma accelerator research by providing greater robustness and stability needed for its applications.

Berger, Curtis↗

EDNA: Expert fault digraph analysis using CLIPS

Traditionally fault models are represented by trees. Recently, digraph models have been proposed (Sack). Digraph models closely imitate the real system dependencies and hence are easy to develop, validate and maintain. However, they can also contain directed cycles and analysis algorithms are hard to find. Available algorithms tend to be complicated and slow. On the other hand, the tree analysis (VGRH, Tayl) is well understood and rooted in vast research effort and analytical techniques. The tree analysis algorithms are sophisticated and orders of magnitude faster. Transformation of a digraph (cyclic) into trees (CLP, LP) is a viable approach to blend the advantages of the representations. Neither the digraphs nor the trees provide the ability to handle heuristic knowledge. An expert system, to capture the engineering knowledge, is essential. We propose an approach here, namely, expert network analysis. We combine the digraph representation and tree algorithms. The models are augmented by probabilistic and heuristic knowledge. CLIPS, an expert system shell from NASA-JSC will be used to develop a tool. The technique provides the ability to handle probabilities and heuristic knowledge. Mixed analysis, some nodes with probabilities, is possible. The tool provides graphics interface for input, query, and update. With the combined approach it is expected to be a valuable tool in the design process as well in the capture of final design knowledge.

Dixit, Vishweshwar V.↗

Validation of Hygrothermal Simulations with Wall Performance Experiments in an Environmental Chamber

Oak Ridge National Laboratory is developing a web tool, built on a rule-based expert system, that aids stakeholders in designing energy-efficient moisture-durable walls. Currently, the tool’s expert system database is mostly populated with expert opinion, but work is being done to incorporate durability assessment based on stochastic hygrothermal modeling. Chamber experiments have been conducted to validate the hygrothermal models. The measured temperature and humidity have been compared with those predicted by the hygrothermal model. Experiments and comparison to one-dimensional hygrothermal modeling results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The two walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The walls were sequentially exposed to different scenarios, including diffusion, wetting, air leakage and solar radiation. For the most part, the hygrothermal simulations can be successfully used to predict the performance of these wall systems for the moisture transport phenomenon. Errors between measured and simulated values decreased as measurements got closer to the interior side of the wall. The root mean square error was larger for relative humidity (up to 17.5%-RH for CMU) than for temperature (up to 4.5°C for CMU wall). The errors were larger for the CMU wall than the wood frame wall. The phenomenon, including liquid water, caused large discrepancies between measurement and simulation results, and simulated results showed slower drying of materials than measured results. The one-dimensional nature of the simulation model made simulating air leaks difficult but not impossible.

Salonvaara, Mikael↗

Predicting initial trans-membrane pressure across cycles in the ultrafiltration process using random forest

With growing freshwater scarcity, direct potable reuse (DPR) systems that reclaim wastewater for drinking are becoming increasingly important for sustainable water supply. Reliable operation requires minimizing downtime in ultrafiltration (UF) units, where membrane fouling leads to elevated trans-membrane pressure (TMP). This study develops data-driven regression models based on random forest (RF) and autoregressive (AR) approaches to forecast the initial TMP at the start of each UF filtration cycle in a pilot-scale DPR system. The RF model consistently outperforms baseline methods, including historical mean, last observation carried forward, and AR models, across multiple forecast horizons, achieving the lowest root mean square error. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent input variables across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is assessed for both direct and recursive RF modelling approaches. The proposed RF framework establishes a robust foundation for predictive monitoring and real-time optimization of UF operations, supporting sustainable and reliable water reuse.

direct potable reuse↗

Crops for Carbon Farming

Agricultural cropping systems and pasture comprise one third of the world’s arable land and have the potential to draw down a considerable amount of atmospheric CO 2 for storage as soil organic carbon (SOC) and improving the soil carbon budget. An improved soil carbon budget serves the dual purpose of promoting soil health, which supports crop productivity, and constituting a pool from which carbon can be converted to recalcitrant forms for long-term storage as a mitigation measure for global warming. In this perspective, we propose the design of crop ideotypes with the dual functionality of being highly productive for the purposes of food, feed, and fuel, while at the same time being able to facilitate higher contribution to soil carbon and improve the below ground ecology. We advocate a holistic approach of the integrated plant-microbe-soil system and suggest that significant improvements in soil carbon storage can be achieved by a three-pronged approach: (1) design plants with an increased root strength to further allocation of carbon belowground; (2) balance the increase in belowground carbon allocation with increased source strength for enhanced photosynthesis and biomass accumulation; and (3) design soil microbial consortia for increased rhizosphere sink strength and plant growth-promoting (PGP) properties.

54 ENVIRONMENTAL SCIENCES↗

The development of spectro-signature indicators of root disease

The development and testing of airborne sensors that might be effective in discrimination root rot infected trees from healthy ones are outlined. The sensing device is composed of a thermal infrared radiometer and an instant replay video scan system.

Wear, J. F.↗