Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Development of a Space-Flight ADR Providing Continuous Cooling at 50 mK with Heat Rejection at 10 K

Future astronomical instruments will require sub-Kelvin detector temperatures to obtain high sensitivity. In many cases large arrays of detectors will be used, and the associated cooling systems will need performance surpassing the limits of present technologies. NASA is developing a compact cooling system that will lift heat continuously at temperatures below 50 mK and reject it at over 10 K. Based on Adiabatic Demagnetization Refrigerators (ADRs), it will have high thermodynamic efficiency and vibration-free operation with no moving parts. It will provide more than 10 times the current flight ADR cooling power at 50 mK and will also continuously cool a 4 K stage for instruments and optics. In addition, it will include an advanced magnetic shield resulting in external field variations below 5 µT. We describe the cooling system here and report on the progress in its development.

Tuttle, Jim↗

Vibration-Heating in ADR Kevlar Suspension Systems

The cryogenics group at NASA's Goddard Space Flight Center has a long-standing development and test program for laboratory and space-flight adiabatic demagnetization refrigerators (ADRs). These devices are used to cool components to temperatures as low as 0.05 K. At such low temperatures the ADR systems can provide a few micro-Watts of cooling power, so it is important to minimize the conduction of heat to these cold stages from the surroundings. The cold ADR elements are held in place by thin tensioned strings made of Kevlar, chosen for its high strength and stiffness and low thermal conductivity. During laboratory testing, we have observed that occasional significant additional heat loads on the coldest ADR stages correlate with unusually high vibration levels in the cryostat due to a noisy mechanical cryocooler. We theorized that this heat results from plastic deformation of the Kevlar fibers and frictional interactions among them, driven by the cryostat vibrations. We describe tests and calculations performed in attempt to confirm this source of the heating, and we discuss possible strategies to reduce this effect in future ADR suspension systems.

Vibration-heating↗

High Temperature Superconductor Lead Assemblies for XRISM

The RESOLVE instrument on the upcoming XRISM mission is a rebuild of the SXS instrument that successfully demonstrated high resolution X-ray spectroscopy on the Hitomi mission using a microcalorimeter array at 50 mK. As with SXS, the RESOLVE instrument requires High Temperature Superconductor (HTS) lead assemblies to carry high current to the Adiabatic Demagnetization Refrigerator (ADR) while meeting a very stringent heat conductance budget. For the RESOLVE HTS lead assemblies, we have used new materials and processes to improve the stability and consistency of solder joints to the HTS material. We have also designed a new thermal strap that eliminates stress concentrations on the HTS tapes. We present the results of testing on the engineering model and flight model units, as well as the results of long term testing on prototype solder joints.

Canavan, Edgar R.↗

Space Cold Chain: From Ground to the International Space Station and Back

Johnson Space Center uses a specialized Cold Box (Space Cooler) to keep items cool for delivery to and from the International Space Station. The Space Cooler is constructed out of several vacuum panels with aerogel cores. These panels are designed and constructed into a box shape for cold stowage purposes. The Space Cooler is optionally packed with cold bricks (phase-change material) as shown in the figure. This Space Cooler needs to perform without active refrigeration (passive only).

cryogenic engineering↗

Sub-Kelvin Cooling for Two Kilopixel Bolometer Arrays in the PIPER Receiver

The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne telescope mission to search for inflationary gravitational waves from the early universe. PIPER employs two 32 × 40 arrays of superconducting transition-edge sensors, which operate at 100 mK. An open bucket Dewar of liquid helium maintains the receiver and telescope optics at 1.7 K. We describe the thermal design of the receiver and sub-Kelvin cooling with a continuous adiabatic demagnetization refrigerator (CADR). The CADR operates between 70 and 130 mK and provides ≈10 μW cooling power at 100 mK, nearly five times the loading of the two detector assemblies. We describe electronics and software to robustly control the CADR, overall CADR performance in flightlike integrated receiver testing, and practical considerations for implementation in the balloon float environment.

Switzer, E. R.↗

Lynx X-Ray Microcalorimeter Cryogenic System

The Lynx x-ray microcalorimeter instrument on the Lynx X-ray Observatory requires a state-of-the-art cryogenic system to enable high-precision and high-resolution x-ray spectroscopy. The cryogenic system and components described provide the required environment using cooling technologies that are already at relatively high technology readiness levels and are progressing toward flight-compatible subsystems. These subsystems comprise a cryostat, a 4.5-K mechanical cryocooler, and an adiabatic demagnetization refrigerator that provides substantial cooling power at 50 mK.

DiPirro, Michael↗

Performance, reliability and life issues for components of the Planck Sorption Cooler

Continuous-duty hydrogen sorption cryocoolers are being developed for the European Space Agency (ESA) Planck mission. To achieve an acceptable level of performance and robust operation with these hydride refrigerators during flight, detailed investigations have been performed on the sorbent materials and on critical hardware components.

sorption↗

Low Temperature Characterization of Mechanical Isolators for Cryocoolers

For spacecraft applications requiring active refrigeration, exported vibrations from a cryocooler can be a concern. One approach to minimizing the vibrations transmitted from cryocoolers to the spacecraft is to mount them on mechanical isolators. Many commercial off-theshelf (COTS) mechanical isolators exist and have been characterized at room temperature for ground applications. However, the space environment presents challenges that complicate the selection process. Mechanical isolators in space must be made of materials that can withstand harsh radiation environments. Future instruments, such as the Mapping Imaging Spectrometer for Europa (MISE) on the Europa Clipper mission, are considering operating cryocoolers with low heat rejection temperatures and mounting them on mechanical isolators. However, the performance of many simple, traditional mechanical isolators at low temperatures is unknown. This paper describes the testing and results of various mechanical isolators able to withstand harsh radiation between 200 K and 300 K. The transmissibility of wire rope type isolators showed very little temperature dependence up to ~500 Hz. On the other hand, the transmissibility of silicone gel was strongly dependent on temperature as the material had an abrupt change in stiffness near its solid-solid phase change. Custom titanium flexures showed the most promise with a maximum transmissibility of 0.04 above 500 Hz and no expected temperature dependence.

Rodriguez, J.I.↗

Nutrient Stability in NASA Spaceflight Experiment Rodent Food Bars

Nutrient-upgraded Rodent Food Bars are the standard diet for mice involved in spaceflight experiments aboard the International Space Station as part of NASA’s Rodent Research Project. These Food Bars are a twin-screw extruded AIN-93G based product with nutrient additives to preserve a healthy and complete diet for the animals, and the bar form factor is necessary for use in the microgravity environment. Due to the nature of NASA flight projects and the lengthy production process of these Food Bars, a shelf-life assessment was undertaken to determine nutrient stability over an extended storage time. To assess palatability and stability over an extended duration, a panel of lipid oxidation markers and both fat- and water-soluble vitamins were assessed under various time and temperature conditions via AOAC International standardized methodology. Thiamine was the least stable vitamin at room temperature. Bars that had been continually kept at 4C (t=6, 12, 27 months) showed significantly higher levels of thiamine (via Student’s t-test) compared to all other bars that underwent some degree of ambient temperature storage. This suggests that refrigeration is a key component in maintaining adequate nutrient levels in these relatively high moisture (average 29.3%) food bars. Also of note was the level of Vitamin A in the form of retinol. There was no correlation to storage temperature, but rather the only factor having an effect on retinol levels was time. As low, yet consistent decrease in retinol was observed over the course of the experiment, though at no time did the retinol levels drop below the rodent Nutrient Requirements for Laboratory Animals (NRC). In conclusion, over the 27-month time course, all analyzed vitamins and lipid oxidation factors remained relatively stable and at levels which provide fully sufficient nutrition to rodents during spaceflight. Some groups however, displayed higher-than-expected aerobic and anaerobic bacteria colony forming units, which is believed to stem from a since-revised handling technique.

Food↗

Finding and Fixing a Small Low Temperature Leak - A Case Study on XRISM/Resolve

The Resolve instrument on the X-Ray Imaging and Spectroscopy Mission (XRISM) uses an Adiabatic Demagnetization Refrigerator (ADR) to cool extremely sensitive x-ray microcalorimeters to 50 mK. A 40-liter superfluid helium dewar and a 4.5 K Joule Thomson (JT)/Stirling cryocooler serve as heat sinks for the ADR and staged cooling for the dewar. The superfluid helium lifetime is required to last at least 3 years on orbit with margin. The superfluid helium dewar developed a small leak (~5e-7 Pa m^3/s) at low temperature which compromised the dewar vacuum in two days of ground testing. It turns out that this leak disappears completely at room temperature (<5e-13 Pa m^3/s). This presentation describes the lengthy process of characterizing, isolating, and ultimately, repairing this leak.

Michael DiPirro↗

Mechanically Tunable Radiative Cooling for Adaptive Thermal Control

Passive radiative cooling is currently thefrontier technology in renewable-energy research. Interms of extraterrestrial applications, radiative cooling is a critical component to the thermalmanagement system of a spacecraft, where the extreme environment of space can cause largetemperature variations that can break and damage equipment. For terrestrial applications,nocturnal or daytime radiative cooling is expected to lead to cost-effective passive heatmanagement without the need of inefficient and costly artificial refrigeration technologies.However, most currently available radiative cooling systems cannot be changed dynamically andradiate a constant static amount of thermal power. Dynamically tunable adaptive radiativecooling systems will be a critical development to prolong the lifetime of spacecraft or improvethe efficiency of terrestrial cooling systems. Here we propose stretchable radiative coolingdesigns that can be substantially tuned by using the simple physical mechanism of mechanical strain. When their structure is stretched, the radiated power is significantly reduced. We developa modeling method that can simulate mechanical stretching combined with electromagnetic response to compute the tunable thermal emission of these new adaptive radiative coolingsystems. The presented photonically engineered structures can be used as coatings to achieveefficient adaptive thermal control of various objects in a cost-effective and environmentallyfriendly way. The proposed designs are much simpler to be realized than others found in theliterature and the best design achieves a high thermal emission power with a tunable range on theorder of 132 W/m2.

Andrew Butler↗

Bayesian Assessment of Chlorofluorocarbon (CFC), Hydrochlorofluorocarbon (HCFC) and Halon Banks Suggest Large Reservoirs Still Present in Old Equipment

Halocarbons contained in equipment such as air conditioners, fire extinguishers, and foams continue to be emitted after production has ceased. These ‘banks’ within equipment and applications are thus potential sources of future emissions, and must be carefully accounted for in order to evaluate nascent production versus banked emissions. Here, we build on a probabilistic Bayesian model, previously developed to quantify CFC-11, 12 and 113 banks and their emissions. We extend this model to a suite of the major banked chemicals regulated under the Montreal Protocol (HCFC-22, HCFC-141b, and HCFC-142b, halon-1211, and halon-1301, and CFC-114 and CFC-115) along with CFC-11, 12 and 113 in order to quantify a fuller range of ozone-depleting substance banks by chemical and equipment type. We show that if atmospheric lifetime and prior assumptions are accurate, banks are very likely larger than previous international assessments suggest, and that total production has been very likely higher than reported. We identify that banks of greatest climate-relevance, as determined by global warming potential weighting, are largely concentrated in CFC-11 foams and CFC-12 and HCFC-22 non-hermetic refrigeration. Halons, CFC-11, and 12 banks dominate the banks weighted by ozone depletion potential. Thus, we identify and quantify the uncertainties in substantial banks whose future emissions will contribute to future global warming and delay ozone hole recovery if left unrecovered.

Halocarbons↗

Kennedy Space Center’s Energy and Water Conservation Program

America Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Space Coast Section - Our presenter will be Jennifer Hill, PE, LEED AP, Energy Manager for NASA at Kennedy Space Center. Ms. Hill will present on the NASA KSC Energy Program, providing an overview of KSC’s energy program and of projects that have been implemented to reduce energy and water intensity, increase renewable energy usage, and to improve resilience in support of the NASA KSC Mission.

Jennifer Hill↗

Passive Cooling in Aerogel-Based Insulation Systems for Liquid Hydrogen Upper Stage Launch Vehicle Tanks

Spray-On Foam Insulation (SOFI) is typically used to protect the windward-facing side of flight tanks for space launch vehicle liquid hydrogen (LH2) stages. SOFI is an excellent insulator in ambient pressure environments, however, its performance pales in comparison to reflective-type systems such as Multi-Layer Insulation in the thermal radiation dominated vacuum environment of space. If a windward insulation system employing radiation shields could be devised to replace or supplement SOFI, the on-orbit heat load could be drastically reduced, and the residual propellants could then be used to facilitate secondary missions. Such insulation systems, utilizing aerogel blanket insulation, have been explored by the Cryogenics Test Laboratory at NASA Kennedy Space Center. Owing to its nano-porous structure, aerogel is an excellent adsorbent as well as an insulator at cryogenic temperatures and will readily uptake condensable background gasses such as air when protecting a surface near LH2 temperatures. When an adsorbed blanket is rapidly exposed to a vacuum, such as during the ascent of a rocket, it will release the background gas, producing a passive cooling effect that could potentially reduce or eliminate the heat load on the propellant tank for a time. This work discusses the setup and results of a test program carried out to determine the effectiveness and impact of this cooling effect as it pertains to LH2 upper stage tanks. A vertical-cylindrical liquid nitrogen (LN2) calorimeter test instrument acted as the upper stage analog. The cold-mass was wrapped with two layers of 10 mm thick aerogel blanket material, with and without aluminum heat shields depending on the test, and interspersed with numerous thermocouple temperature sensors. Gaseous argon was used as a stand-in for air as the condensable background gas. The test procedure mimicked vehicle cryo-loading/stabilization, and ascent phases, with the ascent phase accomplished using parallel vacuum pumps. Results show that the desorption cooling effect was enough to not only eliminate the heat load on the LN2 cold-mass entirely, but further refrigerated the liquid below its boiling point.

A.M. Swanger↗

Active and Passive Storage Solutions for Low Temperature Lunar Sample Return

Active and passive thermal storage solutions to return lunar biological, physical science and/or geology samples to the Earth are under development. Temperature requirements for biological/physical science sample conditioning range from -100˚C to -153˚C and possibly down to -253˚C for geological samples. The lower limit for geological samples is derived from the temperature of permanently shadowed regions on the lunar surface and the sublimation temperature of specific volatiles of interest (i.e., H2O, NH3 and CH4). Individual samples for the lunar application are expected to be less than 50 kg with a 700 kg allowance for the container and refrigeration. Requiring no electrical power or heat rejection, passive approaches, comprised of high performance insulation and consumable Joule-Thompson cooling, may be preferred for shorter duration missions (< 30 days) to provide significant mass savings. Active storage approaches with cryogenic cooling may be necessary to preserve samples for longer periods of time. A notional passive storage concept with an internal vapor cooled shield is shown below. The vapor cooled shield contains the sample and is isolated from the outer container with concentric reflective rigid shields and conventional multi-layer and/or aerogel insulation on the outer layer. A special removable, insulating end cap to stow or retrieve the sample is included.

Lunar Sample Return↗

Updating the Thermal Vacuum Chambers at the NASA Johnson Space Center

Chambers A and B are two large thermal vacuum chambers at Johnson Space Center which enable space simulation for unmanned and human-rated missions, respectively. With the resurgence in deep space missions for scientific research and various private commercial ventures, these chambers are expected to be used frequently for at least the next decade. For qualifying the James Webb Space Telescope, upgrades to Chamber A were performed which included the addition of a 12.5 kW refrigeration system with helium shrouds capable of simulating deep space environment and an efficient and reliable LN2 natural flow thermosiphon system for the thermal shield. Continuous improvements since then have focused on ensuring operational readiness by modernizing the data acquisition, recording, controls, and visualization systems for both chambers and clean room. These upgrades will be the focus of this paper. Controlling the Cryochambers was enhanced by moving from a 32-bit SCADA system to a 64-bit architected system. Infrastructural changes involved installing redundant power circuits, adding new servers, network switches, and including load balancing with fail-over between servers to minimize downtime. Instead of distributed servers, 3 redundant servers are used to share configurations. Configurations are now kept in a shared SQL instance making it easy to deploy and maintain. During this upgrade process many sub-systems (PLCs and NI PXI interfaces to sensors) were upgraded from the prior OPC-DA to the more secure OPC-UA protocol. Cryo-system PLCs were updated to allow Ganni cycle floating pressure calculations from any cold box to be sent to any compressor. During the project, the team recreated over 70,000 live data points, 50000 historical data points, and 4000 alarms. Finally, the graphical interfaces were upgraded to support HTML 5 in conjunction shared pages were implemented reducing the total number of webpages by over 75%. These system updates reinvigorated the previous SCADA system which had reached its end of life. The same look and feel was maintained while providing operators with an updated interface to control, troubleshoot, and record. The new system architecture is more robust and easier to maintain creating a path forward to address remaining problem points and implement additional features.

Cody Schaefer↗

Energy of Fluid (EOF) Simulation of Large-Scale Densification and Solidification of Hydrogen

The current research develops a finite volume-based Computation Fluid Dynamic (CFD) model utilizing an Energy of Fluid (EOF) approach to generate a simulation of the densification of liquid hydrogen (LH2) in the Integrated Refrigeration and Storage (IRAS) experimental tank for the Ground Operations Demonstration Unit for Liquid Hydrogen Project (GODU-LH2) at the Kennedy Space Center (KSC). The computational code will integrate a commercial software pressure-based model with User Defined Functions (UDF) generated and added to the model. The modified model will solve the energy equation in terms of internal energy and provide temperature and pressure calculations for a given tank geometry. This method will decrease computational time when compared to the built-in commercially available Enthalpy solvers. Currently the research focused on utilizing User Defined Scalars (UDS) compared to the enthalpy model and a lumped node analysis to show the written UDS is as accurate as the built-in solvers, and the models will be verified using known solutions for solidification and validated with the experimental results from the Cryogenics Test Laboratory (CTL) at KSC for the IRAS densification process.

C. Mahony↗