Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The quest for improved air quality may push China to continue its CO 2 reduction beyond the Paris Commitment

China is challenged with the simultaneous goals of improving air quality and mitigating climate change. The “Beautiful China” strategy, launched by the Chinese government in 2020, requires that all cities in China attain 35 μg/m 3 or below for annual mean concentration of PM 2.5 (particulate matter with aerodynamic diameter less than 2.5 μm) by 2035. Meanwhile, China adopts a portfolio of low-carbon policies to meet its Nationally Determined Contribution (NDC) pledged in the Paris Agreement. Previous studies demonstrated the co-benefits to air pollution reduction from implementing low-carbon energy policies. Pathways for China to achieve dual targets of both air quality and CO 2 mitigation, however, have not been comprehensively explored. Here, we couple an integrated assessment model and an air quality model to evaluate air quality in China through 2035 under the NDC scenario and an alternative scenario (Co-Benefit Energy [CBE]) with enhanced low-carbon policies. Results indicate that some Chinese cities cannot meet the PM 2.5 target under the NDC scenario by 2035, even with the strictest end-of-pipe controls. Achieving the air quality target would require further reduction in emissions of multiple air pollutants by 6 to 32%, driving additional 22% reduction in CO 2 emissions relative to the NDC scenario. Results show that the incremental health benefit from improved air quality of CBE exceeds 8 times the additional costs of CO 2 mitigation, attributed particularly to the cost-effective reduction in household PM 2.5 exposure. The additional low-carbon energy polices required for China’s air quality targets would lay an important foundation for its deep decarbonization aligned with the 2 °C global temperature target.

54 ENVIRONMENTAL SCIENCES↗

Diversity and evolution of nitric oxide reduction in bacteria and archaea

Nitrous oxide is a potent greenhouse gas whose production is catalyzed by nitric oxide reductase (NOR) members of the heme-copper oxidoreductase (HCO) enzyme superfamily. We identified several previously uncharacterized HCO families, four of which (eNOR, sNOR, gNOR, and nNOR) appear to perform NO reduction. These families have novel active-site structures and several have conserved proton channels, suggesting that they might be able to couple NO reduction to energy conservation. We isolated and biochemically characterized a member of the eNOR family from the bacterium Rhodothermus marinus and found that it performs NO reduction. These recently identified NORs exhibited broad phylogenetic and environmental distributions, greatly expanding the diversity of microbes in nature capable of NO reduction. Phylogenetic analyses further demonstrated that NORs evolved multiple times independently from oxygen reductases, supporting the view that complete denitrification evolved after aerobic respiration.

Science & Technology - Other Topics↗

Cas3-Mediated Genome Reduction: Demonstration in Cupriavidus Necator H16 Improves Growth on Heterotrophic and Autotrophic Carbon Sources

Genome reduction is widely used to improve microbial bioprocessing hosts by reducing the burden of inessential physiology. Rationally identifying genomic regions that are dispensable or even detrimental to bioprocessing is challenged by our inability to map genome sequence to function across complex regulation and physiology. Thus, there is a need for tools that rapidly generate reduced genome strains with improved performance in process-relevant conditions. Here, we report a Cascade-Cas3-enabled method called TRIM3 that generates large deletions by targeting a randomly integrated transposon, enabling facile generation of a genome-reduced mutant library. Mutants with improved performance were isolated following growth-coupled selection and analyzed by long-read DNA sequencing to identify deletions in their genomes. We deploy this system iteratively in the industrial host Cupriavidus necator H16 on fructose and on formate. After two rounds of TRIM3, we isolate a strain containing a total reduction of 1.4 Mb (18.4% of the genome) that grows 25% faster in a bioreactor on fructose and a strain with a total reduction of 0.5 Mb (7.3% of the genome) that grows 14% faster on formate. This work demonstrates a method for random, iterative, growth-selectable genome reduction that represents a new avenue for large-scale genome modifications and the development of improved bioprocessing hosts.

09 BIOMASS FUELS↗

Functional roles of CymA and NapC in reduction of nitrate and nitrite by Shewanella putrefaciens W3-18-1

Shewanella putrefaciens W3-18-1 harbours two periplasmic nitrate reductase (Nap) gene clusters, NapC-associated nap-alpha (napEDABC) and CymA-dependent nap-beta (napDAGHB), for dissimilatory nitrate respiration. CymA is a member of the NapC/NirT quinol dehydrogenase family and acts as a hub to support different respiratory pathways, including those on iron [Fe(III)] and manganese [Mn(III, IV)] (hydr)oxide, nitrate, nitrite, fumarate and arsenate in Shewanella strains. However, in our analysis it was shown that another NapC/NirT family protein, NapC, was only involved in nitrate reduction, although both CymA and NapC can transfer quinol-derived electrons to a periplasmic terminal reductase or an electron acceptor. Furthermore, our results showed that NapC could only interact specifically with the Nap-alpha nitrate reductase while CymA could interact promiscuously with Nap-alpha, Nap-beta and the NrfA nitrite reductase for nitrate and nitrite reduction. To further explore the difference in specificity, site-directed mutagenesis on both CymA and NapC was conducted and the phenotypic changes in nitrate and nitrite reduction were tested. Our analyses demonstrated that the Lys-91 residue played a key role in nitrate reduction for quinol oxidation and the Asp-166 residue might influence the maturation of CymA. The Asp-97 residue might be one of the key factors that influence the interaction of CymA with the cytochromes NapB and NrfA.

59 BASIC BIOLOGICAL SCIENCES↗

Unexpected origin of the quantum efficiency reduction in long-wavelength (In,Ga)⁢N light-emitting diodes

Differential carrier lifetime (DCL) measurements were performed on c-plane In 𝑥 ⁢Ga 1−𝑥⁢ N/Ga⁢N single-quantum-well (QW) light-emitting diodes (LEDs) with varying indium-content QWs (x = 13.5%, 16%, 22%), emitting with violet, blue, and green wavelengths. The recombination lifetimes of LEDs were found to increase with increasing indium composition, resulting in increased carrier densities n measured by DCL. Extraction of the A coefficients, which are assumed to not vary with n, and of the effective B(n) and C(n) coefficients of the ABC model of the internal quantum efficiency (IQE) of QWs showed no significant changes in the A coefficient with increasing indium content [In] in the In 𝑥 ⁢Ga 1−𝑥 ⁢N QW, and a reduction in the B(n) and C(n) coefficients with increasing [In]. When looking at the Shockley-Read-Hall (SRH) recombination rate An, the radiative recombination rate B(n)𝑛 2 , and the Auger-Meitner (AM) recombination rate C(n)𝑛 3 , we observed that at any given n, the SRH rate is the same for the three [In] measured, while the radiative rate decreases (by up to approximately 9 times) and the AM rate decreases (by up to approximately 7 times) with increasing indium content. This shows that the larger reduction in radiative recombination rates relative to nonradiative recombination rates with increasing [In] is the largest contributor to the decreased quantum efficiencies of LEDs (the “green gap”) at any given n. While some of the reduction in the effective recombination coefficients B(n) and C(n) can be explained by the reduced wave-function overlaps of the QW with increasing indium content, the larger reduction of B(n) relative to C(n) motivates further study of the intrinsic recombination coefficients 𝐵 0 and 𝐶 0 of bulk In 𝑥 ⁢Ga 1−𝑥 ⁢N alloys and how they are related to the effective recombination coefficients B(n) and C(n) in QWs. The relative contributions of nonradiative recombination are enhanced at any given current density due to the sublinear relationship between the carrier density n and the current density. Thus, the solution to the green gap, up to any intrinsic limitations set by the indium content of the QW, from an IQE perspective, requires the design of long-wavelength (In,Ga)⁢N LEDs with improved wave-function overlaps that can operate with a lower carrier density at any given current density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluating the Performance of Integer Sum Reduction on an Intel GPU

Sum reduction is a primitive operation in parallel computing while SYCL is a promising heterogeneous programming language. In this paper, we describe the SYCL implementations of integer sum reduction using atomic functions, shared local memory, vectorized memory accesses, and parameterized workload sizes. Evaluating the reduction kernels shows that we can achieve 1.4X speedup over the open-source implementations of sum reduction for a sufficiently large number of integers on an Intel integrated GPU.

Jin, Zheming↗

DuoModel: Leveraging Reduced Model for Data Reduction and Re-Computation on HPC Storage

High-performance computing (HPC) applications generate large amounts of floating-point data that need to be stored and analyzed efficiently to extract the insights and advance knowledge discovery. With the growing disparities between compute and I/O, optimizing the storage stack alone may not suffice to cure the I/O problem. There has been a strong push in the HPC communities to perform data reduction before data is transmitted to storage in order to lower the I/O cost. However, as of now, neither lossless nor lossy compressors can achieve the adequate reduction ratio that is desired by applications. This paper proposes DuoModel, a new approach that leverages the similarity between the full and reduced application models, and further improve the data reduction ratio. DouModel further improves the compression ratio of state-of-the-art compressors via compressing the differences (termed as delta) between the data products of the two models. For data analytics, the high fidelity data can be re-computed by launching the reduced model and applying the compressed delta. Our evaluations confirm that DuoModel can further push the limit of data reduction while the high fidelity of data is maintained.

Luo, Huizhang (ORCID:0000000323920267)↗

Optimizing Piezoelectric Material Location and Size for Multiple-Mode Vibration Reduction of Turbomachinery Blades

Modern turbomachinery blades have extremely low inherent damping, which can lead to high transient vibrations and failure through high-cycle fatigue. Smart materials enable vibration reduction while meeting strict blade requirements such as weight and aerodynamic efficiency. In particular, piezoelectric-based vibration reduction offers the potential to reduce vibration semi-actively while simultaneously harvesting sufficient energy to power the implementation. The placement and the size of the piezoelectric material is critical to the vibration reduction capabilities of the system. Furthermore, the implementation should target multiple vibration modes. In this study, we develop a procedure to optimize electromechanical coupling across multiple vibration modes for a representative turbomachinery blade with surface-mounted piezoelectric patches. Experimental validation demonstrates good coupling across three targeted modes with a single piezoelectric patch. Placing the piezoelectric material in regions of high signed strain energy for all targeted modes enables vibration reduction across all of the targeted modes.

36 MATERIALS SCIENCE↗

Global System Reduction Order Modeling for Localized Feature Inclusion

The development of reduced-order models remains an active research area, despite advances in computational resources. Here we develop a novel order-reduction approach that is designed to incorporate isolated regions that contain, for example, nonlinearitites or accumulating damage. The approach is designed to use global modes of the overall system response, which are then naturally coupled to the response in the isolated region of interest. Two examples are provided to demonstrate both the accuracy and the computational efficiency of the proposed approach. The performance of this approach is compared to the exact response corresponding to a finite element simulation for the chosen problems. In addition, the accuracy and computational efficiency are shown relative to a standard Galerkin reduction based on the linear normal modes. It is found that the proposed reduction offer computational efficiency comparable to a Galerkin reduction, but more accurately represents the response of the system when both are compared to the finite element simulation.

42 ENGINEERING↗

A Discussion of Strength Reduction Factor Development for Thermal Aging Effect on Nuclear Structural Alloys

In consideration of structural alloy property deterioration during long-term exposure to elevated temperatures, the yield and ultimate tensile strength reduction factors are provided in the Boiler and Pressure Vessel Code Section III for nuclear reactor component design and operation analysis. Because the Gen IV reactor requirement of 40 ~ 60 years of service life makes it difficult to acquire such long exposure test data for developing the reduction factors, they must be derived from test data with relatively short exposure by predictive methods considered to be reasonably reliable. A novel approach with a physically-based model has recently been proposed for application to development of reduction factors for 9Cr-1Mo-V. In the model, contributors to the tensile strength are first identified and related to definite microstructural features of the alloy, then some physically-based methods are employed to simulate the microstructural evolution, and finally the model is assembled with test-data-calibrated parameters to generate the yield and ultimate tensile strength reduction factors covering elevated temperature exposure for up to 57 years. The approach is undoubtedly a trailblazing development that will, if proven reliable, lead to a paradigm shift in predicting thermal aging behavior of many other alloys. Its debut application to Section III, however, concerns nuclear safety and naturally warrants objective, impartial, and thorough technical scrutiny. In the present paper, the novel and conventional approaches are discussed. Necessary improvements to the novel approach are recommended for its application to nuclear structural component design and analysis, and for its potential expanded use to other alloys.

Ren, Weiju↗

Multiresolution edge detection using enhanced fuzzy c-means clustering for ultrasound image speckle reduction

Purpose: Speckle suppression in ultrasound (US) images of various anatomic structures via a novel speckle noise reduction algorithm. Methods: The proposed algorithm employs an enhanced fuzzy c-means (EFCM) clustering and multiresolution wavelet analysis to distinguish edges from speckle noise in US images. The edge detection procedure involves a coarse-to-fine strategy with spatial and interscale constraints so as to classify wavelet local maxima distribution at different frequency bands. As an outcome, an edge map across scales is derived whereas the wavelet coefficients that correspond to speckle are suppressed in the inverse wavelet transform acquiring the denoised US image. Results: A total of 34 thyroid, liver, and breast US examinations were performed on a Logiq 9 US system. Each of these images was subjected to the proposed EFCM algorithm and, for comparison, to commercial speckle reduction imaging (SRI) software and another well-known denoising approach, Pizurica's method. The quantification of the speckle suppression performance in the selected set of US images was carried out via Speckle Suppression Index (SSI) with results of 0.61, 0.71, and 0.73 for EFCM, SRI, and Pizurica's methods, respectively. Peak signal-to-noise ratios of 35.12, 33.95, and 29.78 and edge preservation indices of 0.94, 0.93, and 0.86 were found for the EFCM, SIR, and Pizurica's method, respectively, demonstrating that the proposed method achieves superior speckle reduction performance and edge preservation properties. Based on two independent radiologists’ qualitative evaluation the proposed method significantly improved image characteristics over standard baseline B mode images, and those processed with the Pizurica's method. Furthermore, it yielded results similar to those for SRI for breast and thyroid images significantly better results than SRI for liver imaging, thus improving diagnostic accuracy in both superficial and in-depth structures. Conclusions: A new wavelet-based EFCM clustering model was introduced toward noise reduction and detail preservation. The proposed method improves the overall US image quality, which in turn could affect the decision-making on whether additional imaging and/or intervention is needed.

60 APPLIED LIFE SCIENCES↗

SU-E-I-77: A Noise Reduction Technique for Energy-Resolved Photon-Counting Detectors

Purpose: Finding the optimal energy threshold setting for an energy-resolved photon-counting detector has an important impact on the maximization of contrast-to-noise-ratio (CNR). We introduce a noise reduction method to enhance CNR by reducing the noise in each energy bin without altering the average gray levels in the projection and image domains. Methods: We simulated a four bin energy-resolved photon-counting detector based on Si with a 10 mm depth of interaction. TASMIP algorithm was used to simulate a spectrum of 65 kVp with 2.7 mm Al filter. A 13 mm PMMA phantom with hydroxyapatite and iodine at different concentrations (100, 200 and 300 mg/ml for HA, and 2, 4, and 8 mg/ml for Iodine) was used. Projection-based and Image-based energy weighting methods were used to generate weighted images. A reference low noise image was used for noise reduction purposes. A Gaussian-like weighting function which computes the similarity between pixels of interest was calculated from the reference image and implemented on a pixel by pixel basis for the noisy images. Results: CNR improvement compared to different methods (Charge-Integrated, Photon-Counting and Energy-Weighting) and after noise reduction was highly task-dependent. The CNR improvement with respect to the Charge-Integrated CNR for hydroxyapatite and iodine were 1.8 and 1.5, respectively. In each of the energy bins, the noise was reduced by approximately factor of two without altering their respective average gray levels. Conclusion: The proposed noise reduction technique for energy-resolved photon-counting detectors can significantly reduce image noise. This technique can be used as a compliment to the current energy-weighting methods in CNR optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy.

60 APPLIED LIFE SCIENCES↗

TU-G-BRA-01: Assessing Radiation-Induced Reductions in Regional Lung Perfusion Following Stereotactic Radiotherapy for Lung Cancer

Purpose: The dose-dependent nature of radiation therapy (RT)-induced lung injury following hypo-fractionated stereotactic RT is unclear. We herein report preliminary results of a prospective study assessing the magnitude of RT-induced reductions in regional lung perfusion following hypo-fractionated stereotactic RT. Methods: Four patients undergoing hypo-fractionated stereotactic lung RT (SBRT: 12 Gy x 4 fractions or 10 Gy x 5 fractions) had a pre-treatment SPECT (single-photon emission computed tomography) perfusion scan providing a 3D map of regional lung perfusion. Scans were repeated 3–6 months post-treatment. Pre- and post SPECT scans were registered to the planning CT scan (and hence the 3D dose data). Changes in regional perfusion (counts per cc on the pre-post scans) were computed in regions of the lung exposed to different doses of radiation (in 5 Gy intervals), thus defining a dose-response function. SPECT scans were internally normalized to the regions receiving <5 Gy. Results: At 3 months post-RT, the changes in perfusion are highly variable. At 6 months, there is a consistent dose-dependent reduction in regional perfusion. The average percent decline in regional perfusion was 10% at 15–20 Gy, 20% at 20–25 Gy, and 30% at 25–30 Gy representing a relatively linear dose response with an approximate 2% reduction per Gray for doses in excess of 10 Gy. There was a subtle increase in perfusion in the lung receiving <10 Gy. Conclusion: Hypo-fractionated stereotactic RT appears to cause a dose-dependent reduction in regional lung perfusion. There appears to be a threshold effect with no apparent perfusion loss at doses <10 Gy, though this might be in part due to the normalization technique used. Additional data is needed from a larger number of patients to better assess this issue. This sort of data can be used to assist optimizing RT treatment plans that minimize the risk of lung injury. Partly supported by the NIH (CA69579) and the Lance Armstrong Foundation.

60 APPLIED LIFE SCIENCES↗

Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules using PET/CT images.

60 APPLIED LIFE SCIENCES↗

Method for simulating dose reduction in digital mammography using the Anscombe transformation

Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.

60 APPLIED LIFE SCIENCES↗

SU-F-J-74: High Z Geometric Integrity and Beam Hardening Artifact Assessment Using a Retrospective Metal Artifact Reduction (MAR) Reconstruction Algorithm

Purpose: To test the efficacy of a retrospective metal artifact reduction (MAR) reconstruction algorithm for a commercial computed tomography (CT) scanner for radiation therapy purposes. Methods: High Z geometric integrity and artifact reduction analysis was performed with three phantoms using General Electric’s (GE) Discovery CT. The three phantoms included: a Computerized Imaging Reference Systems (CIRS) electron density phantom (Model 062) with a 6.5 mm diameter titanium rod insert, a custom spine phantom using Synthes Spine hardware submerged in water, and a dental phantom with various high Z fillings submerged in water. Each phantom was reconstructed using MAR and compared against the original scan. Furthermore, each scenario was tested using standard and extended Hounsfield Unit (HU) ranges. High Z geometric integrity was performed using the CIRS phantom, while the artifact reduction was performed using all three phantoms. Results: Geometric integrity of the 6.5 mm diameter rod was slightly overestimated for non-MAR scans for both standard and extended HU. With MAR reconstruction, the rod was underestimated for both standard and extended HU. For artifact reduction, the mean and standard deviation was compared in a volume of interest (VOI) in the surrounding material (water and water equivalent material, ∼0HU). Overall, the mean value of the VOI was closer to 0 HU for the MAR reconstruction compared to the non-MAR scan for most phantoms. Additionally, the standard deviations for all phantoms were greatly reduced using MAR reconstruction. Conclusion: GE’s MAR reconstruction algorithm improves image quality with the presence of high Z material with minimal degradation of its geometric integrity. High Z delineation can be carried out with proper contouring techniques. The effects of beam hardening artifacts are greatly reduced with MAR reconstruction. Tissue corrections due to these artifacts can be eliminated for simple high Z geometries and greatly reduced for more complex geometries.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-02: A Preliminary Study Evaluating Beam-Hardening Artifact Reduction On CT Direct Electron-Density Images

Purpose: A prototype reconstruction algorithm that can provide direct electron density (ED) images from single energy CT scans is being currently developed by Siemens Healthcare GmbH. This feature can eliminate the need for kV specific calibration curve for radiation treatemnt planning. An added benefit is that beam-hardening artifacts are also reduced on direct-ED images due to the underlying material decomposition. This study is to quantitatively analyze the reduction of beam-hardening artifacts on direct-ED images and suggest additional clinical usages. Methods: HU and direct-ED images were reconstructed on a head phantom scanned on a Siemens Definition AS CT scanner at five tube potentials of 70kV, 80kV, 100kV, 120kV and 140kV respectively. From these images, mean, standard deviation (SD), and local NPS were calculated for regions of interest (ROI) of same locations and sizes. A complete analysis of beam-hardening artifact reduction and image quality improvement was conducted. Results: Along with the increase of tube potentials, ROI means and SDs decrease on both HU and direct-ED images. The mean value differences between HU and direct-ED images are up to 8% with absolute value of 2.9. Compared to that on HU images, the SDs are lower on direct-ED images, and the differences are up to 26%. Interestingly, the local NPS calculated from direct-ED images shows consistent values in the low spatial frequency domain for images acquired from all tube potential settings, while varied dramatically on HU images. This also confirms the beam -hardening artifact reduction on ED images. Conclusions: The low SDs on direct-ED images and relative consistent NPS values in the low spatial frequency domain indicate a reduction of beam-hardening artifacts. The direct-ED image has the potential to assist in more accurate organ contouring, and is a better fit for the desired purpose of CT simulations for radiotherapy.

60 APPLIED LIFE SCIENCES↗