Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “random testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

A Genome-Based Model to Predict the Virulence of Pseudomonas aeruginosa Isolates

ABSTRACT: Variation in the genome of Pseudomonas aeruginosa , an important pathogen, can have dramatic impacts on the bacterium’s ability to cause disease. We therefore asked whether it was possible to predict the virulence of P. aeruginosa isolates based on their genomic content. We applied a machine learning approach to a genetically and phenotypically diverse collection of 115 clinical P. aeruginosa isolates using genomic information and corresponding virulence phenotypes in a mouse model of bacteremia. We defined the accessory genome of these isolates through the presence or absence of accessory genomic elements (AGEs), sequences present in some strains but not others. Machine learning models trained using AGEs were predictive of virulence, with a mean nested cross-validation accuracy of 75% using the random forest algorithm. However, individual AGEs did not have a large influence on the algorithm’s performance, suggesting instead that virulence predictions are derived from a diffuse genomic signature. These results were validated with an independent test set of 25 P. aeruginosa isolates whose virulence was predicted with 72% accuracy. Machine learning models trained using core genome single-nucleotide variants and whole-genome k-mers also predicted virulence. Our findings are a proof of concept for the use of bacterial genomes to predict pathogenicity in P. aeruginosa and highlight the potential of this approach for predicting patient outcomes. IMPORTANCE Pseudomonas aeruginosa is a clinically important Gram-negative opportunistic pathogen. P. aeruginosa shows a large degree of genomic heterogeneity both through variation in sequences found throughout the species (core genome) and through the presence or absence of sequences in different isolates (accessory genome). P. aeruginosa isolates also differ markedly in their ability to cause disease. In this study, we used machine learning to predict the virulence level of P. aeruginosa isolates in a mouse bacteremia model based on genomic content. We show that both the accessory and core genomes are predictive of virulence. This study provides a machine learning framework to investigate relationships between bacterial genomes and complex phenotypes such as virulence.

59 BASIC BIOLOGICAL SCIENCES↗

An Efficient Multicore Implementation of a Novel HSS-Structured Multifrontal Solver Using Randomized Sampling

Here, we present a sparse linear system solver that is based on a multifrontal variant of Gaussian elimination and exploits low-rank approximation of the resulting dense frontal matrices. We use hierarchically semiseparable (HSS) matrices, which have low-rank off-diagonal blocks, to approximate the frontal matrices. For HSS matrix construction, a randomized sampling algorithm is used together with interpolative decompositions. The combination of the randomized compression with a fast ULV HSS factoriz ation leads to a solver with lower computational complexity than the standard multifrontal method for many applications, resulting in speedups up to 7 fold for problems in our test suite. The implementation targets many-core systems by using task parallelism with dynamic runtime scheduling. Numerical experiments show performance improvements over state-of-the-art sparse direct solvers. The implementation achieves high performance and good scalability on a range of modern shared memory parallel systems, including the Intel Xeon Phi (MIC). The code is part of a software package called STRUMPACK - STRUctured Matrices PACKage, which also has a distributed memory component for dense rank-structured matrices.

97 MATHEMATICS AND COMPUTING↗

Impact of the SSO-ASTRO Margin Guideline on Rates of Re-excision After Lumpectomy for Breast Cancer: A Meta-analysis

Background: One in five patients undergoing initial lumpectomy for invasive breast cancer subsequently undergoes re-excision or mastectomy. A lack of clarity of when to re-excise based on lumpectomy margin width contributes to this high rate of reoperation. We sought to determine the impact of the Society of Surgical Oncology (SSO) and American Society of Radiation Oncologist (ASTRO) margin guideline on reoperation rates after lumpectomy. The guideline recommended omission of routine re-excision in specimens with “no ink on tumor”. Methods: A systematic literature review was performed. For eligible studies, a random-effects model was used for a meta-analysis of lumpectomy re-excision prevalence before and after publication of the SSO-ASTRO margin guideline. Study heterogeneity was measured by the Cochran’s Q test. Results: Five institutional, one population-based, and one national registry study met inclusion requirements. Sample size per study ranged from 237 to 26,102. There was significant interstudy heterogeneity (Q = 19.779; p = 0.003). Pooled re-excision prevalence was 22% (confidence interval [CI] 20–23) before and 14% (CI 12–15) after guideline publication. With the pre-guideline re-excision prevalence used as the reference value, the associated odds ratio for re-excision after the guideline was 0.65 (CI 0.54–0.78; p < 0.0001). Conclusions: The findings of a 35% reduction in the odds of re-excision after the guideline publication and a reduction in re-excision prevalence from 22 to 14% supports the notion that the SSO-ASTRO margin guideline was impactful. These findings are congruent with the projected reductions in re-excision at the time of guideline publication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unified feature association networks through integration of transcriptomic and proteomic data

High-throughput multi-omics studies and corresponding network analyses of multi-omic data have rapidly expanded their impact over the last 10 years. As biological features of different types (e.g. transcripts, proteins, metabolites) interact within cellular systems, the greatest amount of knowledge can be gained from networks that incorporate multiple types of -omic data. However, biological and technical sources of variation diminish the ability to detect cross-type associations, yielding networks dominated by communities comprised of nodes of the same type. We describe here network building methods that can maximize edges between nodes of different data types leading to integrated networks. We systematically rank several network inference methods and demonstrate that, in many cases, using a random forest method, GENIE3, produces the most integrated networks. This increase in integration does not come at the cost of accuracy as GENIE3 produces networks of approximately the same quality as the other network inference methods tested here. Using GENIE3, we also infer networks representing antibody-mediated Dengue virus cell invasion and receptor-mediated Dengue virus invasion. A number of functional pathways showed centrality differences between the two networks including genes responding to both GM-CSF and IL-4, which had a higher centrality value in an antibody-mediated vs. receptor-mediated Dengue network. Because a biological system involves the interplay of many different types of molecules, incorporating multiple data types into networks will improve their use as models of biological systems. The methods explored here are some of the first to specifically highlight and address the challenges associated with how such multi-omic networks can be assembled and how the greatest number of interactions can be inferred from different data types. The resulting networks can lead to the discovery of new host response patterns and interactions during viral infection, generate new hypotheses of pathogenic mechanisms and confirm disease associated mechanisms of disease.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of the Leon3 Soft-Core Processor Within a Xilinx Radiation-Hardened Field-Programmable Gate Array

The purpose of this document is to summarize the work done to evaluate the performance of the Leon3 soft-core processor in a radiation environment while instantiated in a radiation-hardened static random-access memory based field-programmable gate array. This evaluation will look at the differences between two soft-core processors: the open-source Leon3 core and the fault-tolerant Leon3 core. Radiation testing of these two cores was conducted at the Texas A&M University Cyclotron facility and Lawrence Berkeley National Laboratory. The results of these tests are included within the report along with designs intended to improve the mitigation of the open-source Leon3. The test setup used for evaluating both versions of the Leon3 is also included within this document.

97 MATHEMATICS AND COMPUTING↗

Confidence in Numerical Simulations

This PowerPoint presentation offers a high-level discussion of uncertainty, confidence and credibility in scientific Modeling and Simulation (M&S). It begins by briefly evoking M&S trends in computational physics and engineering. The first thrust of the discussion is to emphasize that the role of M&S in decision-making is either to support reasoning by similarity or to “forecast,” that is, make predictions about the future or extrapolate to settings or environments that cannot be tested experimentally. The second thrust is to explain that M&S-aided decision-making is an exercise in uncertainty management. The three broad classes of uncertainty in computational physics and engineering are variability and randomness, numerical uncertainty and model-form uncertainty. The last part of the discussion addresses how scientists “think.” This thought process parallels the scientific method where by a hypothesis is formulated, often accompanied by simplifying assumptions, then, physical experiments and numerical simulations are performed to confirm or reject the hypothesis. “Confidence” derives, not just from the levels of training and experience of analysts, but also from the rigor with which these assessments are performed, documented and peer-reviewed.

97 MATHEMATICS AND COMPUTING↗

Computer-Based Procedures Among Older Adults: Findings from the Rancor Microworld Simulator

As with many industries worldwide, nuclear energy is experiencing an aging workforce; older than other energy sources and the national average. For example, while almost one in three nuclear industry professionals are 55+ years, for oil and gas that number is one in five. The challenges brought about by an aging workforce are one of the industry’s top concerns. However, the industry lacks for empirical research that examines the effects of developmental aging in older workers, as well as the interactions between aging and new digital technologies. We present the results of an experiment that tested three different computer-based procedures in a sample of 30 older adults (55+ years). While the industry has traditionally relied on paper-based procedures, these are being modernized by digital technology. Participants were randomly assigned to one of three procedure-types that varied by the level of digitalization, based on the IEEE Standard-1786. Type 1 essentially represents a digital representation of a paper-based procedure, Type 2 adds embedded indicators, and Type 3 adds soft controls. Participants performed two different operational scenarios (startup and loss of feedwater) on a simplified nuclear power plant simulator. Results revealed a weak signal that Type 2 may produce lower workload and lower completion times in some instances. However, there were no significant effects of procedure-type across any other outcomes, including simulator log data, situation awareness, and preference ratings. We discuss our findings in terms of optimal levels of digitalization/automation for an aging nuclear workforce and suggest pathways for future directions.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Multiple model identification of a cold flow circulating fluidized bed

Solids circulation rate is an important parameter that is essential to the control and improved performance of a circulating fluidized bed system. The present work focuses on the identification of a cold flow circulating fluidized bed using a multiple model identification technique that considers the given set-up as a nonlinear dynamic system and predicts the solids circulation rate as a function of riser aeration, move air flow rate, and total riser pressure drop. The predictor model obtained from this technique is trained on glass beads data sets in which riser aeration and move air flow are varied randomly one at a time. The global linear state space model obtained from the N4SID algorithm is trained on the same data set and the prediction results of solids circulation rate from both these algorithms are tested against data obtained at operating conditions different from the training data. The comparison between the two methods shows that the prediction results obtained from the multiple model technique are better than those obtained from the global linear model. The number of local models is increased from two to five and two third order state space models are sufficient for the present sets of data.

42 ENGINEERING↗

Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TESTING GRAVITATIONAL LENSING AS THE SOURCE OF ENHANCED STRONG Mg II ABSORPTION TOWARD GAMMA-RAY BURSTS

Sixty percent of gamma-ray bursts (GRBs) reveal strong Mg II absorbing systems, which is a factor of {approx}2 times the rate seen along lines of sight to quasars. Previous studies argue that the discrepancy in the strong Mg II covering factor is most likely to be the result of either quasars being obscured due to dust or the consequence of many GRBs being strongly gravitationally lensed. We analyze observations of quasars that show strong foreground Mg II absorption. We find that GRB lines of sight pass closer to bright galaxies than would be expected for random lines of sight within the impact parameter expected for strong Mg II absorption. While this cannot be explained by obscuration in the GRB sample, it is a natural consequence of gravitational lensing. Upon examining the particular configurations of galaxies near a sample of GRBs with strong Mg II absorption, we find several intriguing lensing candidates. Our results suggest that lensing provides a viable contribution to the observed enhancement of strong Mg II absorption along lines of sight to GRBs, and we outline the future observations required to test this hypothesis conclusively.

79 ASTRONOMY AND ASTROPHYSICS↗

ML-Based Pebble Power Reconstruction for Pebble Bed Reactor Analysis

Pebble power reconstruction has been explored to complement the conventional homogenized modeling approach in pebble bed reactor (PBR) analysis, as detailed heterogeneous geometry calculations are computationally expensive. The random distribution of pebble fuels within the core challenges the application of conventional pin power reconstruction methods. To address this, we introduce a machine learning approach based on the transformer model, composed of encoder and decoder layers, to estimate the flux and power form functions for reconstructing individual pebble neutron fluxes and powers. The homogeneous neutron flux distribution within each spectral zone (SZ) is obtained from finite element solutions of global diffusion or transport calculations. Verification tests demonstrate that the trained transformer model accurately predicts power form functions over a range of conditions, including variations in pebble enrichment, location, type, SZ size, and burnup. In particular, verification using a three-dimensional PBR benchmark with burned pebbles shows good agreement in heterogeneous pebble power distributions between Griffin and Serpent. These results highlight the potential of applying conventional pin power reconstruction approaches to PBR cores with randomly distributed pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancing carbon and nitrogen sequestration in reclaimed soils through organic amendments and chiseling

The choice of reclamation techniques could affect restoration success, ecosystem productivity, and the capacity of reclaimed mine soil (RMS) to sequester soil organic carbon (SOC). A field experiment was conducted at three reclaimed coal mine sites across eastern Ohio to assess the impact of several reclamation techniques on biomass production, soil properties, and temporal changes in SOC and N pools. Amendments and reclamation practices tested were: normal reclamation practice (NRP, control), cow (Bos taurus) manure (10 Mg ha{sup -1}), mulching with oat straw (15 Mg hat), and chiseling (30-cm depth). At each site, all treatments were applied in triplicate to experimental plots in accord with a randomized complete block design. After 5 yr of restoration, results showed no effect of mulching on any of the soil properties investigated but significant effects of manuring and chiseling. During that period, SOC sequestration rates ranged between 0.6 and 2.8 Mg C ha{sup -1} yr{sup -1}, with the highest rates recorded in the manure-treated plots. Aboveground biomass production, biomass N content, and soil N and SOC pools were also significantly higher in the manure and chiseling treatments, probably due to greater exploration of the soil volume by plant roots and more efficient uptake of water and available nutrients. Ecosystem C (SOC + biomass C) in these two treatments also exceeded that in the NRP by 25 to 27 Mg C ha{sup -}. Thus, manure application and chiseling are effective reclamation practices for restoring RMS.

01 COAL, LIGNITE, AND PEAT↗

Gray and multigroup radiation transport through 3D binary stochastic media with different sphere radii distributions

Here, gray and multigroup radiation is transported through 3D media consisting of spheres randomly placed in a uniform background. Comparisons are made between using constant radii spheres and three different distributions of sphere radii. Because of the computational cost of 3D calculations, only the lowest angle order, n=1, is tested. If the mean chord length is held constant, using different radii distributions makes little difference. This is true for both gray and multigroup solutions. 3D transport solutions are compared to 2D and 1D solutions with the same mean chord lengths. 2D disk and 3D sphere media give solutions that are nearly identical while 1D slab solutions are fundamentally different.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine learning predictions of high-Curie-temperature materials

Technologies that function at room temperature often require magnets with a high Curie temperature, $T$ C , and can be improved with better materials. Discovering magnetic materials with a substantial $T$ C is challenging because of the large number of candidates and the cost of fabricating and testing them. Using the two largest known datasets of experimental Curie temperatures, we develop machine-learning models to make rapid $T$ C predictions solely based on the chemical composition of a material. We train a random-forest model and a k -NN one and predict on an initial dataset of over 2500 materials and then validate the model on a new dataset containing over 3000 entries. The accuracy is compared for multiple compounds' representations (“descriptors”) and regression approaches. A random-forest model provides the most accurate predictions and is not improved by dimensionality reduction or by using more complex descriptors based on atomic properties. Further, a random-forest model trained on a combination of both datasets shows that cobalt-rich and iron-rich materials have the highest Curie temperatures for all binary and ternary compounds. An analysis of the model reveals systematic error that causes the model to over-predict low-$T$ C materials and under-predict high-$T$ C materials. For exhaustive searches to find new high-$T$ C materials, analysis of the learning rate suggests either that much more data is needed or that more efficient descriptors are necessary.

36 MATERIALS SCIENCE↗

STAR-GALAXY CLASSIFICATION IN MULTI-BAND OPTICAL IMAGING

Ground-based optical surveys such as PanSTARRS, DES, and LSST will produce large catalogs to limiting magnitudes of r {approx}> 24. Star-galaxy separation poses a major challenge to such surveys because galaxies-even very compact galaxies-outnumber halo stars at these depths. We investigate photometric classification techniques on stars and galaxies with intrinsic FWHM <0.2 arcsec. We consider unsupervised spectral energy distribution template fitting and supervised, data-driven support vector machines (SVMs). For template fitting, we use a maximum likelihood (ML) method and a new hierarchical Bayesian (HB) method, which learns the prior distribution of template probabilities from the data. SVM requires training data to classify unknown sources; ML and HB do not. We consider (1) a best-case scenario (SVM{sub best}) where the training data are (unrealistically) a random sampling of the data in both signal-to-noise and demographics and (2) a more realistic scenario where training is done on higher signal-to-noise data (SVM{sub real}) at brighter apparent magnitudes. Testing with COSMOS ugriz data, we find that HB outperforms ML, delivering {approx}80% completeness, with purity of {approx}60%-90% for both stars and galaxies. We find that no algorithm delivers perfect performance and that studies of metal-poor main-sequence turnoff stars may be challenged by poor star-galaxy separation. Using the Receiver Operating Characteristic curve, we find a best-to-worst ranking of SVM{sub best}, HB, ML, and SVM{sub real}. We conclude, therefore, that a well-trained SVM will outperform template-fitting methods. However, a normally trained SVM performs worse. Thus, HB template fitting may prove to be the optimal classification method in future surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparing three generations of D-Wave quantum annealers for minor embedded combinatorial optimization problems

Abstract Quantum annealing (QA) is a novel type of analog computation that aims to use quantum mechanical fluctuations to search for optimal solutions of Ising problems. QA in the transverse Ising model, implemented on D-Wave quantum processing units, are available as cloud computing resources. In this study we report concise benchmarks across three generations of D-Wave quantum annealers, consisting of four different devices, for the NP-hard discrete combinatorial optimization problems unweighted maximum clique and unweighted maximum cut on random graphs. The Ising, or equivalently quadratic unconstrained binary optimization, formulation of these problems do not require auxiliary variables for order reduction, and their overall structure and weights are not highly variable, which makes these problems simple test cases to understand the sampling capability of current D-Wave quantum annealers. All-to-all minor embeddings of size 52, with relatively uniform chain lengths, are used for a direct comparison across the Chimera, Pegasus, and Zephyr device topologies. A grid-search over annealing times and the minor embedding chain strengths is performed in order to determine the level of reasonable performance for each device and problem type. Experiment metrics that are reported are approximation ratios for non-broken chain samples, chain break proportions, and time-to-solution for the maximum clique problem instances. How fairly the quantum annealers sample optimal maximum cliques, for instances which contain multiple maximum cliques, is quantified using entropy of the measured ground state distributions. The newest generation of quantum annealing hardware, which has a Zephyr hardware connectivity, performed the best overall with respect to approximation ratios and chain break frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗