Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “proof”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Construction of an in vitro primary lung co-culture platform derived from New Zealand white rabbits

We report the construction of an in vitro three dimensional (3D) co-culture platform consisting of differentiated lung epithelial cells and monocytes from New Zealand white rabbits. Rabbit lung epithelial cells were successfully grown at air-liquid interface, produced mucus, and expressed both sialic acid alpha-2,3 and alpha-2,6. Blood-derived CD14+ monocytes were deposited above the epithelial layer resulting in the differentiation of a subset of monocytes into CD11c+ cells within the co-culture. These proof-of-concept findings provide a convenient means to comparatively study in vitro versus in vivo rabbit lung responses as they relate to inhalation or lung-challenge studies.

lung↗

Design, Development and Testing of Inconel Alloy IN718 Spherical Gas Bottle for Oxygen Storage

This paper describes the details of design, manufacture and testing of 200 mm diameter spherical gas bottle of Inconel 718 (IN718) with nominal wall thickness of 2.3 mm. Gas bottle was designed for the specified internal pressure loading with a thickness of 2.9 mm at the circumferential weld which was brought down to 2.3 mm at the membrane locations. Hemispherical forgings produced through closed-die hammer forging were machined and electron beam welded to produce a spherical gas bottle. Duly welded gas bottle was subjected to standard aging treatment to achieve the required tensile strength. Aged gas bottle was inspected for dimensions and other stringent quality requirements using various nondestructive testing techniques. After inspection, gas bottle was subjected to pressure test for maximum expected operating pressure and proof pressure of 25 and 37.5 MPa, respectively. Strain gauges were bonded at different locations on the gas bottle to monitor the strains during the pressure test and correlated with the predicted values. The predicted strain matched well with the experimental strain confirming the design and structural integrity.

36 MATERIALS SCIENCE↗

Problem of Identification of Phase Transformation Models Used in Simulations of Steels Processing

Accuracy of phase transformation models depends on the correctness of coefficients evaluation, adequate to the investigated material. Dilatometric tests combined with the inverse analysis are used to perform identification. Since the problem is nonlinear, analytical approach is not possible and the inverse solution is transferred into the optimization task. It leads to difficulties typical for optimization of multivariable function such as local minima and lack of proof of the uniqueness. The problem of the effectiveness and uniqueness of the inverse algorithms used for identification of phase transformation models for steels was investigated for two models. The first was a modified JMAK (Johnson–Mehl–Avrami–Kolmogorov) equation. The second was an upgrade of the Leblond equation, in which second-order derivative of the volume fraction with respect to time was introduced. In classical identification, the result for one transformation depends on the coefficients for the remaining transformations and optimization has to be performed several times until the compatibility between transformations is reached. To avoid encountered problems, complex optimization simultaneously for all coefficients in the models was performed. This approach was based on nature-inspired optimization techniques. Models with identified coefficients for various steels were validated in simulations of industrial processes of laminar cooling and continuous annealing of strips.

36 MATERIALS SCIENCE↗

Photo-controlled release of paclitaxel and model drugs from RNA pyramids

Stimuli-responsive release of drugs from a nanocarrier in spatial-, temporal-, and dosage-controlled fashions is of great interest in the pharmaceutical industry. Paclitaxel is one of the most effective and popular chemotherapeutic drugs against a number of cancers such as metastatic or nonmetastatic breast cancer, non–small cell lung cancer, refractory ovarian cancer, AIDS-related Kaposi’s sarcoma, and head and neck cancers. Here, by taking the advantage of RNA nanotechnology in biomedical and material science, we developed a three-dimensional pyramid-shaped RNA nanocage for a photocontrolled release of cargo, using paclitaxel as a model drug. The light-triggered release of paclitaxel or fluorophore Cy5 was achieved by incorporation of photocleavable spacers into the RNA nanoparticles. Upon irradiation with ultraviolet light, cargos were rapidly released (within 5 min). In vitro treatment of breast cancer cells with the RNA nanoparticles harboring photocleavable paclitaxel showed higher cytotoxicity as compared to RNA nanoparticles without the photocleavable spacer. The methodology provides proof of concept for the application of the light-triggered controlled release of drugs from RNA nanocages.

59 BASIC BIOLOGICAL SCIENCES↗

A novel battery scheme: Coupling nanostructured phosphorus anodes with lithium sulfide cathodes

Lithium-ion batteries are approaching their theoretical limit and can no longer keep up with the increasing demands of human society. Lithium-sulfur batteries, with a high theoretical specific energy, are promising candidates for next generation energy storage. However, the use of Li metal in Li-S batteries compromises both safety and performance, enabling dendrite formation and causing fast capacity degradation. Previous studies have probed alternative battery systems to replace the metallic Li in Li-S system, such as a Si/Li2S couple, with limited success in performance. Recently, there is a focus on red P as a favorable anode material to host Li. In this work, we establish a novel battery scheme by utilizing a P/C nanocomposite anode and pairing it with a Li 2 S coated carbon nanofiber cathode. We find that red P anode can be compatible in ether-based electrolyte systems and can be successfully coupled to a Li 2 S cathode. Our proof of concept full-cell displays remarkable specific capacity, rate and cycling performances. We expect our work will provide a useful alternative system and valuable insight in the quest for next generation energy storage devices.

25 ENERGY STORAGE↗

Correction to: No need for frame-wise attenuation correction in dynamic Rubidium-82 PET for myocardial blood flow quantification

Due to the typesetter not carrying out the author’s corrections at proof stage, there are two errors in the published article: where “mL × min × g” appears, it should be “mL/min/g”. One error is in the Figure 3 caption, and one error is in the second sentence under the heading “MBF Quantification”. The original article has been corrected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source

A liquid sampling-atmospheric pressure afterglow microplasma ionization (LS-APAG) source is presented for the first time, which is embedded with both electrospray ionization (ESI) and atmospheric pressure afterglow microplasma ionization (APAG) techniques. This ion source is capable of analyzing compounds with diverse molecule weights and polarities. An unseparated mixture sample was detected as a proof-of-concept, giving complementary information (both polarities and non-polarities) with the two ionization modes. It should also be noted that molecular mass can be quickly identified by ESI with clean and simple spectra, while the structure can be directly studied using APAG with in-source oxidation. The ionization/oxidation mechanism and applications of the LS-APAG source have been further explored in the analysis of nonpolar alkanes and unsaturated fatty acids/esters. A unique [M + O – 3H]{sup +} was observed in the case of individual alkanes (C{sub 5}–C{sub 19}) and complex hydrocarbons mixture under optimized conditions. Moreover, branched alkanes generated significant in-source fragments, which could be further applied to the discrimination of isomeric alkanes. The technique also facilitates facile determination of double bond positions in unsaturated fatty acids/esters due to diagnostic fragments (the acid/ester-containing aldehyde and acid oxidation products) generated by on-line ozonolysis in APAG mode. Finally, some examples of in situ APAG analysis by gas sampling and surface sampling were given as well. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ambient Ionization Mass Spectrometry Measurement of Aminotransferase Activity

A change in enzyme activity has been used as a clinical biomarker for diagnosis and is useful in evaluating patient prognosis. Current laboratory measurements of enzyme activity involve multi-step derivatization of the reaction products followed by quantitative analysis of these derivatives. This study simplified the reaction systems by using only the target enzymatic reaction and directly detecting its product. A protocol using paper spray mass spectrometry for identifying and quantifying the reaction product has been developed. Evaluation of the activity of aspartate aminotransferase (AST) was chosen as a proof-of-principle. The volume of sample needed is greatly reduced compared with the traditional method. Paper spray has a desalting effect that avoids sprayer clogging problems seen when examining serum samples by nanoESI. This very simple method does not require sample pretreatment and additional derivatization reactions, yet it gives high quality kinetic data, excellent limits of detection (60 ppb from serum), and coefficients of variation <10% in quantitation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable Isotope Labeling for Improved Comparative Analysis of RNA Digests by Mass Spectrometry

Even with the advent of high throughput methods to detect modified ribonucleic acids (RNAs), mass spectrometry remains a reliable method to detect, characterize, and place post-transcriptional modifications within an RNA sequence. Here we have developed a stable isotope labeling comparative analysis of RNA digests (SIL-CARD) approach, which improves upon the original {sup 18}O/{sup 16}O labeling CARD method. Like the original, SIL-CARD allows sequence or modification information from a previously uncharacterized in vivo RNA sample to be obtained by direct comparison with a reference RNA, the sequence of which is known. This reference is in vitro transcribed using a {sup 13}C/{sup 15}N isotopically enriched nucleoside triphosphate (NTP). The two RNAs are digested with an endonuclease, the specificity of which matches the labeled NTP used for transcription. As proof of concept, several transfer RNAs (tRNAs) were characterized by SIL-CARD, where labeled guanosine triphosphate was used for the reference in vitro transcription. RNase T1 digestion products from the in vitro transcript will be 15 Da higher in mass than the same digestion products from the in vivo tRNA that are unmodified, leading to a doublet in the mass spectrum. Singlets, rather than doublets, arise if a sequence variation or a post-transcriptional modification is present that results in a relative mass shift different from 15 Da. Moreover, the use of the in vitro synthesized tRNA transcript allows for quantitative measurement of RNA abundance. Overall, SIL-CARD simplifies data analysis and enhances quantitative RNA modification mapping by mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Morphological and Morphometric Analysis of Mass Spectrometry Imaging Data: Application to Biomarker Discovery

Mass spectrometry imaging datasets are mostly analyzed in terms of average intensity in regions of interest. However, biological tissues have different morphologies with several sizes, shapes, and structures. The important biological information, contained in this highly heterogeneous cellular organization, could be hidden by analyzing the average intensities. Finding an analytical process of morphology would help to find such information, describe tissue model, and support identification of biomarkers. This study describes an informatics approach for the extraction and identification of mass spectrometry image features and its application to sample analysis and modeling. For the proof of concept, two different tissue types (healthy kidney and CT-26 xenograft tumor tissues) were imaged and analyzed. A mouse kidney model and tumor model were generated using morphometric – number of objects and total surface – information. The morphometric information was used to identify m/z that have a heterogeneous distribution. It seems to be a worthwhile pursuit as clonal heterogeneity in a tumor is of clinical relevance. This study provides a new approach to find biomarker or support tissue classification with more information. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stimulated Motion Suppression (STMS): a New Approach to Break the Resolution Barrier for Ion Trap Mass Spectrometry

Ion trap is an excellent platform to perform tandem mass spectrometry (MS/MS), but has an intrinsic drawback in resolving power. Using ion resonant ejection as an example, the resolution degradation can be largely attributed to the broadening of the resonant frequency band (RFB) between ion motion and driving alternative-current (AC). To solve this problem, stimulated motion suppression (STMS) was developed. The key idea of STMS is the use of two suppression alternative-current (SAC) signals, which both have reversed initial phases to the main AC. The SACs can block the unexpected sideband ion resonances (or ejections), therefore playing a key role in sharpening the RFB. The proof-of-concept has been demonstrated through ion trajectory simulations and validated experimentally. STMS provides a new and versatile means for the improvement of the ion trap resolution, which for a long time has reached the bottleneck through conventional methods, e.g., increasing the radio-frequency (RF) voltage and decreasing the mass scan rate. At the end, it is worth noting that the idea of STMS is very general and principally can be applied in any RF device for the purposes of high-resolution mass analysis and ion isolation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental Studies on Poly(2-oxazoline) Side Chain Isomers Using Tandem Mass Spectrometry and Ion Mobility-Mass Spectrometry

When polymer mixtures become increasingly complex, the conventional analysis techniques become insufficient for complete characterization. Mass spectrometric techniques can satisfy this increasing demand for detailed sample characterization. Even though isobaric polymers are indistinguishable using simple mass spectrometry (MS) analyses, more advanced techniques such as tandem MS (MS/MS) or ion mobility (IM) can be used. Here, we report proof of concept for characterizing isomeric polymers, namely poly(2-n-propyl-2-oxazoline) (Pn-PrOx) and poly(2-isopropyl-2-oxazoline) (Pi-PrOx), using MS/MS and IM-MS. Pi-PrOx ions lose in intensity at higher accelerating voltages than Pn-PrOx ions during collision-induced dissociation (CID) MS/MS experiments. A Pn/i-PrOx mixture could also be titrated using survival yield calculations of either precursor ions or cation ejection species. IM-MS yielded shape differences in the degree of polymerization (DP) regions showing the structural rearrangements. Combined MS techniques are thus able to identify and deconvolute the molar mass distributions of the two isomers in a mixture. Finally, the MS/MS and IM-MS behaviors are compared for interpretation. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of Gas-Phase Ion Mobility Coefficients Using Voltage Sweep Multiplexing

In a standard single averaged, drift tube ion mobility spectrometry (IMS) experiment, typically less than 1% of the ions are utilized, with the rest of the ions neutralizing on a closed ion gate or ion optic element. Though some efforts at lower pressures (e.g., 4 Torr) have been made to address this issue by concentrating ions prior to release into a drift cell, the ion current reaching the detector during an IMS experiment is often diminished due to this lower duty cycle. Additionally, when considering the temporal nature of the drift tube IMS experiment and the trajectory of IMS towards higher resolution separations and lower duty cycles, increased detector sampling rates are another factor also which further necessitates new modes of conducting the IMS experiment. Placing this trend in context with ion mobility-mass spectrometry instruments (IM-MS), there are numerous types of mass spectrometers that are simply incompatible with the single averaged ion mobility spectrometry experiments due to timing incompatibilities (i.e., ion traps are an order of magnitude slower than the IMS experiment). However, by utilizing a dual gate ion mobility spectrometer for ion multiplexing, ion utilization efficiency can be significantly increased while creating a measurement signal that can be recorded at low sampling rates. In this work, we present the fundamental theory and first results from proof-of-concept measurements using a new type of ion multiplexing that relies on changing the electric field within the drift cell during the course of an experiment while simultaneously opening the ion gates at a constant frequency. For brevity, this mode is termed voltage sweep multiplexing (VSM). Key variables for this type of experiment are discussed and verified with measurements from traditional signal averaged experiments. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the convergence and convergence order of finite volume gradient schemes for oblique derivative boundary value problems

This work is an improvement of the previous note (Bradji in: Fuhrmann et al., Finite volumes for complex applications VII–methods, theoretical aspects. Proceedings of the FVCA 7, Berlin, 2014) which dealt with the convergence analysis of a finite volume scheme for the Poisson’s equation with a linear oblique derivative boundary condition. The formulation of the finite volume scheme given in Bradji (in: Fuhrmann et al., Finite volumes for complex applications VII–methods, theoretical aspects. Proceedings of the FVCA 7, Berlin, 2014) involves the discrete gradient introduced recently in Eymard et al. (IMA J Numer Anal 30(4):1009–1043, 2010). In this paper, we consider the convergence analysis of finite volume schemes involving the discrete gradient of Eymard et al. (IMA J Numer Anal 30(4):1009–1043, 2010) for elliptic and parabolic equations with linear oblique derivative boundary conditions. Linear oblique derivative boundary conditions arise for instance in the study of the motion of water in a canal, cf. Lesnic (Commun Numer Methods Eng 23(12):1071–1080, 2007). We derive error estimates in several norms which allow us to get error estimates for the approximations of the exact solutions and its first derivatives. In particular, we provide an error estimate between the gradient of the exact solutions and the discrete gradient of the approximate solutions. Convergence of the family of finite volume approximate solutions towards the exact solution under weak regularity assumption is also investigated. In the case of parabolic equations with oblique derivative boundary conditions, we develop a new discrete a priori estimate result. The proof of this result is based on the use of a discrete mean Poincaré–Wirtinger inequality. Thanks to the stated a priori estimate and to a comparison with an appropriately chosen auxiliary finite volume scheme, we derive the convergence results. This work can be viewed as a continuation of the previous work (Bradji and Gallouët in Int J Finite Vol 3(2):1–35, 2006) where a convergence analysis for a finite volume scheme, based on the admissible mesh of Eymard et al. (In: Ciarlet and Lions, Handbook of numerical analysis, North-Holland, Amsterdam, 2000), for the Poisson’s equation with a linear oblique derivative boundary conditions is given. The obtained convergence results do not require any relation between the mesh sizes of the spatial and time discretizations. Some numerical tests are presented for both elliptic and parabolic equations. In particular, we present three methods to compute the discrete solution.

97 MATHEMATICS AND COMPUTING↗

H{sub ∞} memory feedback control for uncertain singular Markov jump systems with time-varying delay and input saturation

This paper concerns with the H{sub ∞} robust exponential stability and memory state feedback stabilization of singular Markov jump systems with time-delay and input saturation. Linear matrix inequality conditions are given to guarantee regularity, impulse-freeness and exponential stability for the singular Markov jump system. Moreover, sufficient conditions are presented to ensure the H{sub ∞} disturbance attenuation level, and the design method of memory feedback controller is developed by solving linear matrix inequalities optimization problem without any decompositions of system matrices and equivalent transformation. Furthermore, the function in the proof procedure belongs to multiple Lyapunov-like functions whose advantage lies in their flexibility. Finally, numerical examples are employed to verify the effectiveness of the proposed methods and to illustrate the significant improvement on the conservativeness of some reported results in the literature.

97 MATHEMATICS AND COMPUTING↗

Combining 3D printing of copper current collectors and electrophoretic deposition of electrode materials for structural lithium-ion batteries

Serving as a proof of concept, additive manufacturing and electrophoretic deposition are leveraged in this work to enable structural lithium-ion batteries with load-bearing and energy storage dual functionality. The preparation steps of a complex 3D printed copper current collector, involving the formulation of a photocurable resin formulation, as well as the vat photopolymerization process followed by a precursors-based solution soaking step and thermal post-processing are presented. Compression and microhardness testing onto the resulting 3D printed copper current collector are shown to demonstrate adequate mechanical performance. Electrophoretic deposition of graphite as a negative electrode active material and other additives was then performed onto the 3D printed copper collector, with the intention to demonstrate energy storage functionality. Half-cell electrochemical cycling of the 3D multi-material current collector/negative electrode versus lithium metal finally demonstrates that structural battery components can be successfully obtained through this approach.

25 ENERGY STORAGE↗

An Improved Sub-component Fatigue Testing Method for Material Characterization

In this paper an improved sub-component fatigue testing method is proposed, in which structural optimization is used to obtain specimens in which fatigue failure is precipitated in the designated area away from the boundaries, i.e., load application and fixture points. This is achieved by optimizing the nonlinear beam taper and the dynamic excitation. The major requirement for accurate material characterization through sub-component tests concerns unbiased stress states in the gauge section. However, empiricism shows that many sub-component high-cycle fatigue testing methods suffer from failure in the boundaries rather than the gauge section, which causes bias. The common practice for reinforcing those regions only shifts the issue into new areas of local discontinuities where failure is still caused remotely from the gauge section. An experimental proof of concept demonstrates that optimization of the beam taper can be used to obtain unbiased fatigue test data.

42 ENGINEERING↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗