Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “panel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

In silico identification of key genes and signaling pathways targeted by a panel of signature microRNAs in prostate cancer

Accumulating evidence have suggested that some microRNAs are aberrantly expressed in prostate cancer. In our previous work, we had identified a panel of four differentially expressed microRNAs in prostate cancer. In the present study, we have investigated common molecular targets of this panel of miRNAs (DEMs) and key hub genes that can serve as potential candidate biomarkers in the pathogenesis and progression of prostate cancer. A joint bioinformatics approach was employed to identify differentially expressed genes (DEGs) in prostate cancer. Gene enrichment analysis followed by the protein–protein interaction (PPI) network construction and selection of hub genes was further performed using String and Cytoscape, respectively. Gene ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analysis of the identified hub genes was conducted using the Database for Annotation, Visualization and Integrated Discovery (DAVID) tool. In total, 496 genes were identified to be common targets of DEMs in prostate cancer and 13 key hub genes were identified from three modules of the PPI network of the DEGs. Further top five genes viz Rhoa, PI3KCA, CDC42, MAPK3, TP53 were used for Enrichment analysis which revealed their association with vital cellular and functional pathways in prostate cancer indicating their potential as candidate biomarkers in prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness of a genetic test panel designed for gynecological cancer: an exploratory study

To increase diagnostic efficiency and cost-effectiveness, we performed an exploratory genetic test using a newly designed panel containing 28 actionable and druggable genes, alterations in which are frequently reported in gynecological cancers (TANRE-G, Targeted variants ANalysis RElated to Gynecological cancers). Samples consisted of the formalin-fixed, paraffin-embedded tissue of endometrial (4 cases), cervical (3 cases), and ovarian (4 cases) carcinomas. The sequencing procedure was performed using Ion PGM in our institute with related sequencing kits, and data were analyzed using ClinVar. The present system achieved more than 2500 reads in all tumor samples, and enabled a copy number variation analysis. Results showed that actionable and druggable mutations were detected in 82% (9/11) and 64% (7/11) of cases, respectively, which was similar to other commercially available genetic tests. The amplification of MYC and KRAS was also detected. The analysis cost for each sample was JPY 94,000 (USD 850). These results demonstrate the potential of the TANRE-G panel as an effective tool for examining genetic alterations in gynecological cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Macro-level mechanical interlocking: A rapid joining approach for additively manufactured compression molded composite panels

Composite joining typically involves multiple steps, such as drilling and surface treatment, as part of the manufacturing process, which leads to low throughput and long cycle times. In the present study, we demonstrated a macro-level mechanical interlocking (MI) based, rapid joining technique to assemble additively manufactured compression molded (AMCM) panels, enabling the production of parts larger than the mold dimensions. Composite panels made of 20 wt% short carbon fiber reinforced acrylonitrile butadiene styrene (CF/ABS) were joined using MI features of various geometries, namely tree (TR), dovetail (Dov), rectangle 2 (Rect2), and rectangle 1 (Rect1), and their in-plane strength was evaluated. The resultant strength of the tested MI joints reached up to 74 % of the baseline tensile strength (i.e., the ‘no joint’ case). Observations from optical and scanning electron microscopy revealed inadequate polymer diffusion between the adherends, indicating that the joint strength was primarily derived from mechanical interlocking. Additionally, the fracture surfaces exhibited stress-whitening marks, which were characterized using differential scanning calorimetry (DSC). The increase in melting enthalpy suggested local stretching of polymer chains due to MI. Finite element analysis (FEA) indicated that the Rect1 MI feature, which generated the lowest stress concentration, outperformed the others in terms of joint strength, achieving 42 MPa. As a demonstration of the MI joining method, a battery box tray measuring 108 cm × 34 cm using a mold with an effective dimension of 36 cm × 34 cm successfully manufactured, resulting in a part with an area three times larger than the mold. In conclusion, this study presents a promising approach to improving composite joining techniques while minimizing production complexities.

In-plane joining↗

ACR Appropriateness Criteria on Induction and Adjuvant Therapy for Stage N2 Non-Small-Cell Lung Cancer: Expert Panel on Radiation Oncology-Lung

'The American College of Radiology seeks and encourages collaboration with other organizations on the development of the ACR Appropriateness Criteria through society representation on expert panels. Participation by representatives from collaborating societies on the expert panel does not necessarily imply society endorsement of the final document.'

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of coring procedures applied to Si, CdTe, and CIGS solar panels

Most of the research on the performance and degradation of photovoltaic modules is based on macroscale measurements of device parameters such as efficiency, fill factor, open-circuit voltage, and short-circuit current. Our goal is to develop the capabilities to allow us to study the degradation of these parameters in the micro- and nanometer scale and to relate our results to performance parameters. To achieve this objective, the first step is to be able to access small samples from specific areas of the solar panels without changing the properties of the material. In this paper, we describe two coring procedures that we developed and applied to Si, CIGS, and CdTe solar panels. In the first procedure, we cored full samples, whereas in the second we performed a partial coring that keeps the tempered glass intact. The cored samples were analyzed by different analytical techniques before and after coring, at the same locations, and no damage during the coring procedure was observed.

14 SOLAR ENERGY↗

Recovery of indium from used LCD panel by a time efficient and environmentally sound method assisted HEBM

Highlights: ► In this study, we recovered indium from a waste LCD panel. ► The ITO glass was milled to obtain micron size particles in a HEBM machine. ► Effect of particle size of ITO glass on the amount of dissolved In was investigated. ► In a very short time, a considerable amount of In was recovered. ► Amount of HCl in acid solution was decreased to 40 vol.%. - Abstract: In this study, a method which is environmentally sound, time and energy efficient has been used for recovery of indium from used liquid crystal display (LCD) panels. In this method, indium tin oxide (ITO) glass was crushed to micron size particles in seconds via high energy ball milling (HEBM). The parameters affecting the amount of dissolved indium such as milling time, particle size, effect time of acid solution, amount of HCl in the acid solution were tried to be optimized. The results show that by crushing ITO glass to micron size particles by HEBM, it is possible to extract higher amount of indium at room temperature than that by conventional methods using only conventional shredding machines. In this study, 86% of indium which exists in raw materials was recovered about in a very short time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of solar panels on global climate

Regardless of the harmful effects of burning fossil fuels on global climate1,2, other energy sources will become more important in the future because fossil fuels could run out by the early twenty-second century3 given the present rate of consumption4. This implies that sooner or later humanity will rely heavily on renewable energy sources. Here we model the effects of an idealized large-scale application of renewable energy on global and regional climate relative to a background climate of the representative concentration pathway 2.6 scenario (RCP2.6; ref. 5). We find that solar panels alone induce regional cooling by converting incoming solar energy to electricity in comparison to the climate without solar panels. The conversion of this electricity to heat, primarily in urban areas, increases regional and global temperatures which compensate the cooling effect. However, there are consequences involved with these processes that modulate the global atmospheric circulation, resulting in changes in regional precipitation.

Environmental Sciences & Ecology↗

A thousand-genome panel retraces the global spread and adaptation of a major fungal crop pathogen

Human activity impacts the evolutionary trajectories of many species worldwide. Global trade of agricultural goods contributes to the dispersal of pathogens reshaping their genetic makeup and providing opportunities for virulence gains. Understanding how pathogens surmount control strategies and cope with new climates is crucial to predicting the future impact of crop pathogens. Here, we address this by assembling a global thousand-genome panel of Zymoseptoria tritici, a major fungal pathogen of wheat reported in all production areas worldwide. We identify the global invasion routes and ongoing genetic exchange of the pathogen among wheat-growing regions. We find that the global expansion was accompanied by increased activity of transposable elements and weakened genomic defenses. Finally, we find significant standing variation for adaptation to new climates encountered during the global spread. Our work shows how large population genomic panels enable deep insights into the evolutionary trajectory of a major crop pathogen.

59 BASIC BIOLOGICAL SCIENCES↗

RC structures strengthened by metal shear panels: experimental and numerical analysis

Metal shear panels (MSPs) may be effectively used as a lateral load resisting system for framed structures. In the present paper, such a technique is applied for the seismic protection of existing RC buildings, by setting up a specific design procedure, which has been developed on the basis of preliminary full-scale experimental tests. The obtained results allowed the development of both simplified and advanced numerical models of both the upgraded structure and the applied shear panels. Also, the proposed design methodology, which is framed in the performance base design philosophy, has been implemented for the structural upgrading of a real Greek existing multi-storey RC building. The results of the numerical analysis confirmed the effectiveness of the proposed technique, also emphasising the efficiency of the implemented design methodology.

58 GEOSCIENCES↗

Panel discussion: What don't we know about confinement?

The participants in this discussion session of the QCHS 9 meeting were each asked the following question: ''What would be the most useful piece of information that you could obtain, by whatever means, that would advance your own program, and/or our general understanding of confinement?'' This proceedings contains a brief summary of each panel member's contribution to the discussion, provided by the panel members themselves.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mechanism of high luminous efficacy in plasma display panel with high secondary electron emission coefficient cathode material analyzed through three-dimensional fluid model simulation

The mechanism to realize high luminous efficacy in a plasma display panel fabricated with a cathode material possessing a high secondary electron emission coefficient ({gamma}) for Ne and Xe ions was studied via three-dimensional numerical simulation. When a high {gamma} cathode material is used, the increased electron heating efficacy is responsible for increasing vacuum ultraviolet (VUV) efficacy with 10% Xe content gas. However, the continued availability of sufficient secondary electrons during the dynamic moving phase of the cathode sheath in which the electric field remains weakened causes increasing VUV efficacy with 30% Xe content gas. It was found that the improvement of the luminous efficacy of the plasma display panel with a high {gamma} cathode material is maximized under the condition of high Xe content gas because of the simultaneous increase of the electron heating efficacy and Xe excitation efficacy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nitrogen incorporated ultrananocrystalline diamond based field emitter array for a flat-panel x-ray source

A field emission based flat-panel transmission x-ray source is being developed as an alternative for medical and industrial imaging. A field emitter array (FEA) prototype based on nitrogen incorporated ultrananocrystalline diamond film has been fabricated to be used as the electron source of this flat panel x-ray source. The FEA prototype was developed using conventional microfabrication techniques. The field emission characteristics of the FEA prototype were evaluated. Results indicated that emission current densities of the order of 6 mA/cm{sup 2} could be obtained at electric fields as low as 10 V/μm to 20 V/μm. During the prototype microfabrication process, issues such as delamination of the extraction gate and poor etching of the SiO{sub 2} insulating layer located between the emitters and the extraction layer were encountered. Consequently, alternative FEA designs were investigated. Experimental and simulation data from the first FEA prototype were compared and the results were used to evaluate the performance of alternative single and double gate designs that would yield better field emission characteristics compared to the first FEA prototype. The best simulation results are obtained for the double gate FEA design, when the diameter of the collimator gate is around 2.6 times the diameter of the extraction gate.

07 ISOTOPE AND RADIATION SOURCES↗

Transmission type flat-panel X-ray source using ZnO nanowire field emitters

A transmission type flat-panel X-ray source in diode structure was fabricated. Large-scale patterned ZnO nanowires grown on a glass substrate by thermal oxidation were utilized as field emitters, and tungsten thin film coated on silica glass was used as the transmission anode. Uniform distribution of X-ray generation was achieved, which benefited from the uniform electron emission from ZnO nanowires. Self-ballasting effect induced by the intrinsic resistance of ZnO nanowire and decreasing of screening effect caused by patterned emitters account for the uniform emission. Characteristic X-ray peaks of W-L lines and bremsstrahlung X-rays have been observed under anode voltages at a range of 18–20 kV, the latter of which were the dominant X-ray signals. High-resolution X-ray images with spatial resolution less than 25 μm were obtained by the flat-panel X-ray source. The high resolution was attributed to the small divergence angle of the emitted X-rays from the transmission X-ray source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electroluminescence Analysis and Grading of Hail Damaged Solar Panels

We analyzed more than 4000 electroluminescence images of hail damaged solar panels from a cluster of houses in Texas. We enhanced the images for ease of analysis and classified the defects within each solar cell into categories of glass breakage, installer damage, inactive substrings, crack severity, interconnect wire problems, and whether the damage was likely caused by hail. From these statistics, we quantified each panel into five levels of hail damage for insurance claims, and four levels of overall quality for potential resale pricing. Here, we share here some statistics regarding the defects with the hope that the data is useful to others attempting to predict the invisible damage to systems based just on the easily observable glass breakage statistics.

14 SOLAR ENERGY↗

Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl

Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal and noise transfer properties of CsI:Tl phosphors. Three different CsI:Tl phosphors from two different vendors have been used to produce three system configurations. The performance of each system configuration has been studied in terms of the modulation transfer function (MTF), noise power spectra, and detective quantum efficiency (DQE) in the mammographic energy range. A simple method to determine quantum limited systems in this energy range is also presented. In addition, with aid of monochromatic synchrotron radiation, the effect of iodine characteristic x-rays of the CsI:Tl on the MTF has been determined. A Monte Carlo simulation of the signal transfer properties of the imager is also presented in order to study the stages that degrade the spatial resolution of our current system. The effect of using substrate patterning during the growth of CsI:Tl columnar structure was also studied, along with the effect of CsI:Tl fixed pattern noise due to local variations in the scintillation light. CsI:Tl fixed pattern noise appears to limit the performance of our current system configurations. All the system configurations are quantum limited at 0.23 {mu}C/kg with two of them having DQE (0) equal to 0.57. Active pixel flat panel imagers are shown to be digital x-ray imagers with almost constant DQE throughout a significant part of their dynamic range and in particular at very low exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors

Purpose: The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. Methods: The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 {mu}Gy air KERMA) to the detector. Results: The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r{sup 2} = 0.9999). The dependence was greater than unity (m = 1.101 {+-} 0.006), and the difference from unity was statistically significant (p < 0.005). The SD of mean SNR after calibration also exhibited linear dependence on the SD of the mean SNR before calibration (r{sup 2} = 0.9997). This dependence was less than unity (m = 0.822 {+-} 0.008), and the difference from unity was also statistically significant (p < 0.005). Systems were separated into two groups: systems with a precalibration SNR higher than the median SNR (N = 7), and those with a precalibration SNR lower than the median SNR (N = 7). Posthoc analysis was performed to correct for expanded false positive results. After calibration, the authors noted differences in mean SNR within both high and low groups, but these differences were not statistically significant at the 0.05 level. SNR data from four additional systems and one system from those previously tested after replacement of its detector were compared to the 95% confidence intervals (CI) calculated from the postcalibration SNR data. The comparison indicated that four of these five systems were consistent with the CI derived from the previously tested 14 systems after calibration. Two systems from the paired group that remained outside the CI were studied further. One system was remedied with a grid replacement. The nonconformant behavior of the other system was corrected by replacing the image receptor. Conclusions: Exposure-dependent SNR measurements under conditions simulating thoracic imaging allowed us to develop criteria for digital flat-panel imaging systems from a single manufacturer. These measurements were useful in identifying systems with discrepant performance, including one with a defective grid, one with a defective detector, and one that had not been calibrated for gain and offset. The authors also found that the gain and offset calibration reduces variation in exposure-dependent SNR performance among the systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A forward bias method for lag correction of an a-Si flat panel detector

Purpose: Digital a-Si flat panel (FP) x-ray detectors can exhibit detector lag, or residual signal, of several percent that can cause ghosting in projection images or severe shading artifacts, known as the radar artifact, in cone-beam computed tomography (CBCT) reconstructions. A major contributor to detector lag is believed to be defect states, or traps, in the a-Si layer of the FP. Software methods to characterize and correct for the detector lag exist, but they may make assumptions such as system linearity and time invariance, which may not be true. The purpose of this work is to investigate a new hardware based method to reduce lag in an a-Si FP and to evaluate its effectiveness at removing shading artifacts in CBCT reconstructions. The feasibility of a novel, partially hardware based solution is also examined. Methods: The proposed hardware solution for lag reduction requires only a minor change to the FP. For pulsed irradiation, the proposed method inserts a new operation step between the readout and data collection stages. During this new stage the photodiode is operated in a forward bias mode, which fills the defect states with charge. A Varian 4030CB panel was modified to allow for operation in the forward bias mode. The contrast of residual lag ghosts was measured for lag frames 2 and 100 after irradiation ceased for standard and forward bias modes. Detector step response, lag, SNR, modulation transfer function (MTF), and detective quantum efficiency (DQE) measurements were made with standard and forward bias firmware. CBCT data of pelvic and head phantoms were also collected. Results: Overall, the 2nd and 100th detector lag frame residual signals were reduced 70%-88% using the new method. SNR, MTF, and DQE measurements show a small decrease in collected signal and a small increase in noise. The forward bias hardware successfully reduced the radar artifact in the CBCT reconstruction of the pelvic and head phantoms by 48%-81%. Conclusions: Overall, the forward bias method has been found to greatly reduce detector lag ghosts in projection data and the radar artifact in CBCT reconstructions. The method is limited to improvements of the a-Si photodiode response only. A future hybrid mode may overcome any limitations of this method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hysterosalpingography using a flat panel unit: Evaluation and optimization of ovarian radiation dose

Purpose: The aim of the present study was the evaluation and optimization of radiation dose to the ovaries (D) in hysterosalpingography (HSG). Methods: The study included a phantom study and a clinical one. In the phantom study, we evaluated imaging results for different geometrical setups and irradiation conditions. In the clinical study, 34 women were assigned into three different fluoroscopy modes and D was estimated with direct cervical TLD measurements. Results: In the phantom study, we used a source-to-image-distance (SID) of 110 cm and a field diagonal of 48 cm, and thus decreased air KERMA rate (KR) by 19% and 70%, respectively, for beam filtration: 4 mm Al and 0.9 mm Cu (Low dose). The least radiation exposure was accomplished by using the 3.75 pps fluoroscopy mode in conjunction with beam filtration: Low dose. In the clinical study, D normalized to 50 s of fluoroscopy time with a 3.75 pps fluoroscopy mode reached a value of 0.45 {+-} 0.04 mGy. Observers' evaluation of diagnostic image quality did not significantly differ for the three different modes of acquisition that were compared. Conclusions: Digital spot radiographs could be omitted in modern flat panel systems during HSG. Fluoroscopy image acquisitions in a modern flat panel unit at 3.75 pps and a beam filtration of 4 mm Al and 0.9 mm Cu demonstrate acceptable image quality with an average D equal to 0.45 mGy. This value is lower compared to the studied literature. For these reasons, the proposed method may be recommended for routine HSG examination in order to limit radiation exposure to the ovaries.

60 APPLIED LIFE SCIENCES↗