Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “office”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

America’s Cutting Edge CNC machining and metrology training

This paper describes the workforce development activities supported by America’s Cutting Edge (ACE), a national initiative for machine tool technology development and advancement. ACE is supported by the Department of Defense Industrial Base Analysis and Sustainment (IBAS) program from the Office of Industrial Policy. Both the online and in-person components of the computer numerically controlled (CNC) machining and metrology training programs are summarized and participation information is provided.

99 GENERAL AND MISCELLANEOUS↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correction to Reconciling Work Functions and Adsorption Enthalpies for Implicit Solvent Models: A Pt (111)/Water Interface Case Study

This errata is to correct the acknowledgment in the original published article. G.B. (partial support), V.-A.G., M.-T.N., and R.R. were supported by the U.S. Department of Energy, Office of Science, Basic Energy Sciences, Chemical Sciences, Geosciences, and Biosciences Division. Computer resources were provided by Research Computing at Pacific Northwest National Laboratory and the National Energy Research Scientific Computing Center (NERSC), a U.S. Department of Energy Office of Science User Facility operated under Contract No. DE-AC02-05CH11231. PNNL is operated by Battelle for the U.S. Department of Energy under Contract DE-AC05-76RL01830. G.B. acknowledges the EPSRC for partial support in PhD funding. The authors acknowledge the use of the IRIDIS High Performance Computing Facility (IRIDIS 5) and associated support services at the University of Southampton in the completion of this work. We are grateful to the UK Materials and Molecular Modeling Hub (Thomas HPC) for computational resources, which is partially funded by EPSRC (EP/P020194/1).

continuum solvation, metal/water interfaces, ab in↗

NWPEsSe: an Adaptive-Learning Global Optimization Algorithm for Nanosized Cluster Systems

Global optimization constitutes an important and fundamental problem in theoretical studies in many chemical fields, such as catalysis, materials or separations problems. In this paper, a novel algorithm has been developed for the global optimization of large systems including neat and ligated clusters in gas phase, and supported clusters in periodic boundary conditions. The method is based on an updated artificial bee colony (ABC) algorithm method, that allows for adaptive-learning during the search process. The new algorithm is tested against four classes of systems of diverse chemical nature: gas phase Au_55, ligated Au_8^(2+), Au_8 supported on graphene oxide and defected rutile, and a large cluster assembly ?[Co?_6 Te_8 (PEt_3 )_6][C_60 ]_n, with sizes ranging between 1 to 3 nm and containing up to 1300 atoms. Reliable global minima (GMs) are obtained for all cases, either confirming published data or reporting new lower energy structures. The algorithm and interface to other codes in the form of an independent program, Northwest Potential Energy Search Engine (NWPEsSe), is freely available and it provides a powerful and efficient approach for global optimization of nanosized cluster systems. The work described in this publication was performed at Pacific Northwest National Laboratory (PNNL), which is operated by Battelle for the United States Department of Energy (DOE) under Contract DE-AC05-76RL0180. J. Z. and V.-A. G. acknowledge support from DOE, Office of Science, Office of Basic Energy Sci-ences, Chemical, Geological and Biological Sciences Division and computing resources from PNNL’s Research Computing Facility and the National Energy Research Scientific Computing Center.

Zhang, Jun↗

Measuring Electronic Structure of Multiply Charged Anions to Understand their Chemistry: A Case Study on Gaseous Polyhedral closo-Borate Dianions

Research on multiply charged anions (MCAs) in the gas phase has been intensively performed during the last decades, mainly to understand fundamental molecular physics phenomena, e.g., intramolecular Coulomb repulsion and existence of the repulsive Coulomb barrier. However, the relevance of these investigations with respect to understanding MCAs’ chemistry appears often vague. Here, we discuss how insights on the electronic structure obtained from negative ion photoelectron spectroscopy (NIPES) combined with theoretical calculations and collision induced dissociation can provide fundamental understanding on the intrinsic chemical reactivity of MCAs and their fragments. This is exemplified on our studies on polyhedral closo-borate dianions [BnXn]2- (n = 6, 10, 11, 12; X = H, F-I, CN) and their fragment ions. For example, the rational design of closo-borate dianions with specific electronic properties is described, which leads to generating highly reactive fragments. Depending on the dianionic precursor, these fragments are either tuned to bind noble gases effectively or to activate small molecules like CO and N2. The intrinsic electronic properties of closo-borate dianions are further compared to their electrochemistry in solutions, revealing solvent effects on the redox potentials. Neutral host molecules such as cyclodextrins are found to bind strongly to [BnXn]2-, and gas phase NIPES provides insights on the intrinsic host-guest interactions. Finally, outlooks including the direct NIPES of molecular fragment ions which cannot be generated in the condensed phase and their utilization in preparative mass spectrometry are discussed. J.W is grateful to the Volkswagen foundation for a Freigeist Fellowship. X. B. W acknowledges support from the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, the Division of Chemical Sciences, Geosciences and Biosciences. We are grateful to our colleagues who support our work on gas phase ion chemistry for many years. In particular we acknowledge the members of our groups, the Asmis group (Leipzig), Laskin Group (West Lafayette), the Jenne group (Wuppertal), the Finze group (Würzburg), the Grabowsky group (Bern), and the Sun group (Shanghai). We are grateful to Edoardo Apra for the many theoretical investigations on closo-borate anions. JW acknowledges support of Harald Knorke and Markus Rohdenburg with the preparation of graphical material, and XBW thanks Qinqin Yuan for the help in organizing references.

Warneke, Jonas↗

Nanometer-Scale Correlations in Aqueous Salt Solutions

The intermediate-range (1–4 nm) correlation of cations, an- ions, and water in aqueous alkaline earth salt solutions is measured using synchrotron X-ray diffraction. We differentiate from the entire solution structure factor, S(Q), a separate region at low Q (<1 °A-1) containing local diffraction maxima (pre-peaks) that indicate nanometer-scale oscillatory behavior. These features are quantitatively reproduced with classical molecular dynamics simulations. At high concentrations, the pre-peaks emerge from correlations arising from existence of small quasi close-packed lattice- like structures comprised of cation hydration spheres. We also analyze the concentration dependence of the pre-peak and discuss the overall results in light of the rich literature dealing with intermediate-range correlations underlying universal phenomena in concentrated electrolytes. The authors were supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Biosciences. Pacific Northwest National Laboratory (PNNL) is operated by Battelle for the U.S. Department of Energy under Contract No. DE-AC05-76RL01830. Computing resources were generously allocated by PNNL's Institutional Computing program. DOE Contract No. DEAC02- 06CH11357 supports operation of the Advanced Photon Source at Argonne National Laboratory.

Chemical physics, nucleation, Madelung potential↗

Author Correction: The role of manganese in CoMnO x catalysts for selective long-chain hydrocarbon production via Fischer-Tropsch synthesis

Correction to: Nature Communicationshttps://doi.org/10.1038/s41467-024-54578-3, published online 27 November 2024. The original version of this Article omitted a line in the Acknowledgements section: Work at the Molecular Foundry was supported by the Office of Science, Office of Basic Energy Sciences, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. This has been now added into the last line of the acknowledgements section in both the PDF and HTML versions of the Article.

99 GENERAL AND MISCELLANEOUS↗

Theoretical insights into the surface physics and chemistry of redox-active oxides

Redox active oxides are ubiquitous in materials applications, including catalysis, photovoltaics, self-cleaning glasses, chemical sensors, and electronic components. Their utility derives from their unique ability to access multiple metal charge states within a finite energy window. However, this property also confounds our ability to study reducible oxides, because it leads to structural, compositional, and electronic complexities that elude simplistic models of materials structure and function. Oxygen vacancies play a critical role in shaping the functional properties of such oxides; most notably, they lead to mobile charge imbalances that impact surface processes at significant distances from the originating defect. Atomistic simulations are inherently equipped to illuminate these phenomena at a fundamental level; however, reducible oxides pose great challenges due to the high level of electron correlation needed to correctly describe them. Knowing how defects form, couple, propagate, agglomerate, or repel each other and influence the surface properties of reducible oxides is only now coming into the grasp of modern theory and simulation capabilities. This knowledge is also key to discovering and controlling emergent materials processes at nanometer scale and beyond. The manuscript was written with support of all three authors from U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences. Work by RR and VG was performed at Pacific Northwest National Laboratory (PNNL), which is a multi-program laboratory operated by Battelle for DOE under Contract DE AC05 76RL01830. AS was supported under Award DE-SC0007347.

Rousseau, Roger J.↗

Determinants for proton location and electron coupled proton transfer in hydrogen bonded pentafluorophenol-anion clusters

This work aims to reveal the determinant factors for proton locations and electron coupled proton transfer (ECPT) in biologically relevant hydrogen bonded systems. Pentafluorophenol-anion clusters [C6F5O-•H+•A-]- are chosen to model active sites of biological functions, with the anion A- being systematically varied to ensure the proton affinities (PAs) of the anions well cover the referenced PA of C6F5O- from being appreciably smaller, similar, and to significantly larger. Negative ion photoelectron spectroscopy of these clusters provides spectroscopic evidence showing that proton location in the anionic state is largely following the PA prediction, while ECPT is observed only for the clusters with the anion possessing the electron binding energy (EBE) significantly larger than that of the referenced C6F5O-. Theoretical calculations suggest these clusters are stabilized by forming single strong hydrogen bond between donor and acceptor, and the associated charge and MO analyses fully support the experimental observations. The current holistic cluster model study indicates that PA is the right determinant that can be used to predict the proton location and describe hydrogen bonding structures, while both PA and EBE of anionic groups play important roles in facilitating ECPT process. This work was supported by U.S. Department of Energy (DOE), Office of Basic Energy Sciences, Division of Chemical Science, Geosciences, and Biosciences (X.-B.W.), and performed using EMSL, a national scientific user facility sponsored by DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory, which is operated by Battelle Memorial Institute for the DOE. Part of this work was supported by the National Natural Science Foundation of China (No-11604046 for JZ; No. 11727810 for ZRS), as well as “Chenguang Program” by Shanghai Education Development Foundation, Shanghai Municipal Education Commission (No. 16CG38) and Natural Science Foundation of Shanghai (No. 16ZR1448100) (JZ).

Zhang, Jian↗