Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear physics detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Measurement of turbulent electron temperature fluctuations on the ASDEX Upgrade tokamak using correlated electron cyclotron emission

Turbulent temperature fluctuations are measured on the ASDEX Upgrade tokamak using pairs of closely spaced, narrow-band heterodyne radiometer channels and a standard correlation technique. The pre-detection spacing and bandwidth of the radiometer channel pairs is chosen such that they are physically separated less than a turbulent correlation length, but do not overlap. The radiometer has 4 fixed filter frequency channels and two tunable filter channels for added flexibility in the measurement position. Relative temperature fluctuation amplitudes are observed in a helium plasma to be δT/T = (0.76 ± 0.02)%, (0.67 ± 0.02)%, and (0.59 ± 0.03)% at normalised toroidal flux radius of ρ{sub tor} = 0.82, 0.75, and 0.68, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Physics Role and Potential of future Atmospheric Detectors

We discuss the physics capabilities of basic types of future atmospheric detectors being considered at present, with their strengths and limitations, and compare them with those of long-baseline (LBL) experiments. We also argue that recent studies signal the importance of synergistically combining complementary features of both these classes of experiments in order to accrue maximum benefit towards furthering our goal of building a complete picture of neutrino properties and parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation Of A Photofission-Based Cargo Interrogation System

A comprehensive model has been developed to characterize and optimize the detection of Bremsstrahlung x-ray induced fission signatures from nuclear materials hidden in cargo containers. An effective active interrogation system should not only induce a large number of fission events but also efficiently detect their signatures. The proposed scanning system utilizes a 9-MV commercially available linear accelerator and the detection of strong fission signals i.e. delayed gamma rays and prompt neutrons. Because the scanning system is complex and the cargo containers are large and often highly attenuating, the simulation method segments the model into several physical steps, representing each change of radiation particle. Each approximation is carried-out separately, resulting in a major reduction in computational time and a significant improvement in tally statistics. The model investigates the effect on the fission rate and detection rate by various cargo types, densities and distributions. Hydrogenous and metallic cargos, homogeneous and heterogeneous, as well as various locations of the nuclear material inside the cargo container were studied. We will show that for the photofission-based interrogation system simulation, the final results are not only in good agreement with a full, single-step simulation but also with experimental results, further validating the full-system simulation.

07 ISOTOPE AND RADIATION SOURCES↗

A Probabilistic Model-Based Diagnostic Framework for Nuclear Engineering Systems

A fault diagnostic framework was investigated in this study for applications in thermal–hydraulic systems of nuclear power plants. The proposed framework consists of quantitative model-based diagnosis, statistical change detection and probabilistic reasoning. The use of physics-based diagnostic models provides high detection sensitivity and allows noise and measurement uncertainty to be incorporated robustly. Performance-related parametric models for each component are constructed based on first principles. Numerical model residuals are generated using the concept of analytical redundancy. Statistical change detection methods are employed to detect non-zero residuals in the presence of uncertainty. The diagnosis task is performed using Bayesian inference to detect and localize possible faults. Application to a single-phase heat exchanger for demonstration showed that the proposed probabilistic framework can provide improved results in comparison with traditional approaches while remaining less sensitive to false alarms in the presence of measurement and modeling uncertainty.

Bayesian network↗

ResNet and CycleGAN for pulse shape discrimination of He-4 detector pulses: Recovering pulses conventional algorithms fail to label unanimously

Pulse shape discrimination (PSD) capable detectors, such as He-4, that respond to neutron and gamma-ray 7 interactions have a threshold deposited energy value below which n/γ discrimination vanishes when using 8 conventional PSD algorithms. Recent attempts in applying supervised learning based artificial neural 9 networks for PSD use the pulses in the separated regions to train the networks so they can be used to classify 10 another set of separated pulses. In doing so, pulses previously indistinguishable are not recovered for 11 classification, which would have increased the number of neutron and gamma-ray pulses that could be used 12 for further analysis. Assuming the reason why conventional PSD algorithms have unseparated regions is 13 because the parameter space of the algorithms fail to capture the intrinsic (but subtle) distinguishing 14 behavior of some of the neutron and gamma-ray pulses, a cycle-consistent generative adversarial network 15 (CycleGAN) was trained to amplify those differences and extract well separated neutron and gamma-ray 16 clusters. Results show that, once the network is trained with pulses from separated and unseparated regions, 17 it was able to transform the pulses in the unseparated region to improve the PSD. Subsequent n/γ 18 classification was performed using deep residual network (ResNet) that takes pulses with 512 data points 19 as an input. Two different ResNets were explored – simple ResNet and modified ResNet which takes 20 segmented pulse inputs in the first layer and the corresponding time axis values in the last hidden layer. 21 The later approach enables the network to extract time correlated pulse features to enhance its ability to 22 capture the pulse behaviors relevant for PSD. Although it achieves slightly lower accuracy, 99.41% versus 23 99.89%, based on simply counting the number of correct n/γ labels assigned, compared to the simple 24 ResNet, the modified ResNets architecture was able to decreases the cross-entropy loss function by half, 25 which implies that the correct n/γ labels assigned are less likely to be accidental. PSD parameter 26 distributions based on n/γ classification by ResNet before and after transforming unseparated pulses using 27 CycleGAN show that by enhancing the separation between neutrons and gamma-rays, the transformation 28 helps improve the performance of classifier networks that are trained using labeled dataset. The 29 enhancement of neutron and gamma-ray separation by the CycleGAN increased the PSD figure of merit 30 (FOM) by up to 70% in some regions. Here, the results show that, if a given detector achieves clear separation 31 between neutron and gamma-ray pulses in any energy region, such neural network approaches can help 32 lower the energy threshold for the separation and increasing the number of neutron and gamma-ray pulses 33 that can be used for further analysis.

4He↗

Design and expected performance of a fast neutron attenuation probe for light element density measurements

In this paper, we present the design and expected performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20–30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8±0.5% of the true value. Lastly, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5–10% level for a two hour scan time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Neutron-Rich Oxygen Isotopes with MoNA

The Modular Neutron Array (MoNA) was used in conjunction with a large-gap dipole magnet (Sweeper) to measure neutron-unbound states in oxygen isotopes close to the neutron dripline. While no excited states were observed in {sup 24}O, a resonance at 45(2) keV above the neutron separation energy was observed in {sup 23}O.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-energy Laser-accelerated Electron Beams for Long-range Interrogation

We are studying the use of 0.1-1.0 GeV laser-accelerated electron beams as active interrogation probes for long-standoff radiography or nuclear activation of concealed special nuclear material. Use of beams in this energy range is largely unexplored, but such beams could provide notable advantages over lower-energy beams and x-rays. High-energy laser-accelerated electrons exhibit large penetration range through air and solids, and low beam divergence for both direct beams and secondary Bremsstrahlung x-rays. We present laboratory measurements of radiography and activation, using the high-power Diodes laser system at the University of Nebraska, as well as MCNP and GEANT Monte Carlo simulation results used to aid experiment design and interpretation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Antiproton, positron, and electron imaging with a microchannel plate/phosphor detector

A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electrons and positrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity map photoelectron-photoion coincidence imaging on a single detector

Here we report on a new simplified setup for velocity map photoelectron-photoion coincidence imaging using only a single particle detector. We show that both photoelectrons and photoions can be extracted toward the same micro-channel-plate delay line detector by fast switching of the high voltages on the ion optics. This single detector setup retains essentially all the features of a standard two-detector coincidence imaging setup, viz., the high spatial resolution for electron and ion imaging, while only slightly decreasing the ion time-of-flight mass resolution. The new setup paves the way to a significant cost reduction in building a coincidence imaging setup for experiments aiming to obtain the complete correlated three-dimensional momentum distribution of electrons and ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Measurement of the 235 U Antineutrino Energy Spectrum with the PROSPECT-I Detector at HFIR

This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely 235 U-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. Further, the reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5–7 MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.0 and 3.7 standard deviations the hypotheses that antineutrinos from 235 U are solely responsible and noncontributors to the excess observed at commercial reactors, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GaAs Schottky Barrier Detectors for Alpha-Particle Spectrometry at Temperatures up to 120°C

GaAs Schottky barrier detectors for α particle spectrometry have been tested. Detectors had an input window area of 80 mm{sup 2} and a working barrier layer thickness of 40–50 μm. The energy resolution (FWHM) measured on 5.499 MeV α line of {sup 238}Pu source amounted to 17.5 keV at a generator peak width of 7.8 keV. In the measurements on a {sup 226}Ra source, detectors showed linear response and nearly 100% charge collection efficiency at reverse bias above 65 V for all energies of α particles emitted from the source. Tests for thermal stability showed that the proposed detectors can be used in alpha-spectrometry of radionuclides at temperatures up to 120°C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-Enhanced Calorimetry for Hadrons (Nech): Final Report

We present the results of a project to apply scintillator technology recently developed at Louisiana Tech University to hadronic calorimetry. In particular, we developed a prototype calorimeter module incorporating scintillator embedded with metal oxide nanoparticles as the active layers. These metal oxide nanoparticles of gadolinium oxide, have high cross-sections for interactions with slow neutrons. As a part of this research project, we have developed a novel method for producing plastic scintillators with metal oxide nanoparticles evenly distributed through the plastic without aggregation. We will test the performance of the calorimeter module in test beam and with a neutron source, in order to measure the response to the neutron component of hadronic showers. We will supplement our detector prototyping activities with detailed studies of the effect of neutron component on the resolution of hadronic energy measurements, particular in the next generation of particle flow calorimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of Gamma Detectors Based on Magnetic Ag:Er Microcalorimeters

This report discusses the photolithographic fabrication of ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs). The MMC uses a novel Er-doped silver sensor (Ag:Er) that is expected to have higher sensitivity than the Er-doped gold (Au:Er) sensors currently in use. The MMC also integrates the first-stage SQUID preamplifier on the same chip as the MMC gamma detector to increase its signal-to-noise ratio. In addition, the MMC uses a passive Ta-Nb heat switch to replace one of the common long-term failure points in earlier detectors. This report discusses the fabrication process we have developed to implement the proposed improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Efficiency CdZnTe Position-Sensitive VFG Gamma-Ray Detectors for Safeguards Applications

The goal of this project is to incorporate a Cadmium-Zinc-Telluride (CdZnTe or CZT) detector (with 1% or better resolution) into a bench-top prototype for isotope identification and related safeguards applications. The bench-top system is based on a 2x2 array of 6x6x20 mm 3 position-sensitive virtual Frisch-grid (VFG) CZT detectors. The key features of the array are that it allows for the use of average-grade CZT material with a moderate content of defects, and yet it provides high energy resolution, 1% FWHM at 662 keV, large effective area, and low-power consumption. The development of this type of 3D detector and new instruments incorporating them is motivated by the high cost and low availability of large, > 1 cm 3 , CZT crystals suitable for making multi-pixel detectors with acceptable energy resolution and efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗