Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nonlinear optic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Co-Design of Free-Space Metasurface Optical Neuromorphic Classifiers for High Performance

Classification of features in a scene typically requires conversion of the incoming photonic field into the electronic domain. Recently, an alternative approach has emerged whereby passive structured materials can perform classification tasks by directly using free-space propagation and diffraction of light. In this manuscript, we present a theoretical and computational study of such systems and establish the basic features that govern their performance. We show that system architecture, material structure, and input light field are intertwined and need to be co-designed to maximize classification accuracy. Our simulations show that a single layer metasurface can achieve classification accuracy better than conventional linear classifiers, with an order of magnitude fewer diffractive features than previously reported. For a wavelength λ, single layer metasurfaces of size 100λ × 100λ with an aperture density λ –2 achieve ~96% testing accuracy on the MNIST data set, for an optimized distance ~100λ to the output plane. This is enabled by an intrinsic nonlinearity in photodetection, despite the use of linear optical metamaterials. Furthermore, we find that once the system is optimized, the number of diffractive features is the main determinant of classification performance. The slow asymptotic scaling with the number of apertures suggests a reason why such systems may benefit from multiple layer designs. Finally, we show a trade-off between the number of apertures and fabrication noise.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

End–to–End Metasurface Design for Temperature Imaging via Broadband Planck‐Radiation Regression

A theoretical framework is presented for temperature imaging from long-wavelength infrared (LWIR) thermal radiation (e.g., 8–12 µm) through the end-to-end design of a metasurface-optics frontend and a computational-reconstruction backend. A new nonlinear reconstruction algorithm, “Planck regression”, is introduced to reconstruct the temperature map from a gray scale sensor image, even in the presence of severe chromatic aberration, by exploiting black body and optical physics particular to thermal imaging. This algorithm is combined with an end-to-end approach that optimizes manufacturable, single-layer metasurfaces to yield the most accurate reconstruction. The designs demonstrate high-quality, noise-robust reconstructions of arbitrary temperature maps (including completely random images) in simulations of an ultra-compact thermal-imaging device. Here, it is also shown that Planck regression is much more generalizable to arbitrary images than a straightforward neural-network reconstruction, which requires a large training set of domain-specific images.

36 MATERIALS SCIENCE↗

Bound Exciton Complexes in Near-Infrared Emitting Quantum Shells

Near-infrared (NIR) light sources based on colloidal semiconductor nanocrystals (NCs) represent a scalable, low-cost alternative to epitaxial semiconductor platforms. However, their performance remains hindered by rapid Auger recombination, a problem that is particularly pronounced in narrow-bandgap materials. Here, we report on CdS/HgS/CdS and CdS/HgCdSe/ ZnS quantum shells (QSs), a class of spherical quantum wells specifically engineered for a suppression of nonradiative Auger processes. Fabricated QSs exhibit tunable NIR emission with photoluminescence quantum yields reaching ∼60% below 1000 nm and up to 30% near 1300 nm. Optical gain and stimulated emission were observed in CdS/HgS/CdS QSs. In contrast, CdS/HgCdSe/ZnS QSs displayed a photoinduced absorption in lieu of optical gain despite demonstrating a comparatively stronger Auger suppression. Transient absorption spectroscopy revealed that this phenomenon arises from the formation of bound multiexciton complexes that induce long-lived sub-bandgap multiexciton states. The observation of such bound excitonic clusters at room temperature offers a pathway toward nonlinear NIR photonic phenomena, including biexciton−exciton cascade emission, optical modulation, and singleexciton gain.

Auger recombination↗

Phase-Sensitive Coherence and the Classical-Quantum Boundary in Ghost Imaging

The theory of partial coherence has a long and storied history in classical statistical optics. the vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-sate light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost imaging most closely mimicking those obtained in biphotons, and we derived the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.

coherence theory↗

Multimodal (Non)Linear Optical Nanoimaging and Nanospectroscopy

This article highlights recent advances in linear and nonlinear spectral nanoimaging. The described developments are motivated by the need to characterize molecular and material systems noninvasively with nanometer spatial and femtosecond temporal resolution. Indeed, the ability to image and chemically characterize heterogeneous interfaces with joint nano–femto resolution is a prerequisite to advancing our fundamental understanding of processes as diverse as heterogeneous catalysis, microbial communication, and energy flow in pristine/defect-containing low-dimensional quantum materials, to name a few. We describe pioneering work and recent demonstrations of (non)linear optical nanoimaging and nanospectroscopy, with an emphasis on high spatial resolution measurements conducted under ambient laboratory conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bandwidth extension and conversion efficiency improvements beyond phase matching limitations using cavity-enhanced OPCPA

The conversion efficiency and phase matching bandwidth of ultrafast optical parametric amplification (OPA) are constrained by the dispersion and nonlinear coefficient of the employed crystal as well as pulse shaping effects. In our work we show that an enhancement cavity resonant with the pump seeded at the full repetition rate of the pump laser can automatically reshape the small-signal gain in optical parametric chirped-pulse amplification (OPCPA) to achieve close-to-optimal operation. This new method termed cavity-enhanced OPCPA or C-OPCPA significantly increases both the gain bandwidth and the conversion efficiency, in addition to boosting gain for high-repetition-rate amplification. The goal in C-OPCPA is to arrive at a condition of impedance matching at all temporal coordinates, such that, in the absence of linear losses, all the incident pump power is dissipated in the nonlinear loss element, i.e., converted to signal and idler. The use of a low finesse enhancement cavity resonant with a low average power (<1W) and a high repetition rate (78MHz) pump source is shown to achieve more than 50% conversion efficiency into signal and idler from the coupled pump in an optical parametric process, whereas an equivalent amount of pump power in a single-pass configuration leads to negligible conversion. Additionally, the gain bandwidth is extended by a factor of 3-4 beyond the phase-matching limit. Our empirical observations are corroborated by a numerical analysis of depletion optimizing the single-pass case, which assesses the underlying impedance matching that is responsible for the observed performance improvements.

47 OTHER INSTRUMENTATION↗

Molecular and solid-state topological polaritons induced by population imbalance

Abstract Strong coupling between electronic excitations in materials and photon modes results in the formation of polaritons, which display larger nonlinearities than their photonic counterparts due to their material component. We theoretically investigate how to optically control the topological properties of molecular and solid-state exciton–polariton systems by exploiting one such nonlinearity: saturation of electronic transitions. We demonstrate modification of the Berry curvature of three different materials when placed within a Fabry–Perot cavity and pumped with circularly polarized light, illustrating the broad applicability of our scheme. Importantly, while optical pumping leads to nonzero Chern invariants, unidirectional edge states do not emerge in our system as the bulk-boundary correspondence is not applicable. This work demonstrates a versatile approach to control topological properties of novel optoelectronic materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low-Frequency Oscillations in Optical Measurements of Metal-Nanoparticle Vibrations

Time-resolved optical measurements of vibrating metal nanoparticles have been used extensively to probe the ultrafast mechanical properties of the nanoparticles and of the surrounding liquid, but nearly all investigations so far have been limited to the linear regime. Herein, we report the observation of a low-frequency oscillating signal in transient-absorption measurements of nanoparticles with octahedral gold cores and cubic silver shells; the signal appears at the difference of two mechanical vibrational frequencies in the particles, suggesting a nonlinear mixing process. We tentatively attribute this proposed mixing to a nonlinear coupling between a vibrational mode of the nanoparticle and its optical-frequency plasmon resonance. The optimization of this nonlinear transduction may enable high-efficiency opto-mechanical frequency mixing in the GHz-THz frequency regime.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Analytic Chromaticity Formulas for the Muon g -2 experiment at fermilab

The Muon g-2 Experiment (E989) at Fermilab measured the muon anomalous magnetic moment aμ with unprecedented precision of 127 ppb using a storage ring. The experiment pushed the limits in terms of accuracy and systematic errors. Achieving the 78-ppb total systematic uncertainty required precise beam dynamics modeling and corrections for effects on the measured muon precession frequency. Here, we derived the first analytic aberration formulas up to the second order for the muon g-2 storage ring’s combined-function electrostatic quadrupoles (superimposed magnetic dipole and electric quadrupole fields) using an order-by-order perturbation method. From these, we obtained the exact chromaticity formulas for three ring models of different granularity and validated them against numerical calculations using COSY INFINITY, achieving analytic-numerical agreement to ⁠$\mathscr{O}(10^{-10})$. This work resolved discrepancies between previous approximate derivations and provided essential beam dynamics results for Runs 4-6 analyses. We also calculated nonlinear chromaticities up to ninth order. The experiment completed its final Run 6 in July 2023, collecting 21 times more data than the previous muon g-2 experiment at Brookhaven National Laboratory, with the final result announced in June 2025.

aberrations↗

Selected magnetoelectrical phonon stiffening in Cr 2 ⁢O 3

A thorough understanding of lattice dynamics, particularly how they couple with spin through spin-phonon interactions, is crucial for pioneering new spin-caloritronic applications. Here, despite extensive studies on Cr 2 ⁢O 3 , the origin of nonlinear thermal expansions and the unusual stiffening of optical phonon modes is still elusive. Through inelastic neutron scattering and atomistic calculations, we found that these behaviors can be attributed to the renormalization of electron states owing to the magnetic transition, and we ruled out the effects from thermal expansion, phonon anharmonicity, magnetostriction, or electron-phonon interactions. Importantly, our quantitative modeling suggests that the common belief that dynamic spin-phonon interactions are the origin of anomalous phonon energy stiffening in magnetic compounds does not apply in Cr 2 ⁢O 3 .

DFT+U↗

Cross-Beam Energy Transfer Saturation by Ion Heating

Cross-beam energy transfer (CBET) saturation by ion heating was measured in a gas-jet plasma characterized using Thomson scattering. Here, a wavelength-tunable ultraviolet (UV) probe laser beam was interacted with four intense UV pump beams to drive large-amplitude ion-acoustic waves. For the highest-intensity interactions, the power transferred to the probe laser dropped, demonstrating ion-acoustic wave saturation. Over this time, the ion temperature was measured to increase by a factor of 7 during the 500-ps interaction. Particle-in-cell simulations show ion trapping and a subsequent ion heating consistent with measurements. Linear kinetic CBET models were found to agree well with the observed energy transfer when the measured plasma conditions were used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mid-infrared frequency doubling using strip-loaded silicon nitride on epitaxial barium titanate thin film waveguides

Broadband mid-infrared (mid-IR) frequency doubling was demonstrated using nonlinear barium titanate (BTO) thin films. The device has a strip-loaded waveguide structure consisting of top silicon nitride (SiN) strips and an underneath BTO guiding layer. The epitaxial BTO was deposited on a strontium titanate (STO) substrate by pulsed-laser deposition. Through a SiN grating coupler, the pumping mid-IR light at wavelength &#x03BB;<!-- λ --> = 3.30 &#x2212;<!-- - --> 3.45 &#x00B5;<!-- µ --> m was coupled into the nonlinear BTO layer, where the spectrum of the near-infrared (NIR) second-harmonic generation was characterized. The developed BTO waveguides provide a platform for mid-IR nonlinear integrated photonics and on-chip quantum optics.

42 ENGINEERING↗

Design of double- and multi-bend achromat lattices with large dynamic aperture and approximate invariants

A numerical method to design nonlinear double- and multi-bend achromat (DBA and MBA) lattices with approximate invariants of motion is investigated. The search for such nonlinear lattices is motivated by Fermilab’s Integrable Optics Test Accelerator (IOTA), whose design is based on an integrable Hamiltonian system with two invariants of motion. While it may not be possible to design an achromatic lattice for a dedicated synchrotron light source storage ring with one or more exact invariants of motion, it is possible to tune the sextupoles and octupoles in existing DBA and MBA lattices to produce approximate invariants. In our procedure, the lattice is tuned while minimizing the turn-by-turn fluctuations of the Courant-Snyder actions J x and J y at several distinct amplitudes, while simultaneously minimizing diffusion of the on-energy betatron tunes. The resulting lattices share some important features with integrable ones, such as a large dynamic aperture, trajectories confined to invariant tori, robustness to resonances and errors, and a large amplitude-dependent tune-spread. Compared to the nominal NSLS-II lattice, the single- and multi-bunch instability thresholds are increased and the bunch-by-bunch feedback gain can be reduced.

43 PARTICLE ACCELERATORS↗

Optical synchronization of millimeter-wave oscillators for distributed architecture

A review of various methods of phase and frequency synchronization of active MMIC based transmit/receive modules is presented, and particular emphasis is placed on the synchronization of oscillators through the use of an indirect subharmonic optical injection locking technique. In this approach, the nonlinear behavior of large-signal modulated laser diodes and solid-state oscillators is exploited to extend the bandwidth of the synchronizing link to the millimeter-wave frequency range. Experimental results of the phase and frequency coherency of two 21.5 GHz FET oscillators are reported. Optimum performance is achieved at a subharmonic factor of 1/4, with a locking range of 84 MHz and a phase noise degradation of only 14 dB. The phase coherency measurement of two injection-locked oscillators points to a phase shift, which is introduced as a result of the frequency detuning between the slave and master oscillator signals. A scheme to correct for this phase error is presented.

Daryoush, Afshin S.↗