Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Translating Material-Level Characterization of Carbon-Nanotube-Reinforced Composite Gridlines to Module-Level Degradation

Cell cracks in PV modules caused by poor handling during shipping and installation as well as from extreme weather events can lead to gradual or immediate power degradation. To directly address cell-crack-induced degradation, we have formulated a carbon nanotube additive for commercial screen printed silver pastes. We have shown in previous work that these metal matrix composites have little to no effect on the cell's efficiency while enhancing the metallization's fracture toughness and electrical gap-bridging capability. In this work, we focus on translating materials level characterization techniques to module level degradation. We found that we get conflicting results from two different methods of measuring the metallization's ability to electrically bridge gaps in cracked solar cells. Mini-module stress testing is currently underway to determine which materials characterization correlates well with the min-module degradation characteristics.

carbon nanotubes↗

Rear-Side Irradiance Simulation of Field PV Modules

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation-dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial_Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand real orld outdoor degradation.

backsheet↗

Recovery of Glass and Silicon Solar Cells from Si-Modules Through Laser Processing

This study demonstrates an innovative and environmentally friendly laser-based approach for the efficient recovery of glass and silicon solar cells, allowing the recycling of photovoltaic modules. The methodology involves the use of a high-power pulsed laser beam focusing at various interfaces within the modules. Specifically, the delivery of ultra-short pulse laser energy at the interfaces of glass and polymeric encapsulants, as well as at the encapsulants and silicon solar cells, facilitates the debonding of polymers from both glass and silicon cell surfaces. The debonding occurs through photothermal, ablation, chemical modification, and localized heat generation. The research successfully demonstrates the recovery of glass from commercial mini solar modules of size 11.5 x 6.8 cm 2 and a silicon wafer of size 3.0x1.6 cm 2 . Ongoing efforts aim to extend the effectiveness of this laser-based methodology to comprehensively recycle larger-size components. This innovative approach holds promise for addressing environmental concerns associated with the disposal of solar modules, contributing to sustainable practices in the renewable energy sector.

glass↗

An Effective Current Balancing Method for Inverters With Paralleled Silicon Carbide Power Modules

Silicon carbide (SiC) MOSFET has many superior characteristics in high power applications. Paralleling the SiC devices is an effective approach to increase the current capacity of the system, which also leads to current sharing issues. In this article, both transient and steady-state current sharing issues are studied for the high-power grid-tied inverters with paralleled SiC modules with an effective current balancing strategy proposed to address both issues simultaneously. The steady-state imbalance current due to the parameter mismatch is suppressed by the self-inductance of power cables used for paralleling connection. With the elimination of steady-state imbalance current, the transient imbalance current sensing is much simplified and can be realized by using low-cost current sensors. With the sensed imbalance current, a closed-loop control approach is proposed to adjust the modulation reference signal for each module to mitigate the remaining transient imbalance current. Furthermore, the proposed method is straightforward to implement with enhanced compatibility and flexibility compared to existing methods. Experimental studies are performed using inverters with 2 and 4 power modules paralleled in each phase to demonstrate the effectiveness of the proposed method.

42 ENGINEERING↗

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

Here, the optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5cx0.5cmx20cm . The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2x8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76%±0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1σz -position resolution for gamma interactions in the 0.3–0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1σ interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prototype Design of Global Common Module for ATLAS Experiment’s Phase-II Upgrade

A new Global Trigger subsystem will be installed in the Level-0 Trigger as part of HL-LHC Upgrade of ATLAS during the upcoming Long-Shutdown 3. It will feature new and improved trigger hardware and algorithms, and an increased maximum output rate of 1 MHz. The Global Trigger will run offline-like trigger algorithms on full-granularity data, gathered from several sub-detectors and trigger-processing subsystems. A single Global Common Module (GCM) hardware is implemented across the Global Trigger system to be used as Multiplexer Processor, Global Event Processor and CTP Interface (gCTPi). This common hardware platform method will minimize the complexity of the firmware and simplify the system design and long-term maintenance. The GCM prototype is an ATCA front form factor board with two Xilinx Virtex UltraScale+ FPGA VU13P and one ZYNQ UltraScale+ FPGA ZU19EG and seventeen 25.78125 Gb/s FireFly duplex optical modules on it. The total power consumption of this board must be less than 350 W, and the temperature of the optical modules should be less than 70 °C in the worst case. The VU13Ps serve as algorithms processor nodes such as MUX, GEP and gCTPi, and the ZU19EG with Peta Linux OS running on it, is used as Command/Control/Readout Unit to configure and monitor the board and communicate with the ATLAS Detector Control System (DCS). The development of an ATCA blade with three large FPGAs and about 200 optical links running at 25Gb/s is a very challenging task, and the successful test results have demonstrated this GCM prototype as an advancement of state-of-the-art electronics module design in HEP experiments. This paper presents the hardware design considerations, functionalities, and performance test results of this GCM prototype.

47 OTHER INSTRUMENTATION↗

X-Ray and Particle Detection With the Si(Li) Tracker Module of the GAPS Experiment

Here, this work describes the architecture and the experimental results from the characterization of the lithium-drifted silicon (Si(Li)) detector module, which constitutes the building block of the tracker in the general antiparticle spectrometer (GAPS) experiment to search for dark matter. The instrument is designed for the identification of low-energy cosmic anti-nuclei (antiprotons, antideuterons, and antihelium) to be performed during an Antarctic long-duration balloon flight scheduled for late 2025. The GAPS Si(Li) tracker, that is the core of the instrument, is the assembly of 252 modules, each comprised of four Si(Li) detectors and a full custom-integrated circuit designed for detector readout and produced in a commercial 180-nm planar CMOS technology. A general overview of the detector module architecture and its components is provided, together with a description of the test setup and the experimental results obtained from the characterization of the low-noise analog readout channel. In order to verify the effective operation of the entire module, results concerning the detection of X-rays from a 241Am source and cosmic muons are also provided.

Manghisoni, Massimo [Università di Bergamo (Italy)↗

Testing of the ITER Central Solenoid Modules

The ITER Central Solenoid is under fabrication by the U.S. ITER organization and its subcontractors. U.S. ITER will supply seven modules to ITER IO, six of which will be assembled in a stack that forms the ITER Central Solenoid. The first modules that were built by GA at their facility, went into high voltage testing, including Paschen testing in the vacuum, and then they were tested at 4.5 K and up to 40 kA to demonstrate compliance of the coil with the ITER requirements. In this article, we present the Test Plan and results of the central solenoid (CS) module’s performance, especially at the full current. We measured critical temperatures in several pancakes, we measured ac losses, joint resistance, and hydraulic characteristics of the coils. We also measured displacements of the coil height and hoop strain of the CS module (CSM) to verify the structural mechanical characteristics of the coil along with the cooldown shrinkage of the coil. We studied the performance of the cowound quench detectors and confirmed their effectiveness in the suppression of inductive noise. This information is necessary for verification of the stack behavior of CS in ITER operation. The test results and preliminary analyses are presented, compared to expectations, and discussed.

Martovetsky, Nicolai↗

Separation of Frequency and Amplitude Modulation Contributions Due to External Vibration on a SAW Resonator

Surface SAW resonators (SAWR) are widely used in radio-frequency (RF) communications, frequency-control, and sensing applications. External vibration-induced modulations of a SAWR’s RF response can be detrimental in communications and frequency-control as it generates undesired spurious signals and unwanted phase noise. In sensing applications, vibration-induced response can either be a primary measurand or an undesired spurious signal that reduces sensor accuracy and precision. Therefore, characterization of vibration-induced modulations is important to improve device performance in all the applications listed above. This paper presents an in-phase and quadrature signal analysis technique to demodulate a SAWR RF signal exposed to external vibrations and separate the contributions of amplitude modulation (AM) and frequency modulation (FM). A SAWR was mounted in a cantilever configuration and exposed to external mechanical vibrating signals using a vibration generator. The SAWR was excited close to its resonant frequency using a RF synthesizer and its echo response was measured using a vector signal analyzer. The experimental results and findings reported in this paper confirm that the I-Q analysis developed in this work is effective not only to determine the frequency and spectral amplitude of a mechanical vibrating signal on a SAWR, but also to separate the AM and FM contributions. Here, this analysis contributes to the quantification and understanding of induced external vibrations on SAWRs used in contemporary communications, frequency control, and sensing applications.

42 ENGINEERING↗

Methane detection of chirped laser dispersion spectroscopy using DSB-SC modulation

This paper discusses the use of double-sideband suppressed-carrier (DSB-SC) modulation and radio frequency mixer as phase detector to extract phase information for methane detection in chirped laser dispersion spectroscopy (CLaDS). The 1.66 μm light from narrow-linewidth laser was modulated by electro-optic modulator (EOM) working on DSB-SC mode. These two sidebands passed through gas chamber and formed interference on photodetector. The phase change from gas absorption in beating signal can be extracted by using passive RF mixer with another input as reference signal which is achieved by doubling RF drive signal of EOM. In RF mixer, two inputs with identical frequency but various phase shift corresponds to DC bias voltage variation of output. The phase change is proportional to refractive index change and can be referred to gas concentration by using Kramers-Kronig relations. The advantage of phase sensitive CLaDS is wide dynamic range for gas detection. It compensates the deficiency of wavelength modulation spectroscopy (WMS) on high concentration circumstances. And the passive scheme pushes the system requirement to the lowest level.

Peng, Zhaoqiang↗

SU-E-J-254: Utility of Pinnacle Dynamic Planning Module Utilizing Deformable Image Registration in Adaptive Radiotherapy

Purpose For certain highly conformal treatment techniques, changes in patient anatomy due to weight loss and/or tumor shrinkage can result in significant changes in dose distribution. Recently, the Pinnacle treatment planning system added a Dynamic Planning module utilizing Deformable Image Registration (DIR). The objective of this study was to evaluate the effectiveness of this software in adapting to altered anatomy and adjusting treatment plans to account for it. Methods We simulated significant tumor response by changing patient thickness and altered chin positions using a commercially-available head and neck (H and N) phantom. In addition, we studied 23 CT image sets of fifteen (15) patients with H and N tumors and eight (8) patients with prostate cancer. In each case, we applied deformable image registration through Dynamic Planning module of our Pinnacle Treatment Planning System. The dose distribution of the original CT image set was compared to the newly computed dose without altering any treatment parameter. Result was a dose if we did not adjust the plan to reflect anatomical changes. Results For the H and N phantom, a tumor response of up to 3.5 cm was correctly deformed by the Pinnacle Dynamic module. Recomputed isodose contours on new anatomies were within 1 mm of the expected distribution. The Pinnacle system configuration allowed dose computations resulting from original plans on new anatomies without leaving the planning system. Original and new doses were available side-by-side with both CT image sets. Based on DIR, about 75% of H and N patients (11/15) required a re-plan using new anatomy. Among prostate patients, the DIR predicted near-correct bladder volume in 62% of the patients (5/8). Conclusions The Dynamic Planning module of the Pinnacle system proved to be an accurate and useful tool in our ability to adapt to changes in patient anatomy during a course of radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-568: Improving Normal Brain Sparing with Increasing Number of Arc Beams for Volume Modulated Arc Beam Radiosurgery of Multiple Brain Metastases

Purpose: Intensity modulated arc beams have been newly reported for treating multiple brain metastases. The purpose of this study was to determine the variations in the normal brain doses with increasing number of arc beams for multiple brain metastases treatments via the TrueBeam Rapidarc system (Varian Oncology, Palo Alto, CA). Methods: A patient case with 12 metastatic brain lesions previously treated on the Leksell Gamma Knife Perfexion (GK) was used for the study. All lesions and organs at risk were contoured by a senior radiation oncologist and treatment plans for a subset of 3, 6, 9 and all 12 targets were developed for the TrueBeam Rapidarc system via 3 to 7 intensity modulated arc-beams with each target covered by at least 99% of the prescribed dose of 20 Gy. The peripheral normal brain isodose volumes as well as the total beam-on time were analyzed with increasing number of arc beams for these targets. Results: All intensisty modulated arc-beam plans produced efficient treatment delivery with the beam-on time averaging 0.6–1.5 min per lesion at an output of 1200 MU/min. With increasing number of arc beams, the peripheral normal brain isodose volumes such as the 12-Gy isodose line enclosed normal brain tissue volumes were on average decreased by 6%, 11%, 18%, and 28% for the 3-, 6-, 9-, 12-target treatment plans respectively. The lowest normal brain isodose volumes were consistently found for the 7-arc treatment plans for all the cases. Conclusion: With nearly identical beam-on times, the peripheral normal brain dose was notably decreased when the total number of intensity modulated arc beams was increased when treating multiple brain metastases. Dr Sahgal and Dr Ma are currently serving on the board of international society of stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-04: Dosimetric Evaluation of a Modulated Arc Technique for Total Body Irradiation

Purpose: A simplified Total Body Irradiation (TBI) was developed to work with minimal requirements in a compact linac room without custom motorized TBI couch. Results were compared to our existing fixed-gantry double 4 MV linac TBI system with prone patient and simultaneous AP/PA irradiation. Methods: Modulated arc irradiates patient positioned in prone/supine positions along the craniocaudal axis. A simplified inverse planning method developed to optimize dose rate as a function of gantry angle for various patient sizes without the need of graphical 3D treatment planning system. This method can be easily adapted and used with minimal resources. Fixed maximum field size (40×40 cm2) is used to decrease radiation delivery time. Dose rate as a function of gantry angle is optimized to result in uniform dose inside rectangular phantoms of various sizes and a custom VMAT DICOM plans were generated using a DICOM editor tool. Monte Carlo simulations, film and ionization chamber dosimetry for various setups were used to derive and test an extended SSD beam model based on PDD/OAR profiles for Varian 6EX/ TX. Measurements were obtained using solid water phantoms. Dose rate modulation function was determined for various size patients (100cm − 200cm). Depending on the size of the patient arc range varied from 100° to 120°. Results: A PDD/OAR based beam model for modulated arc TBI therapy was developed. Lateral dose profiles produced were similar to profiles of our existing TBI facility. Calculated delivery time and full arc depended on the size of the patient (∼8min/ 100° − 10min/ 120°, 100 cGy). Dose heterogeneity varied by about ±5% − ±10% depending on the patient size and distance to the surface (buildup region). Conclusion: TBI using simplified modulated arc along craniocaudal axis of different size patients positioned on the floor can be achieved without graphical / inverse 3D planning.

60 APPLIED LIFE SCIENCES↗

Characterization and implementation of OSL dosimeters for use in evaluating the efficacy of organ-based tube current modulation for CT scans of the face and orbits

Purpose: The purpose of this work was to characterize commercially available optically stimulated luminescent (OSL) dosimeters for general clinical applications and apply the results to the development of a method to evaluate the efficacy of a vendor-specific organ-based tube current modulation application for both phantom and clinical computed tomography (CT) scans of the face and orbits. Methods: This study consisted of three components: (1) thorough characterization of the dosimeters for CT scans in phantom, including evaluations of depletion, fading, angular dependence, and conversion from counts to absorbed dose; (2) evaluation of the efficacy of using plastic glasses to position the dosimeters over the eyes in both phantom and clinical studies; and (3) preliminary dosimetry measurements made using organ-based tube current modulation in computed tomography dose index (CTDI) and anthropomorphic phantom studies. Results: (1) Depletion effects were found to have a linear relationship with the output of the OSL dosimeters (R{sup 2} = 0.96). Fading was found to affect dosimeter readings during the first two hours following exposure but had no effect during the remaining 60-h period observed. No significant angular dependence was observed for the exposure conditions used in this study (with p-values ranging from 0.9 to 0.26 for all t-tests). Dosimeter counts varied linearly with absorbed dose when measured in the center and 12 o’clock positions of the CTDI phantoms. These linear models of counts versus absorbed dose had overlapping 95% confidence intervals for the intercepts but not for the slopes. (2) When dosimeters were positioned using safety glasses, there was no adverse effect on image quality, and there was no statistically significant difference between this placement and placement of the dosimeters directly on the eyes of the phantom (p = 0.24). (3) When using organ-based tube current modulation, the dose to the lens of the eye was reduced between 19% and 43%, depending on the scan protocol used and the positioning of the phantom. Furthermore, the amount of dose reduction was significantly affected by the vertical position of the phantom, with the largest reduction in dose seen when the phantom was centered in the gantry. Conclusions: (1) An appropriate correction factor, specific to CT scanning, was developed to account for depletion and fading characteristics of the dosimeters. Additionally, an equation to convert dosimeter counts to absorbed dose was established. (2) The use of plastic safety glasses was validated as an appropriate positioning device when measuring dose to the lens of the eye. (3) The use of organ-based tube current modulation can reduce dose to the lens of the eye during CT scanning. The amount of dose reduction, however, is largely influenced by the positioning of the anatomy in the gantry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Creation of an atlas of filter positions for fluence field modulated CT

Purpose: Fluence field modulated CT (FFMCT) and volume of interest (VOI) CT imaging applications require adjustment of the profile of the x-ray fluence incident on a patient as a function of view angle. Since current FFMCT prototypes can theoretically take on an infinite number of configurations, measuring a calibration data set for all possible positions would not be feasible. The present work details a methodology for calculating an atlas of configurations that will span all likely body regions, patient sizes, patient positioning, and imaging modes. The hypothesis is that there exists a finite number of unique modulator configurations that effectively span the infinite number of possible fluence profiles with minimal loss in performance. Methods: CT images of a head, shoulder, thorax, abdominal, wrist, and leg anatomical slices were dilated and contracted to model small, medium, and large sized patients. Additionally, the images were positioned from iso-center by three different amounts. The modulator configurations required to compensate for each image were computed assuming a FFMCT prototype, digital beam attenuator, (DBA), was set to equalize the detector exposure. Each atlas configuration should be different from the other atlas configurations. The degree of difference was quantified using the sum of the absolute differences in filter thickness between configurations. Using this metric, a set of unique wedge configurations for which no two configurations have a metric value smaller than some threshold can be constructed. Differences in the total number of incident photons between the unconstrained filters and the atlas were studied as a function of the number of atlas positions for each anatomical site and size/off-centering combination. Results: By varying the threshold used in creating the atlas, it was found that roughly 322 atlas positions provided an incident number of photons within 20% of using 19 440 unique filters (the number of atlas entries ranged from 7213 to 1). Additionally, for VOI applications implemented with a single VOI region, the number of required filter configurations was expressed in a simple closed form solution. Conclusions: The methodology proposed in this work will enable DBA-FFMCT and DBA-VOI imaging in the clinic without the need for patient specific air-scans to be performed. In addition, the methodology proposed here is directly applicable to other modulator designs such as piecewise linear, TomoTherapy multi leaf collimators, 2D fluid arrays, and inverse geometry CT.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-11: Development of a Nuclear Medicine Dosimetry Module for the GPU-Based Monte Carlo Code ARCHER

Purpose: To develop a nuclear medicine dosimetry module for the GPU-based Monte Carlo code ARCHER. Methods: We have developed a nuclear medicine dosimetry module for the fast Monte Carlo code ARCHER. The coupled electron-photon Monte Carlo transport kernel included in ARCHER is built upon the Dose Planning Method code (DPM). The developed module manages the radioactive decay simulation by consecutively tracking several types of radiation on a per disintegration basis using the statistical sampling method. Optimization techniques such as persistent threads and prefetching are studied and implemented. The developed module is verified against the VIDA code, which is based on Geant4 toolkit and has previously been verified against OLINDA/EXM. A voxelized geometry is used in the preliminary test: a sphere made of ICRP soft tissue is surrounded by a box filled with water. Uniform activity distribution of I-131 is assumed in the sphere. Results: The self-absorption dose factors (mGy/MBqs) of the sphere with varying diameters are calculated by ARCHER and VIDA respectively. ARCHER’s result is in agreement with VIDA’s that are obtained from a previous publication. VIDA takes hours of CPU time to finish the computation, while it takes ARCHER 4.31 seconds for the 12.4-cm uniform activity sphere case. For a fairer CPU-GPU comparison, more effort will be made to eliminate the algorithmic differences. Conclusion: The coupled electron-photon Monte Carlo code ARCHER has been extended to radioactive decay simulation for nuclear medicine dosimetry. The developed code exhibits good performance in our preliminary test. The GPU-based Monte Carlo code is developed with grant support from the National Institute of Biomedical Imaging and Bioengineering through an R01 grant (R01EB015478)

60 APPLIED LIFE SCIENCES↗

SU-F-T-209: Multicriteria Optimization Algorithm for Intensity Modulated Radiation Therapy Using Pencil Proton Beam Scanning

Purpose: To provide a multicriteria optimization algorithm for intensity modulated radiation therapy using pencil proton beam scanning. Methods: Intensity modulated radiation therapy using pencil proton beam scanning requires efficient optimization algorithms to overcome the uncertainties in the Bragg peaks locations. This work is focused on optimization algorithms that are based on Monte Carlo simulation of the treatment planning and use the weights and the dose volume histogram (DVH) control points to steer toward desired plans. The proton beam treatment planning process based on single objective optimization (representing a weighted sum of multiple objectives) usually leads to time-consuming iterations involving treatment planning team members. We proved a time efficient multicriteria optimization algorithm that is developed to run on NVIDIA GPU (Graphical Processing Units) cluster. The multicriteria optimization algorithm running time benefits from up-sampling of the CT voxel size of the calculations without loss of fidelity. Results: We will present preliminary results of Multicriteria optimization for intensity modulated proton therapy based on DVH control points. The results will show optimization results of a phantom case and a brain tumor case. Conclusion: The multicriteria optimization of the intensity modulated radiation therapy using pencil proton beam scanning provides a novel tool for treatment planning. Work support by a grant from Varian Inc.

60 APPLIED LIFE SCIENCES↗

Structural basis for histone H2B deubiquitination by the SAGA DUB module

Monoubiquitinated histone H2B plays multiple roles in transcription activation. H2B is deubiquitinated by the Spt-Ada-Gcn5 acetyltransferase (SAGA) coactivator, which contains a four-protein subcomplex known as the deubiquitinating (DUB) module. In this paper, the crystal structure of the Ubp8/Sgf11/Sus1/Sgf73 DUB module bound to a ubiquitinated nucleosome reveals that the DUB module primarily contacts H2A/H2B, with an arginine cluster on the Sgf11 zinc finger domain docking on the conserved H2A/H2B acidic patch. The Ubp8 catalytic domain mediates additional contacts with H2B, as well as with the conjugated ubiquitin. Finally, we find that the DUB module deubiquitinates H2B both in the context of the nucleosome and in H2A/H2B dimers complexed with the histone chaperone, FACT, suggesting that SAGA could target H2B at multiple stages of nucleosome disassembly and reassembly during transcription.

59 BASIC BIOLOGICAL SCIENCES↗