High critical currents in heavily doped (Gd,Y)Ba 2 Cu 3 O x superconductor tapes

REBa 2 Cu 3 O x superconductor tapes with moderate levels of dopants have been optimized for high critical current density in low magnetic fields at 77 K, but they do not exhibit exemplary performance in conditions of interest for practical applications, i.e., temperatures less than 50 K and fields of 2–30 T. Heavy doping of REBCO tapes has been avoided by researchers thus far due to deterioration in properties. Here, we report achievement of critical current densities (J c ) above 20 MA/cm 2 at 30 K, 3 T in heavily doped (25 mol. % Zr-added) (Gd,Y)Ba 2 Cu 3 O x superconductor tapes, which is more than three times higher than the J c typically obtained in moderately doped tapes. Pinning force levels above 1000 GN/m 3 have also been attained at 20 K. A composition map of lift factor in J c (ratio of J c at 30 K, 3 T to the J c at 77 K, 0 T) has been developed which reveals the optimum film composition to obtain lift factors above six, which is thrice the typical value. A highly c-axis aligned BaZrO 3 (BZO) nanocolumn defect density of nearly 7 × 10 11 cm –2 as well as 2–3nm sized particles rich in Cu and Zr have been found in the high J c films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fractal analysis for assessing the level of modulation of IMRT fields

Purpose: To investigate the potential of three fractal dimension (FD) analysis methods (i.e., the variation, power spectrum, and variogram methods) as metrics for quantifying the degree of modulation in planned intensity modulated radiation therapy (IMRT) treatment fields, and compare the most suitable FD method to the number of monitor units (MUs), the average leaf gap, and the 2D modulation index (2D MI) for assessing modulation. Methods: The authors implemented, validated, and compared the variation, power spectrum, and variogram methods for computing the FD. Validation of the methods was done using mathematical fractional Brownian surfaces of known FD that ranged in size from 128 x 128 to 512 x 512. The authors used a test set consisting of seven head and neck carcinoma plans (50 prescribed treatment fields) to choose an FD cut-point that ensures no false positives (100% specificity) in distinguishing between moderate and high degrees of field modulation. The degree of field modulation was controlled by adjusting the fluence smoothing parameters in the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). The moderate modulation fields were representative of the degree of modulation used clinically at the authors' institution. The authors performed IMRT quality assurance (QA) on the 50 test fields using the MapCHECK device. The FD cut-point was applied to a validation set consisting of four head and neck plans (28 fields). The area under the curve (AUC) from receiver operating characteristic (ROC) analysis was used to compare the ability of FD, number of MUs, average leaf gap, and the 2D MI for distinguishing between the moderate and high modulation fields. Results: The authors found the variogram FD method to be the most suitable for assessing the modulation complexity of IMRT fields for head and neck carcinomas. Pass rates as measured by the gamma criterion for the MapCHECK IMRT field measurements were higher for the moderately modulated fields, and a gamma criterion with 1 mm distance-to-agreement and 1% dose difference showed a clear separation between the 94% pass rates of the moderate and high modulation groups. From the ROC analysis of the test set, the authors found the AUC of the variogram FD, number of MUs, average leaf gap, and 2D MI methods to be 0.99 (almost perfect), 0.91 (excellent), 0.91 (excellent), and 0.92 (excellent), respectively. A cut-point of FD > 2.25 correctly identified 92.8% of the high modulation fields and 100% of the moderately modulated fields in the validation set, satisfying the condition of no false positives. Conclusions: Of the three FD methods investigated, the variogram method is the most accurate and precise metric for identifying high modulation treatment fields. It is also more accurate and precise than the number of MUs, the average leaf gap, and the 2D MI. Although MapCHECK IMRT QA does a reasonable job at identifying high modulation fields, the variogram FD method provides one with the opportunity to quantitatively and accurately assess modulation and adjust overly modulated fields at the treatment planning stage before they are sent to the treatment machine for QA or patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-766: Treatment Planning Comparison Study On Two Different Multileaf Collimators Delivered with Volumetric Modulated Arc Therapy

Purpose: To compare and evaluate the performance of two different multileaf collimators(MLCi2 and Agility) delivery with volumetric modulated arc therapy techniques. Methods: Treatment plans were graded four (Low, Moderate, Moderate-High and High complexity) accorrding to the complexity. This includes 1 Low complexity(brain metastasis), 2 Moderate complexity(Lung and Liver), 1 Moderate-High complexity(prostate) and 1 High complexity ( head and neck) cases. Total dose of 60 Gy was given for all the plans. All cases were desigined two VMAT plans, one with MLCi2(group A) and the other with Agility(group B). All plans were done on Elekta VMAT with Monaco treatment planning system. All plans were generated with 6 MV X-rays for both Plan A and Plan B. Plans were evaluated based on the ability to meet the dose volume histogram, radiation conformity index, estimated radiation delivery time, dose homogeneity index(HI) and monitor units(MU) needed to deliver the prescribed dose. Results: Plans of group B achieved the best HI (HI = 1.05 Vs. 1.06) at the Low complexity cases while plans of group A were slightly better at the high complexity cases (HI = 1.12 Vs. 1.14). Faster VMAT plan delivery with Agility than with MLCi2 as plan complexity increased (Low complexity:52s Vs.52s, Moderate complexity:58s Vs. 55s, Moderate-High complexity: 171s Vs.152s, High complexity : 326s Vs. 202s ), especially for the most complex paradigms delivered time can be decresed 38%. No Significant changes were observed between the group B and group A plans in terms of the healthy tissue mean dose and MU. Both plans respected the planning objective for all organs at risk. Conclusion: The study concludes that VMAT plans with the novel Agility MLC can significant decrease the delivering time at the high complexity cases, while a slight compromise in the dose homogeneity index should be noted. This work was supported by The Medical Science Foundation of The health department of Hebei Province (No. 20130253)

60 APPLIED LIFE SCIENCES↗

Comparison of the Neutronic Performance of IRP-1 and IRP-2 at SNS

The Spallation Neutron Source (SNS) operated from start-up, in May 2006, through December, 2017 before replacing the Inner Reflector Plug (IRP). This component is the most costly and time-consuming “regular maintenance” replacement foreseen in the operation of the First Target Station (FTS). The IRP includes beryllium reflector blocks, steel and aluminum support structures, aluminum moderator vessels (which in turn include gadolinium and cadmium neutron poisons) and water coolant systems. The lifetime of this multi-million dollar component is driven by poison and decoupler burnup in moderator vessels. The moderators include these neutron poisons to best match neutron beam performance with scattering instrument needs. The burnup that comes with use changes the performance of the moderators until they no longer server their intended purpose. The reasonable desire to maximize the IRP lifetime means that the moderator performance at the Beginning Of Life (BOL) is significantly “over poisoned” and different from the performance at moderator End Of Life (EOL). Upon installation of the second IRP article, IRP-2, the SNS Neutronics team characterized the performance of the neutron beamlines in order to assess the differences between them, primarily by comparing the EOL performance of IRP-1 to the BOL performance of IRP-2. While IRP-2 was largely similar to IRP-1 in its conceptual design, there were some differences in the specific design of IRP-2 to support enhanced manufacturability, and the change from IPR-1 to IRP-2 coincided with the replacement of the light water in the IRP cooling loop with heavy water, as had been intended in the SNS design but not implemented during construction because of heavy water availability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Chloride Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

Uranium electrorefining operations at Y-12 require validation for chlorine absorption and reflection. Plutonium chloride solution operations at Los Alamos National Laboratory require chlorine absorption validation. The growing need for chlorine validation is evident to the wider criticality safety community, with multiple attendees at the recent TEX 2.0 meeting at Lawrence Livermore National Laboratory (May 2023) requesting validation for chlorine (Idaho National Laboratory (INL), Institute de radioprotection et de surete nucleaire (IRSN), Savannah River Nuclear Site (SRNS), LANL, and Y-12). Los Alamos National Laboratory has recently performed, and benchmarked, an experiment titled Chlorine Worth Study (CWS) for the internal operations at the lab, but due to the difficulties in precisely characterizing the material compositions of the chlorine absorbers it is advantageous to perform a complimentary study with a different chlorine-based absorber material. Furthermore, having a uranium-based vs plutonium-based experiment provides a separate and important validation basis for criticality safety and nuclear data evaluation. The original final design report for the study of chlorine absorption using the TEX-HEU experimental base was presented in 2022, but used the same chlorine-bearing materials that were found to be difficult to characterize in the LANL benchmark. A complete redesign of the experiment has been performed looking at alternative absorber materials in various forms to produce an experiment that is fully characterizable. This report presents five novel chlorine experiments using the TEX-HEU test bed which provides direct comparison to the Y-12 and INL/Terrapower application needs, utilizing sodium chloride (NaCl) absorber plates. The absorber plates will consist of granulated NaCl (≥99.5% pure), which will be fully encapsulated in aluminum tins, providing a simple but effective chlorine-based absorber material that can be completely characterized. Of the five configurations presented in this report, it is expected that two or three configurations will be down selected for the actual experiment, with the other configurations being alternates. Three of the configurations are in the standard configuration, where the absorber is placed directly on the HEU fuel plates, and two in the sandwich configuration, where the absorber is surrounded by polyethylene moderators to force additional neutron thermalization prior to reaching the absorber. There are two thicknesses of NaCl absorber plates: 3/16” and 1/4” active thicknesses (i.e. not including the encapsulation). Both variations of the absorbers have an active absorber radius of 6” and a total radius of 7.5” to match the diameter of the HEU plates, with the outer 1.5” being aluminum encapsulation. The high-density polyethylene (HDPE) moderators are of the thicknesses: 27/16”, 7/4”, 1/8”, 11/16”, and 3/4”. The final configurations have six (one sandwich and one standard configuration), eight (one sandwich and one standard configuration), and 18 total fuel layers (standard configuration). The standard and sandwich configurations were designed such that the differences in moderator thicknesses are 1” HDPE, which were already procured for the original CED-2. The proposed configurations were precisely tuned to closely match the sensitivity profiles and neutron spectra of the Y-12 upset cases and were also compared to the INL/Terrapower upset cases. The assessment of experimental uncertainties of the non-absorber components was predicted to be 0.00114 Δk eff . The assessment of uncertainties resulting from the absorbers was predicted to be 0.00029 Δk eff . This results in a total uncertainty of 0.00118 Δk eff . Many of the largest uncertainties, namely the moderator densities, may be reduced with precision dimensional inspection of the components. The 1” HDPE moderators as well as the HDPE reflectors from the original CED-2 were incorporated in the final designs presented here. Additional HDPE moderator plates must be fabricated to complete the configurations. NaCl absorber plates will by fabricated at LLNL. The total additional cost is expected to be $\$$54,250 for the remaining components. Precise inspection, including dimensional, mass, density, and impurity, is recommended for all components. LLNL estimates that these costs are around $\$$12,000. It is expected, based on previous TEX-HEU experiments, that three weeks of experimental facility time is needed to complete the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A radar-echo model for Mars

Researchers developed a radar-echo model for Mars based on 12.6 cm continuous wave radio transmissions backscattered from the planet. The model broadly matches the variations in depolarized and polarized total radar cross sections with longitude observed by Goldstone in 1986 along 7 degrees S. and yields echo spectra that are generally similiar to the observed spectra. Radar map units in the model include an extensive cratered uplands unit with weak depolarized echo cross sections, average thermal inertias, moderate normal refelectivities, and moderate rms slopes; the volcanic units of Tharsis, Elysium, and Amazonis regions with strong depolarized echo cross sections, low thermal inertia, low normal reflectivities, and large rms slopes; and the northern planes units with moderate to strong depolarized echo cross sections, moderate to very high thermal inertias, moderate to large normal reflectivities, and moderate rms slopes. The relevance of the model to the interpretation of radar echoes from Mars is discussed.

Thompson, T. W.↗

Some Nuclear Calculations of U-235-D2O Gaseous-Core Cavity Reactors

The results of a multigroup, diffusion theory study of spherical gaseous-core cavity reactors are presented in this report. The reactor cavity of gaseous U235 is enclosed by a region of hydrogen gas and is separated from an external D2O moderator-reflector by a zirconium structural shell. Some cylindrical reactors are also investigated. A parametric study of spherical reactors indicates that, for the range of variables studied, critical mass increases as: (1) Fuel region is compressed within the reactor cavity, (2) moderator thickness is decreased, (3) structural shell thickness is increased, and (4) moderator temperature is increased. A buckling analogy is used to estimate the critical mass of fully reflected cylindrical reactors from spherical results without fuel compression. For a reactor cavity of a 120-centimeter radius uniformly filled with fuel, no structural shell, a moderator temperature of 70 F, and a moderator thickness of 100 centimeters, the critical mass of a spherical reactor is 3.1 kilograms while that of a cylinder with a length-to-diameter ratio of 1.0 (L/D = 1) is approximately 3.8 kilograms and, with L/D = 2, 5.9 kilograms. For the range of variables considered for U235-D2O gaseous-core cavity reactors, the systems are characterized by 95 to 99 percent thermal absorptions, with the flux reaching a maximum in the moderator about 10 to 15 centimeters from the reactor cavity.

Ragsdale, Robert G.↗

Which parameters might help to predict an impact on reactivity for mixed fissile units in a storage array?

Several studies have already been performed on mixed fissile units in storage arrays and concluded that the neutron spectrum of the fissile material, the shape of fissile units, the interstitial moderation and structural materials may have an impact on reactivity. For this paper, calculations are performed on a simplified infinite planar array with one level of fissile material units axially reflected by concrete. Fissile material is modelled by a cylinder shape centered in the array mesh selected (120 cm height and 60 cm pitch). Either air or interstitial moderation by water is modelled between the fissile units. Three parameters are studied: the fissile materials (with various moderation conditions), the cylinder dimension and the nature of the structural material. The main following conclusions can be drawn from these calculations. First, for several mixed-array cases, air-spaced mixed arrays present a high increase on reactivity whereas interstitial moderation between fissile units leads to no or little impact. Secondly, fissile unit shapes do not explain directly the mixing impact on reactivity. Thirdly, structural materials have an important impact on reactivity in mixed array (either an increase or a decrease) due to their absorbing and/or moderating properties either when air or interstitial moderation are modelled between fissile units. Fourthly, no simple parameter was found to predict the impact on reactivity of mixed array in all studied configurations. However, a comparison of different neutron spectrum parameters can help to predict the absence or potential presence of a 'mixing effect'. Indeed, if all parameters are similar, no 'mixing effect' is observed. But, if these parameters present differences, there might be a 'mixing effect'. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-132: Assess the Shielding of Secondary Neutrons From Patient Collimator in Proton Therapy Considering Secondary Photons Generated in the Shielding Process with Monte Carlo Simulation

Purpose: In this study we present Monte Carlo based evaluation of the shielding effect for secondary neutrons from patient collimator, and secondary photons emitted in the process of neutron shielding by combination of moderator and boron-10 placed around patient collimator. Methods: The PHITS Monte Carlo Simulation radiation transport code was used to simulate the proton beam (Ep = 64 to 93 MeV) from a proton therapy facility. In this study, moderators (water, polyethylene and paraffin) and boron (pure {sup 10}B) were placed around patient collimator in this order. The rate of moderator and boron thicknesses was changed fixing the total thickness at 3cm. The secondary neutron and photons doses were evaluated as the ambient dose equivalent per absorbed dose [H*(10)/D]. Results: The secondary neutrons are shielded more effectively by combination moderators and boron. The most effective combination of shielding neutrons is the polyethylene of 2.4 cm thick and the boron of 0.6 cm thick and the maximum reduction rate is 47.3 %. The H*(10)/D of secondary photons in the control case is less than that of neutrons by two orders of magnitude and the maximum increase of secondary photons is 1.0 µSv/Gy with the polyethylene of 2.8 cm thick and the boron of 0.2 cm thick. Conclusion: The combination of moderators and boron is beneficial for shielding secondary neutrons. Both the secondary photons of control and those emitted in the shielding neutrons are very lower than the secondary neutrons and photon has low RBE in comparison with neutron. Therefore the secondary photons can be ignored in the shielding neutrons.This work was supported by JSPS Core-to-Core Program (No.23003). This work was supported by JSPS Core-to-Core Program (No.23003)

60 APPLIED LIFE SCIENCES↗

Effects of Nitric Acid on Criticality Safety Analysis

As nitric acid molarity is increased, there are two competing phenomena affecting the reactivity of the system. First, there is interaction between each of the 10 wells in the basket-like insert. As the molarity of the nitric acid solution is increased (it moves from 100% water to 100% HNO 3 ), the hydrogen atom density decreases by about 80%. However, it remains a relatively efficient moderator. The moderating ratio of nitric acid is about 90% that of water. As the media between the wells is changed from 100% water to 100% nitric acid, the density of the media increases by 50%. A higher density typically leads to a better reflector. However, when the macroscopic scattering cross sections are considered, nitric acid is a much worse reflector than water. The effectiveness of nitric acid as a reflector is about 40% that of water. Since the media between the wells become a worse reflector and still remains an effective moderator, interaction between the wells increases. This phenomenon will cause reactivity to increase as nitric acid molarity increases. The second phenomenon is due to the moderating ratio changing in the high concentration fissile-nitric acid solution in the 10 wells. Since the wells contain relatively small volumes of high concentration solutions, a small decrease in moderating power has a large effect on reactivity. This is due to the fact that neutrons are more likely to escape the high concentration fissile solution before causing another fission event. The result of this phenomenon is that as nitric acid molarity increases, reactivity decreases. Recent studies have shown that the second phenomenon is indeed the dominating force in determining reactivity changes in relation to nitric acid molarity changes. When considering the system as a whole, as nitric acid molarity increases, reactivity decreases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of the MTC noise estimation with a coupled neutronic/thermal-hydraulic dedicated model - 'Closing the loop'

This paper investigates the reliability of different noise estimators aimed at determining the Moderator Temperature Coefficient (MTC) of reactivity in Pressurized Water Reactors. By monitoring the inherent fluctuations in the neutron flux and moderator temperature, an on-line monitoring of the MTC without perturbing reactor operation is possible. In order to get an accurate estimation of the MTC by noise analysis, the point-kinetic component of the neutron noise and the core-averaged moderator temperature noise have to be used. Because of the scarcity of the in-core instrumentation, the determination of these quantities is difficult, and several possibilities thus exist for estimating the MTC by noise analysis. Furthermore, the effect of feedback has to be negligible at the frequency chosen for estimating the MTC in order to get a proper determination of the MTC. By using an integrated neutronic/thermal- hydraulic model specifically developed for estimating the three-dimensional distributions of the fluctuations in neutron flux, moderator properties, and fuel temperature, different approaches for estimating the MTC by noise analysis can be tested individually. It is demonstrated that a reliable MTC estimation can only be provided if the core is equipped with a sufficient number of both neutron detectors and temperature sensors, i.e. if the core contain in-core detectors monitoring both the axial and radial distributions of the fluctuations in neutron flux and moderator temperature. It is further proven that the effect of feedback is negligible for frequencies higher than 0.1 Hz, and thus the MTC noise estimations have to be performed at higher frequencies. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Adjusted Graphite Thermal Scattering Data Applied to Fluoride-Salt-Cooled Reactors

Thermal scattering data is a key component of fission reactor simulation. While most materials can be reasonably modeled with a free gas approximation, the moderators in thermal systems require a more rigorous treatment to sufficiently capture their specific neutron interaction physics. Graphite does not typically feature as a principle moderator in power reactors in service today, but remains an attractive prospect for a number of new reactor concepts currently in development. In comparison to light water, a material nearly ubiquitous in thermal reactors, graphite offers a better neutron economy by way of a small absorption cross section, high thermodynamic stability and can be incorporated into the structure of the core itself. Graphite in its purest form is a crystalline material composed of stacked layers of graphene, a hexagonal planar lattice of carbon atoms. In-plane, each carbon atom is covalently bonded to 3 neighbouring carbon atoms, creating a strong bond, while between planes only a weak van der Waals force exists. Pure graphite has a density of 2.26 g/cm{sup 3}. However, reactor-grade contains a significant amount of carbon binder, leading to a porous bulk medium with randomly oriented micro crystals. Densities of 1.5 - 1.9 g/cm{sup 3} are typical for reactor-grade graphite, corresponding to porosities on the order of 10-30%. This deviation from pure crystalline graphite should be accounted for in the thermal scattering data. When an incident neutron is in or near the thermal region, its de Broglie wavelength is the same order as the molecular bond lengths, leading to elastic scattering. At similar energies, the dynamics of the moderator lattice (in the case of solid moderators) can cause inelastic scattering. For these moderators, special cross sections should be calculated and used in reactor simulations. To generate this thermal scattering data, parameters pertaining to the properties and structure of the material in question are fed into a nuclear data processing code, such as NJOY. Within NJOY is a module called LEAPR which is used to generate the thermal scattering law S(α,β), which is in turn is fed into another module THERMR which is used to generate thermal cross sections that factor in the molecular-scale scattering phenomena. The core of the thermal scattering law is the phonon spectrum ρ(β) which describes the modes of excitation of the material lattice. An investigation into the phonon frequency spectrum was conducted at North Carolina State University (NCSU) for reactor-grade graphite which accounts for porosity. This phonon spectrum was calculated using the ab initio density functional theory (DFT) code VASP. The inelastic cross section calculated using this spectrum was found to have good agreement with relevant experimental data. The resulting spectra differed from the benchmark spectrum produced by Young and Koppel, the same data used in current nuclear data evaluations. The latter uses the lattice dynamics of perfect crystalline graphite with four force constants fitted to the model from thermodynamics data from reactor-grade (porous) graphite, which yields a reasonable approximation to the phonon spectrum of reactor-grade graphite.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Provider-Assessed and Patient-Reported Outcome Measures of Acute Skin Toxicity During a Phase III Trial of Mometasone Cream Versus Placebo During Breast Radiotherapy: The North Central Cancer Treatment Group (N06C4)

Purpose: Considerable interobserver variability exists among providers and between providers and patients when measuring subjective symptoms. In the recently published Phase III N06C4 trial of mometasone cream vs. placebo to prevent radiation dermatitis, the primary provider-assessed (PA) endpoint, using the Common Toxicity Criteria for Adverse Events (CTCAE), was negative. However, prospectively planned secondary analyses of patient-reported outcomes (PROs), using the Skindex-16 and Skin Toxicity Assessment Tool (STAT), were positive. This study assesses the relationship between PA outcomes and PROs. Methods and Materials: Pearson correlation coefficients were calculated to compare the three tools. Statistical correlations were defined as follows: <0.5, mild; 0.5-0.7, moderate; and >0.7, strong. Results: CTCAE dermatitis moderately correlated with STAT erythema, and CTCAE pruritus strongly correlated with STAT itching. CTCAE pruritus had a moderate correlation with Skindex-16 itching. Comparing the 2 PRO tools, Skindex-16 itching correlated moderately with STAT itching. Skindex-16 burning, hurting, irritation, and persistence all showed the strongest correlation with STAT burning; they showed moderate correlations with STAT itching and tenderness. Conclusions: The PRO Skindex-16 correlated well with the PRO portions of STAT, but neither tool correlated well with CTCAE. PROs delineated a wider spectrum of toxicity than PA measures and provided more information on rash, redness, pruritus, and annoyance measures compared with CTCAE findings of rash and pruritus. PROs may provide a more complete measure of patient experience than single-symptom, PA endpoints in clinical trials assessing radiation skin toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Patterns of Practice in the Management of Radiation Therapy-induced Nausea and Vomiting

Purpose: To investigate international patterns of practice in the management of radiation therapy-induced nausea and vomiting (RINV). Methods and Materials: Oncologists prescribing radiation therapy in the United States, Canada, The Netherlands, Australia, New Zealand, Spain, Italy, France, Hong Kong, Singapore, Cyprus, and Israel completed a Web-based survey that was based on 6 radiation therapy-only clinical cases modeled after the minimal-, low-, moderate-, and high-emetic risk levels defined in the antiemetic guidelines of the American Society of Clinical Oncology and the Multinational Association of Supportive Care in Cancer. For each case, respondents estimated the risks of nausea and vomiting separately and committed to an initial management approach. Results: In total, 1022 responses were received. Risk estimates and management decisions for the minimal- and high-risk cases varied little and were in line with guideline standards, whereas those for the low- and moderate-risk cases varied greatly. The most common initial management strategies were as follows: rescue therapy for a minimal-risk case (63% of respondents), 2 low-risk cases (56% and 80%), and 1 moderate-risk case (66%); and prophylactic therapy for a second moderate-risk case (75%) and a high-risk case (95%). The serotonin (5-HT){sub 3} receptor antagonists were the most commonly recommended prophylactic agents. On multivariate analysis, factors predictive of a decision for prophylactic or rescue therapy were risk estimates of nausea and vomiting, awareness of the American Society of Clinical Oncology antiemetic guideline, and European Society for Therapeutic Radiology and Oncology membership. Conclusions: Risk estimates and management strategies for RINV varied, especially for low- and moderate-risk radiation therapy cases. Radiation therapy-induced nausea and vomiting are under-studied treatment sequelae. New observational and translational studies are needed to allow for individual patient risk assessment and to refine antiemetic guideline management recommendations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transforming Growth Factor β-1 (TGF-β1) Is a Serum Biomarker of Radiation Induced Fibrosis in Patients Treated With Intracavitary Accelerated Partial Breast Irradiation: Preliminary Results of a Prospective Study

Purpose: To examine a relationship between serum transforming growth factor β -1 (TGF-β1) values and radiation-induced fibrosis (RIF). Methods and Materials: We conducted a prospective analysis of the development of RIF in 39 women with American Joint Committee on Cancer stage 0-I breast cancer treated with lumpectomy and accelerated partial breast irradiation via intracavitary brachytherapy (IBAPBI). An enzyme-linked immunoassay (Quantikine, R and D, Minneapolis, MN) was used to measure serum TGF-β1 before surgery, before IBAPBI, and during IBAPBI. Blood samples for TGF-β1 were also collected from 15 healthy, nontreated women (controls). The previously validated tissue compliance meter (TCM) was used to objectively assess RIF. Results: The median time to follow-up for 39 patients was 44 months (range, 5-59 months). RIF was graded by the TCM scale as 0, 1, 2, and 3 in 5 of 20 patients (25%), 6 of 20 patients (30%), 5 of 20 patients (25%), and 4 of 20 patients (20%), respectively. The mean serum TGF-β1 values were significantly higher in patients before surgery than in disease-free controls, as follows: all cancer patients (30,201 ± 5889 pg/mL, P=.02); patients with any type of RIF (32,273 ± 5016 pg/mL, P<.0001); and women with moderate to severe RIF (34,462 ± 4713 pg/mL, P<0.0001). Patients with moderate to severe RIF had significantly elevated TGF-β1 levels when compared with those with none to mild RIF before surgery (P=.0014) during IBAPBI (P≤0001), and the elevation persisted at 6 months (P≤.001), 12 months (P≤.001), 18 months (P≤.001), and 24 months (P=.12). A receiver operating characteristic (ROC) curve of TGF-β1 values predicting moderate to severe RIF was generated with an area under the curve (AUC){sub ROC} of 0.867 (95% confidence interval 0.700-1.000). The TGF-β1 threshold cutoff was determined to be 31,000 pg/mL, with associated sensitivity and specificity of 77.8% and 90.0%, respectively. Conclusions: TGF-β1 levels correlate with the development of moderate to severe RIF. The pre-IBAPBI mean TGF-β1 levels can serve as an early biomarker for the development of moderate to severe RIF after IBAPBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implications for elastic energy storage in the Himalaya from the Gorkha 2015 earthquake and other incomplete ruptures of the Main Himalayan Thrust

Rupture in the 2015 M7.8 Gorkha earthquake nucleated at the downdip edge of the Main Himalayan Thrust (MHT) near the transition from interseismic locking to aseismic creep beneath the Tibetan plateau, and propagated incompletely towards the Main Frontal Thrusts (MFT). Despite the imposition of a substantial static strain in the mid-décollement, afterslip on the MHT within a year of the earthquake had decayed to negligible levels. Earthquakes that incompletely rupture the MHT (7 < Mw < 7.9) have been relatively common in the past two centuries, and as a consequence heterogeneous patches of stored elastic strain must exist throughout the Himalaya similar to that emplaced by the Gorkha earthquake. We show that these patches of stored strain are not dissipated by creep or by subsequent updip earthquakes, with the possible exceptions of a sequence of moderate earthquakes to the west of the great 1950 Assam earthquake, and to the east of the Kangra 1905 earthquake. It is thus considered likely that mid-décollement strain newly imposed by the Gorkha earthquake, and other recent incomplete ruptures will be incorporated in the rupture of a future much larger earthquake. Incomplete ruptures (i.e. those that nucleate downdip but fail to rupture the frontal thrusts) appear to occur preferentially in parts of the central Himalaya characterized by relatively narrow transition regions of interseismic decoupling (<30 km downdip). Assuming uniform strain at failure these narrow zones are unable to store large amounts of strain energy compared to wide zones of interseismic decoupling. Since the transition from fully locked to a fully creeping rheology depends partly on temperature, to first order the width of the interseismic decoupling transition zone depends on the local dip of the MHT. Where the decoupling zone is narrow (25 km) moderate earthquakes (6 < Mw < 7) are observed to occur at intervals of a few hundred years. Where the transition zone is wide (e.g. Kashmir and Assam, 150 km) great earthquakes nucleate at long time intervals (millennia). Because the cumulative moment release of moderate earthquakes in regions of narrow seismic decoupling is insufficient to keep up with plate convergence, we conclude that megaquakes that eventually sweep through these regions are augmented by the heterogenous fossil strain of former incomplete ruptures. Because great earthquakes in the central Himalaya are inferred to nucleate from moderate earthquakes near the base of the MHT, the preparation zones of these moderate earthquakes may provide opportunities for forecasting the approach of future great earthquakes.

58 GEOSCIENCES↗

Determination of energy correction coefficient for neutron albedo dosimeter. Three approaches

To accurately determine dose, albedo TLD dosimeters require application of a neutron energy correction factor (NECF). Here, in this paper, the results from three different methods were used to determine NECFs. In the first method, NECF values were calculated as a ratio of the known “conventional true” dose and the neutron dose reported by albedo dosimeter(s) irradiated on a phantom. The results from this direct method were utilized for verification of two other methods. The second method used a specially designed device called the Neutron Area Monitor (NAM) model 5. The third method of NECF determination was based on the response of a BF 3 tube under different levels of moderation. The results of this work showed that the Navy-developed Neutron Area Monitor (NAM) model 5 measures NECF values correctly when irradiated with 252 Cf (bare and D 2 O-moderated). This was an important result, because it validated the use of the NAM-5 in nuclear power and marine propulsion reactors, as their neutron energy spectrum is approximated by the field of a Cadmium-coated 30 cm diameter steel sphere of D 2 O moderated 252 Cf. In the case of a broad neutron energy spectrum the 6 Li response to the small amount of slow neutrons outweighs its response to the fast neutrons overwhelmingly responsible for the neutron dose rate. Based on the obtained results we can conclude that NAM-5 provides correct NECF determination if the fraction of slow neutrons in the neutron dose rate is more than 20%. A satisfactory correlation between the NECF determined by NAM-5 and the multi-moderated BF3 tube method was observed, but the multi-moderated BF 3 tube values were ~30% lower than those obtained by the NAM-5 at the same locations for broader neutron energy spectrum locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE COLOR DIFFERENCES OF KUIPER BELT OBJECTS IN RESONANCE WITH NEPTUNE

The optical colors of 58 objects in mean motion resonance with Neptune were obtained. The various Neptune resonant populations were found to have significantly different surface color distributions. The 5:3 and 7:4 resonances have semimajor axes near the middle of the main Kuiper Belt and both are dominated by ultra-red material (spectral gradient: S {approx}> 25). The 5:3 and 7:4 resonances have statistically the same color distribution as the low-inclination 'cold' classical belt. The inner 4:3 and distant 5:2 resonances have objects with mostly moderately red colors (S {approx} 15), similar to the scattered and detached disk populations. The 2:1 resonance, which is near the outer edge of the main Kuiper Belt, has a large range of colors with similar numbers of moderately red and ultra-red objects at all inclinations. The 2:1 resonance was also found to have a very rare neutral colored object showing that the 2:1 resonance is really a mix of all object types. The inner 3:2 resonance, like the outer 2:1, has a large range of objects from neutral to ultra-red. The Neptune Trojans (1:1 resonance) are only slightly red (S {approx} 9), similar to the Jupiter Trojans. The inner 5:4 resonance only has four objects with measured colors but shows equal numbers of ultra-red and moderately red objects. The 9:5, 12:5, 7:3, 3:1, and 11:3 resonances do not have reliable color distribution statistics since few objects have been observed in these resonances, though it appears noteworthy that all three of the measured 3:1 objects have only moderately red colors, similar to the 4:3 and 5:2 resonances. The different color distributions of objects in mean motion resonance with Neptune are likely a result from the disruption of the primordial Kuiper Belt from the scattering and migration of the giant planets. The few low-inclination objects known in the outer 2:1 and 5:2 resonances are mostly only moderately red. This suggests if the 2:1 and 5:2 have a cold low-inclination component, the objects likely had a significantly different origin than the ultra-red-dominated cold components of the cold classical belt and 5:3 and 7:4 resonances.