Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Testing of the Engineering Model Electrical Power Control Unit for the Fluids and Combustion Facility

The John H. Glenn Research Center at Lewis Field (GRC) in Cleveland, OH and the Sundstrand Corporation in Rockford, IL have designed and developed an Engineering Model (EM) Electrical Power Control Unit (EPCU) for the Fluids Combustion Facility, (FCF) experiments to be flown on the International Space Station (ISS). The EPCU will be used as the power interface to the ISS power distribution system for the FCF's space experiments'test and telemetry hardware. Furthermore. it is proposed to be the common power interface for all experiments. The EPCU is a three kilowatt 12OVdc-to-28Vdc converter utilizing three independent Power Converter Units (PCUs), each rated at 1kWe (36Adc @ 28Vdc) which are paralleled and synchronized. Each converter may be fed from one of two ISS power channels. The 28Vdc loads are connected to the EPCU output via 48 solid-state and current-limiting switches, rated at 4Adc each. These switches may be paralleled to supply any given load up to the 108Adc normal operational limit of the paralleled converters. The EPCU was designed in this manner to maximize allocated-power utilization. to shed loads autonomously, to provide fault tolerance. and to provide a flexible power converter and control module to meet various ISS load demands. Tests of the EPCU in the Power Systems Facility testbed at GRC reveal that the overall converted-power efficiency, is approximately 89% with a nominal-input voltage of 12OVdc and a total load in the range of 4O% to 110% rated 28Vdc load. (The PCUs alone have an efficiency of approximately 94.5%). Furthermore, the EM unit passed all flight-qualification level (and beyond) vibration tests, passed ISS EMI (conducted, radiated. and susceptibility) requirements. successfully operated for extended periods in a thermal/vacuum chamber, was integrated with a proto-flight experiment and passed all stability and functional requirements.

Kimnach, Greg L.↗

A Fast Load Control System Based on Mobile Distribution-Level Phasor Measurement Unit

The increase of renewable penetration in power grids calls for loads to participate in frequency regulation to avoid under-frequency load shedding after large resource contingencies. The motivation of our work is to fulfill a fast residential load control for frequency stability enhancement. For this purpose, a novel Mobile Distribution-level Phasor Measurement Unit (MDPMU) is developed for disturbance event detection, power mismatch estimation and fast load control. First, the systematic design of the MDPMU introduced. The proposed MDPMU has the major advantages of low cost and high frequency measurement accuracy. Second, the distribution-level measurement is utilized for the Rate Of Change Of Frequency (ROCOF) calculation. Upon detection of a power system frequency event, power mismatch is estimated at the early stage of the event. Details of a robust approach to calculate ROCOF and determine the event starting point are presented. Practical issues including the measurement reporting rate and estimation time are also examined. Finally, with the proposed control system, residential load responses can be controlled coordinately based on load availability and compensation prices offered by customers, providing adaptive frequency regulation service after large resource contingencies. The accuracy of frequency measurement and power mismatch estimation are evaluated via experimental analysis. The frequency stability improvement by load control is validated via PSS/E simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Desalination as Cooling for a Supercritical Carbon Dioxide Brayton Cycle

Multi-effect distillation (MED) is commonly used for seawater desalination. MED offers numerous advantages over other existing thermal desalination systems. MED systems are commonly integrated with a steam-Rankine power cycle, for simultaneous production of power and freshwater. Low-pressure steam is extracted from the power cycle to act as a heat source for the MED. The operating temperature of the low-pressure steam must be high enough to drive the MED system. This necessitates an increase in the operating pressure on the power-cycle condenser, resulting in a decrease in power production. Hence, integration of MED with the steam-Rankine cycle is a parasitic load for the power plant. The supercritical carbon dioxide (sCO2) Brayton cycle is being pursued as a new power cycle because of its potential for higher energy efficiency and compact turbomachinery. The sCO2 exiting the low-temperature recuperator is quite hot and is cooled as a sensible-heat fluid before flowing back to the compressor. This heat is sufficiently hot to drive an MED system, rather than being rejected to the environment. Such a thermal integration could lead to simultaneous production of power and potable water without affecting the sCO2 Brayton cycle efficiency. The objective of the present study is to maximize the distillate production from MED without acting as a parasitic load. Optimal feed configuration for the MED is identified for maximizing the distillate concentration. Techno-economic analysis showed the cost of distillate for MED is about 30% lower than distillate produced by reverse osmosis (RO).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilization of Additive Manufacturing for the Rapid Prototyping of C-Band Radiofrequency Loads

Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for developing an effective prototype load produced from 316L stainless steel on a direct metal laser sintering machine. The model was tested using simulation software to verify the validity of the design. The load structure was manufactured by an online digital manufacturing company, showing the viability of using easily accessible tools to manufacture RF structures. The produced load was able to produce an S11 value of −22.8 dB at a C-band frequency of 5.712 GHz while under a vacuum. In a high-power test, the load was able to terminate a peak power of 8.1 MW. The discussion includes future applications of the present method and how it will help to improve the implementation of future accelerator concepts.

36 MATERIALS SCIENCE↗

A Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System

This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.

Hu, Rongxing↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

Design of an Ultra-High Efficiency GaN High-Power Amplifier for SAR Remote Sensing

This work describes the development of a high-power amplifier for use with a remote sensing SAR system. The amplifier is intended to meet the requirements for the Sweep-SAR technique for use in the proposed DESDynI SAR instrument. In order to optimize the amplifier design, active load-pull technique is employed to provide harmonic tuning to provide efficiency improvements. In addition, some of the techniques to overcome the challenges of load-pulling high power devices are presented. The design amplifier was measured to have 49 dBm of output power with 75% PAE, which is suitable to meet the proposed system requirements.

active load-pull↗

Gas tube-switched flexible alternating current transmission system

A var compensator circuit is provided. The var compensator circuit includes a gas tube switch and a reactive impedance. The gas tube switch is configured to be coupled to a transmission line. The transmission line is configured to deliver real power and reactive power to a load at an alternating current (AC) line voltage. The reactive impedance is configured to be coupled to the transmission line at the AC line voltage through the gas tube switch. The reactive impedance is configured to modify the reactive power configured to be delivered to the load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multifidelity multiobjective optimization for wake-steering strategies

Abstract. Wake steering is an emerging wind power plant control strategy where upstream turbines are intentionally yawed out of perpendicular alignment with the incoming wind, thereby “steering” wakes away from downstream turbines. However, trade-offs between the gains in power production and fatigue loads induced by this control strategy are the subject of continuing investigation. In this study, we present a multifidelity multiobjective optimization approach for exploring the Pareto front of trade-offs between power and loading during wake steering. A large eddy simulation is used as the high-fidelity model, where an actuator line representation is used to model wind turbine blades and a rainflow-counting algorithm is used to compute damage equivalent loads. A coarser simulation with a simpler loads model is employed as a supplementary low-fidelity model. Multifidelity Bayesian optimization is performed to iteratively learn both a surrogate of the low-fidelity model and an additive discrepancy function, which maps the low-fidelity model to the high-fidelity model. Each optimization uses the expected hypervolume improvement acquisition function, weighted by the total cost of a proposed model evaluation in the multifidelity case. The multifidelity approach is able to capture the logit function shape of the Pareto frontier at a computational cost only 30 % that of the single-fidelity approach. Additionally, we provide physical insights into the vortical structures in the wake that contribute to the Pareto front shape.

17 WIND ENERGY↗

ICRF Antenna Characteristics and Comparison with 3-D Code Calculation in the LHD

The plasma coupling characteristics and local heat spots of an ion cyclotron range of frequencies (ICRF) antenna in the Large Helical Device (LHD) are compared with the results of 3-D computing simulator code calculation. We studied several dependences of antenna loading resistances with plasma experimentally and observed a clear relation between the maximum injection power and the loading resistance. Realistic three-dimensional configuration of the ICRF antenna was taken into account to simulate the coupling characteristics and the local heat absorption near the ICRF antenna, which has a helically twisted geometry in the LHD. The electromagnetic field distribution and the current distribution on the antenna strap were calculated. We compared the RF absorption distribution on the antenna structure with the temperature rise during steady state operation and found that the temperature rise was well explained by comparing with the model simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A revisit to self-excited push pull vacuum tube radio frequency oscillator for ion sources and power measurements

Self-excited push-pull vacuum tube oscillator is one of the most commonly used oscillators in radio frequency (RF)-ion plasma sources for generation of ions using radio frequency. However, in spite of its fundamental role in the process of plasma formation, the working and operational characteristics are the most frequently skip part in the descriptions of RF ion sources in literatures. A more detailed treatment is given in the present work on the RF oscillator alone using twin beam power tetrodes 829B and GI30. The circuit operates at 102 MHz, and the oscillation conditions, stability in frequency, and RF output power are studied and analyzed. A modified form of photometric method and RF peak voltage detection method are employed to study the variation of the oscillator output power with plate voltage. The power curves obtained from these measurements are quadratic in nature and increase with increase in plate voltage. However, the RF output power as measured by photometric methods is always less than the value calculated from peak voltage measurements. This difference is due to the fact that the filament coil of the ordinary light bulb used as load/detector in photometric method is not a perfect inductor. The effect of inductive reactance on power transfer to load was further investigated and a technique is developed to estimate the amount of power correction needed in the photometric measurement result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Market assessment of photovoltaic power systems for agricultural applications in Mexico

The first year of cost-competitiveness, the market potential, and the environment in which PV systems would be marketed and employed were examined. Market elements specific to Mexico addressed include: (1) useful applications and estimates of the potential market for PV systems; (2) power requirements and load profiles for applications compatible with PV usage; (3) operating and cost characteristics of power systems that compete against PV; (4) national development goals in rural electrification and rural services, technology programs and government policies that influence the demand for PV in Mexico; (5) financing mechanisms and capital available for PV acquisition; (6) channels for distribution, installation and maintenance of PV systems; and (7) appropriate methods for conducting business in Mexico.

Steigelmann, W.↗

Solving Unit Commitment Problems with Demand Responsive Loads: Preprint

This paper focuses on using variations of the Frank-Wolfe algorithm for solving unit commitment problems with high volumes of demand responsive loads on the power grid. We present a formulation of the unit commitment problem with demand responsive loads. We then show through reformulation and relaxations of the problem that variations of the Frank-Wolfe algorithm can be used to determine the time series decisions for the demand responsive loads. We show through computational experiments on the RTS-GMLC test system that the time series of demand responsive load decisions obtained through our approach are near optimal and provide details regarding how large scale parallel implementations of our approach can be highly computationally efficient.

demand response↗

Portable I/V-Curve Tester

Electronic load circuit for displaying current/voltage characteristic curves of power sources uses low-cost low-power CMOS operational amplifiers to control load current flowing through power MOSFET Q2 and main load transistor Q3. Thermal cutoff device turns off transistor Q3 in case of overload. To maximize battery life, battery is connected via "push-to-read" momentary-contact pushbutton switch.

Cole, S. W.↗

Study of Voltage-Dependent Harmonic Characteristics of Residential Appliances

This paper focuses on the electrical characteristics of residential and domestic appliances and their effects to the power grid. With the ever-changing load landscape and the introduction of power electronics-based equipment and energy-efficient loads, it is increasingly important to have a thorough knowledge of their power quality and harmonic characteristics in addition to conventional load models. This is critical to the accurate load representations, particularly for the complete bottom-up load models, in voltage stability assessment, determining possible interactions at harmonic frequencies, the effect of the system impedance, as well as possible voltage sag and swell and unbalance conditions. For this study, the household appliances are grouped into five categories: lighting, power electronics, resistive, motor, and aggregated loads. The effect of the voltage variation on the load current characteristics is also studied. The results from laboratory experiments involving most of the commonly used domestic appliances are analyzed within a range of +10%/-5% of the nominal supply voltage and within a range of +/-3 Hz of the nominal supply frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Communication Simulations for Power System Applications

New smart grid technologies and concepts, such as dynamic pricing, demand response, dynamic state estimation, and wide area monitoring, protection, and control, are expected to require considerable communication resources. As the cost of retrofit can be high, future power grids will require the integration of high-speed, secure connections with legacy communication systems, while still providing adequate system control and security. While considerable work has been performed to create co-simulators for the power domain with load models and market operations, limited work has been performed in integrating communications directly into a power domain solver. The simulation of communication and power systems will become more important as the two systems become more inter-related. This paper will discuss ongoing work at Pacific Northwest National Laboratory to create a flexible, high-speed power and communication system co-simulator for smart grid applications. The framework for the software will be described, including architecture considerations for modular, high performance computing and large-scale scalability (serialization, load balancing, partitioning, cross-platform support, etc.). The current simulator supports the ns-3 (telecommunications) and GridLAB-D (distribution systems) simulators. Ongoing and future work will be described, including planned future expansions for a traditional transmission solver. A test case using the co-simulator, utilizing a transactive demand response system created for the Olympic Peninsula and AEP gridSMART demonstrations, requiring two-way communication between distributed and centralized market devices, will be used to demonstrate the value and intended purpose of the co-simulation environment.

co-simulation↗