At least 991 records · Page 55

Advancements in Force and Angle Measurement by the NFMTC

The National Force Measurement Technology Capability (NFMTC) is a nationwide partnership established in 2008 and sponsored by NASA’s Aeronautics Evaluation and Test Capabilities (AETC) project to maintain and further develop force and angle measurement capabilities primarily for NASA’s ground test facilities. One of the NFMTC’s primary objectives is to develop new force and angle measurement capabilities to meet the needs of researchers testing in NASA’s ground test facilities. This work will highlight several new capabilities that are either at or near operational readiness. A new six-component flow-through balance was designed and fabricated to support an upcoming retropropulsion test campaign at the NASA Langley Unitary Plan Wind Tunnel. The balance employs membranes in place of bellows, which have historically been used, and passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure retropropulsion performance of powered descent vehicles. Balances used in NASA’s ground test facilities are typically either single-piece balances or floating-frame balances. Historically, these two types of balances have generally used different front-end (model) attachments. Single-piece balances generally have a cylindrical front end that is forward of any measuring sections and at a reduced diameter relative to the balance outer diameter. Floating-frame balances generally have front end fits that extend over one or more measuring sections and that engage at the balance outer diameter. Recently, the NFMTC fabricated a single-piece balance with a front end fit that is compatible with the hardware used to calibrate floating-frame balances. Calibration results evaluating this front end fit will be presented. From a recent survey of angle measurement needs, the development of smaller angle measurement packages was identified as one area of improvement. Micro-electromechanical systems (MEMS) are continually being refined to provide high performance accelerometers that are a fraction of the volume of the quartz flexure based accelerometers that are standard in wind tunnels. A survey of commercial off-the-shelf MEMS accelerometers was conducted, and it identified the Safran Colibrys MS lines to be of adequate performance. Single-axis test boards and tri-axis rigid-flex production boards were designed and fabricated with a volume of approximately .18 cubic inches. The boards were designed to provide all the necessary conditioning for the MEMS accelerometers at levels to meet or exceed all requirements for the MS line sensors. Preliminary testing of these assembled sensor packages has demonstrated acceptable performance for wind-tunnel angle measurement. Several new rotating balances are at various stages of completion for NASA Glenn Research Center’s fan drive rigs. These balances provide direct measurement of thrust and torque of a driven fan or fan section to provide an estimate of fan efficiency and net thrust. Three two-component balances have been recently completed, and one six-component balance is in active development. A custom rotating telemetry system has been developed to support testing with these balances, and the telemetry system is integrated into the forward end of each one. The telemetry system is designed to remove mechanical sliprings by using an optical ethernet-based slipring for data transmission.

Force measurement↗

Comparisons of Artemis I and Wind Tunnel Buffet Environments and Induced Structural Responses

This paper presents comparisons of buffet forcing functions (BFFs) and associated structural responses for the Space Launch System from two data sources: 1) Artemis I (AR01) Developmental Flight Instrumentation (DFI) and 2) transonic wind-tunnel (WT) tests. Failures of DFI sensors prevented the development of a complete set of flight-based BFFs, where each BFF is based on azimuthal integration over 360-degrees of unsteady pressures acquired by sensor rings placed at many longitudinal stations along the vehicle. Instead, a set of equivalent flight- and WT-based BFFs was developed based on functional DFI and WT sensors that share the same locations. Root-mean-square (rms) levels of equivalent BFFs from flight and WT data are in-family for most of the cardinal Mach numbers. However, at stations downstream of the booster forward attachment (FA) protuberance, the rms of flight-based BFFs exceed their WT counterparts. Strikingly, vortex-shedding off the FA protuberance occurs at lower frequencies during flight than in WT experiments. This frequency shift propagates onto the spectrum of flight-measured vs. WT-based structural responses. Aside from vortex-shedding frequency mismatch, a generally good agreement between AR01 and WT-based responses is an indirect indication that WT buffet environments are fairly well representative of their AR01 counterpart.

transonic buffet↗

Comparisons of Artemis I and Wind Tunnel Buffet Environments and Induced Structural Responses

This paper presents comparisons of buffet forcing functions (BFFs) and associated structural responses for the Space Launch System from two data sources: 1) Artemis I (AR01) Developmental Flight Instrumentation (DFI) and 2) transonic wind-tunnel (WT) tests. Failures of DFI sensors prevented the development of a complete set of flight-based BFFs, where each BFF is based on azimuthal integration over 360-degrees of unsteady pressures acquired by sensor rings placed at many longitudinal stations along the vehicle. Instead, a set of equivalent flight- and WT-based BFFs was developed based on functional DFI and WT sensors that share the same locations. Root-mean-square (rms) levels of equivalent BFFs from flight and WT data are in-family for most of the cardinal Mach numbers. However, at stations downstream of the booster forward attachment (FA) protuberance, the rms of flight-based BFFs exceed their WT counterparts. Strikingly, vortex-shedding off the FA protuberance occurs at lower frequencies during flight than in WT experiments. This frequency shift propagates onto the spectrum of flight-measured vs. WT-based structural responses. Aside from vortex-shedding frequency mismatch, a generally good agreement between AR01 and WT-based responses is an indirect indication that WT buffet environments are fairly well representative of their AR01 counterpart.

transonic buffet↗

Catalyst Ammonia Storage Measurements Using Radio Frequency Sensing1

Motivated by increasingly strict nitrogen oxides (NOx) limits, engine manufacturers have adopted selective catalytic reduction (SCR) technology to reduce engine-out NOx. In the SCR process, NOx react with ammonia (NH3) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NOx and/or NH3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF)-based method to directly monitor the ammonia storage state of the SCR. This approach utilizes the catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH3) were evaluated over a wide range of frequencies, temperatures, and exhaust conditions. The RF response to NH3 storage, desorption, and oxidation on the SCR was well correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10% of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NOx conversion and decrease urea consumption.

Engineering↗

Explosion-Generated Infrasound Recorded on Ground and Airborne Microbarometers at Regional Distances

Recent work in deploying infrasound (low–frequency sound) sensors on aerostats and free–flying balloons has shown them to be viable alternatives to ground stations. However, no study to date has compared the performance of surface and free–floating infrasound microbarometers with respect to acoustic events at regional (100s of kilometers) range. The prospect of enhanced detection of aerial explosions at similar ranges, such as those from bolides, has not been investigated either. We examined infrasound signals from three 1–ton trinitrotoluene (TNT) equivalent chemical explosions using microbarometers on two separate balloons at 280– to 400–km ranges and ground stations at 6.3– to 350–km ranges. Signal celerities were consistent with acoustic waves traveling in the stratospheric duct. However, significant differences were noted between the observed arrival patterns and those predicted by an acoustic propagation model. Very low–background noise levels on the balloons were consistent with previous studies that suggest wind interference is minimal on freely drifting sensors. In conclusion, simulated propagation patterns and observed noise levels also confirm that balloon–borne microbarometers should be very effective at detecting explosions in the middle and upper atmosphere as well as those on the surface.

58 GEOSCIENCES↗

Advanced Control Architecture and Sensor Information Development for Process Automation, Optimization, and Imaging of Chemical Looping Systems

The Syngas Chemical Looping (SCL) process developed at The Ohio State University (OSU) uses an iron-based oxygen carrier to convert syngas into high-purity hydrogen while simultaneously capturing carbon dioxide that is readily sequestrable. A 25 kWth sub-pilot unit was successfully demonstrated multiple times on the OSU Clean Coal Research Facility, and a 250 kWth – 3 MWth pilot demonstration unit has been designed and constructed at the National Carbon Capture Center (NCCC) in Wilsonville, Alabama. The focus of this project is to develop multiple technologies to automate the startup and shutdown of chemical looping system. Success of this project will propel the advanced carbon capture method toward commercialization, hence be disruptive to the fossil fuel and power industries. Advanced process automation control architecture and imaging and optimization sensor software were developed for OSU chemical looping process. A high-level controller (HLC) consisting of decision-making and controller-selection logic integrated with sliding mode controllers (SMCs) were developed to perform chemical looping process startup and shutdown. Babcock & Wilcox Power Generation Group’s FocalPoint Optimization System was implemented to optimize the process operating conditions. The process automation controller and optimization information were realized and tested on OSU’s existing sub-pilot chemical looping test unit under atmospheric condition. The implemented control architecture was able to perform the complete process procedure from startup, steady-state reaction operation to shutdown with minimal operator intervention. The controller was also implemented on the pressurized syngas chemical looping (SCL) pilot test unit constructed at the National Carbon Capture Center (NCCC), demonstrating its pressure control capability with a designed transient state trajectory. An electrical capacitance volume tomography (ECVT) sensor device and its software were developed to image the packed moving bed and slugging fluidized bed of oxygen carriers in chemical looping systems at elevated temperatures. The ECVT device constructed was capable of tracking the subtle voidage variance along the moving bed axis as a feature for directly measuring the oxygen carrier particles’ linear velocity. Also, the high temperature ECVT device was used to study the fluidization characteristics of Geldart Group D particles.

08 HYDROGEN↗

Integrated Refrigeration and Storage of LNG for Compositional Stability

Growing interest in liquefied natural gas (LNG) as a rocket fuel necessitates a greater technical understanding of the compositional changes due to preferential boil-off (or weathering) that occurs during long duration storage. The purity of methane in LNG can range from 90 to 98%, and is subject to preferential boil-off due to its low boiling point compared to other constituents despite the use of high-performance thermal insulation systems. Active heat extraction (i.e. refrigeration) is required to completely eliminate weathering. For future operational safety and reliability, and to better understand the quality and efficiency of the LNG as a cryofuel, a 400-liter Cryostat vessel was designed and constructed to measure the composition and temperatures of the LNG at a number of different liquid levels over long durations. The vessel is the centerpiece of a custom-designed lab-scale integrated refrigeration and storage (IRaS) system employing a pulse tube cryocooler capable of roughly 50 W of lift at 100 K. Instrumentation includes ten temperature sensors mounted on a vertical rake and five liquid sample tubes corresponding to five liquid levels. Two modes of operation are studied. The first is without refrigeration in order to determine a baseline in the change in composition, and to study stratification of the LNG. The second is performed with the cryocooler active to determine the operational parameters of the IRaS system for eliminating the weathering as well as stratification effects in the bulk liquid. The apparatus design and test method, as well as preliminary test results are presented in this paper. As a bonus in cost-saving and operational efficiency, the capability of the IRaS system to provide zero-loss capabilities such as zero boil-off (ZBO) keeping of the LNG and zero-loss filling/transfer operations are also discussed.

Rose, Laura P.↗

Integrated Refrigeration and Storage of LNG for Compositional Stability

Growing interest in liquefied natural gas (LNG) as a rocket fuel necessitates a greater technical understanding of the compositional changes due to preferential boil-off (or weathering) that occurs during long duration storage. The purity of methane in LNG can range from 90 to 98%, and is subject to preferential boil-off due to its low boiling point compared to other constituents despite the use of high-performance thermal insulation systems. Active heat extraction (i.e. refrigeration) is required to completely eliminate weathering. For future operational safety and reliability, and to better understand the quality and efficiency of the LNG as a cryofuel, a 400-liter Cryostat vessel was designed and constructed to measure the composition and temperatures of the LNG at a number of different liquid levels over long durations. The vessel is the centerpiece of a custom-designed lab-scale integrated refrigeration and storage (IRaS) system employing a pulse tube cryocooler capable of roughly 50 W of lift at 100 K. Instrumentation includes ten temperature sensors mounted on a vertical rake and five liquid sample tubes corresponding to five liquid levels. Two modes of operation are studied. The first is without refrigeration in order to determine a baseline in the change in composition, and to study stratification of the LNG. The second is performed with the cryocooler active to determine the operational parameters of the IRaS system for eliminating the weathering as well as stratification effects in the bulk liquid. The apparatus design and test method, as well as preliminary test results are presented in this paper. As a bonus in cost-saving and operational efficiency, the capability of the IRaS system to provide zero-loss capabilities such as zero boil-off (ZBO) keeping of the LNG and zero-loss filling/transfer operations are also discussed.

Rose, L.↗

One-Step Ahead Prediction of Thermal Mixing Tee Sensors with Long Short Term Memory (LSTM) Neural Networks

High-temperature advanced reactors under development, such as sodium fast reactors (SFR) and molten salt cooled reactors (MSCR), are expected to offer lower levelized cost of energy (LCOE) compared to existing light water reactor (LWR’s). In the existing light water reactors (LWR’s), operation and maintenance (O&M) expenses constitute the largest fraction of the total operating cost. Some of the O&M costs are related maintenance of sensors which can fail due to exposure to harsh environment in a reactor. The O&M costs of Advanced Reactor (AR)’s are expected to constitute a significant fraction of the total cost as well, because of high temperature and radiation level in AR are likely to cause material fatigue and premature failure of sensors and components. The O&M costs in AR’s could be reduced through integration of advanced informatics of performance-related sensors into a digital twin designed for reactor monitoring. For example, machine learning (ML) could be employed for real-time validation and correction of performance-related sensors, and reducing the number of performance-related physical sensor units through virtual sensing. As part of the effort, we investigate real-time validation of thermal hydraulic sensors through one-step ahead forecasting of sensor values using long short-term memory (LSTM) recurrent neural networks (RNN). The sensors are installed in a flow loop containing a thermal mixing tee, which is a common experimental model to study thermal fatigue in a thermal hydraulic loop. In addition, nonlinear transients generated in a thermal mixing tee constitute a good challenge data set for training and validation of ML algorithms. Sensors in this study include thermocouples, flow meters, and optical fibers for distributed temperature sensing. In one experiment, measurement data sets were obtained for a loop was filled with water, and in another experiment, measurements were performed on a loop filled with liquid metal Galinstan. We have also conducted preliminary investigation of one-step ahead prediction of fiber optics-based distributed temperature sensing with LSTM networks. In predicting fiber-based temperature measurements, we treated each gauge pitch of the fiber as an independent sensor. Accuracy of one-step ahead forecasting was estimated by calculating root mean square error (RMSE) for the test segment of time series of each sensor. RMSE’s for temperature sensors in water loop were, for the most part, lower than for the same sensors in Galinstan loop. The RMSE’s for flow meters were similar for both loops. The RMSE’s for distributed temperature measured with the fiber optic sensor were similar to those of the point sensors. Results of this study demonstrated the capability of LSTM one-step ahead forecasting with RMSE comparable to uncertainty in sensor measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Doped Lanthanum Chromite-refractory Based Composites Sensors for High Temperature Monitoring in Harsh Environments Systems

In order to test and monitor the operational stability and conditions of various energy, and manufacturing systems and their components, development of accurate sensors capable of operating at temperatures in excess of 1000 °C in various environments for long durations is required. In addition, many of these harsh-environment systems do not permit sensors to be directly inserted, so these sensors need to be embedded into thermal protective materials. In this work were developed high-temperature embedded thermocouples composed of various doped lanthanum chromites-refractory based composites synthesized by a mixed-oxide route and directly embedded into a Al2O3 based refractory. The electrical properties were specifically manipulated by altering the level of percolation of the conductive phase within the refractory constituent. Chemical stability of sensors was determined by phase development analysis by X-ray diffraction and X-ray photoelectron spectroscopy; Seebeck coefficients were determined by thermoelectric voltages measurements at temperature up to 1400 oC.

Perovskite LaCrO3, High-temperature conductivity, ↗

Remote Sensing Measurements of Vertical and Horizontal Moisture Variations from Aircraft Instruments

The research in this paper focuses on describing vertical and horizontal of water vapor variability using two remote sensing aircraft instruments. To achieve this goal we will compare precipitable water and upper level humidity estimates derived from the each of the instruments. The Multispectral Atmospheric Mapping Sensor (MAMS) is a visible and infrared radiometer with similar channels to that of the GOES imager. MAMS has flown aboard the NASA ER-2 numerous times. It has been used to validate features observed with the previous series of GOES satellites. MAMS data has been used to study precipitable water and upper level water vapor as well as other geophysical parameters. MAMS provides the opportunity to obtain water vapor Imagery at 6.7 mm. Upper tropospheric humidity can be computed using this channel in a similar fashion to that of Soden and Bretherton. In addition to the water vapor channel, MAMS records data In 3 other Infrared channels and 8 visible and near Infrared bands at high spatial resolution (I 00 Abstract: m). The 1 1 and 12 mm infrared channels allow for the application of a split technique to derive total precipitable water. The Udar Atmospheric Sensing Experiment (LASE) which uses the Differential Absorption Udar (DIAL) technique for obtaining simultaneous water vapor and aerosol profiles through the entire troposphere. LASE operates In the 81 5 nm wavelength region and uses a double pulsed Ti:sapphire laser that is locked onto a water vapor line. LASE has good horizontal (IO km) and excellent vertical (300 m) resolution. MAMS and LASE collected data simultaneously on several ER-2 flights in September 1995. LASE mixing ratio profiles will be Integrated for comparison with MAMS precipitable water estimates and the upper tropospheric humidity will be computed for the layer observed by the MAMS 6.7 mm channel for comparison for this time period. Results show a significant correlation between the measurements of the two Instruments. Regions of high/low upper tropospheric humidity are apparent In measurements from both instruments. Also changes in boundary layer moisture depicted by LASE are reflected in the total precipitable water measured by MAMS.

Atkinson, R. J.↗

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob↗

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]↗

Enhanced ZIF-8-enabled colorimetric CO 2 sensing through dye-precursor synthesis

The accumulation of carbon dioxide (CO 2 ) within enclosed spaces, along with volatile organic compounds, under certain humidity, temperature, and ventilation conditions is associated with detrimental human health symptoms such as fatigue. Color-based chemical sensing is a promising approach to detect CO 2 levels relevant to indoor air quality through producing fast, quantifiable output visible to the naked eye. In a prior work, a colorimetric gas sensor was fabricated through synthesizing the metal-organic framework, ZIF-8, as the adsorbent, followed by post-synthetic mixing with a dye, phenol red (PSP), and primary amine, ethylenediamine (ED). While this sensor (termed PSP-ED/ZIF-8) maintained its structural integrity in atmospheric conditions and exhibited an increasing fuchsia-to-yellow color change with increasing CO 2 levels in dry environment, the colorimetric response greatly suffered in the presence of humid CO 2 . Here in this work, a significantly improved colorimetric CO 2 sensor (referred to as ED/PSP:ZIF-8) is accomplished through directly incorporating phenol red in the ZIF-8 metal and linker precursor solutions and then blending with ethylenediamine. MATLAB-generated color distributions and in-situ ultraviolet-visible (UV-Vis) spectroscopic studies quantitatively demonstrate an enhanced colorimetric gas response of ED/PSP:ZIF-8 compared to that of PSP-ED/ZIF-8 across an important range of CO 2 for indoor air quality monitoring (500 – 3500 ppm) and across a range of humidity. The new sensor also exhibits high selectivity to CO 2 compared to select volatile organic compounds, such as acetone and ethanol, which contribute to human health symptoms experienced indoors. The enhanced performance is attributed to the proposed incorporation of phenol red within ZIF-8, while maintaining the chemical stability of the MOF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A two-stage optical fusion framework for wildfire severity mapping across the conterminous United States

Accurate wildfire severity mapping (WSM) is essential for post-fire recovery planning, erosion risk assessment, ecosystem monitoring, and disaster risk reduction. Although Landsat and Sentinel optical imagery have been widely used for burn severity assessment, the added value of fusing multiple optical sensors has not been sufficiently quantified across diverse fire events, particularly since the launch of Landsat-9. This study evaluates whether multisensor optical fusion improves wildfire severity mapping relative to single-sensor baselines using Sentinel-2, Landsat-8, and Landsat-9 imagery across 40 wildfire events in the conterminous United States. We tested a two-stage fusion framework that combines feature-level fusion with pixel-level dimensionality reduction. First, feature-level fused datasets were created through early fusion by combining standardized post-fire bands from each sensor into a single predictor stack. Both raw reflectance bands and pairwise spectral transforms were retained to capture within- and cross-sensor spectral interactions. Second, Linear Discriminant Analysis was applied to both single-sensor and fused datasets to produce comparable low-dimensional feature spaces. Six machine-learning classifiers were then used to benchmark model performance with repeated spatially buffered train–test splits. Results show that Landsat-9 was the strongest single-sensor baseline. Among the fusion strategies, Sentinel-2 + Landsat-9 produced the most consistent improvement and reduced performance variability. Landscape-condition analysis further showed that this fusion was most beneficial in shrubland-dominated and high-terrain fires, where it achieved the highest overall mean accuracy and the fewest failures. In contrast, its benefits were less reliable in evergreen forests, mixed vegetation, and low- to moderate-elevation terrain. In operational settings, the Sentinel-2 + Landsat-9 configuration offers a practical solution for post-fire recovery planning, erosion-risk assessment, watershed management, and ecological monitoring when field observations are available and timely satellite-based information is needed.

Landsat↗

The Influence of Sensor and Flight Parameters on Texture in Radar Images

Texture is known to be important in the analysis of radar images for geologic applications. It was previously shown that texture features derived from the grey-level co-occurrence matrix (GLCM) can be used to separate large scale texture in radar images. The influence of sensor parameters, specifically the spatial and radiometric resolution and flight parameters, i.e., the orientation of the surface structure relative to the sensor, on the ability to classify texture based on the GLCM features is investigated. It was found that changing these sensor and flight parameters greatly affects the usefulness of the GLCM for classifying texture on radar images.

Frost, V. S.↗

Telemetric Sensors for the Space Life Sciences

Telemetric sensors for monitoring physiological changes in animal models in space are being developed by NASA's Sensors 2000! program. The sensors measure a variety of physiological measurands, including temperature, biopotentials, pressure, flow, acceleration, and chemical levels, and transmit these signals from the animals to a remote receiver via a wireless link. Thus physiologic information can be obtained continuously and automatically without animal handling, tethers, or percutaneous leads. We report here on NASA's development and testing of advanced wireless sensor systems for space life sciences research.

Hines, John W.↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.