Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Actuation of Deformable Mirrors Using Laser Controlled Pistons

Current deformable mirrors used for adaptive optics employ many actuators to adjust the mirror in order to compensate for optical irregularities. These mechanical actuators, which can number in the hundreds for a given mirror, require a significant amount of electrical wires in order to be controlled. The objective of this research is to implement a different type of actuator that can be controlled without the use of wires. The actuator developed employs a laser to quickly heat and expand the air in a closed 'cell'. When the air expands, it pushes a membrane that causes the mirror to move. Creating an array of these cells, and scanning them with a laser can control a deformable mirror. Testing showed that a single cell with a 5 mm diameter and 10 mm in length can deflect a membrane of aluminized Mylar in excess of our minimum requirement of 20 microns. These cells can now be assembled in a 5 x 5 matrix and attached to many small mirrors. An electro-mechanical scanning assembly can be used to aim the laser directly onto individual cells causing the mirror at that location to move.

deformable mirrors↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

Surface Modification of High-Carbon Steel Using Fiber Laser and Its Thermal, Microstructural and Tribological Analysis

In this study, surface modification of high-carbon steel was carried out using 2 kW fiber laser and thermal, microstructural and tribological characterizations were performed. The process parameters selected for laser surface treatment were laser power (600-1500 W) and scan speed (3000-4500 mm/min). Infrared pyrometer was used to record the surface temperature during the process. The metallographic analysis was carried out using an optical microscope to find the depth and width of the laser-treated zone. Scanning electron microscopy and energy-dispersive spectroscopy were performed to reveal the microstructure and compositional changes taking place in the laser-treated zone. It was observed that the dendritic growth took place from the top surface toward the center of the laser-treated zone. The amount of dendritic growth can be related to the maximum surface temperature generated during the process. XRD analysis indicated the formation of some intermetallic compounds and phase shifts taking place in the laser-treated zone. Residual stress analysis was performed to analyze the amount of stress accumulation in the laser-treated zone. When the temperature cycle was analyzed, it was found that the melting of the steel resulted in the formation of a surface under compressive stress while the non-melt hardened zone developed a surface under tensile stress. The maximum Vickers microhardness value achieved was about 958.8 HV{sub 0.5} for 1500 W power and 3000 mm/min scan speed. Scratch test was performed on the laser-treated track, and it was found that the hardened zone showed better tribological properties with respect to the parent material. Finally, it was observed that the surface roughness value increased with higher heat input probably due to high rate of oxide formation as well as due to the presence of martensite in the laser-treated zone.

36 MATERIALS SCIENCE↗

Laser-Driven Megavolt X-Ray and Neutron Source Optimization

This 4-month feasibility study assessed the options, trade-offs and major issues in using National Ignition Facility (NIF) and Advanced Radiographic Capability (ARC)-class laser beams for multipulse MeV x-ray and neutron radiography of high explosives (HE) driven experiments. It was performed in close collaboration with a second FS evaluating future HE radiography requirements and expected laser-based source data quality with respect to existing and alternate radiography sources. The study first reviewed the existing published data on MeV x-ray and neutron sources compared to requirements on yield (10 14 /sr for X-rays, > 10 13 /sr for neutrons), spot size (< 1 mm) and duration (< 20 ns). For MeV neutron sources, the preferred options are DTfilled exploding pusher targets or stagnating DT plasmas, each source requiring 50 kJ level. few ns beam irradiation at 0.5 or 0.35 micron wavelength. The preferred X-ray MeV source option to be fully assessed by a follow-up SI is an angularly and temporally-multiplexed multi-burst version of a Bremsstrahlung source (Courtois et al. 2011) irradiated by up to 7 10 ps, kJ-class 1 micron wavelength lasers beams. This multi-burst laser mode, submitted as an ROI and patent, should increase final laser optics damage energy thresholds based on 2 pulse tests and hence allow near full extraction of the 15 kJ of 1 micron laser energy available on a NIF beamline. Hydrodynamic simulations were used to evaluate the effects of preceding pulse irradiation on target integrity, and show that this can be mitigated by using 3D structured targets.

47 OTHER INSTRUMENTATION↗

Early Air Force Flight Test Center (AFFTC) experience with Peripheral Vision Horizon Displays (PVHD)

Three separate Air Force Flight Test Center (AFFTC) tests were conducted in 1980 and 1981 on two models of the peripheral vision horizon displays (PVHD) (Malcolm Horizon). A fixed base simulator test was conducted with twenty test pilot subjects using the Flight Simulator Demonstration Model which incorporated a Helium Neon laser as the light bar medium. Two separate flight tests were conducted by the Test Pilot School classes 80A and 80B in a Twin Otter commuter aircraft using the Stage A Model PVHD. The Xenon lighted A Model was tested in its original configuration by class 80A. Class 80B used a modified configuration which incorporated an AFFTC designed and manufactured hood. With the hood, the PVHD projected a thinner, distinct light bar. Only a few general remarks concerning the tests and unrestricted, overall conclusions reached by the author are presented. The conclusions of all three AFFTC evaluations of the PVHD concept were that it has not yet been adequately evaluated. There seems to be a significant learning curve associated with the PVHD and the project pilots for Test Pilot School Class 80B only got a good start on the learning curve. A lengthy learning curve for the PVHD should be anticipated in view of the training period required for the attitude display indicator (ADI). This does seem to point out that the PVHD, in its present form, is simply not as compelling as the natural horizon. It can also be concluded that any attempt at a valid evaluation of the PVHD concept can be done only under instrument meteorological conditions (IMC) or validly simulated IMC conditions. The knee in the learning curve, however, may be reached without full IMC, although it may take much longer to reach.

Schofield, B. L.↗

Load-cell based characterization system for a “Violin-Mode” shadow-sensor in advanced LIGO suspensions

The background to this work was a prototype shadow sensor, which was designed for retro-fitting to an advanced LIGO (Laser Interferometer Gravitational wave Observatory) test-mass/mirror suspension, in which 40 kg test-mass/mirrors are each suspended by four approximately 600 mm long by 0.4 mm diameter fused-silica suspension fibres. The shadow sensor comprised a LED source of Near InfraRed (NIR) radiation and a rectangular silicon photodiode detector, which, together, were to bracket the fibre under test. The aim was to detect transverse Violin-Mode resonances in the suspension fibres. Part of the testing procedure involved tensioning a silica fibre sample and translating it transversely through the illuminating NIR beam, so as to measure the DC responsivity of the detection system to fibre displacement. However, an equally important part of the procedure, reported here, was to keep the fibre under test stationary within the beam, whilst trying to detect low-level AC Violin-Mode resonances excited on the fibre, in order to confirm the primary function of the sensor. Therefore, a tensioning system, incorporating a load-cell readout, was built into the test fibre’s holder. The fibre then was excited by a signal generator, audio power amplifier, and distant loudspeaker, and clear resonances were detected. A theory for the expected fundamental resonant frequency as a function of fibre tension was developed and is reported here, and this theory was found to match closely with the detected resonant frequencies as they varied with tension. Consequently, the resonances seen were identified as being proper Violin-Mode fundamental resonances of the fibre, and the operation of the Violin-Mode detection system was validated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress and Plans for a US Laser System for the LISA Mission

NASA Goddard Space Flight Center is developing a master oscillator power amplifier (MOPA) laser transmitter for the ESA-led Laser Interferometer Space Antenna (LISA) mission. Taking advantage of our space laser experience and the emerging telecom laser technology, we are developing a full laser system for the LISA mission. Our research effort has included both master oscillator (MO) and power amplifier (PA) developments, and their environmental testing and reliability for space flight. Our current baseline for the MO is a low-mass, compact micro NPRO (m-NPRO) laser. The amplifier uses a robust mechanical design based on fiber components. We have performed laser system noise tests by amplitude- and frequency-stabilizing the PA output. We will describe our progress and plans to demonstrate a TRL 6 laser system, which is an essential step toward qualifying lasers for space applications, by 2021.

lasers↗

Compact, Passively Q-Switched Nd:YAG Laser for the MESSENGER Mission to the Planet Mercury

A compact, passively Q-switched Nd:YAG laser has been developed for the Mercury Laser Altimeter (MLA) instrument which is an instrument on the MESSENGER mission to the planet Mercury. The laser achieves 5.4 percent efficiency with a near diffraction limited beam. It has passed all space flight environmental tests at system, instrument, and satellite integration. The laser design draws on a heritage of previous laser altimetry missions, specifically ISESAT and Mars Global Surveyor; but incorporates thermal management features unique to the requirements of an orbit of the planet Mercury.

Krebs, Danny J.↗

Containment Chamber Systems Engineering Project

Lawrence Livermore National Laboratory (LLNL) is a leading research laboratory in material properties. The most notable facility at LLNL capable of determining equation of state data for hazardous materials is the National Ignition Facility (NIF). NIF is the most energetic laser in the world and is a very versatile system that allows for a variety of laser configurations and diagnostics. The flexibility that NIF offers makes it an attractive tool for high budget programs researching specific areas of interest. Some programs require many tests to be performed, and although NIF could be an option for performing these tests, the cost and time to perform the tests would not be feasible. Also, many of these tests would underutilize the full capacity of NIF’s lasers, and NIF does not have a dedicated light source suitable for the diagnostic requirement. The needs of these tests do not align with NIF’s capabilities. The physicists are the main stakeholders for the tests, and they require a third-generation light source to meet the desired diagnostic performance. The Dynamic Compression Sector (DCS) within the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is the facility that will meet necessary laser performance and the X-ray diagnostic performance in order to obtain the desired data. DCS does not have the capability to test hazardous material, and therefore DCS requires a method and hardware for ensuring that no hazardous material is exposed before, during, or after the test. After taking a system engineering evaluation of the need for a solution to perform laser shock experiments on hazardous materials with certain laser and X-ray characteristics, a solution is proposed that meets the requirements of each involved stakeholder. The proposed solution is to contain the targets within sealed vacuum chamber that will meet the protection requirements of each facility. The chamber would be assembled and pumped down at LLNL in facilities that can handle hazardous material. Then, the chamber would be shipped under vacuum to DCS, where the chamber will be inserted into the beam paths. DCS’s laser will enter the sealed chamber and impart a shock into the target of hazardous material while the X-ray will simultaneously image the material. Once each target has been fired, the chamber will be removed from the beam path and shipped to the proper disposal facility.

42 ENGINEERING↗

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy↗

Tetrafluoroethylene as a fuel component for an atomic fluorine generator of a supersonic continuous-wave chemical HF laser

A cheap and widely accessible combination (one of non-saturated perfluorocarbons), i.e. C{sub 2}F{sub 4} tetrafluoroethylene, is proposed as an alternative fuel component for an atomic fluorine generator of a supersonic cw chemical HF laser of self-contained type. Combustion products of the hypergolic F{sub 2} – C{sub 2}F{sub 4} – He mixture do not contain active relaxants of vibrationally excited HF(v) molecules. According to estimates, the atomic fluorine yield under comparable conditions is about 70 % in relation to that of the atomic fluorine generator operating on the F{sub 2} – D{sub 2} – He mixture which is the ‘basic’ one for a HF laser. The specific power is reduced by 23 % with an improvement in a set of the fuel performance and a significant reduction in the cost of triggering the laser in the course of its bench tests. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bubble Mass Transport Measurement in the Large-Scale Test Loops at Oak Ridge National Laboratory

Molten salts are complex fluids that incorporate multi-phase behavior depending on the chemistry and the physical properties of the entrained components. These components include the carrier salt, the actinide fuel, and fission, activation, and corrosion products, the concentrations of which depends on the burnup history of the salt. Radionuclide transport from the salt into the cover gas / off-gas system depends on volatility as predicted by thermochemistry, but data from the Molten Salt Reactor Experiment (MSRE) conducted in the late 1960s suggest that bubble formation and transport are also important. Anomalously high fractions of noble metals were found in the off-gas system and were attributed to transportation with parent salt aerosols and their association with rising noble gas bubbles. The prediction of such phenomena requires coupled neutronic, thermal hydraulic, and chemical equilibrium calculations, the framework of which is being developed within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program supported by the US Department of Energy (DOE) Office of Nuclear Energy (NE). However, separate effects tests and models of experiments using tools such as SAM and Thermochimica can guide model developers through important processes. Conversely, model development guides the choice of experiments and systems to provide data that are relevant for validation. This report describes several experiments that tracked gas transport in molten salts, ranging from small-scale systems to large-scale loops. Gas transportation in a molten salt, LiCl-KCl, has been studied using the shadowgraph technique. Sensors such as residual gas analysis, Raman spectroscopy, and laser-induced breakdown spectroscopy have been tested for off-gas measurements. These data were used to interpret how the gases move through the upstream salt / cover gas and the interface between them. Differential pressure measurements were able to detect individual gas bubbles as they popped at the liquid–gas interface. Salt aerosols were collected on a cascade impactor. Their formation was also observed directly via the shadowgraph method, and most of these aerosols were launched ballistically into the cover gas. Fine mists could also be observed. Convection currents through the salt were visualized and can be used to calculate the thermophysical properties of the salt itself. The apparatuses described in this report and in a previous work (McFarlane et al. 2023) have been commissioned and are available for use in making further measurements of salt/surrogate fission product behavior. Novel approaches using neutron imaging are planned for the study of fluoride salts, which cannot be contained in quartz, so shadowgraph visualization is not available. Bubble transport in convective flow and in a slow-moving salt column are planned. The mobile laser-induced breakdown spectroscopy (LIBS) system is available for several applications, including iodine capture in a molten hydroxide scrubber, H2 transport though molten salts to complement Raman analysis, and online tracking of salt aerosol generation, transport, and deposition. This report summarizes the findings from FY24 and the plans for FY25. The work completes milestone M2AT-24OR0702013 of the DOE-NE Advanced Reactor Technology, Molten Salt Reactor Campaign, DOE-NE-5.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CO{sub 2} laser-induced micro-plume treatment of silicon: technique and application

A method for treating the surface of crystalline silicon (α-Si) covered with a fused silica (SiO{sub 2}) plate by a laser-induced plume arising from the absorption of CO{sub 2} laser radiation in glass is presented. The mechanism of micro-plume formation and the effect of this micro-plume on α-Si sample are considered. The α-Si processing regimes were determined that relate the depth of the formed relief to the radiation power density, the temperature of the micro-plume formed during SiO{sub 2} irradiation was measured and reached 3000 K. The diffraction phase gratings were designed, manufactured on silicon, and tested, they successfully split 10.6 μm laser beam at 0 and ± 1 diffraction orders. The method belongs to the group of direct writing methods and is easily adapted to different types of diffraction elements on the surface of Si and other materials transparent to 10 μm irradiation.

36 MATERIALS SCIENCE↗

Novel Technology of Non-Contact Real-Time Radiation Damage Sensor for High Power Targets

High-power proton beams planned for forthcoming long-baseline neutrino experiments will subject solid targets to unprecedented radiation damage, threatening reliability and increasing costs. To address this challenge, we are building a real-time, non-contact sensor that tracks damage by measuring broadband laser reflectivity changes from the target surface. A low-power super-continuum Class 3B laser illuminates the sample inside a vacuum test chamber while a high-resolution fiber-coupled spectrometer captures S- and P-polarized light; spectral shifts reveal defect-driven variations in optical constants. My internship goal is to design, build, and commission this prototype by implementing a laser-safety interlock and light shield, integrating remote-operation cameras, and fabricating modular 3-D-printed mounts that enable tool-free swaps without disturbing alignment. The laser, spectrometer, and vacuum chamber have been delivered; interlock hardware, cameras, and mounts are in final assembly, and leak testing of the chamber is underway. Upcoming work will focus on initial calibration of the sensor and executing first beam-irradiation studies.

Pumarino, Rafael↗

Breath analysis by ultra-sensitive broadband laser spectroscopy detects SARS-CoV-2 infection

Rapid testing is essential to fighting pandemics such as coronavirus disease 2019 (COVID-19), the disease caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Exhaled human breath contains multiple volatile molecules providing powerful potential for non-invasive diagnosis of diverse medical conditions. We investigated breath detection of SARS-CoV-2 infection using cavity-enhanced direct frequency comb spectroscopy (CE-DFCS), a state-of-the-art laser spectroscopic technique capable of a real-time massive collection of broadband molecular absorption features at ro-vibrational quantum state resolution and at parts-per-trillion volume detection sensitivity. Using a total of 170 individual breath samples (83 positive and 87 negative with SARS-CoV-2 based on reverse transcription polymerase chain reaction tests), we report excellent discrimination capability for SARS-CoV-2 infection with an area under the receiver-operating-characteristics curve of 0.849(4). Our results support the development of CE-DFCS as an alternative, rapid, non-invasive test for COVID-19 and highlight its remarkable potential for optical diagnoses of diverse biological conditions and disease states.

60 APPLIED LIFE SCIENCES↗

Application of tunable diode lasers as local oscillators in an Infrared Heterodyne Radiometer (IHR)

The utility of diode lasers as local oscillators (LOs) in a heterodyne receiver application was investigated. The CW power, spectral tunability, spectral stability, and spatial intensity distribution of the TDL outputs were measured. A tunable diode laser LO was incorporated into a laboratory Dicke-switched infrared heterodyne setup and used to measure radiometer sensitivity as well as spectroscopic characteristics of selected absorption lines of ammonia. The test results on one of the two tunable diode lasers are emphasized in an attempt to provide a comprehensive data package which may be useful for future planning purposes. The second tunable diode laser exhibits characteristics similar to the fully tested TDL with the exception that some changes in its performance characteristics as it was temperature cycled between room temperature and the operating temperature of approximately 50K occurred.

Savage, M. G.↗

Guidance simulation and test support for differential GPS flight experiment

Three separate tasks which supported the test preparation, test operations, and post test analysis of the NASA Ames flight test evaluation of the differential Global Positioning System (GPS) are presented. Task 1 consisted of a navigation filter design, coding, and testing to optimally make use of GPS in a differential mode. The filter can be configured to accept inputs from external censors such as an accelerometer and a barometric or radar altimeter. The filter runs in real time onboard a NASA helicopter. It processes raw pseudo and delta range measurements from a single channel sequential GPS receiver. The Kalman filter software interfaces are described in detail, followed by a description of the filter algorithm, including the basic propagation and measurement update equations. The performance during flight tests is reviewed and discussed. Task 2 describes a refinement performed on the lateral and vertical steering algorithms developed on a previous contract. The refinements include modification of the internal logic to allow more diverse inflight initialization procedures, further data smoothing and compensation for system induced time delays. Task 3 describes the TAU Corp participation in the analysis of the real time Kalman navigation filter. The performance was compared to that of the Z-set filter in flight and to the laser tracker position data during post test analysis. This analysis allowed a more optimum selection of the parameters of the filter.

Geier, G. J.↗

Alpha LAMP Integration Facility

This paper describes the activity recently completed to meet the simulated space environment requirements for the ground-based testing of an integrated Space Based Laser (SBL) system experiment. The need to maintain optical alignment in the challenging dynamic environment of the pressure recovery system required to simulate space dominated the design requirements. A robust system design was established which minimized the total program costs, most notably by reducing the cost of integrating the components of the experiment. The components of the experiment are integrated on an optical bench in a clean area adjacent to the vacuum chamber and moved on air bearings into the chamber for testing.

Oshiro, Richard↗