SEARCH · Engineering Papers
Results for “insertion”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The Arabidopsis T‐DNA mutant SALK_008491 carries a 14‐kb deletion on chromosome 3 that provides rare insights into the plant response to dynamic light stress
Abstract In nature, plants experience rapid changes in light intensity and quality throughout the day. To maximize growth, they have established molecular mechanisms to optimize photosynthetic output while protecting components of the light‐dependent reaction and CO 2 fixation pathways. Plant phenotyping of mutant collections has become a powerful tool to unveil the genetic loci involved in environmental acclimation. Here, we describe the phenotyping of the transfer‐DNA (T‐DNA) insertion mutant line SALK_008491, previously known as nhd1‐1 . Growth in a fluctuating light regime caused a loss in growth rate accompanied by a spike in photosystem (PS) II damage and increased non‐photochemical quenching (NPQ). Interestingly, an independent nhd1 null allele did not recapitulate the NPQ phenotype. Through bulk sequencing of a backcrossed segregating F 2 pool, we identified an ~14‐kb large deletion on chromosome 3 (Chr3) in SALK_008491 affecting five genes upstream of NHD1 . Besides NHD1 , which encodes for a putative plastid Na + /H + antiporter, the stromal NAD‐dependent D‐3‐phosphoglycerate dehydrogenase 3 ( PGDH3 ) locus was eradicated. Although some changes in the SALK_008491 mutant's photosynthesis can be assigned to the loss of PGDH3, our follow‐up studies employing respective single mutants and complementation with overlapping transformation‐competent artificial chromosome (TAC) vectors reveal that the exacerbated fluctuating light sensitivity in SALK_008491 mutants result from the simultaneous loss of PGDH3 and NHD1. Altogether, the data obtained from this large deletion‐carrying mutant provide new and unintuitive insights into the molecular mechanisms that function to protect the photosynthetic machinery. Moreover, our study renews calls for caution when setting up reverse genetic studies using T‐DNA lines. Although second‐site insertions, indels, and SNPs have been reported before, large deletion surrounding the insertion site causes yet another problem. Nevertheless, as shown through this research, such unpredictable genetic events following T‐DNA mutagenesis can provide unintuitive insights that allow for understanding complex phenomena such as the plant acclimation to dynamic high light stress.
Color-kinematics dual representations of one-loop matrix elements in the open-superstring effective action
Abstract Theα ′ -expansion of string theory provides a rich set of higher-dimension operators, indexed byζvalues, which can be used to study color-kinematics duality and the double copy. These two powerful properties, actually first noticed in tree-level string amplitudes, simplify the construction of both gauge and gravity amplitudes. However, their applicability and limitations are not fully understood. We attempt to construct a set of color-kinematics dual numerators at one loop and four points for insertions of operator combinations corresponding to the lowest fourζ 2 -free operator insertions from the open superstring:ζ 3 ,ζ 5 ,$$ {\zeta}_3^2 $$ ζ 3 2 , andζ 7 . We succeed in finding a representation for the first three in terms of box, triangle, and bubble numerators. In the case ofζ 7 we find an obstruction to a fully color-dual representation related to the bubble-on-external-leg type diagrams. We discuss two paths around this obstruction, both of which signal an incompatability between color-kinematics duality and manifesting certain desired properties. Using the constructed color-dual numerators, we find two different Bern-Carrasco-Johansson double copies that produce candidate closed-string-insertion numerators. Both approaches to the double copy match the kinematics of the cuts, with relative normalization set by either summing over both double copies including degeneracy or by including an explicit prefactor on the double-copy numerator definitions.
Giant Wilson loops and AdS 2 /dCFT 1
The 1/2-BPS Wilson loop in N = 4 supersymmetric Yang-Mills theory is an important and well-studied example of conformal defect. In particular, much work has been done for the correlation functions of operator insertions on the Wilson loop in the fundamental representation. In this paper, we extend such analyses to Wilson loops in the large-rank symmetric and antisymmetric representations, which correspond to probe D3 and D5 branes with AdS 2 × S 2 and AdS 2 × S 4 worldvolume geometries, ending at the AdS 5 boundary along a one-dimensional contour. We first compute the correlation functions of protected scalar insertions from supersymmetric localization, and obtain a representation in terms of multiple integrals that are similar to the eigenvalue integrals of the random matrix, but with important differences. Using ideas from the Fermi Gas formalism and the Clustering method, we evaluate their large N limit exactly as a function of the ’t Hooft coupling. The results are given by simple integrals of polynomials that resemble the Q-functions of the Quantum Spectral Curve, with integration measures depending on the number of insertions. Next, we study the correlation functions of fluctuations on the probe D3 and D5 branes in AdS. We compute a selection of three- and four-point functions from perturbation theory on the D-branes, and show that they agree with the results of localization when restricted to supersymmetric kinematics. We also explain how the difference of the internal geometries of the D3 and D5 branes manifests itself in the localization computation.
Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction
Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival time between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4.38 to 1.48 (p < 0.01). There were no short-term complications. Late complications including hematemesis (n = 3), migration (n = 12), and stent occlusion due to tumor overgrowth (n = 5) were evenly distributed between the groups. In the DIT group chemotherapy-induced neutropenia and transient renal dysfunction were detected in six patients, which improved after symptomatic management. Mean survival time after the procedure was 5.9 and 11.1 months for MSI and DIT, respectively (P < 0.001). In conclusion, both MSI and DIT offer effective palliation for malignant gastroduodenal obstruction, but DIT appears to offer superior survival over MSI alone. Ideally, a prospective randomized trial comparing these two techniques should be carried out to validate this result.
Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture
Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.
Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure
Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.
British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry
Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.
Stenting of the Cystic Duct in Benign Disease: A Definitive Treatment for the Elderly and Unwell
PurposeThere have been few case reports describing cystic duct stent insertion in the management of acute cholecystitis secondary to benign disease with no case series published to date. We present our series demonstrating the role of cystic duct stents in managing benign gallbladder disease in those patients unfit for surgery.Materials and MethodsThirty three patients unfit for surgery in our institution underwent cystic duct stent insertion for the management of acute cholecystitis in the period June 2008 to June 2013. Patients underwent a mixture of transperitoneal and transhepatic gallbladder puncture. The cystic duct was cannulated with a hydrophilic guidewire which was subsequently passed through the common bile duct and into the duodenum. An 8Fr 12-cm double-pigtail stent was placed with the distal end lying within the duodenum and the proximal end within the gallbladder.ResultsTen patients presented with gallbladder perforation, 21 patients with acute cholecystitis, 1 with acute cholangitis and 1 with necrotising pancreatitis. The technical success rate was 91 %. We experienced a 13 % complication rate with 3 % mortality rate at 30 days.ConclusionCystic duct stent insertion can be successfully used to manage acute cholecystitis, gallbladder empyema or gallbladder perforations in those unfit for surgery and should be considered alongside external gallbladder drainage as a definitive mid-term treatment option.
CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques
PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.
CT Fluoroscopy-Guided Transsacral Intervertebral Drainage for Pyogenic Spondylodiscitis at the Lumbosacral Junction
PurposeTo retrospectively describe the feasibility and efficacy of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction with a combination of two interventional radiological techniques—CT-guided bone biopsy and abscess drainage.Materials and methodsThree patients with pyogenic spondylodiscitis at the lumbosacral junction were enrolled in this study between July 2013 and December 2015. The procedure of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction was as follows: the sacrum at S1 pedicle was penetrated with an 11-gauge (G) bone biopsy needle to create a path for an 8-French (F) pigtail drainage catheter. The bone biopsy needle was withdrawn, and an 18-G needle was inserted into the intervertebral space of the lumbosacral junction. Then, a 0.038-inch guidewire was inserted into the intervertebral space. Finally, the 8-F pigtail drainage catheter was inserted over the guidewire until its tip reached the intervertebral space. All patients received six-week antibiotics treatment.ResultsSuccessful placement of the drainage catheter was achieved for each patient without procedural complications. The duration of drainage was 17–33 days. For two patients, specific organisms were isolated; thus, definitive medical therapy was possible. All patients responded well to the treatment.ConclusionsCT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction is feasible and can be effective with a combination of two interventional techniques—CT fluoroscopy-guided bone biopsy and abscess drainage.
The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein
PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.
Post-Biopsy Manoeuvres to Reduce Pneumothorax Incidence in CT-Guided Transthoracic Lung Biopsies: A Systematic Review and Meta-analysis
This systematic review and meta-analysis investigated post-biopsy manoeuvres to reduce pneumothorax following computed tomography-guided percutaneous transthoracic lung biopsy. Twenty-one articles were included with 7080 patients. Chest drain insertion rates were significantly reduced by ninefold with the normal saline tract sealant compared to controls (OR 0.11, 95% CI 0.02–0.48), threefold with the rapid rollover manoeuvre to puncture site down (OR 0.34, 95% CI 0.18–0.63), threefold with the tract plug (OR 0.33, 95% CI 0.22–0.48) and threefold with the blood patch (OR 0.39, 95% CI 0.26–0.58). The absolute chest drain insertion rates were the lowest in the normal saline tract sealant (0.8% vs 7.3% for controls), rapid rollover (1.9% vs 5.2%), deep expiration and breath-hold on needle extraction (0.9% vs 1.8%) and standard rollover versus no rollover (2.6% vs 5.2%). These findings highlight post-biopsy manoeuvres which could help reduce pneumothorax and chest drain insertions following lung biopsies. Level of Evidence: Level 1/no level of evidence, systematic review.
Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow
Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.
Enhanced Pinning Properties of the Bilayers of YDy{sub 0.5}Ba{sub 2}Cu{sub 3}O{sub 7−δ} by SrZrO{sub 3} Nanoparticles through Low Fluorine Metallorganic Solution Deposition
Bilayered YDy{sub 0.5}Ba{sub 2}Cu{sub 3.6}O{sub 7−δ} superconducting films with a thickness of about 1 μ were deposited by metallorganic deposition method, an interlayer of secondary phase of SrZrO{sub 3} (SZO) and BaZrO{sub 3} (BZO) were inserted. Detailed growth mechanism studies of these structures as well as superconducting properties in different temperatures and magnetic field range (0–5 T) were investigated. Structural analysis showed that bilayer structure changed clearly the growth mechanism of YBCO. The SZO interlayer smoothens the film surface. Magnetic measurements of superconducting properties demonstrated that the critical temperature decreases slightly when both of SZO and BZO interlayer were inserted. This indicates a growing strain effect at the layer interfaces. The critical current densities as well as pining forces of bilayered YDy{sub 0.5}Ba{sub 2}Cu{sub 3.6}O{sub 7−δ} in the entire applied temperature and magnetic field range were enhanced by the insertion of SZO layer and decreased when BZO layer is introduced. The enhancement of the pinning properties is explained by the dense flux pinning in layered YDyBCO superconductors; this result may give further improvements in the current-carrying capability.
Synthesis of cobalt and nickel 6,6′-diphenylbis(dicarbollides)
6,6′-Diphenyl derivatives of cobalt and nickel bis(dicarbollide) were synthesized starting from nido-carborane by the insertion—deboronation—insertion sequence of reactions. The by-products of the insertion of PhBCl{sub 2} into the nido-carborane cage, diethyloxonium derivatives of nido-carborane [9-Et{sub 2}O-7,8-C{sub 2}B{sub 9}H{sub 11}] and [10-Et{sub 2}O-7,8-C{sub 2}B{sub 9}H{sub 11}], were isolated and characterized. Treatment of the latter with pyridine resulted in the elimination of one ethyl group to give the corresponding ethoxy derivatives. The structures of nido-carborane 10-diethyloxonium derivative and cobalt bis(dicarbollide) 6,6′-diphenyl derivative were established by X-ray diffraction analysis.
Chemo-Mechanics of α-V 2 O 5 During Lithiation and Implications for Rechargeable Battery Cathodes
Chemo-mechanical degradation of layered oxide electrodes is strongly influenced by crystallographic anisotropy, local stress evolution, and ion insertion, yet the intrinsic mechanical response of layered materials remains incompletely understood. Indeed, most prior studies have focused on polycrystalline materials but single crystals enable direct observation of coupling between anisotropic ion diffusion and mechanical response. This study aims to determine how crystallographic anisotropy and lithiation affect deformation, fracture, and mechanical properties in single-crystal V 2 O 5 , and compares this behavior with polycrystalline counterparts. Polycrystalline V 2 O 5 thin films and single-crystal α-V 2 O 5 were studied using nanoindentation, scanning electron microscopy, focused ion beam cross-sectioning, and Raman spectroscopy. Single crystals were tested in pristine and chemically lithiated states, including experiments in which crystals were first plastically deformed via nanoindentation and subsequently lithiated. Polycrystalline films exhibited significantly higher hardness and elastic modulus than single crystals. Single crystals indented normal to the exposed (001) basal plane exhibited pronounced anisotropic deformation, including directional slip, crystallographically-guided cracking, anisotropic crack propagation, interlayer separation, and shear localization. Lithiation caused substantial softening, reduced hardness and modulus, and suppressed displacement bursts during nanoindentation, while previously indented regions showed crack formation and growth upon lithiation. Mechanical behavior of α-V 2 O 5 is strongly governed by crystallographic anisotropy and further altered by lithiation, with pre-existing deformation serving as a strong driver of fracture during ion insertion. These findings illuminate the coupling among ion insertion, deformation, and fracture in layered oxides and provide a basis for understanding and mitigating mechanical failure in electrochemical energy-storage materials.
Improvement of Tribological Performance of AISI H13 Steel by Means of a Self-Lubricated Oxide-Containing Tribo-layer
A self-lubricated oxide-containing tribo-layer was induced to form by continuously adding particles of MoS{sub 2}, Fe{sub 2}O{sub 3} or their mixtures onto sliding interfaces of AISI H13 and 52100 steels. The artificial tribo-layer was always noticed to form continuously and cover the worn surface (termed as cover-type), whereas the original tribo-layer spontaneously formed with no additive was usually discontinuous and inserted into the substrate (termed as insert-type). Clearly, the cover-type and insert-type tribo-layers exactly corresponded to low and high wear rates, respectively. For the mixed additives of Fe{sub 2}O{sub 3} + MoS{sub 2}, the protective tribo-layers presented a load-carrying capability and lubricative function, which are attributed to the existence of Fe{sub 2}O{sub 3} and MoS{sub 2}. Hence, the wear rates and friction coefficients of H13 steel were markedly reduced.